Interlogix TruVision TVB-2403 Instruction sheet

TruVision High Definition
TVI Camera Configuration
Manual
TVB
-2403/TVB-4403
TV
B-2404/TVB-4404
TV
D-2403/TVD-4403
TV
D-2404/TVD-4404
P/N 1072940-EN • REV A • ISS 10MAR15

Copyright
©
2015 United Technologies Corporation,
Interlogix is part of UTC Building & Industrial Systems,
a unit of
United Technologies Corporation. All rights reserved.
Trademarks and
patents
T
rade names used in this document may be trademarks or
registered
trademarks of the manufacturers or vendors of the
respective products
.
Manufacturer
I
nterlogix
2955 Red Hill Avenue, Costa Mesa, CA 92626
-5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Ne
therlands
Contact information
For contact information
, see www.interlogix.com or
www.utcfssecurityproducts.eu
.
Customer suppor
t
www.interlogix.com/customer
-support

TruVision High Definition TVI Camera Configuration Manual 1
Content
Introduction 2
Programming 2
Menu 4
Video Standard 4
Language 4
Setup 4
Scene 4
Lens 4
Exposure 5
Backlight 5
White Balance (WB) 5
Day & Night 6
NR 6
Special 6
Adjust 7
Reset 8

2 TruVision High Definition TVI Camera Configuration Manual
Introduction
This is the configuration manual for following camera models:
TVB-2403 (1080P TVI Bullet Camera, Fixed Lens, IR, PAL)
TVB-4403 (1080P TVI Bullet Camera, Fixed Lens, IR, NTSC)
TVB-2404 (1080P TVI Bullet Camera, VF Lens, IR, PAL)
TVB-4404 (1080P TVI Bullet Camera, VF Lens, IR, NTSC)
TVD-2403 (1080P TVI Dome Camera, Fixed Lens, IR, PAL)
TVD-4403 (1080P TVI Dome Camera, Fixed Lens, IR, NTSC)
TVD-2404 (1080P TVI Mini Dome Camera, VF Lens, IR, PAL)
TVD-4404 (1080P TVI Mini Dome Camera, VF Lens, IR, NTSC)
Programming
Once the camera hardware has been installed, the camera can then be
configured using the built-in OSD button or an OSD controller (purchased
separately).
You can also configure the camera settings via a TVI DVR, select PTZ protocol
as TruVision Coax and click the menu button to call the menu.
Note:
Interlogix offers two different versions of the OSD Controller: the TVS-C100
controller and the TVS-C200 controller. Please choose the corresponding
controller by referring to product datasheets.
The cameras listed in “Introduction” section support TruVision Coax OSD control
protocol and require the TVS-C200 for OSD control.
The TVS-C200 is used to program the camera’s 960H CVBS output, not for the
TVI video output. Programming the camera’s TVI output can be done via a TVI
DVR.
The TVS-C200 has four buttons for the camera functions selection and control.
Table 1 below lists the OSD control button functions and describes their use.

TruVision High Definition TVI Camera Configuration Manual 3
Figure 1: TVS-C200 coax controller
1. Indicator light
2. Arrow keys
3. OK button
The Setup menu provides access to the camera configuration options.
Before using the controller, please check to ensure that the controller has power.
Two AAA batteries are required for the controller to work properly.
1. Connect a video monitor to one of the BNC connectors of the controller.
2. Connect the camera’s 960H CVBS output to the other BNC connector
3. Press the OK button for few seconds to display the Setup menu. See Table 1
for instructions on how to move the cursor.
Table 1 Using the OSD control button
Button
direction Description
Up
Moves the cursor upward to select an item
Left
Moves the cursor left to select or adjust the parameters of the selected
item.
Right
Moves the cursor to the right to select or adjust the parameters of the
selected item.
Down
Moves the cursor downward to select an item.
OK
Press the red button for few seconds to display the Setup menu. If the
selected item has its own menu, press the button to enter a submenu.

4 TruVision High Definition TVI Camera Configuration Manual
Menu
Video Standard
Select PAL or NTSC as the video standard.
Language
Select one of the languages available: English, Japanese, CHN1, CHN2, Korean,
German, French, Italian, Spanish, Polish, Russian, Portuguese, Dutch, Turkish,
Hebrew or Arabic.
Setup
Scene
Select Indoor, Outdoor, Indoor 1 or Low-light as the working environment.
Lens
The camera is equipped with a fixed lens.

TruVision High Definition TVI Camera Configuration Manual 5
Exposure
SHUTTER: AUTO, 1/25, 1/50, FLK, 1/200, 1/400, 1/1k, 1/2k, 1/5k, 1/10k, 1/50k,
x2, x4, x6, x8, x10 and x15 are selectable.
AGC: Set the AGC value from 0 to 15.
SENS-UP: Set the SENS-UP to OFF or AUTO.
BRIGHTNESS: Set the brightness value between 1 and 100.
D-WDR: Set the D-WDR to ON to improve the image quality or to OFF to disable
the function.
DEFOG: Set the defog function to ON to enable the function. Position, size, and
defog gradation are configurable.
Backlight Compensation (BLC)
GAIN: Set the BLC gain to High, Middle, or Low.
AREA: Press the up/down/left/right buttons to define the BLC position and size.
Select RET or AGAIN to go back to the BLC menu or redefine the BLC area.
Default: Restore the BLC settings to default.
HSBLC: Select an HSBLC area. Set the DISPLAY status to ON. Press the
up/down/left/right buttons to define the area position and size. Set the HSBLC
LEVEL between 0 and 100. Select ALL DAY or Night for the HSBLC mode. Set
the BLACK MASK status to ON or OFF.
White Balance (WB)
Select INDOOR, OUTDOOR, MANUAL, ATW (Auto-tracking White Balance), or
AWC→SET.

6 TruVision High Definition TVI Camera Configuration Manual
Day & Night
Select Color, B/W, or EXT as the DAY and NIGHT switches.
NR
2D NR: Set 2D NR status to ON or OFF.
3D NR: Set the SMART NR status to ON and adjust the 3D SMART NR
sensitivity range between 0 and 100.
Set the LEVEL range between 0 and 100. Set the START.AGC level to the
threshold to enable AGC. Set the END.AGC level to the threshold to disable
AGC.
Special
Camera Title: Edit the camera title.
D-Effect:
FREEZE: Set the freeze function to ON or OFF.
MIRROR: Select OFF, MIRROR, V-FLIP, or ROTATE.
D-ZOOM: Define the zoom area by configuring the position from PAN &
TILT.
SMART D-ZOOM: The D-Zoom area, sensitivity and time are configurable.
NEG.IMAGE: Set the NEG IMAGE to ON or OFF.

TruVision High Definition TVI Camera Configuration Manual 7
Motion:
Select a MOTION area. Set the DISPLAY status to ON or OFF. Press the
up/down/left/right buttons to define the position and size of the area. Set the
SENSITIVITY between 0 and 60. Set the MOTION VIEW status to ON or OFF.
Privacy Masking:
Select a PRIVACY area. Set the DISPLAY status to INV, MOSAIC, COLOR, or
OFF. Press the up/down/left/right buttons to define the position and size of the
area.
Defect:
Adjust LIVE DPC, STATIC DPC and Black DPC.
Version:
You can check the software version of the device.
Adjust
Sharpness: Adjust the sharpness between 0 and 15.
Monitor: Select CRT or LCD.
LSC: Set the LSC status to ON or OFF.

8 TruVision High Definition TVI Camera Configuration Manual
Reset
Reset all the settings to the default.
EXIT: Press OK to exit the menu.
Other manuals for TruVision TVB-2403
1
This manual suits for next models
7
Table of contents