Inoteska ITX 482 03.2 PVR Operator's manual

AUTODIALER
PRODUCT DOCUMENTATION

ITX 482 03
Autodialer 1
TABLE OF CONTENT
PRODUCT OVERVIEW ............................................................................................. 2
1). FEATURES........................................................................................................ 2
2). SPECIFICATIONS............................................................................................. 3
3). JUMPERS LAYOUT ON BOARD ...................................................................... 5
4). CONNECTORS DESCRIPTION........................................................................ 7
4.1). DUAL X.21 DCE MODULE (ITP 136 20)..................................................... 9
4.2). DUAL UDI MODULE................................................................................. 11
5). INSTALLATION AND SETUP.......................................................................... 12
6). TECHNICAL PARAMETERS........................................................................... 13
7). AUTODIALER ITX 482 03.X PVR.................................................................... 14
7.1). FRONT PANEL LED DESCRIPTION........................................................ 15
MANAGEMENT SOFTWARE................................................................................... 16
1). CONFIGURATION........................................................................................... 16
1.1). CARRIER PROPERTIES.......................................................................... 21
1.2). ROUTING & CARRIERS & TIME ZONES TABLE .................................... 24
1.3). ROUTING EXCEPTIONS.......................................................................... 28
1.4). CLIP EXCEPTIONS.................................................................................. 29
1.5). PARAMETERS.......................................................................................... 31
1.6). E1 SETTINGS........................................................................................... 35
1.7). TIMESLOT PROPERTIES ........................................................................ 37
1.8). AOC .......................................................................................................... 39
1.9). CLI FOR REMOTE ACCESS CALLS........................................................ 42
1.10). CUSTOMER DATABASE........................................................................ 43
1.11). INCOMING CALL REDIRECTION FROM PSTN .................................... 44
1.12). MFC R2 SETTING.................................................................................. 45
1.13). SYNCHRONIZATION.............................................................................. 46
1.14). IDENTIFICATION.................................................................................... 47
2). DIAGNOSTICS AND STATISTICS.................................................................. 48
2.1). E1 STATUS............................................................................................... 48
2.2). LISTING MESSAGES ............................................................................... 49
2.3). CONNECTION STATUS........................................................................... 50
2.4). TIMESLOT STATUS OF CAS SIGNALING*............................................. 51
2.5). ACTUAL TIMESLOTS STATUS................................................................ 52
2.6). STATISTICS –OVERALL AND BY CARRIERS ....................................... 53
2.7). ERROR DUMP.......................................................................................... 55
2.8). CALLBACK................................................................................................ 56
3). CHANGE OF BASIC CONFIGURATION......................................................... 57
4). PROGRAMMING NEW FIRMWARE............................................................... 58

ITX 482 03
Autodialer 2
PRODUCT OVERVIEW
1). FEATURES
Product name: Autodialer
Model: ITX 482 03
Manufacturer:
INOTESKA, s.r.o., Priemyselná 221/6, Podtureň-Roveň, 033 01 Liptovský Hrádok, Slovakia
Placement: In supervised area
Size: 43,5 x 104 x 220 mm (HxWxD)
Environmental conditions: 0o C to 55o C, 20% to 75% relative atmospheric humidity
Storage: -10o C to 60o C, 20% to 75% relative atmospheric humidity
Setup on transmission path between the PBX and the Public Exchange
3 x E1 interfaces (120 / 75 Ohm, RJ 45 / BNC connectors)
Optional call routing to E1-C
E1 interface with CAS R2 MFC signalling
PRA ISDN DSS1 interface
Optional change of signalling from R2 MFC to DSS1 and vice versa
Synchronous data interfaces X.21, V35, V.36, RS 530, V.24 , 10 Base-T for DATA
Call statistics
E1-A/B/C interface diagnostics
Scanning and re-routing of up to 30 voice channels to E1 - C
1400 re-routing conditions
200 barred numbers (exceptions)
19 spaces for carrier number and 19 spaces for user ID number
Routing of calls, Up to 8 carriers via PSTN
Pause length setting in seconds
Optional pause insertion in PIN/dialed string
Optional insertion of # or * at any position in ID number
Real or pseudo charging (800 routing codes, 20 charging tables, real time clock)
Dialling tone 425 Hz and 1100/1633 Hz (DTMF A-D) tone detection for real charging
Configuration via PC with V.24 interface
Saving of configuration to PC
Change of configuration and firmware
Remote configuration via internal ISDN modem, external analog modem or via TCP/IP
10/100 BaseT
Optional dedicated selected channels for external data transfers
Bypass connection if the device is off or out of order
Power supply adapter AC/DC 230 V / 5 V, max. input 5 VA

ITX 482 03
Autodialer 3
2). SPECIFICATIONS
Specification
Interfaces
Characteristics
E1 connectors
E1-C
X.21
UDI
Eth
P
VR
RJ45
BNC
ITX 482 03.2 PVR
-
-
-
-
ITX 482 03.2 R
-
-
-
ITX 482 03.3 PVR
-
-
-
ITX 482 03.3 R
-
-
ITX 482 03.4 PVR
-
-
-
ITX 482 03.4 R
-
-
ITX 482 03.6
PVR
-
-
-
-
-
ITX 482 03.6 R
-
-
-
-
ITX 482 03.7 PVR
-
-
-
ITX 482 03.8 PVR
-
-
-
- Basic Configuration features, -- Features not possible to utilize
RJ 45 - connector for E1 interface 120 Ohm
BNC - connector for E1 interface 75 Ohm
E1-C - can be defined as PRA ISDN resp. CAS R2 MFC.
X.21 –data interface
UDI –universal data interface
Eth –interface Ethernet 10BT
P–CAS R2 MFC / PRA DSS1 signalling converter
VR –voice routing
The necessary data interface is achieved with cable reduction. Please order a
cable:
ITK 522 08 Cable UDI / X.21 DCE ITK 522 13 Cable UDI / V.36 DTE
ITK 522 09 Cable UDI / X.21 DTE ITK 522 14 Cable UDI / V.24 DCE
ITK 522 10 Cable UDI / V.35 DCE ITK 522 15 Cable UDI / V.24 DTE
ITK 522 11 Cable UDI / V.35 DTE ITK 522 16 Cable UDI / RS 530 DCE
ITK 522 12 Cable UDI / V.36 DCE ITK 522 17 Cable UDI / RS 530 DTE
Standard cable length is 1m. Different lengths are available upon request.
Warning:
For proper functioning of the device and conformation with the warranty conditions
we recommend the use of the standard cables, supplied with the device.
Note:
The necessary number of E1 interfaces is activated in accordance with the type of
Autodialer.

ITX 482 03
Autodialer 4
Autodialer ITX 482 03 is fitted in a case sized 237 x 220 x 43.5 mm ( h x d x w ).

ITX 482 03
Autodialer 5
3). JUMPERS LAYOUT ON BOARD
PR1 Hardware jumper (always 1-2)
PR2 Hardware jumper (always disconnected)

ITX 482 03
Autodialer 6
Impedance switching
120 Ohm 75 Ohm
------------------------------------E1- A ---------------------------------
PR 101 n.c. 1-2
PR 102 n.c. 1-2
PR 103 n.c. 1-2
----------------------------------- E1- B ---------------------------------
PR 104 n.c. 1-2
PR 105 n.c. 1-2
PR 106 n.c. 1-2
------------------------------------ E1- C --------------------------------
PR 107 n.c. 1-2
PR 108 n.c. 1-2
PR 109 n.c. 1-2
------------------------------------ E1- D ---------------------------------
PR 110 n.c. 1-2
PR 111 n.c. 1-2
PR 112 n.c. 1-2
--------------------------------------------------------------------------------
n.c. –Jumper not connected
Warning:
75 Ohm is non-standard output via RJ 45 connector

ITX 482 03
Autodialer 7
4). CONNECTORS DESCRIPTION
E1-A/B/C interface connectors
RJ 45 connector description
120 75
1 –input pin to ITX 482 03 ------- RX - RX
2 –input pin to ITX 482 03 ------- RX+ GND
3 –
4 –output pin from ITX 482 03 ------- TX - TX
5 –output pin from ITX 482 03 ------- TX+ GND
6 –
7 –
8 –
CONTROL connector for connecting ITX 482 03 with a PC
Cable description for connecting an external analog modem:
CONTROL V.24

ITX 482 03
Autodialer 8

ITX 482 03
Autodialer 9
4.1). DUAL X.21 DCE MODULE (ITP 136 20)
DTE interface is determined by cable:
ITK 522 07 X.21 DCE –extension cable
ITK 522 19 X.21 DTE –cable reduction
Cable ITK 522 07 –extension cable for X.21 DCE
CANNON -
D15 M
Signal
Pairing
Colour designation
of the wires
Signal
Cannon -
D15 F
1
-
-
-
1
2
TXA
White (Orange)
TXA
2
3
CSA
White (Green )
CSA
3
4
RXA
White (Blue )
RXA
4
5
RCA
White (Brown )
RCA
5
6
TCA
White ( Gray )
TCA
6
7
7
8
-
-
-
8
9
TXB
Orange (White)
TXB
9
10
SCB
Green (White)
SCB
10
11
RXB
Blue (White)
RXB
11
12
RCB
Brown (White)
RCB
12
13
TCB
Gray (White)
TCB
13
14
-
-
-
-
15
-
-
-
-
cover
-
-
shield
-
cover
-Paired wires
Supplied cables have standard length of 1m. Different lengths are available upon
request.
Cable ITK 522 19 –reduction for X.21 DTE

ITX 482 03
Autodialer 10
CANNON
D15 M
Signal
Pairing
Colour designation
of the wires
Signal
Cannon
D15 M
1
-
-
-
1
2
TXA
White (Orange)
TXA
4
3
CSA
White (Green)
CSA
5
4
RXA
White (Blue)
RXA
2
5
RCA
White (Brown)
RCA
3
6
TCA
White (Gray)
TCA
7
7
RTCA
White (Red)
RTCA
6
8
GND
Yellow
GND
8
9
TXB
Orange
TXB
11
10
SCB
Green
SCB
12
11
RXB
Blue
RXB
9
12
RCB
Brown
RCB
10
13
TCB
Gray
TCB
14
14
RTCB
Red
RTCB
13
15
-
-
-
-
cover
-
shield
-
cover
-Paired wires
Supplied cables have standard length of 1m. Different lengths can be specified in
the order.
Cable Termination
TI –Termination Impedance
TI 150 TI 6 kTI 150 TI 6 k
PR 20 1-2 n.c. PR 10 1-2 n.c. R
PR 21 1-2. n.c. PR 11 1-2 n.c. I
PR 22 1-2 n.c. PR 12 1-2 n.c. S
R –Data Receive
S –Synchronisation Receive
I –Control signal

ITX 482 03
Autodialer 11
4.2). DUAL UDI MODULE
UDI –V.35, V.36, RS 530 V.24, X.21 (universal data interface)
- Module ITP 136 14 with dual UDI interface
- Seperate UDI interfaces are configured with the management software
Cables:
The required interface is achieved with cable reduction.
ITK 522 08 Cable UDI / X.21 DCE
ITK 522 09 Cable UDI / X.21 DTE
ITK 522 10 Cable UDI / V.35 DCE
ITK 522 11 Cable UDI / V.35 DTE
ITK 522 12 Cable UDI / V.36 DCE
ITK 522 13 Cable UDI / V.36 DTE
ITK 522 14 Cable UDI / V.24 DCE
ITK 522 15 Cable UDI / V.24 DTE
ITK 522 16 Cable UDI / RS 530 DCE
ITK 522 17 Cable UDI / RS 530 DTE
Supplied cables have standard length of 1m. Different lengths can be specified in
the order.
Warning:
For proper functioning of the device and conformation with the warranty conditions
we recommend the use of the standard cables supplied with the device.

ITX 482 03
Autodialer 12
5). INSTALLATION AND SETUP
Autodialer should be placed in proximity to the PBX so that the E1-A interface
is connected to the PBX , E1-B to the PSTN and E1-C (if present) to a direct E1
trunk to the carrier.
Device is powered by AC/DC 230V/ 5V adapter.
Fixation method:
Autodialer comes in two installation versions:
Wall version
Desktop version
Wall mounting:

ITX 482 03
Autodialer 13
6). TECHNICAL PARAMETERS
G.704 interface:
Line code: HDB3
Signalling: DSS1 ISDN PRA
CAS R2 MFC
Impedance: 120 Ohm (non-standard 75 Ohm via RJ 45)
X.21 interface:
Connector 15 pin D15 F
UDI interface: Connector 15 pin D15 M
Device synchronisation –user defined:
-to E1-B
-to E1-C
Current: 1 A
Powering: Converter 230V / 5V, 50 Hz
Maximum output: 5VA
Size: 43.5 x 237 x 220 mm (h w d)
Weight: 2 kg

ITX 482 03
Autodialer 14
7). AUTODIALER ITX 482 03.X PVR
Autodialer is a device that re-routes outgoing calls from the PBX to a specified
carrier. It is placed between the PBX with the R2 MFC/ISDN signalling and the
Public Network. Routing is made on the basis of analysing of outgoing call from the
PBX signalling. If the customer matches the "trigger code" (incoming call from
Autodialer’s point of view), this number is re-routed to the preferred carrier, who
services the call further. Telephone numbers not matching to any of the re-routing
conditions are transparently passed through to the Public Network. . In case the
customer doesn´t match the "Intercept command", this number is transparently
passed through to the Public Network.
Moreover, autodialer enables the interconnection of network devices such as
routers, multiplexers, etc. and to insert DATA to channels of E1-C interface
(dedicated channel / dedicated private line) which is connected directly to the
specified carrier. It is necessary to separate voice and DATA on the carrier´s side. It
is possible to use the ITX 481 2x.3 or DyMUX products from INOTESKA for this
purpose.
Autodialer ITX 482 03.X PVR converts MFC R2 signalling to DSS1 ISDN PRA
signalling and vice versa. Autodialer can transmit:
E1-A/B/C –PRA or CAS
Voice and fax
Metering pulses
Dialling
Data channels
The type of signalling on the separate interfaces is user defined and can be
changed from the mangement software. Autodialer allows the connection of a router
via a data interface, and transmission of the data to selected channels in E1-C.

ITX 482 03
Autodialer 15
7.1). FRONT PANEL LED DESCRIPTION
Errors indicated by separate LEDs:
E1-A red - D7, D6, D5, D4, D3, D2, D1 yellow D0
E1-B red - D7, D6, D5, D4, D3, D2, D1 yellow D0
E1-C red - D7, D6, D5, D4, D3, D2, D1 yellow D0
E1-D red - D7, D6, D5, D4, D3, D2, D1 yellow D0
D7 –Loss of Signal LOS –Loss of signal on link level - E1 interface not connected
D6 –Alarm Indication Signal AIS –Signal is constant and data contain value Log1
D5 –Loss of Frame Alignment LFA –Synchronization error in the 0-th channel
D4 –Receive Remote Alarm RRA –Remote device alarm
D3 –Frame Error Counter FEC –Indicates error rate > 10 –3
D2 –Receive Timeslot 16 Loss of Signal TS16LOS –Receive timeslot 16 does
not contain signalling
D1 –Loss of Multiframe Synchronization LOMFS –CRC 4 multiframe structure
error , reset will follow if two CRC multiframes are received in time interval n x 2 ms
(n = 1, 2, 3 ...) –CAS signalling only
D1 –Datalink layer not active –Link layer error –ISDN DSS1 signalling only
D0 –Slip Detection Indicator SDI –Indicates positive slip if device clock has higher
frequency than the clock signal received, and negative slip the frequency is lower

ITX 482 03
Autodialer 16
MANAGEMENT SOFTWARE
1). CONFIGURATION
ITX 482 03 can be configured:
- Locally, from connected PC via PC V.24 interface
- Remotely
-Via analog modem connected locally to the device
-Via BRA ITX 481 51 modem and utilization of Autodialer’s internal modem
-By call to internal modem with dial in subaddress
Software installation:
1. Put the CD disk into the PC (working under Windows 95 or higher).
2. Start - Run Setupxx.exe, where xx is the software version
3. Click OK
Running the management software:
Run M8203Axx.exe or
Double-click shortcut on Desktop
The software version can be found in: Main Menu –Info.
After running the management software a password prompt will be displayed. The
factory set password is inoteska. After typing the right password and pressing OK, a
window for communication with device will appear.
It is necessary to press the ‘Identification’ speed button for reading the
identification of the device.
In case of error, please check:
System power source
Password correctness
Device address 0-0-0-0 –local connection (this address can be changed: first
number from interval 0 - 239, other three numbers from interval 0-255)
Manager address 251-1-1-1 (this address can be changed: first number from
interval 240 –254, other three numbers from interval 0-255 )
Serial port connection
Cable between ITX 482 03 and PC
Baud Rate between ITX and PC - 19200 Bd. In case communication is done via
another Inoteska device, Baud Rate is set as for the device next to autodialer.
Factory settings
System parameters are set to their factory defaults for standard interface with R2
MFC or ISDN. If necessary, the configuration can be returned to the factory default
by loading the file ‘default.dat’.
After running the management SW there is a window for communication settings
displayed on the screen.

ITX 482 03
Autodialer 17
These parameters are set for the first access to device.
Access type –type of access to the device:
COM –local access to the device via device address in format X.X.X.X . This way
it is also possible (if it is supported by device) to access the remote device via
fixed line which connects these two devices. By setting the universal device
address 0.0.0.0 –connection COM transparent
COM Transparent –transparent communication only with locally connected
device
TCP/IP - remote access to the device via IP address and device address. After the
connection to the device in IP network, it is possible to connect to the remote
device via fixed line which connects these two devices.
TCP/IP Transparent –remote access to the device connected to IP network
Device address - 0-0-0-0 –local connection (this address can be changed: first
number from interval 0 - 239, other three numbers from interval 0-255)
Device address can be changed, if necessary in Main menu –Options –Change
of device address. Usually, device address is set when starting the configuring.

ITX 482 03
Autodialer 18
Manager address - 250-1-1-1 (this address can be changed: first number from
interval 240-254, other three numbers from interval 0-255)
- address 255-x-x-x is reserved for the supervision centre
COM Port –selection of communication port
BaudRate –Baud speed between ITX 482 03 and PC, for local connection to device
–19200 Bd, for remote connection –depends on the device next to autodialer
Ethernet setting
If Autodialer is connected to the ethernet network, it is enabled for remote
configuration. Autodialer will log to the set IP address and parameters. Click Find
will list all the available devices in the network with their MAC address.
All windows share the same Main menu and Speed buttons.
Main menu:
File –Open –Save –Exit
Options
Password –Changes access password for ITX 482 03
–default “inoteska”
Time&Date –See chapter ‘AOC ‘(Charging)

ITX 482 03
Autodialer 19
Change Configuration –See chapter ‘Change of Configuration’
Change of device address –enables to change device address
Language –English / Slovak / Czech
Communication
Read / Write –Read/Write settings from/to ITX 482 03
Terminal –Accessible only with Supervisor password
Programmer –Program new firmware in ITX 482 03
Modem –See chapter ‘Remote Configuration Via Modem’
Identification –List of activated features and device serial number
Ethernet setting - Ethernet setting for autodialer remote configuration
Windows
See chapters ‘Carrier Properties’, ‘ Carriers table ‘, ´Time
zones table´, ‘Routing Table’, ‘Routing Exceptions’, 'CLIP
Exceptions', ‘Parameters’, 'Timeslot properties', ‘AOC’,
‘E1 Settings’, ‘Customer Database’, ‘Incoming Call
Redirection’ ,‘Data Interface’, ‘ CLI for remote access
calls‘, ´MFC R2 setting´, ‘Synchronization’, ‘Assignment of
timeslots for customer’ for details
Diagnostics
E1 Status –Status of E1 trunks
Listing Messages –Signalling error diagnostics (R2 MFC)
Timeslot Status of CAS signalling –Status of separate timeslots (R2 MFC)
Error dump –display of errors downloaded via supervision centre
Actual timeslots status –display of current timeslots status
Connection status –current status of connection
Callback –diagnostic call to carrier
Statistics
Overall statistics –Summary call statistics
Statistics by Carriers –Call statistics for individual carriers
Info –Displays the version of the management software
Help –Help on installation, configuration and support
Speed buttons:
New
Open -Reads settings from *.dat file
Save -Saves settings from screen to *.dat file
Read - Reads configuration from device
Write -Writes configuration to device
Modem - Enables Autodialer´s remote configuration.
Programmer -Used for loading new firmware to device
Access type - Enables to change the access type to device, not to change
device address
This manual suits for next models
9
Table of contents