HoMedics ME User manual

user guide
Validate your warranty for me at www.memyelos.com
and also receive product updates and special offers
English, Italiano, Deutsch
the fastest way to permanent hair reduction

NB: If you feel discomfort, treat at a lower
level. If tolerable, increase the elo
- s setting
for higher efficacy.
NB: Do not use on sun burned or tanned
skin, as tanning may influence the safety of
the treatment. Wait until the sunburn or tan
fades prior to performing a test patch on an
inconspicuous area. Reexamine the area
after 3 days to ensure no side effects have
occurred.
NB: Do not tan 24 hours after me
-
treatment.
NB: During treatment, DO NOT hold
the applicator tip still in one spot!
Important safety information
Please read all warnings and safety information
in user manual before using me
-
.
Note: If you have an active tan do not use me
-
.
Preparation
1. Clean your skin and wipe the area with a
non-alcoholic wipe.
2. Shave hair in treated area or, if you use the
shaver or epilator - trim hair that is longer than
10 mm (you may use the shaver cartridge).
Treatment
1. Press the power button to
turn the system on.
2. Select the elo
- s level by pressing the button
near the appropriate level based on the
attached table.
3. Press the elo
- s activation button.
4. Press the epilator/shaver activation button to
select desired speed (epilator and shaver are
sold separately). Visit www.memyelos.com.
5. Ensure you are touching the two grip sensors.
6. Hold the applicator in a position ensuring full
contact of the RF delivery bars with the skin.
Do not press, just gently touch the skin.
System will start emitting elo
- s pulses.
7. Use the system slowly and continuously
gliding on the treatment area without
stopping in one place. Try not to repeat
treatment on the same spot for at
least 10 seconds.
Treatable Skin Types
Skin Type 1 – Pale white skin
(always burns, does not tan)
elo
- s
Level: High
Skin Type 2 – Fair skin
(burns easily, rarely tans)
elo
- s
Level: High
Skin Type 3 – Darker white skin
(tans after initial sunburn)
elo
- s
Level: High
Skin Type 4 – Light brown skin (burns minimally,
tans easily)
elo
- s
Level: Medium-to-High
Skin Type 5 – Brown skin (rarely burns,
tans dark & easily)
elo
- s
Level: Low-to-Medium
Skin Type 6 – Dark brown or black skin
(never burns, dark tan):
Do not use the
me
-
system!
Quick Reference Guide

epilator
and shaver
cartridge
activation
When to use me
-
1. perform first 4 treatments every 2 weeks
2. after first 6 weeks, use me
-
as hair appears (up to 3 months between treatments)
When you have finished
the treatment
1. Place the applicator in its cradle in the
base unit.
2. Turn off the me
-
device by pressing the
power button on the base unit. The
cooling vents will continue to work for 4
additional seconds after the elo
- s is
turned off.
3. Gently rinse your skin with lukewarm
water and pat dry.
4. Gently apply moisturizing cream or gel aloe
vera to your skin (if epilator was used, it is
recommended to apply just aloe vera).
1minute per
underarm 3 minutes
per arm 10 minutes
per full leg
2 minutes
bikini area
Treatment durations:
For effective results, me
-
should be used
according to the following timings.
elo
-s
activation
button
grip sensorsRF delivery bars

Table of contents
Detachable Quick Reference Guide
About the me
-
hair removal system ________________________________ 6
Box contents _________________________________________________ 6
Important safety information _____________________________________ 7
System description ____________________________________________ 10
How to prepare the me
-
system for operation _______________________ 12
System preparation____________________________________________ 14
Recommended elo
- s levels ______________________________________ 16
How to operate the me
-
system___________________________________ 17
me
-
treatment procedure ________________________________________ 21
When to use me
-
_____________________________________________ 22
How to replace your elo
- s cartridge_______________________________ 24
Troubleshooting_______________________________________________ 25
Specifications ________________________________________________ 26
Labels and symbols____________________________________________ 27
EN

6
About the me
-hair removal system
Your new me
-
system is intended for
long-term hair removal. The me
- system
is easy to use without assistance, and
in the convenience of your own home.
The system is intended for both women
and men with Fitzpatrick skin tones I-V
(see page 16 to evaluate whether your
skin type can be treated). The system is
designed for the removal of hair from all
body parts below the neck.
The me
-system is powered by elo
- s™
(Electro-Optical Synergy), clinically proven,
gold standard technology that uses low-
energy pulsed light together with gentle
radio frequency (RF).
NB: Hair reduction results may be subject
to variation.
Please read this entire user guide and
watch the instructional DVD (included)
before using the system for the first time.
It is recommended to keep the guide in
a safe place for future referrals and to
re-familiarise yourself with this user guide
prior to each use of me
-
.
Box contents
Upon opening the me
-package you will
find the following components:
Base unit and applicator, including:
elo
- s cartridge and epilator/shaver
protective cap (already attached)
Accessories kit, including:
elo
- s protective cap
Electrical power cord
Cleaning brush
User guide (including a quick
reference guide)
Instructional DVD
Warranty card
Additional accessories (sold separately):
Epilator with cleaning brush
Shaver with cleaning brush
elo
- s replacement cartridge
Facial kit (includes sperate instructions
for use and user’s eye protection).
Visit www.memyelos.com
EN

7
Important safety information
Please read all warnings and safety
information before using the me
-system.
Always follow basic safety precautions
when using any electrical product.
The system is designed for domestic use only.
Warnings
The system is designed for the removal
of human body hair. Any other use is
expressly prohibited; DO NOT use the
system for removal of hair on your face
or head. Facial hair should only be
removed using the facial kit that includes
sperate instructions for use and user’s eye
protection. Visit www.memyelos.com.
DO NOT use the me
-
system
over tattoos or permanent makeup.
During treatment, DO NOT hold the
applicator tip still in one spot! This
might cause extensive heat build-up and
possible skin damage.
NEVER immerse the system or the
applicator tip in water or any other
liquid. DO NOT rinse any components of
the system with any kind of liquid.
DO NOT use the system where it can
fall or be pulled into water. If device is
dropped in water, unplug it immediately.
DO NOT remove the device from water
until unplugged. DO NOT use the device
again. Contact customer service centre.
If dropped or damaged, DO NOT
use the system.
Always disconnect the power cord from
the wall electrical outlet after use.
DO NOT use the system if any of its
components show signs of damage.
DO NOT open the system’s enclosure
under any circumstances.
DO NOT operate the device with a
cracked or broken glass window on the
elo
-s cartridge.
To avoid accidents, keep the system
away from the hair on your head, face,
and also from clothes, brushes, wires,
cords, laces, etc.
DO NOT use the system on children or
allow children to use this device. Keep
the system out of the reach of children.
Adult supervision is recommended for
teenagers under the age of 18.
DO NOT use the system if you have
limited physical, sensory or mental
capabilities. This does not apply to the
latter if they were instructed in the use
of the system or if they use it under the
supervision of a person responsible for
safety.
Complete power shutdown will be achieved
only when the power cord is unplugged.
EN

8
When NOT to use the me
-system
You should NOT use the me
-
system if any of
the following items apply to you:
If your skin type is darker than skin type
5 (see page 16).
If within the last three days you have
had a long skin exposure to the sun,or
if you have excessively tanned skin from
sun, tanning beds or tanning creams
within the last two weeks, as tanning may
influence the safety of the treatment.
If you have a pacemaker or internal
defibrillator.
If you have superficial metal or other
implants in the desired treatment area.
If you have a history of any type of
cancer, or pre-malignant moles.
If you suffer from severe conditions,
such as cardiac disorders.
If you have varicose veins in the
treatment area.
If you have moles, large freckles, darker
pigmented areas, scars or birthmarks
do not treat over them.
If you are pregnant or nursing.
If you have an impaired immune
system due to immunosuppressive
diseases such as AIDS and HIV, or use of
immunosuppressive medications.
If you have endocrine disorders, such as
Diabetes or Polycystic Ovary Syndrome.
If you have any active condition in the
treatment
area, such as sores, psoriasis,
eczema, burns, herpes simplex, wounds
or a rash.
If you have a history of skin disorders,
abnormal wound healing, as well as very
dry and fragile skin.
If you have a history of bleeding
coagulopathies, or use of anticoagulants.
If you are using medications, herbs,
food supplements, and vitamins known to
induce photosensitivity to light exposure at
the wavelength used, such as Isotretinoin
(Accutane) and/or topical retinoids within
the last six months, Tetracyclines, or St.
John's Wort within the last two weeks.
If you are using medications that may
stimulate hair growth, such as Minoxidil.
If you have had any surgical procedure
in the treatment area within the last three
months or before complete healing.
If you have Epilepsy.
If you have applied any type of anesthetics.
If you are on gold therapy
NB: If you are taking any medication,
please consult with your doctor before
using me
-
.
EN

9
Possible side effects
Removing hair can cause redness or
irritation of the skin. This is a normal
reaction and only lasts a short time.
NB: If sensitivity of area persists longer
than 24 hours, consult your doctor.
Improper use of the me
-
system could
result in possible side effects. Although
these effects are rare and expected to
clear within a short time, it is important to
understand that every cosmetic treatment
may involve some degree of risk, and that
you understand and accept the risks and
possible complications that can occur with
pulsed light combined with RF hair removal
systems. Side effects may include redness
or swelling and colour changes to your
skin. This may appear either at the time of
treatment or shortly after.
NB: If unusual pain occurs, you should
stop treatment. If you encounter any severe
side effects, consult your doctor.
1. This device is not intended for use by
individuals (including children) whose physical,
sensory or mental capacities are reduced or
who have no experience with the device or
do not know how to use it, unless they are
supervised or have received prior instructions
from a person in charge of their safety.
2. Children should be supervised to ensure they
do not play with the device.
3. The devices should not be turned on via
an outside timer or a separate remote control
system.
4. WARNING: Keep appliance away from
water.
EN

10
1
2
3
4
5,6
System description
Your me
-
system is designed to be easy to
use and is easy to maintain. The system is
comprised of the following components:
1. Base unit
2. Control panel
3. Applicator
4. elo
-s cartridge
5. Epilator cartridge or
6. Shaver cartridge
NB: Epilator and Shaver are sold separetly.
Visit www.memyelos.com
EN

11
The treatment is done using the elo
-s
cartridge and if you like,
you simultaneously use the epilator
or shaver cartridges (Sold separately):
1. elo
-
s cartridge
Intense pulsed light (IPL) output window.
Radiofrequency (RF) delivery bars.
2. Epilator cartridge
Rotating epilating mechanism.
3. Shaver cartridge
Foil covered shaver combined with a trimmer.
1
2 3
EN

12
bottom side
epilator
or shaver
cartridge
top side
elo
-s cartridge
How to prepare the me
-system for
operation
The me
-
system is easy to use and easy to
care for.
Your new me
-
system has the elo
-s cartridge
and epilator protective cap already
connected to the applicator.
1. If you want to use the epilator or
shaver - you should remove the protective
cap, press the two blue buttons to slide
one cartridge out and insert the other one
in its place. Slide the new cartridge into the
applicator until you feel it "click" into place.
NB The elo
-s cartridge is not
interchangeable with the epilator or
shaver cartridges.
Before use, make sure that the RF delivery
bars and the light output window on
the elo
-s cartridge are clean (these may
be cleaned using a soft tissue or non-
alcoholic wet wipes).
NB: Epilator and Shaver are sold separately.
Visit www.memyelos.com
EN

13
Cap
NB: The system can be operated just
with the elo
-s cartridge (shaver/epilator
protective cap must be attached to
applicator’s opposite side).
NB: The system can be operated just with
the shaver or epilator cartridge
(protective cap must be attached to
applicator’s opposite side).
EN

14
System preparation
The following illustrations display the base unit’s control panel and the applicator, and the
following pages will explain how to prepare the system for use.
Getting familiar with me
-’s control panel
Getting familiar with me
-’s applicator
shaver / epilator
activation
indicators
epilator
or shaver
activation
button
cooling inlet
epilator or shaver
cartridge
grip sensors
cartridge
release
buttons
elo
-s cartridge
elo
-s cartridge
release buttons
epilator or shaver
cartridge release
button
elo
-s
activation
button
elo
-s
activation
indicator
EN

15
2. Before turning on the system, the applicator must be
placed in the cradle. Press the power button to turn
the system on; the elo
- s system indicators will flash for
several seconds, then the indicator next to the power
button will turn green.
Now the system is ready for use.
3. Select the elo
- s level you want to use by pressing
the appropriate elo
- s Level button: High, Medium or
Low; the active level will illuminate a white indicator
light. (Refer to the chart on page 16 of the user
guide to set the right level for your skin type).
4. The elo
- s cartridge is pre-loaded with a set number of pulses for
your use; the counter starts at 100% and decreases as you use it.
The amount of pulses remaining in the cartridge is indicated
by the lights on the panel, as shown. Once the elo
- s cartridge
reaches 5% of its capacity, a red light will start blinking, and at
0%, the red light will remain constant, indicating that the
cartridge must be replaced and responsibly disposed of. (Please
refer to the WEEE explanation on page 27).
1. Connect the power cable into the system and then
into the wall electrical outlet. An orange indicator
will appear next to the power button.
EN

16
NB: If you have an excessive tan DO NOT use me
-
.
Treatable Skin Tones*
Skin Type 1 – Pale white skin (always burns, does not tan)
elo
- s
Level: High
Skin Type 2 – Fair skin (burns easily, rarely tans)
elo
- s
Level: High
Skin Type 3 – Darker white skin (tans after initial sunburn)
elo
- s
Level: High
Skin Type 4 – Light brown skin (burns minimally, tans easily)
elo
- s
Level: Medium-to-High
Skin Type 5 – Brown skin (rarely burns, tans dark & easily)
elo
- s
Level: Low-to-Medium
Skin Type 6 – Dark brown or black skin (never burns, dark tan):
Do not use the
me
-
system!
Recommended levels
Determine your skin type based on the
descriptions below and set your me
-
system's elo
- s level accordingly.
If using the recommended elo
- s level
causes discomfort, treat at a lower level.
If comfortable, increase the elo
-s level for
higher efficacy.
*For facial hair removal be sure to refer to the Treatable Facial Skin Tones Table attached to
the kit. Visit www.memyelos.com
EN

17
grip sensors
RF delivery bars
elo
-s activation
button
How to operate the me
-system
Preparation
Your skin should be clean before starting
the treatment. There should be no lotion,
make-up, perfume, powder or bath/shower
oil present on the skin in the area to be
treated. Before treatment, wipe the area
with a non-alcoholic wipe.
You can choose one of two options:
1. Use with either the epilator or shaver
accessory (sold separately)
simultaneously during treatment with
elo
- s. In this case, there is no need for
shaving prior to treatment.
NB: You can use the epilator or shaver
if you have hair up to 10mm.
2. If you do not use the shaver or epilator
accessories, you should shave the
required area prior to the elo
- s treatment.
NB: to ensure best results, you should not
remove hair by waxing or epilator more
than 5 minutes prior to elo
- s treatment.
Best results are achieved when the
epilator or shaver accessories are used
simultaneously with elo
- s.
EN

18
epilator
and shaver
cartridge
activation
Treating with epilator or shaver cartridge
(optional)
if you choose not to use the epilator/shaver - you
must insert the epilator protective cap (provided) to
allow system operation.
1. After you have chosen your desired elos level
and activated the elo
- s cartridge:
Press the epilator/shaver cartridge activation
button once to run the epilator mechanism
at low speed; the number 1 indicator will light
up. If desired, press it again to run the epilator
mechanism at high speed; the number 2
indicator will light up.
NB:
The shaver cartridge (under foil cover) operates only at speed1.
In case you prefer not to use the epilator or shaver, make sure their protective cap is
attached to the applicator to allow elos cartridge operation
EN

19
NB: It is essential to watch the
instructional DVD before using the system
for the first time.
NB: It is recommeded to use the system
in an area with good natural light or in a
well lit environment.
NB: When using the device on difficult to
treat areas (eg. underarm) work the area
in 2 directions at a 90 degree angle,
for full coverage. Hard-to-reach areas can
also be treated by first using either the
shaver or epilator, using the protective cap
in place of the elo
- s cartridge, followed
by the application of elo
- s (while placing
the protective cap on the shaver/epilator
side). Shaver and epilator attachments sold
separately.
NB: The first time you use the system with
the epilator cartridge, it may feel slightly
uncomfortable, as you are removing hairs
from the follicles. This feeling subsides
after a few treatments, even if you have
sensitive skin.
NB: It is not recommended and there
is no need, to look directly at the light
flashes.
2. With the thumb and forefinger of your
hand, lightly touch the two metal
grip sensors, one on each side of
the applicator.
3. Apply the tip of the applicator on
your skin so that the two RF delivery
bars are in complete contact with
the skin.
4. Once full contact is achieved, you will
notice light flashes, indicating that the
system is operating. The elo
- s activation
button will automatically turn itself off
if no pulses have been emitted for one
continuous minute.
5. Use the system as you would use an
epilator/shaver by continuously gliding
on the treated area.
6. Move the applicator slowly and
continuously without stopping in one
place so that the light flashes will
follow each other and cover the entire
area. Try not to repetitively go over the
same spot for at least 10 seconds.
DO NOT hold the device in one spot.
DO NOT treat the face. Facial hair
should only be removed using the facial
kit that includes dedicated instructions for
use and user’s eye protection.
Visit www.memyelos.com
EN

20
Important Note! Do not block or cover the
applicator's cooling inlet during operation
to avoid overheating of the applicator.
cooling inlet
hot air
outlet
Please be warned hot air will come out of the
hot air outlet once the system is in use.
correct incorrect
Important Note! The elo
- s cartridge
will not operate unless both RF delivery
bars are in contact with the skin, and
you are touching both grip sensors on
the applicator.
skin surfaceskin surface
both RF
delivery bars
are in contact
with the skin
EN

21
me
-treatment procedure
choosing your configuration:
HoMedics recommends that you integrate
your tried-and-tested hair removing habits
with your new me
-
system:
If you are used to using a razor -
you can shave the treated area before
using the elo
- s cartridge only. Maintain
the time of treatment and protocol as
illustrated.
If you are used to using an electric
shaver, you can now use the me
-
system
with the and shaver cartridges.
If you are used to using an epilator,
you can now use the system with the
elo
- s and epilator cartridges.
If you are used to any combination
of shaving or epilating in different
areas of your body, use the me
-
system
in the same method. When treating
light hair, it is recommended to use the
elo
- s+epilator combination for higher
efficacy.
Treatment durations:
For effective results, me
-
should be used for
approximately the amount of time indicated
for each body area.
1minute per
underarm 2 minutes
bikini area
3 minutes
per arm 10 minutes
per full leg
Treatable skin types DO NOT USE
EN
Other manuals for ME
2
Table of contents
Languages:
Other HoMedics Epilator manuals