Assembly, mounting and commissioning instructions
1. Fix the INPRO MICRO DOMESTIC to the wall:
- Put the plastic lugs in place.
- Tighten the screws (not too tighten)
2. Connect the flexible intake pipe and driving flexible
pipe racords to the copper pipe (8 x 10).
3. Electrical connection procedure, receiving the mains
electrical supply from burner.
- Connect the mains supply of INPRO MICRO
DOMESTIC to a burner 230 V output which works
only when the burner pump is "ON".
4. During first oil supply to burner, it is necessary to take
out the existing air in the pipe, before connecting to
burner flexible.
Electrical Diagram
Power supply
from burner
L
NNL
1. Main tank
2. Level gauge probe
3. Floating suction
4. Ventilation tee
5. Manhole
6. Intake pipe
7. Filter
8. Solenoid pump
9. Burner
SUCTION HEAD 1,5 m
HORIZONTAL LENGTH DISTANCE
FROM TANK TO GP (m)
DELIVERY VERTICAL HEIGHT FROM GP TO BURNER (m)
FLOW (l/h)
SUCTION HEAD 2 m
HORIZONTAL LENGTH DISTANCE
FROM TANK TO GP (m)
DELIVERY VERTICAL HEIGHT FROM GP TO BURNER (m)
FLOW (l/h)
SUCTION HEAD 1,5 m
HORIZONTAL LENGTH DISTANCE
FROM TANK TO GP (m)
DELIVERY VERTICAL HEIGHT FROM GP TO BURNER (m)
FLOW (l/h)
SUCTION HEAD 3 m
HORIZONTAL LENGTH DISTANCE
FROM TANK TO GP (m)
DELIVERY VERTICAL HEIGHT FROM GP TO BURNER (m)
FLOW (l/h)
Example: - Suction head between the tank bottom and the desired position for the INPRO MICRO DOMESTIC of 2 m (so
please read second diagram above).
- Pipe length (horizontal) of 30 m between the tank and the INPRO MICRO DOMESTIC.
- After the INPRO MICRO DOMESTIC till the burner there is a difference in height of 10 m.
- The results in a maximum power of 9 l/h.
NEVER INSTALL THE INPRO MICRO DOMESTIC IN CONTINUOUS WORKING WITHOUT BURNER CONSUMPTION!