ivc PTZ-3300-01 User manual

NetworkCam
PTZ-3300-01
User's Manual

- 1 -
Package Contents
Network Camera
Power adapter
A/V Cable
Remote Controller
Camera stand

- 1 -
Installation
Hardware Installation
Please verify that your product package contains
al
l the accessories listed in the foregoing
Package Contents. epending on the user’s
application, an Ethernet cable may be needed.
The Ethernet cable should meet
the specs of UTP
Category 5 and not exceed 100 meters in length.
Connect the power adapter
jack to the
Network Camera before plugging in to the power
socket. This will reduce the risk of accidental
electric shock.
Upon powering up, the device runs through a self-test procedure and the front LE s will blink
between green and red for a few times. If self-test passes, the LE s will shut off and the Network
Camera will be on stand-by and ready for software installation. If self-test fails the red LE will
blink several times. Refer to Appendix A for troubleshooting.
To install in Ethernet
Make sure the Ethernet is firmly connected to a switch hub. After attaching the Ethernet cable
plug in the power adapter. If the LE turns out to be steady green after self-test, go to next
paragraph “Software Installation”.
1 I+ INPUT (Max. 50mA, 12V C)
2 I- INPUT (Initial state of I is low)
3 SW_COMMON OUTPUT (open from SW_OPEN at initial state)
(close with SW_OPEN when set O to ON)
4 SW_NOPEN OUTPUT (Max. 1A, 24V C or 0.5A, 125VAC)

- 2 -
Initial Access to the Network Camera
Installing Plug-in
For the initial access to the Network Camera in Windows, the web browser may prompt for
permission to install a new plug-in for the Network Camera after a period of time of downloading.
Permission request depends on the Internet security settings of the user’s PC or notebook. If the
highest security level is set, the computer may prohibit any installation and execution attempt.
This plug-in has been registered for certificate and is used to display the video in the browser.
Users may click on to proceed. If the web browser does not allow the user to continue
to install, check the Internet security option and lower the security levels or contact your IT or
networking supervisor for help.
Add Password to Prevent Unauthorized Access
The default Administrator’s password is blank and the Network Camera initially will not ask for any
password. The Administrator should immediately implement a new password as a matter of prudent
security practice. Once the Administrator’s password is saved, the Network Camera will ask for the user’s
name and password before each access. The Administrator can set up a maximum of twenty (20) user
accounts. Each user can access the Network Camera except to perform system configuration. Some critical
functions are exclusive for the Administrator, such as system configuration, user administration, and
software upgrades. The user name for the Administrator is permanently assigned as “root”. Once the
password is changed, the browser will display an authentication window to ask for the new password. Once
the password is set, there is no provision to recover the Administrator s password. The only
option is to restore to the original factory default settings.

- 3 -
Appendix
A. Troubleshooting
Status LE
After powering up, the Network Camera performs a self-diagnostic to detect any hardware
defects. The following table lists the LE patterns in general. In case of any fatal error, the LE
will blink in a pattern other than those below.
Condition LE color
uring self-diagnostic after power on Blink in interchanged green and red
Ethernet signal is lost Red LE is off till Ethernet is detected
Before network is setup Steady green till IP address is confirmed
After network is setup Blink green every second
Any hardware failure Other patterns
Reset and Restore
At the left side of the camera there is a button
hidden in the pinhole as shown in the picture. It is
used to reset the system or restore the factory
default settings. Sometimes resetting the system
sets the system back to normal state. If the system
problems remain after reset, restore the factory
settings and install again.
RESET: Poke the wrench to click on the button.
RESTORE: 1. Poke the wrench to press on the
button continuously. 2. Wait for self-diagnostic.
uring the diagnostic period, the red & green lights
will flick for several times. 3. Withdraw the wrench
when all the lights are off.
Restoring the factory defaults will
erase any previous settings. Reset or
restore the system after power on.

- 4 -
B. Cleaning the Lens
The Network Camera with Pan/Tilt/Zoom is a network camera with high quality lens. When it is
necessary to clean the lens, please follow these instructions:
Prepare cotton swabs and alcohol.
Moisten the cotton swab with alcohol.
Slightly clean the lens.
1. If the lens is still dirty, repeat 2~3 steps until it is cleaned. Change a clean cotton swab if
the old one is dirty or contains dirt that might scrape the lens. Never touch the lens hard or
roughly.
C. Technical Specifications
- Networking
Protocol
TCP/IP, HTTP, SMTP, FTP, Telnet, NTP, NS UPnP,
NS and HCP
Physical
10BaseT Ethernet or 100BaseT Fast Ethernet
- Video
Algorithm supported
MPEG4 SP
MJPEG
Resolution
Up to 30/25 frames at 176x120 or 176x144
Up to 30/25 frames at 352x240 or 352x288
Up to 15/12 frames at 704x480 or 704x576
- Camera specification
1/4 inch color CC sensor
Typical: 1.5 Lux / F1.8
Low lux mode: 0.05 Lux/F1.8
AGC, AWB
Electronic shutter: 1/60(1/50) to 1/120,000 sec
Pixel Numbers: NTSC - 542(H)x496(V) or PAL -
542(H)x586(V)
- Lens
Focal length 4.2~42mm
Aperture F1.8~2.9
10X optical zoom
10X digital zoom
- General I/O
1 sensor input(max. 12V C 50mA)
1 relay output(max. 24V C 1A, 125VAC 0.5A)
- LED indicator
ual color system status indicator
- Weight
NET. 450g
- Dimension
104.5mm(L) * 104.5mm(W) * 127mm(H)
- Power
Consumption: MAX 12 W
Universal switching power-supply included
Adapter input: 100-240VAC, 50/60Hz, 0.4A
Adapter output: 12V C, 1.5A
- Operating Environment
Temperature: 0-40°C/32-104°F
Humidity: 85%RH
-EMI & Safety
CE, FCC
Table of contents