JB Platinum Series Instructions for use

1
,
,
In order to make the best use of your
investment, familiarize yourself with the
new features and operating instructions
before starting pump. With just routine
care your
Platinum
will give you years of
reliable service by following proper
maintenance guidelines.
Platinum
pumps
are designed for deep vacuum work in
refrigeration systems only.
IMPORTANT:Use oil specifically refined
for deep vacuum pumps. Using oil not
refined for deep vacuum pumps and/or
operating with contaminated oil will void
warranty.
IMPORTANT
This unit has been drained for shipment.
DO NOT ATTEMPT TO OPERATE
WITHOUT ADDING OIL.
TM
2-Stage, Direct Drive
OPERATING INSTRUCTIONS ,
& PARTS MANUAL
Platinum Series Vacuum Pumps
DV-42N, DV-85N,
DV-142N, DV-200N & DV-285N
MOTOR
1/2 HP, 50HZ, 230 Volt; Capacitor start;
Automatic thermal overload protected.
INTAKE
DV-42N 1/4 Male Flare
DV-85N 1/4 x 3/8 Male Flare
DV-142N,
DV-200N & DV-2853/8 x 1/4 x 3/8 Male Flare
FREE AIR DISPLACEMENT
CFM Liters Per Minute
DV-42N 1.5 42
DV-85N 385
DV-142N 5 142
DV-200N 7 200
DV-285N 10 285
-250 Series
MOTOR
1/2 HP, 50 HZ, 230 Volt; Capacitor start;
protected.
INTAKE PORT
See Above
FREE AIR DISPLACEMENT
50 HZ
Liters Per
CFM Minute
DV-42N-250 1.25 35
DV-85N-250 2.5 71
DV-142N-250 4.2 119
DV-200N-250 5.8 167
DV-285N-250 8.3 237
Specifications
¡
Automatic thermal overload
Dual voltage
motors avail-
able upon
request
EXHAUST
OIL DRAIN VALVE
Close Drain Finger
Tight.
OIL FILL PLUG
Do Not Wrench
Down Or Use
Sealant On
Threads
GAS BALLAST
VALVE
INTAKE
ISOLATION
(BLANK-OFF)
VALVE
,
Each
Platinum
pump has been factory tested to guarantee 25 micron or
better and listed CFM performance. The serial number has been recorded.
Complete and mail the Warranty Registration Card within10 days of
purchase to validate your warranty. You will be notified of any technical
updates.
25,400 Microns = 1"

2
After Evacuation, Oil Contains Rust
Forming Water and Corrosive Acids.
Drain Immediately While Pump Is Warm.
CLOSED
POSITION
OPEN
POSITION
PAUSE
POSITION
CAPACITY
DV-42N
30 oz. (865 cc)
DV-85N
27 oz. (785 cc)
DV-142N
23 oz. (660 cc)
DV-200N
23 oz. (660 cc)
DV-285N
24 oz. (705 cc)
Slowly add oil until oil level rises to the
top of OIL LEVEL line. Replace oil fill
plug.
If oil is too low, you will hear the exhaust
baffle chatter. If the oil level is too high,
OIL
OPERATION
PUMP MOTOR
Pump and oil must be above 30 oF. Line
voltage must be equal to motor
nameplate p10%. Normal operating
temperature is approximately 160oF,
which is hot to the touch. Line voltage and
ambient conditions will affect this
somewhat. Motor has automatic resetting
thermal overload protection.
Platinum
is
designed for continuous duty and will run
for extended periods without overheating.
Quarter-turn on/off. No additional valve
needed to isolate system.
When checking pressure rise, slowly turn
handle counter-clockwise. Pause at 45 o.
Valve completely closed at 90 o.
START-UP
Open one intake port and isolation valve,
close gas ballast valve and start pump.
Make vacuum connections.
Crack gas ballast valve for the first part of
the evacuation procedure. After pump
quiets down from initial volume of air,
close valve and continue evacuating.
Failure to close valve will result in poor
pump performance.
SHUT-DOWN
Close isolation valve and crack gas
ballast valve. Continue running pump for
2-3 seconds. With gas ballast valve still
cracked, stop pump and then close valve.
Remove hose connections and cap
intakes.
IMPORTANT
DO NOT START PUMP BEFORE ADDING OIL
The following procedures will prevent oil from being drawn
into cartridge and creating hard start-up.
CHANGING OIL
To reach deep vacuum, Platinum pumps need
clean, moisture-free oil throughout evacuation.
Care should be taken to avoid contact on skin and clothing when changing oil.
Used oil should be disposed of in a leakproof corrosive-resistant container.
Pump oil should be changed after each
use. If system is heavily contaminated, oil
may have to be changed several times
during evacuation.
ISOLATION
(BLANK-OFF) VALVE
1. After every evacuation while pump is warm and oil is thin, place
pump on level surface and open oil drain. Oil can be forced from
the pump by opening one intake and partially blocking the
exhaust with a cloth while the pump is running. Do not operate
the pump for more than 20 seconds using this method.
2. Close drain. Remove oil fill cap and fill to top of OIL LEVEL line
with
Black Gold
Pump Oil. Replace oil fill cap.
FLUSHING
If the oil is badly contaminated, flushing may be necessary. Slowly
Black Gold
oil into the intake connection while pump is running.
Repeat as required until contamination is removed from oil resevoir, pump
rotors, vanes and housing.
Dispose of all oil used in flushing of pump.
Being just a teaspoon
low affects the ultimate
vacuum.
excess oil will be blown out the exhaust.
DIGITAL
VACUUM
GAUGES
DV-22N
Battery
DV-20
Battery/Electric
LDigital Display With Solid State Circuitry
L+32 oF to +120 o
F (0
oC to 48.9 oC)
Ambient Temperature
LNIST Traceable
LSolid State Design – No Adjustment
Necessary For Temperature
LAutomatic Power Off Battery Saver
LSaves Last Vacuum
Readout After Shutdown
LLow Battery Indicator
Both Gauges Feature
LReads Vacuum In 7
International Units:
Microns, PSIA, InHg,
MBars, Pascals, Torr, MTorr
pour 1/3-1/2 cup

3
Ref. Part
No. No. Description Ref. Part
No. No. Description
15 PR-208 Flexible Coupler
16 PR-42 Motor Foot & Screw
PR-31 6' Line Cord, 115V (Emerson before 1201)
17 PR-58 6' Line Cord w/M & Fe Ends, 115V (Marathon)
PR-35 Rocker Switch, 115V (Marathon)
18 PR-54 Rocker Switch, 115V (Emerson before 1201)
PR-206 1/2 HP, 115V, 60HZ Motor w/Line Cord and
Switch (Marathon)
19 PR-207 1/2 HP, 115/230V, 50/60 HZ Motor w/Line Cord
and Switch (Marathon)
20 PR-5 Intake Tee with Caps
21 PR-7 Gas Ballast Valve w/O-Ring
22 P90009 O-Ring, Gas Ballast Valve
23 PR-40 Splash Guard and Screw
24 PR-205 Cushioned Handle w/Lift Loop
25 PR-22 Oil Fill Plug w/O-Ring
Not Shown
PR-18 Cartridge Valve Repair Kit (Excluding 285N)
PR-52 DV-285N Cartridge Valve Repair Kit
PR-45 Pump Repair Kit: PR-1, PR-2, PR-4(2),
PR-42, PR-208
1 PR-1 Sight Glass
2 PR-2 Drain Valve
PR-300 DV-42N through DV-200N Cover Assy.
3 w/Sight Glass and Drain Valve
PR-301 DV-285N Cover Assy. w/Sight Glass and Drain Valve
PR-305 DV-42N Cartridge w/O-Rings and Cover Seal
PR-302 DV-85N Cartridge w/O–Rings and Cover Seal
4 PR-303 DV-142N Cartridge w/O–Rings and Cover Seal
PR-304 DV-200N Cartridge w/O–Rings and Cover Seal
PR-314 DV-285N Cartridge w/O–Rings and Cover Seal
5 PR-311 Cover Seal
6 PR-211 Trap O-Ring, Gas Ballast
7 PR-3 Shaft Seal
8 PR-315 Trap O-Ring, Intake
9 PR-4 Rubber Foot & Screw Assy. (1 per pkg.)
10 PR-24 Intake Cross with Caps
11 NFT5-4 1/4" O-Ring Cap
12 NFT5-6 3/8" O-Ring Cap
13 PR-32 1/4" Intake with Cap
14 PR-209 Plastic Isolation Valve Handle & Screw
1
2
3
5
6
7
8
17
22
23
16
15
9
14
21
24
18
10
11
13
25
12
4
20
19 12
11
11
REPAIR PARTS
Please provide following information:
–Model number
–Four digit serial number
–Part description and number as shown in parts list

4
Should you need further assistance,
write our Home Office or contact your
nearest J/B Service Center.
MAIN WAREHOUSE
JB INDUSTRIES, INC.
P.O. Box 1180–Dept. 85
Aurora, Illinois 60507-1180 USA
E-mail: [email protected]
Visit our web site at: www.jbind.com
CANADA
ALLTEMP PRODUCTS CO., LTD.
827 Brock Road South
Pickering, Ont., Canada L1W 3J2
Phone: (905) 831-3311
Fax: (905) 831-1864
Form 10185-308
Printed in U.S.A.
¢2006 JB Industries Inc.
Pump won’t start.
Pump won’t pull deep vacuum.
1. Plug power cord in securely.
2. Turn motor switch to ON position.
3. Warm up pump to 30°F & turn motor
switch on.
4. Line voltage must be within 10% of
115 volt.
1. Change oil.
2. Add oil.
3. Locate & repair leaks.
4. Clean or replace O-ring.
Corrective Action
Symptom Possible Cause(s)
1. Power cord not plugged in securely.
2. Motor switch not on.
3. Pump temp. below 30°F.
4. Inconsistent line voltage.
1. Contaminated oil.
2. Oil level too low.
3. Air leak in system being evacuated.
4. Pump inlet fittings missing or not
tightened.
5. Coupler slipping
WARRANTY
Platinum
pumps are warranted against defects in materials and workmanship for 2 years. All JB products are
guaranteed when used in accordance with our directions and recommendations, and we limit this warranty to the repair,
replacement, or credit at invoice price (our option) of products which in our opinion are defective due to defects in
workmanship and/or materials. In no case will we allow charges for labor, expense or consequential damage. Repairs
performed on items out of warranty will be invoiced on a nominal basis. Contact you wholesaler for details.
TROUBLESHOOTING CHART
Thermal overload may be open.
Pump shuts down and will not start.
Damaged oil seal.
Oil drips from point where shaft
enters the pump housing.
Replace.
factory for repair.
1. Remove 1/4" cap.
2. Turn pump on.
Pump cycles on and off from a
completely cold start and then runs
smoothly.
Oil backed up into cartridge and was
being cleared out. Pump has not been
shutdown properly.
5. Tighten coupler setscrews to flats of
cartridge and motor.
PUMP MOTOR
Pump and oil must be above 30 °F. Line voltage must be equal to motor nameplate ±10%. Normal operating temperature is
approximately 160°F, which is hot to the touch. Line voltage and ambient conditions will affect this somewhat. Motor has automatic
resetting thermal overload protection.
Platinum
is designed for continuous duty and will run for extended periods without overheating.
Disconnect pump from system.Wait about
15 minutes for motor to cool and turn it on
again.If it cycles off again, return pump to
TM
TM
Toll Free Technical Service
JB INDUSTRIES INC.
Aurora, Illinois 60505 USA TM
Number 1-800-323-0811
This manual suits for next models
5
Table of contents
Other JB Water Pump manuals
Popular Water Pump manuals by other brands

Finish Thompson
Finish Thompson DB11 series Assembly, installation and operation manual

Pfeiffer Vacuum
Pfeiffer Vacuum OKTA 1000 operating instructions

Idex
Idex Warren Rupp Sandpiper Drillers Series Service & operating manual

Ametek
Ametek T-620 user manual

BLACKMER
BLACKMER CRL2 instructions

Pentair
Pentair FOLEO 5800 XTR Installer manual

JD HEALTHCARE
JD HEALTHCARE LEVABO TURN ALL user manual

Wilo
Wilo VeroLine-IPH-O Installation and operating instructions

EINHELL
EINHELL GC-GP 1045 Original operating instructions

Espa
Espa VIGICOR 150M instruction manual

Agora-Tec
Agora-Tec AT 001 008 001 operating instructions

Grundfos
Grundfos PS.W.04-20 Installation and operating instructions