HSC ELITE BCE45LV2 User manual

ELITE
BCE45LV2 & BCE60LV2 –
OPERATION AND SAFETY USER
MANUAL
IMPORTANT SAFETY INSTRUCTIONS
Before using this product, please read this user manual, if you do not understand any of the
instructions within, please do not use the product and consult your retailers or the manufacturer.
Failure to follow these instructions may result in damage to the product, property and/or cause
personal injury to the user or bystanders.
SAFETY, OPERATION & MAINTENANCE INSTRUCTIONS FOR: BCE45LV2 & BCE60LV2
KEEP THIS BOOKLET FOR FUTURE REFERENCE
USER MANUAL
CONTROLLED DOCUMENT No.: 00234UIRS0123V1

Page 2of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
Table of Contents
Inspect your new product
Page 3
Product Key Component Identification
Page 3
General Safety Information
Page 4
Caution
Page 4
Installation and Set-up
Page 5
Control Panel & Wiring Diagram
Page 5
Maintenance, testing and troubleshooting
Page 6
Storage & Transport
Page 6
Specification Data Table
Page 7
Recycling
Page 8

Page 3of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
Product Key Component Identification –
Inspect your new product
Thank you for purchasing the Elite BCE45LV2 & BCE60LV2 manufactured to the highest standards drawing upon over
20 years’ experience supplying the UK hire and construction industry, this product will, if used in accordance with
these operating instructions, labels affixed to the product and properly maintained, provide you with many years of
reliable service.
The Elite evaporative air coolers use the “evaporation reduces air temperature “, principle. It uses the water saturated
cooling pad located on the sides and back of the unit to add moisture to the air therefore reducing the air
temperature and increasing the humidity to provide the user with a more comfortable environment and cooling
effect.
Water is sprayed onto the filtered cooling pads by continuously pumping and recycling the system water, this water
then evaporates as the hot air is passed through these saturated filtered cooling pads. This filtered, oxygen enriched
water-cooled air is blown out into the area creating a cooler workplace.
Evaporative air coolers are energy efficient saving both running costs and the planet compared to other air-cooling
products.

Page 4of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
General Safety Information
Do not position the cooler up against the wall and position near any other structure that may restrict the air flow around the
unit. Ensure a 1-meter gap is observed around the unit when in use.
Always ensure there is sufficient air flow around all sides of the unit.
When not in use always remove the unit from the power supply.
When removing the plug from the socket always do so by holding and pulling the main body of the plug and NOT the cable.
DO NOT modify this equipment to do tasks other than those intended, this will invalidate your warranty, product approvals
and pose a risk to the user, bystanders, and property.
DO NOT use in in an enclosed environment. There must be sufficient air flow for the unit to function correctly and perform
to its full capabilities.
Never leave the unit running unattended.
DO NOT use the equipment if there is any damage noted on the mains inlet cable.
Ensure the mains cable does not present a trip hazard.
DO NOT run the main cable across walkways, paths or in front of doors / doorways. Once the cable has been routed into the
desire position please secure. Also consider and avoid sharp edges, water and chemicals when positioning the cable.
Ensure the cable is fully unwound before use.
If the external mains cable is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar
qualified person in order to avoid hazard.
In some applications it may be necessary to complete a risk assessment and method statement on the use of this product.
Please note this is the responsibility of the user to consider all foreseen and unforeseen risks and mitigate where possible.
Reading, understanding and adhering to these user instructions is essential for safe use and sufficient product training.
Ensure the equipment is connected to the correct voltage, refer the equipment’s rating plate before connection and
switching on.
Caution
DO NOT use the equipment if there are any signs of damage that may present a hazard in use. If you are unsure seek advice
from a qualified person, retailer, or the manufacturer.
It is recommended this unit is used with an RCD device.
Ensure your hands are dry when connecting, using, and disconnecting and electrical appliance.
Always make sure the plug fuse and any other circuit protection is of the correct rating, refer to the products rating label. If
you are unsure, please contact either the reseller or manufacturer for assistance.
DO NOT leave the unit plugged in and/or running unattended where young children or infirm people may be able to touch the
unit.
Always ensure children and people with reduced mental capabilities are supervised at all times where the unit is used and in
operation.
DO NOT USE IN COMPUTER SERVER ROOMS OR ANY AREAS CONTAINING MOISTURE SENSITIVE ELECTRONIC EQUIPMENT
WHERE INCREASED AIR HUMIDITY CAN DAMAGE THIS EQUIPMENT. If in doubt consult your supplier for advice and

Page 5of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
Installation and Set-up
Assembly instruction and any other consideration for the safe set-up of the product.
Remove packaging used to secure product in transit including any materials to protect the cooling pads
Attach castors to the bottom of the unit. For the BCE45LV2 the castors attach directly onto the base
moulding. For the BCE60LV2 the castors are affixed to a moulded castor bracket, connect these brackets
directly onto the base.
The following tools will be required to complete the assembly requirements - PZ2 – pozi-drive screwdriver
Choose either of the following two methods to fill the unit with water:
A. Automatic - Attach a ½” hose connector to the fill inlet on the equipment.
B. Manual – Open the water inlet door and fill.
ALWAYS ENSURE THE EVAPORATIVE AIR COOLER IS UNPLUGGED WHILST FILLING WITH WATER.
DO NOT EXCEED THE MAXIMUM WATER LEVEL SHOWN ON THE WATER LEVEL DISPLAY
•Turn the equipment on by turning the “FAN” switch dial to either LOW or HIGH
Control Panel
1. SWING: Controls the swing function to direct the air over a greater area.
2. FAN: Turn clockwise to control the speed of the fan. There are 3 speed setting, LOW, MEDIUM, and HIGH
NOTE: The Elite Evaporative Air Cooler can be used in fan only mode without water
3. PUMP: Once in the on position the water will start to recirculate and give the unit the cooling function
NOTE: There is a dedicated earth point clearly identified on the control panel for Class I earth continuity
testing.
Wiring Diagram

Page 6of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
Maintenance, testing and troubleshooting
•To maximise the performance of the Elite Evaporative cooler it is suggested to drain the water completely at
the end of each day. This will ensure the prolonged life of the cooling pads and help prevention of mineral
deposits inside the unit.
•Only use clean cold water inside the unit.
•Once a month ensure the unit is emptied and cleaned thoroughly using a sterilising, non-toxic cleaning
fluid/tablet.
•Visually check the outside of the unit and the power cable, including the plug, before every use for any
damage.
•The Evaporative Cooler is a Class 1 appliance and therefore must be earth. The earth test point can be
located on the front control panel where the earth symbol can be found.
Fault
Possible Cause
Possible Solution
No air flow
1. Unit is not plug in.
2. No power to equipment.
3. Air inlets blocked
4. Faulty fan motor
1. Make sure the unit is plugged in
and switched on.
2. Check the mains power supply
3. Check for obstructions.
4. Replace fan motor
Not cooling / unit is
making a noise
1. Pump has not been turned on.
2. Low or no water in the tank.
3. Blocked water inlets to cooling pads
4. Damaged pump
1. Turn on pump / cold air function
on the control panel.
2. Refill the water tank.
3. Flush unit with warm water and
de-scaler and sanitising solution.
4. Contact the supplier for
replacement part.
Bad odour
1. When the cooler is new / first used.
2. Unit has not been properly
maintained.
1. When the unit is used for the
very first time, an odour can
sometimes be noted. This will
only last several hours and then
clear. Operate in a well-
ventilated area upon first use.
2. Clean the unit including the
cooling pads with a non-toxic
cleaning solution.
Storage & Transport –
Correct storage and recommended storage both short term and long term.
Ensure the product is thoroughly emptied and dry before handling and storage. Dry using a lint-free
cloth
Remove cooling pads and rinse with fresh clean warm water to remove any dust or debris. Leave them
to dry thoroughly before fixing them back in the unit.
Coil the mains cable onto the integral cable management and retain in position for protection.
Where possible retain and use the original packaging for prolong periods of storage. If this is not
possible use a clean cloth or dust sheets.
Earth Symbol

Page 7of 8
www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
Specification Data Table
Model
Elite BCE45LV2
Elite BCE60LV2
Power Supply (V)
230VAC 50Hz
230VAC 50Hz
Power – Motor (W)
120
150
Power – Pump (W)
18
18
Air Volume (m³/h)
4500
4700
Cooling Effect (°C)
4-12
4-12
Cooling Area (m²)
30-50
30-60
Size (mm) WxDxH
680x420x1050
680x420x1250
Noise (dBA)
≤40
≤45
Weight (kg)
15.5
18.5
Fan Type
Axial
Axial
Control Interface
Manual Controls
Manual Controls

www.hscgroupuk.co.uk
The Hire Supply Company (UK) Limited
SALES Nottingham:
0115 9461988
SALES London: 0208 8308333
SALES Nottingham: sales@hscgroupuk.co.uk
SALES London: sean@hscgroupuk.co.uk
ENVIRONMENTAL PROTECTION: Please recycle any unwanted materials as opposed to disposing them as
general waste. It is recommended the original packaging is retained and used to store the product when
not in use for prolonged periods of time. If this is not applicable ensure the materials are sorted and
recycled in accordance with local regulations.
SPECIFICATION CHANGE: It is out policy to continually improve products to ensure these meet the rigours
of the industry we serve. Therefore, as such we reserve the right to alter specifications, data and
components parts without prior notice.
WARRANTY: All Elite products come with a 1-year warranty from date of purchase, proof of which will be
required in the event of any claim.
IMPORTANT: No liability will be accepted for the incorrect use of this product.
This manual suits for next models
1
Table of contents
Other HSC Freezer manuals
Popular Freezer manuals by other brands

Beko
Beko FNE 1074N user manual

Whirlpool
Whirlpool EH101FXR Use and care guide

Baltimore Aircoil Company
Baltimore Aircoil Company PT2 Series Rigging & Assembly Instructions

FrostEmily
FrostEmily VIPR 33 instructions

AEG
AEG SKB388F1AS Installation instruction

Frigidaire
Frigidaire FFU21D7H Factory parts catalog