ASSISTANCE
18
GB
Service Manual
MOON - 2006
Linguage
English
Edition
2006.06.12
FAULT CORRECTIVE ACTIONSCAUSE
- Check for water leaks that may affect connector J9 causing the
relative contacts to short;
- Check the motor terminal board (any problems due to aggression
caused by manufacturing chemical residues may cause short-
circuits);
- Replace card.
- Check motor if blocked;
- Check the tacho generator winding and check that there is an
impedance value of between 115 and 170 Ωon the wiring connector
J9 between pins 1and 2. In the case of direct current or alternative
current check the wiring between pins 1and 2of J9 relative to the
tacho generator. With a three-phase motor, make sure there is ohm
continuity between J9 pins 6and 7;
- Replace motor;
- Replace card.
- Check efficiency of contacts on connector J8 on PCB;
- Check NTC ensuring that the impedance value at ambient temperature
on wiring connector J8 , pins 11 and 12 , is approximately 20 KΩ;
- If the measurement is incorrect, check J8/NTC wiring continuity.
Check the same parameter directly on the NTC.
- Replace NTC;
- Replace card.
- Check efficiency of contacts on connector J3 on PCB;
- Check condition of pressure switch by checking for impedance on
wiring connector J3 pins 2and 4(impedance should be measured
only with tub empty) and between pins 2 and 1 (impedance must be
present only with water in tub to above the level of half-way up the
door);
- Check wiring of connector J3/pressure switch;
- Replace pressure switch;
- Replace card.
- Check efficiency of contacts of connector J9 on PCB, checking for
the presence of 220V between pins 8and 9;
- Check that pump is receiving power;
- Check pump filter + drain outlet to building wall connection;
- Renew pump;
- Replace card.
- Check efficiency of contacts on connector J3 on PCB;
- Check on connector J3 pins 5and 6for continuity of the wash heating
element. The 1800W 230V heating element has a value of 25 Ω;
- Check pressure switch connector J3 pins 2and 3: no impedance
value must be detected (common with full);
- Check pressure switch connector J3 pins 2and 3: an impedance
value must be present;
- Replace pressure switch;
- Renew heating element;
- Replace card.
F01
Motor driving triac short-
circuit
Motor tripped, motor tacho
generator open or short
circuited
NTC washing sensor open
/ short circuit, or wash
heating element relay
contacts sticking (signalled
at time of full tub)
F03
F02
F04
Simultaneous presence of
empty + overflow indications.
If the pressure switch contact
sticks on the empty setting,
the machine loads water
until reaching the overflow
level. The drain pump is
automatically started when
the overflow contact trips.
Pressure switch empty
condition not reached.
F05
Fault indication leds flash together with programme button leds.
No power draw of wash
heating element (signalled
only with pressure switch
on empty).
F07