JA-110N Bus power output module PG
The JA-110N is a component of the JABLOTRON 100 system.
It provides an output power relay switch. It can be used for
switching on/off the lights, ventilators, etc. The relay can be
controlled with a programmable control panel (PG) output or
according to the status of a section (armed = relay on) or when
there is an alarm in a chosen section (alarm = relay on). The device
should be installed by a trained technician with a valid certificate
issued by an authorized distributor.
Installation
The module shall be installed into the JA-190PL mounting box.
figure: 1 – digital bus terminals; 2 – red relay switching indicator;
3 – configuration switch; 4 – output relay; 5 – relay terminals
1. Use the switch (3) to set the required number of the PG output or
the number of the section to which the relay should react (see
tables).
2. Connect bus wires to the terminals (1).
When connecting the module to the
system digital bus, always switch the
power off.
If the module is installed outside the
protected area, the JA-110T bus insulator
should be used for the external section of
the wiring.
Electrical devices can only be
connected by an authorized
technician.
3. Switch on the system and test its functioning.
4. Check the supply voltage at the bus terminals (red, black) when
the relay is activated. The voltage must be at least 9V.
5. Connect the controlled device to the relay output terminals (5).
Notes:
- The module does not occupy any position in the control panel
(it is not enrolled into the system).
- If you connect multiple modules with identical settings to the bus,
the relays will have the same function.
- The number of modules is only limited by the power consumption
from the digital bus.
- The setting of individual programmable outputs is done in the PG
outputs window in the F-Link program. A detailed description of
the setting is available in the control panel installation manual.
- When the output is set according to the SECTION SET table the
relay is on if the section is fully armed.
- When the output is set according to the SECTION ALARM table
the relay is on if there is external or internal warning (EW or IW).
Table 1: The relay reacts to the PG output state
Table 2: The relay reacts to arming
the choosen section
Table 2: The relay reacts to an
alarm in the choosen section
Technical specifications
Power from control panel digital bus 12 V (9…15 V)
Current consumption in standby mode (relay off / on) 5 mA / 45 mA
Current consumption for cable choice 45 mA
Relay contact rating
Maximum voltage 250 V AC / DC
ReVLVWLYHORDGFRVij  max. 16 A / 250 V AC
IQGXFWLYHFDSDFLWLYHORDGFRVij  max. 8 A / 250 V AC
Minimum acceptable relay output through-wattage(DC) 0.5 W
Protection Class II
Dimensions 78 x 40 x 20 mm
Classification Grade II
according to EN 50131-1, EN 50131-3
Operational environment according to EN 50131-1 II. Indoor general
Operating temperature range -10 °C to 40 °C
Also complies with EN 50130-4, EN 55022, EN 60950-1
JABLOTRON ALARMS a.s. hereby declares that the JA-110N
module is in compliance with the essential requirements and other
relevant provisions of Directive 2004/108/(EC and 2006/95/EC.
The original of the conformity assessment can be found at
www.jablotron.com - Technical Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use. For more detailed information
visit www.jablotron.com.
JA-110N Bus power output module PG 1 / 1 MLY51306

Other jablotron I/O System manuals

jablotron JA-68 User manual

jablotron

jablotron JA-68 User manual

jablotron JB-110N User manual

jablotron

jablotron JB-110N User manual

jablotron JA-110N-DIN User manual

jablotron

jablotron JA-110N-DIN User manual

Popular I/O System manuals by other brands

W&T 57732 manual

W&T

W&T 57732 manual

Reliance electric 57C409 instruction manual

Reliance electric

Reliance electric 57C409 instruction manual

ICP DAS USA PIO-DA4 user manual

ICP DAS USA

ICP DAS USA PIO-DA4 user manual

National Instruments PXIe-4357 user manual

National Instruments

National Instruments PXIe-4357 user manual

National Instruments FieldPoint FP-AI-100 operating instructions

National Instruments

National Instruments FieldPoint FP-AI-100 operating instructions

NI FieldPoint FP-AIO-600 operating instructions

NI

NI FieldPoint FP-AIO-600 operating instructions

Siemens Simatic ET200pro manual

Siemens

Siemens Simatic ET200pro manual

Elvaco CMeX40 manual

Elvaco

Elvaco CMeX40 manual

Spectrum Controls Micro850 user manual

Spectrum Controls

Spectrum Controls Micro850 user manual

Solid State Logic SSL SDI user guide

Solid State Logic

Solid State Logic SSL SDI user guide

S&T Kontron 3.5"-eIO-GPA user guide

S&T

S&T Kontron 3.5"-eIO-GPA user guide

MG Mini-M M2VV instruction manual

MG

MG Mini-M M2VV instruction manual

Carrier UC Open XP Installation and start-up instructions

Carrier

Carrier UC Open XP Installation and start-up instructions

Panasonic AV-HS04M1 operating instructions

Panasonic

Panasonic AV-HS04M1 operating instructions

Balluff PROFINET BNI PNT-508-055-P067 user guide

Balluff

Balluff PROFINET BNI PNT-508-055-P067 user guide

G3 RioExpress quick start guide

G3

G3 RioExpress quick start guide

Seneca Z-DAQ-PID user manual

Seneca

Seneca Z-DAQ-PID user manual

Sony BKP-7311 installation manual

Sony

Sony BKP-7311 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.