ISYGLT IN-08T User manual

1
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
IN-08T
Article no. 80024080
IN Module with 8 digital inputs
Technical Data / Instruction Manual

2
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
1. Notes on documentation
These instructions are intended for qualified personnel who are
familiar with the assembly, installation and operation of the ISYGLT
system. It is essential that you read these operating instructions
through before commissioning and keep them accessible for further
use.
SEEBACHER cannot accept any liability for damage or malfunctions
resulting from failure to observe these instructions.
1.1. Retention of documents
These instructions and all other applicable documents are part
of the product. They must be handed over to the device operator.
The operator will store the documents so that they can be made
available if necessary.
1.2. Symbols used
Observe the following safety and other instructions in the manual:
Handling instruction
The hand indicates that you should carry out an act.
Danger!
Immediate danger to life!
Attention!
General notes, useful information and special features
Directory of Content
1. Notes on documentation
1.1. Retention of documents
1.2. Symbols used
2. Safety instructions
2.1. Intended usage
2.2. Predictable mishandling
2.3. Safe handling
2.4. Qualification of staff
2.5. Changes to the product
2.6. Use of spare parts and additional equipment
2.7. Liability notes
3. Warranty
4. Declaration of Conformity
5. Service address
6. Maintenance / Care / Disposal
7. Storage
8. Assembly
9. Product description
10. Technical Data
10.1. Pin assignment
11. Wiring diagram

3
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
The module is intended for universal installation in boxes or
lamps. Extreme environmental conditions impair the function of
the product.
• Protect module from shocks
• Use module indoors only
• Protect module from humidity
In addition to these safety instructions, you must also observe
the special safety instructions listed in the individual chapters for
the individual acts.
2.4. Qualification of staff
Assembly, commissioning, operation, maintenance, decom-
missioning and disposal may only be carried out by qualified
staff. Work on electrical parts may only be carried out by a trai-
ned electrician in accordance with the applicable regulations
and directives. Other activities in connection with the ISYGLT
module, such as assembly and installation of system compon-
ents with tested standard plug connections, as well as operation
and configuration of the ISYGLT module may only be carried out
by trained staff.
2.5. Changes to the product
Unauthorized modifications to the ISYGLT module which are not
described in this or the other applicable instructions can lead to
malfunctions and are prohibited for safety reasons.
2.6. Use of spare parts and additional equipment
The module may be damaged if unsuitable spare parts and
additional equipment are used. Only use original spare parts
and additional equipment from the manufacturer.
2.7. Liability notes
SEEBACHER accepts no liability or warranty whatsoever for
damage and consequential damage caused by non-compliance
with the technical regulations, instructions and recommendati-
ons. SEEBACHER shall not be liable for any costs or damage
incurred by the user or third parties as a result of the use of this
equipment, in particular improper use of the equipment, misuse
or malfunction of the connection, malfunction of the equipment
or connected devices.
SEEBACHER accepts no liability for printing errors.
2. Safety instructions
Observe the following general safety instructions when installing
and commissioning the device:
Assembly and installation of the ISYGLT module may only be car-
ried out by a qualified electrician. Other activities in connection with
the ISYGLT module, such as assembly and installation of system
components with tested standard plug connections, as well as ope-
ration and configuration of the ISYGLT module may only be carried
out by trained staff.
Observe the electrical installation regulations of the country in
which the device is installed and operated as well as its national
accident prevention regulations. In addition, observe internal com-
pany regulations (work, operating and safety regulations).
Before working on the ISYGLT module system, it must be
disconnected from the power supply and secured against
being switched on again. After completion of the assembly,
installation and maintenance work, an electrical check must
be carried out! Check all protective conductor connections
and the voltages at all connection plugs as well as at each
individual module slot.
2.1. Intended usage
The module is exclusively suitable for regulation (control) in con-
junction with ISYGLT system components. Any other use is not
intended. The limit values stated in the technical data must not
be exceeded under any circumstances. This applies in particular
to the permissible ambient temperature range and the permis-
sible IP protection type. For applications with a higher required
IP protection type, the ISYGLT module must be installed in a
housing or a cabinet with a higher IP protection type.
2.2. Predictable mishandling
The module must not be used in the following cases in particular:
•explosive area
When operating in explosive areas, sparking can lead to defla-
gration, fire or explosions.
2.3. Safe handling
This module corresponds to the state of the art and the recog-
nised safety regulations. Each device is tested for function and
safety before delivery.
Only operate this module in perfect condition in accordance with
the operating instructions, the applicable regulations and directi-
ves of the country in which the device is installed and operated,
and the applicable safety and accident prevention regulations.

4
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
6. Maintenance / Care / Disposal
The product is maintenance-free. It is sufficient from time to time to
remove any dust deposits. This may only be done in a power-free
state.
Disposal (European Union)
Do not dispose of product in household waste! Products with this
symbol
7. Storage
The product must be stored in a dry place, protected from dirt and
mechanical stress. After damp or dirty storage, the product may only
be operated after a condition check by an authorised electrician.
8. Assembly
(Only by certified electrician!)
Mount the product only when it is in a power-free state!
Switch off the power supply, check that there is no voltage, secure
against being switched on again!
The device may only be operated at voltages according to the tech-
nical data and loaded with the currents defined therein. Only use
suitable equipment (system power supplies).
Check that there are no loose parts in the product. If this is the case
and the presence of such parts is not explicitly described, do not
install or commission the product.
Only use suitable cables and fixing screws.
Assembly site
• The product can be installed in any position in a casing to be deter-
mined by the electrician (box, lamp, switch cabinet). Observe maxi-
mum ambient temperature!
• Keep sufcient distance from ammable materials.
Assembly steps
(Read completely before assembly!)
• Mount the device in a suitable casing.
• Make the electrical connections according to the wiring diagram.
• Congure the DIP switches according to your requirements.
• Only after a complete connection and a visual test by a qualied
electrician, the system may be put under voltage.
Seebacher GmbH
Marktstrasse 57
83646 Bad Tölz
GERMANY
Phone: +49 (0) 80 41 / 77 77 6
Fax: +49 (0) 80 41 / 77 77 2
www.seebacher.de
info@seebacher.de
5. Service address
4. Declaration of Conformity
The valid declaration of conformity for the module can be requested
from us free of charge by stating type and article no. as follows:
By phone: +49(0)8041/77776
By fax: +49(0)8041/77772
By mail: info@seebacher.de
3. Warranty
We provide warranty within the framework of the statutory provisi-
ons. These are limited to the intended use of the module and refer
to the repair or replacement of the ISYGLT module. Please send the
device with an attached error description to our company address
given below.
must be disposed of according to the EU directive WEEE 2012/19/
EU on waste electrical and electronic equipment at the local collec-
tion points for waste electrical and electronic equipment!

5
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
9. Product description
The IN-08T module provides 8 digital inputs in a very compact
design for connecting 24V motion sensors, conventional push but-
tons, switches or contacts. These inputs are transferred to the BUS
system and their functions can be freely defined by system program-
ming.
Inputs
• 8 optocoupler inputs
Function displays
• 1 red LED indicates the operating voltage
• 1 ashing yellow LED indicates the communication with the master via subnet
Connections
• 1 connection for the subnet (BUS A and B, RS-485)
• 1 connection for the operating voltage (Ub, 0V)
• 8 inputs
Design
• black plastic housing
Type designation IN-08T
Article no. 80024080
Operating voltage 24V DC
Current consumption 16mA
Inputs 12-27V DC, 5mA via optocoupler
Subnet (RS-485) max. 5.6V limited by Z-diodes
Dimensions LxWxH 30x45x15mm
Weight approx. 30g
Connection screw terminals 1.5mm² for Ub and BUS, inputs plug-in terminals max. 0.8mm
Operating temperature -10°C to +50°C
Storage temperature -25°C to +70°C
Humidity 0-85% r. h. non condensing
Protection class IP 30
CE mark yes
10. Technical data

6
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
Terminal Designation
E1 Input 1
E2 Input 2
E3 Input 3
E4 Input 4
E5 Input 5
E6 Input 6
E7 Input 7
E8 Input 8
0V 0V for motion sensors
+24V +24V for inputs or motion sensors
10.1. Pin assignment
Terminal Designation
≅Ub Operating voltage
0V Operating voltage
A Subnet (BUS A, RS-485)
B Subnet (BUS B, RS-485)
View
45.00mm
30.00mm
+24V +24V +24V +24V
0V 0V 0V 0V
E5 E6 E7 E8
E1 E2 E3 E4
Depth with terminals
16.5mm
15.00mm
Terminal assignment
ON DIP
12345 6 78
B
A
0V
~Ub

7
Seebacher GmbH www.seebacher.de Phone: +49 (0) 80 41 / 77 77 6
Marktstrasse 57, 83646 Bad Tölz info@seebacher.de Fax: +49 (0) 80 41 / 77 77 2
11. Wiring diagram
+24V
0V=
BUS-A
BUS-B
001
21
22
ISYGLT BW-02
Art. no.: 8008715*
Motion sensor
Ub
0V
OUT
ISYGLT BW-02
Art. no.: 8008715*
Motion sensor
Ub
0V
OUT
ISYGLT BW-02
Art. no.: 8008715*
Motion sensor
Ub
0V
OUT
1 2 3 4 5 6 7 8
BUS addressS
OFF
ON
ISYGLT IN-08T
Art. no.: 80024080
E1
E2
E3
E4
Ub
0V
BUS A
BUS B
+24V
0V
0V
+24V
+24V
0V
0V
+24V
+24V
0V
E5
+24V
0V
E6
+24V
0V
E7
+24V
0V
E8
Misprints and technical changes reserved.
This manual suits for next models
1
Table of contents
Other ISYGLT I/O System manuals
Popular I/O System manuals by other brands

ACT
ACT ACTPRO IOM Installation and configuration instructions

National Instruments
National Instruments NI PXI-7851 Getting started

Stahl
Stahl IS1 manual

ICP DAS USA
ICP DAS USA tM-P8 quick start guide

M-system
M-system R7M-TS4-R instruction manual

National Instruments
National Instruments USB-6221 OEM user guide

M-system
M-system R7K4F Series instruction manual

M-system
M-system R7G4HML-6-SVF8N instruction manual

Rockwell Automation
Rockwell Automation Allen-Bradley SLC 500 BASIC Reference manual

Mobotix
Mobotix MX-232-IO-Box Quick install

S+S Regeltechnik
S+S Regeltechnik THERMASGARD 9112 Operating Instructions, Mounting & Installation

Seneca
Seneca ZC-24DI installation manual