IPEXCB Installaon and
Conguraon Guide

IPEXCB Installaon Guide
2
1. Read these instrucons – All the safety and operang instrucons should be read before this product is operated.
2. Keep these instrucons – The safety and operang instrucons should be retained for future reference.
3. Heed all warnings – All warnings on the appliance and in the operang instrucons should be adhered to.
4. Follow all instrucons – All operang and use instrucons should be followed.
5. Do not use this apparatus near water – The appliance should not be used near water or moisture – for example, in a wet
basement or near a swimming pool, and the like.
6. Clean only with a dry cloth.
7. Do not block any venlaon openings. Install in accordance with the manufacturer’s instrucons.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers)
that produce heat.
9. Do not defeat the safety purpose of the polarized plug. A polarized plug has two blades with one wider than the other.
The wide blade or the third prong is provided for your safety. If the provided plug does not t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched parcularly at the plugs, convenience receptacles, and at the
point where it exits from the apparatus.
11. Only use aachments/accessories specied by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the
apparatus. When a cart or rack is used, use cauon when moving the cart/ apparatus combinaon to avoid injury
from p-over.
13. Unplug the apparatus during lighng storms or when unused for long periods of me.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any
way, such as; the power-supply cord or plug is damaged, liquid has been spilt or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. CAUTION: Servicing instrucons are for use by qualied service personnel only. To reduce the risk of electric shock, do
not perform any servicing other than that contained in the operang instrucons unless you are qualied to do so.
16. Do not install this equipment in a conned or built-in space such as a book case or similar unit. The equipment must
remain in well venlaon condions. Venlaon should not be impeded by covering the venlaon openings with items
such as newspaper, table-cloths, curtains etc.
17. WARNING: Only use aachments/accessories (such as the baery etc.) specied or provided by the manufacturer.
18. WARNING: Refer to the informaon on the underside of the enclosure for electrical and safety informaon before
installing or operang the apparatus.
19. WARNING: To reduce the risk of re or electric shock do not expose this apparatus to rain or moisture. The apparatus
shall not be exposed to dripping or splashing and objects lled with liquids, such as vases, shall not be placed on apparatus.
20. CAUTION: Danger of explosion if baery is incorrectly replaced. Replace only with the same or equivalent type.
21. WARNING: The baery shall not be exposed to excessive heat such as sunshine, re or the like.
22. WARNING: The all-pole mains switch located on rear panel is used as the disconnect device, the switch shall remain
readily operable.
23. WARNING: DO NOT INGEST BATTERY. CHEMICAL BURN HAZARD.
24. Keep new and used baeries away from children. If the baery compartment does not close securely, stop using the
product and keep it away from children.
25. If you think baeries might have been swallowed or placed inside any part of the body, seek immediate medical
aenon.
Important Safety Instrucons

IPEXCB Installaon Guide
3
26. When the apparatus is not in use or during its relocaon, take care of the power cord and plugs; e.g. e up the power
cord with cable e or similar. The e must be free from sharp edges and the like that might cause abrasion of the power
cord. When put into use again ensure the power cord and plugs are not damaged. If any damage is found the power cord
and plugs should be replaced by items either specied by the manufacturer or that have same characteriscs as the original
items.
27. This lightning ash with arrowhead symbol within an equilateral triangle is intended to alert the user to the
presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sucient magnitude to
constute a risk of electric shock.
28. WARNING: To reduce the risk of electric shock, do not remove cover (or back) as there are no user-serviceable parts
inside. Refer servicing to qualied personnel.
29. The exclamaon point within an equilateral triangle is intended to alert the user to the presence of important
operang and maintenance instrucons in the literature accompanying the appliance.
30. Protecve earthing terminal. The apparatus should be connected to a mains socket outlet with a protecve
earthing connecon.
31. CAUTION: To prevent electric shock hazard, replace grille. (CSA 60065, clause 5.3A)
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR

IPEXCB Installaon Guide
4
Table of Contents
Important Safety Instrucons ������������������������������������������������������������������������������������������������������������������������������������2
Product Overview������������������������������������������������������������������������������������������������������������������������������������������������������6
Package Contents ������������������������������������������������������������������������������������������������������������������������������������������������������ 6
Front and Rear Panels������������������������������������������������������������������������������������������������������������������������������������������������7
Front Panel................................................................................................................................................................... 7
Rear Panel.................................................................................................................................................................... 7
Reset Buon ................................................................................................................................................................ 8
LAN Connecons.......................................................................................................................................................... 8
12V Connecon............................................................................................................................................................ 8
RS232 Connecons ...................................................................................................................................................... 8
Installaon Instrucons���������������������������������������������������������������������������������������������������������������������������������������������9
Basic Installaon.......................................................................................................................................................... 9
IPEXCB Web Browser Usage������������������������������������������������������������������������������������������������������������������������������������� 10
Logging into the web browser Graphical User Interface (GUI) .................................................................................. 10
Roung Video Signals ................................................................................................................................................ 14
Tesng Telnet API Commands.................................................................................................................................... 16
Changing IPLinx Encoder and Decoder IP Addresses ................................................................................................. 17
Changing IPEXCB IP Addresses................................................................................................................................... 18
Loading IPLinx Congurator Files............................................................................................................................... 18
User Management..................................................................................................................................................... 19
IPLinx Cong Soware Usage ���������������������������������������������������������������������������������������������������������������������������������� 20
Downloading IPLinx Congurator Soware............................................................................................................... 20
Making a PC Connecon............................................................................................................................................ 20
Running IPLinx Congurator Soware....................................................................................................................... 20
IPLinx Congurator Soware Overview..................................................................................................................... 21
Search for IPLinx Devices on the Network.................................................................................................................. 22
Renaming IPLinx Encoders and Decoders .................................................................................................................. 23
Creang Decoder Groups........................................................................................................................................... 24
Create a New Group ........................................................................................................................................... 24
Assigning an IPLinx Encoder or Decoder to a Group.................................................................................................. 25
Removing an IPLinx Encoder or Decoder ................................................................................................................... 26
Create a Video Wall Group ........................................................................................................................................ 27
Create a New Group ........................................................................................................................................... 27
Create a Video Wall Layout................................................................................................................................. 29
Video Wall Bezel Compensaon (5000 series only)............................................................................................ 33
Create a Matrix Layout within Video Wall Group ............................................................................................... 35
Verify Group Layouts .......................................................................................................................................... 35
Creang Combinaon Layouts for Large Video Wall Groups .............................................................................. 36
Remove a Matrix or Video Wall Layout ..................................................................................................................... 38
Remove a Layout................................................................................................................................................. 38
Remove a Video Wall.......................................................................................................................................... 39
Remove a Group ................................................................................................................................................. 39

IPEXCB Installaon Guide
5
2000-series Device Sengs ....................................................................................................................................... 40
IPEX2001 Video Sengs ..................................................................................................................................... 40
IPEX2002 Video Sengs ..................................................................................................................................... 42
5000-series Device Sengs ....................................................................................................................................... 43
IPEX5001 EDID Sengs....................................................................................................................................... 43
IPEX5001 RS232 (Serial) Sengs ........................................................................................................................ 43
IPEX5002 Video Sengs ..................................................................................................................................... 44
Saving and Loading Sengs...................................................................................................................................... 45
Upload Sengs to IPEXCB .................................................................................................................................. 45
Download Sengs from IPEXCB ......................................................................................................................... 46
Save Sengs to a File ......................................................................................................................................... 47
Load Sengs from a File..................................................................................................................................... 48
Batch Commands....................................................................................................................................................... 49
Changing IP Address Schemes on IPLinx Systems ............................................................................................... 50
CEC Display Power Conguraon........................................................................................................................ 52
RS232 Display Power Conguraon.................................................................................................................... 53
Using iPad or Windows Control APP with IPEXCB����������������������������������������������������������������������������������������������������� 54
Connecng Apple iPad to IPLinx System .................................................................................................................... 54
Hiding Groups ..................................................................................................................................................... 58
Connecng Windows Computer to IPLinx System...................................................................................................... 60
Syncing APP to IPEXCB IP Address.............................................................................................................................. 61
Technical Specicaons ������������������������������������������������������������������������������������������������������������������������������������������� 63

IPEXCB Installaon Guide
6
The IPLinx IPEXCB is an IP based control interface used to congure, manage and control IPLinx encoders and
decoders on a 1Gb managed Ethernet switch. Conguraon les for IPLinx systems are stored directly on the
IPECXB and is designed to work in conjuncon with the IPLinx iPad and Windows control APP for basic system
control. The IPEXCB oers a single point of connecon and control for third party IP or serial control systems and is
required for any IPLinx system that requires a video matrix or video wall system layout.
The IPEXCB integrates two Ethernet ports and two RS232 ports, oering integraon-friendly control features,
including a web GUI. LAN1 port (AV/PoE) is connected directly to the A/V network where all IPLinx devices reside.
LAN2 port (CTRL) can be connected to a control system network allowing the enre IPLinx matrix system to be
controlled by a third party IP control system. With the ability to assign separate IP addresses and subnets for
the two IPEXCB LAN ports, the A/V network trac is not forced to reside on a shared LAN that may compromise
bandwidth and data ow. The RS232 ports on the IPEXCB are also designed to oer a single point of control for
serial based control systems.
The IPEXCB can be congured with either the web browser graphical user interface (GUI) or IPLinx Congurator
which is a soware program that is used to congure IPLinx encoders / decoders on a 1Gb managed Ethernet
switch. The IPEXCB can automacally search and display encoders and decoders on the A/V network when using
the conguraon tool or web GUI. IPLinx Congurator can be downloaded from our website at www.libav.com on
the IPLinx IPEXCB product page under the SOFTWARE tab. Instrucons for using IPLinx Congurator are included
in this manual.
The IPEXCB is compable with all IPLinx 2000 and 5000 series IP devices.
Product Overview
Package Contents
1. Installaon Guide
2. Power Supply with US, UK, EU, and AU adapters
3. 6-pin Removable Screw Terminal
4. Device Labels

IPEXCB Installaon Guide
7
Front and Rear Panels
Front Panel
RESET
STATUS POWER
12
43
1. Label insert
2. Reset buon
3. Status indicator
4. Power indicator
Rear Panel
A. LAN1 (AV/PoE)
B. LAN2 (CTRL)
C. RS232 connecons
D. 12V DC power input
RS232
LAN1 (AV/PoE) LAN2 (CTRL) DC 12V
DEBUG
TX
RX
TX
RX
12V
G
A B C D

IPEXCB Installaon Guide
8
Reset Buon
LAN Connecons
12V Connecon
If a factory reset is required for the IPEXCB, press and hold the reset buon for ve seconds to restore the IPEXCB
to factory sengs. This reset will change the default IP address of the IPEXCB back to the factory default IP address.
LAN1(AV/PoE) is used to connect the IPEXCB to the Ethernet switch. The default IP address for LAN1 of the IPEXCB
is 169.254.1.1.
LAN2(CTRL) is used to connect the IPEXCB to a third party control system. The default IP address for LAN2 of the
IPEXCB is 192.168.11.243.
The 12V connecon on the right side of the RS232 connector can provide up to 500 mA of 12V DC to an external
device.
RS232 Connecons
The IPEXCB features two RS232 connecons: Debug and Control. The Debug connecon will only communicate
with the IPEXCB and will not control any encoders or decoders. The Control connecon will communicate with
IPLinx devices on the A/V network switch.
To use the RS232 control transport capabilies of the IPEXCB, connect the TX, RX, and ground control signal wires
to the middle RS232 connecons on the removable 6-pole terminal block. Consult the manual of the control device
to determine which pins the TX and RX signals are carried on. Be sure to always connect TX to RX and RX to TX.
The RS232 control ports require a standard straight-through serial cable for operaon. The default sengs for the
RS232 ports are:
• Debug connecon: 115200 baud, 8 Data Bits, 1 Stop Bit, Parity = none
• Control connecon: 9600 baud, 8 Data Bits, 1 Stop Bit, Parity = none
While the IPEXCB requires RS232 commands to be sent to it at 9600 baud through the control connecon, mulple
baud rates are available to communicate with the remote devices.
TX
G
RX
RXD
TXD
GND
IPEXCB
Third Party
Control System

IPEXCB Installaon Guide
9
Installaon Instrucons
Basic Installaon
1. Congure a managed 1Gb Ethernet network switch for IPLinx video operaon.
NOTE: An IPLinx network switch conguraon guide has been built to assist with conguring network switches
from a variety of manufacturers. The network switch conguraon guides are located on the IPLinx IPEXCB prod-
uct page on the Liberty website (www.libav.com) under the DOCUMENTATION tab.
2. Turn o power and disconnect the audio/video equipment by following the manufacturer’s instrucons.
3. Turn o power to the congured network switch.
4. Connect Category 5E or greater twisted pair cable with the TIA/EIA-568B crimp paern between the LAN1
port on the IPEXCB and the congured network switch.
NOTE: If the network switch cannot provide power or enough power to the IPEXCB, connect the included power
supply to the 12V DC power input of the control box. If the gigabit switch cannot provide enough power, disable
the PoE funcon of the connected LAN port on the switch.
5. Connect the IPLINX encoder(s) and decoder(s) to the network switch using Category 5E or greater twisted
pair cable with the TIA/EIA-568B crimp paern and per the instrucons for those device
6. Connect all sources and displays to the respecve IPLinx encoders and decoders.
7. Apply power to the congured network switch.
8. The IPEXCB will fully boot aer ve minutes.
9. Apply power to the aached audio/video devices.
To control the IPEXCB and IPLinx system by a third party control system, connect a Category cable between the
LAN2 port on the IPEXCB to an IP based third party control system network or use the RS232 connecon on the
IPEXCB to connect to a third party serial based control system according to the manufacturers system
instrucons. For proper serial connecvity to the IPEXCB please see RS232 Connecons on page 9.
For a comprehensive list of IP and serial system commands for the IPEXCB and IPLinx systems, please refer to the
IPLinx Programming Guide which is located under the DOCUMENTATION tab on the IPEXCB product page online
at www�libav�com
Pre-wrien control system drivers are also available online on the IPEXCB product page under the DRIVERS tab

IPEXCB Installaon Guide
10
IPEXCB Web Browser Usage
Logging into the web browser Graphical User Interface (GUI)
Connect a Windows PC to an open port on the congured A/V network switch with a Cat 5e patch cable and set
a stac IP address for the Windows PC that is within the IP range of the IPLinx IPEXCB Controller (169.254.1.xxx,
where xxx = any number between 2-254) and set the subnet mask to 255.255.0.0.
Please contact an IT administrator if the PC cannot be assigned a stac IP address in this range.
To change your computers IP address in Windows, navigate to Control Panel > Network and Internet and then
click on Network and Sharing Center. From there you will see the network that you are connected to. Typically the
network will be labeled as Unidened network.
Click on
A pop window will appear labeled Ethernet Status
Click on

IPEXCB Installaon Guide
11
Select Internet Protocol Version 4 (TCP/IPv4) from the item list and then click
Select the buon labeled
A pop window will appear labeled Ethernet Properes
A pop window will appear labeled Internet Protocol Version 4 (TCP/IPv4) Properes

IPEXCB Installaon Guide
12
Enter in an IP address for the computer in the same range as the IPEXCB in the IP Address eld, set the subnet mask
to 255.255.0.0 and click
In this example we used the IP address of 169.254.1.99 with a subnet mask set at 255.255.0.0
Note: If you change the IP address of the IPEXCB or the IPLinx devices that reside on the A/V network, be
sure to reset your computers IP address to the correct IP range of the IPEXCB in order to access the control
interface and the IPLinx system components.
Close the Ethernet Properes and Ethernet Status windows and then open a web browser on the computer and
enter the IP address of the IPEXCB into the address bar of the browser and hit the enter key on the keyboard. The
default IP address of the IPEXCB is 169.254.1.1

IPEXCB Installaon Guide
13
The login window for the web GUI will then appear, enter in the user name and password for the portal and click
LOGIN.
The default user name and password is admin
Aer logging into the web GUI, you will noce three tabs located at the top le of the page labeled;
SCENES, TX/RX SETTINGS and CONTROLLER SETTINGS
SCENES; allows you to route encoders to decoders, save up to three matrix scenes and test API commands.
TX/RX SETTINGS; allows you to change IP addresses of individual encoders and decoders on the IPLinx system as
well as test API commands
CONTROLLER SETTINGS; allows you to change the default IP addresses of the LAN1 (AV/PoE) and LAN2 (CTRL) ports
of the IPEXCB. You can also load system conguraons, change passwords for admin login, establish user name
and password for up to 5 users, upgrade soware version and test API commands.

IPEXCB Installaon Guide
14
Roung Video Signals
Using the web GUI, video signals can be routed from IPLinx encoders (TX) to decoders (RX) using the SCENES menu.
When the SCENES menu is highlighted, click on ALL DEVICES, this will show all of the acve IPLinx encoders and
decoders on the A/V network switch as well as four submenus labeled MATRIX, SCENE1, SCENE2, and SCENE3.
NOTE: By default encoders (TX) and decoders (RX) aliases are assigned in the system based on the following;
[MANUFACTURER PART NUMBER-MAC ADDRESS].
Example; IPEX2002-341B22802204
IPEX2002 is the manufacturers model number
341B22802204 is the assigned MAC address of that device
These assigned aliases can be changed by using IPLinx Congurator so they can be more easily idened.
See Renaming IPLinx Encoders and Decoders located on page 22

IPEXCB Installaon Guide
15
To route video from one TX to ALL RX’s, click on the desired ALL RXs cell located underneath the TX of choice. All
cells underneath the TX will turn solid green indicang that video is successfully being routed to all decoders.
The MATRIX submenu allows you to route video signals from encoders to decoders in real me using a simple
spread sheet layout.
Encoders (transmiers) are labeled as TX and located on the top row, decoders (receivers) are labeled as RX and
located to far le column. Simply use your mouse and click on the appropriate cell that links the desired TX source
to the desired RX locaon. Once your selecon is made and video is successfully routed to the desired decoder,
the cell will turn solid green. To remove that video source from the decoder, click the cell again and the cell will go
blank indicang no video is present at that decoder locaon.
NOTE: If video is not successfully routed to the decoder locaon or the decoder is oine, the cell selected will turn
solid RED.

IPEXCB Installaon Guide
16
SCENE1, SCENE2 and SCENE3 submenus allows you to build and save pre-set scenes that routes video from encoders
to decoders in a parcular order. These adjustments are not made in real me unless Auto apply box is checked.
To apply the scene to the system click APPLY
API telnet commands can be sent to the IPLinx system from the web GUI under the SCENES, TX/RX SETTINGS and
CONTROLLER SETTINGS menu tab. This is a useful tool to determine if telnet commands sent to the system invokes
the appropriate system response. An API command log is also available to monitor system responses which can be
turned ON or OFF. If you want a comprehensive list of telnet and serial commands please refer to the
IPLinx Programming Guide which can be downloaded from the IPEXCB product page under the DOCUMENTATION
tab online at www.libav.com
To test a command enter the command into the blank form under Telnet API Command and click Apply.
Tesng Telnet API Commands

IPEXCB Installaon Guide
17
Changing IPLinx Encoder and Decoder IP Addresses
The IPLinx IPEXCB control interface automacally assigns IP addresses to encoders and decoders in an IPLinx system
when they are discovered by the IPEXCB. You can change these auto assigned IP addresses to an address scheme
of your choice by accessing the TX/RX SETTINGS menu.
Note: The web browser GUI only oers manual changes to encoder and decoder IP addresses individually. If you
have several encoders and decoders on an A/V network that need to be changed, it would be advised to make a
batch change in IPLinx Congurator. Instrucons for batch changes, see Batch Commands on page 50.
To change the IP address of the selected device, check the appropriate IP MODE opon then enter in the IP address,
Subnet Mask and Default Gateway as desired, then click APPLY
BEST PRACTICE: It is a best pracce to physically label the IPLinx encoder or decoder with the newly changed IP
address so it can be located easily on an A/V network for future use and service. If you do not remember the newly
changed IP address of the IPLinx device and cannot nd it on the A/V network, you will have to perform a factory
reset on the device.
To select an encoder or decoder on the A/V network check the buon next to the appropriate device under DEVICE
SETTINGS. To refresh this list click RELOAD.

IPEXCB Installaon Guide
18
Changing IPEXCB IP Addresses
The IPLinx IPEXCB control interface is assigned with two default IP addresses; one for encoder (TX) / decoder (RX)
communicaon and one for telnet client / browser communicaon. To access the IP informaon for the IPEXCB
click on the CONTROLLER SETTINGS menu tab.
Conguraon les that have been built with IPLinx Congurator can be uploaded to the IPLinx system by using
Load Conguraon opon under CONTROLLER SETTINGS menu.
To load a conguraon le, select BROWSE to locate the le located on your computer or hard disk. Click APPLY to
inialize. Once a conguraon le has been loaded the previous conguraon le will be removed.
To change the IP address of either IP 1[TX and RX communicaon] and IP 2 [Telnet client and browser communicaon],
enter in the desired IP Address, Subnet Mask and Default Gateway then click APPLY. Aer pressing APPLY the
IPEXCB will reboot.
Best Pracce: It is a best pracce to reboot the network switch aer IP addresses have been changed on the
IPEXCB.
Loading IPLinx Congurator Files

IPEXCB Installaon Guide
19
User Management
The User Management secon of the CONTROLLER SETTINGS menu will allow you to change your administrave
password as well as establishing up to ve user logins that can only access the IPLinx video system matrix. This is
ideal for users that need to route video signals from encoders to decoders but don’t need administrave login to
change system parameters.
To change the administrave password, type in the desired password in the PASSWORD eld under Administrave
User and click SAVE.
To create a user login, type in desired user name and password in the User Name and Password elds under
Common User List and click SAVE.

IPEXCB Installaon Guide
20
Downloading IPLinx Congurator Soware
Making a PC Connecon
Running IPLinx Congurator Soware
The IPLinx Conguraon soware tool can be found on the IPEXCB product page under the SOFTWARE tab at
www.libav.com. Download the zip le and extract all les, then run the setup le (IPLinxCong_Setup.exe) on the
Windows PC that will be used to congure the IPEXCB and associated encoders and decoders.
Some IT administrators may prevent the IPLinx Cong soware from accessing the IP video network even though
the rewall permissions were approved. Please make sure that UDP ports 1234, 3333, 3334 and TCP ports 55000
through 56999 are open for proper access to the IP video network.
Connect a Windows PC to an open port on the A/V network switch with a Cat 5e patch cable.
Set a stac IP address for the Windows PC that is within the IP range of the IPEXCB (169.254.1.xxx) and set the
subnet mask to 255.255.0.0. See Logging into the web browser Graphical User Interface (GUI) on page 9.
Please contact an IT administrator if the PC cannot be assigned a stac IP address in this range.
Open the IPLinx Congurator soware. The link to the soware can be found in the Windows Start menu or on the
desktop if the opon was enabled during setup.
IPLinx Cong Soware Usage
If a rewall warning pops up, ck the check boxes for private and public networks.
Table of contents
Popular Adapter manuals by other brands

Atlantis Land
Atlantis Land A02-PL201-W54 quick start guide

Skross
Skross Classic USB manual

Helwett Packard
Helwett Packard HP-PB 100Base-T Installation and service

Airlink101
Airlink101 AWLL4030 user manual

SMC Networks
SMC Networks SMC EZ Connect N Pro Draft 11n Wireless CardBus Adapter... user guide

Lenovo
Lenovo N2225 user guide