JOOBY Avenue Series User manual

JOOBY™
AVENUE luminaires series
USER MANUAL

2
This user manual contains information about the JOOBY AVENUE luminaires (hereinafter
referred to as "luminaires"), and sets the rules of exploitation and storage of the device.
1GENERAL INFORMATION
1.1 Luminaires are compliant to the requirements of Directive LVD 2014/35/EU,
Directive EMC 2014/30/EU, EN 60598-1, EN 60598-2-3, EN 60598-2-1, EN 60598-2-5.
1.2 Denotation of possible luminaires options:
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Housing type:
С –console;
S –suspended.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Quantity of light modules:
from 1 to 5.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Power consumption of each light module:
20 –20 W;
30 –30 W;
40 –40 W;
60 –60 W;
80 –80 W.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Optical system type:
S1 –asymmetrical glass lens 145°x65°;
S2 –asymmetrical glass lens 170°x120°;
S3 –asymmetrical glass lens 160°x80°;
S4 –asymmetrical glass lens 150°x70°;
S6/T1 –28 LEDs asymmetrical lens arrays, type I
S6/T2 –28 LEDs asymmetrical lens arrays, type II;
S6/T3 –28 LEDs asymmetrical lens arrays, type III;
S6/T5s –28 LEDs symmetrical lens arrays, type V;
S6/Sc –28 LEDs symmetrical lens arrays, type II/III (long);
F1/45 –symmetrical glass lens 45°x45°;
F1/60 –symmetrical glass lens 60°x60°;
F1/90 –symmetrical glass lens 90°x90°;
F1/120 –symmetrical glass lens 120°x120°;
F6/30 –28 LEDs symmetrical lens arrays 30°x30°;
F6/65 –28 LEDs symmetrical lens arrays 65°x65°;
F6/90 –28 LEDs symmetrical lens arrays 90°x90°;
F7/18 –36 LEDs symmetrical lens arrays 18°x18°;
F7/22 –36 LEDs symmetrical lens arrays 22°x22°;
F7/30 –36 LEDs symmetrical lens arrays 30°x30°;
F7/45 –36 LEDs symmetrical lens arrays 45°x45°;
F7/1840 –36 LEDs symmetrical lens arrays 18°x40°;
F7/115d –36 LEDs mattsymmetrical lens arrays 115°x115°;
F7/125 - 36 LEDs symmetrical lens arrays 125°x125°.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Correlated colour temperature:
3К – 3000 К;
4К – 4000 К;
5К – 5000 К;
5.7К – 5700 К;
6.5К – 6500 К.

3
Avenue S2x80-S1-5K7H-Ci-SPС- Т1
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Colour rendering index:
7 –70 -79;
8 –80 - 89;
9 –≥90.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Efficacy category:
T –≥91 lm/W (tiny);
I –≥101 lm/W (initial);
S –≥111 lm/W (small);
M –≥121 lm/W (medium);
L –≥131 lm/W (large);
Н –≥141 lm/W (high);
E –≥151 lm/W (extra);
U –≥161 lm/W (ultra).
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
LED manufacturer:*
Ci –Citizen Electronics Co., Ltd;
Os –Osram AG;
Se –Seoul Semiconductor Co., Ltd;
Cr –Cree Inc.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Surge protection module:*
SP –10 kА, uncontrollable;
SPC –10 kА, controllable;
SP2 –20 kА, uncontrollable;
SP2C –20 kА, controllable.
Avenue S2x80-S1-5K7H-Ci-SPС-Т1
Mount type:**
T1 –for hanging rope, 3d;
F1 –narrow floodlight type, 2d;
F2 –narrow floodlight type, 3d;
F3 –wide floodlight type;
Fw –wide floodlight type, separate;
R –eye nut;
Rх2 – eye nut, 2pcs.
* Symbols are present in luminaire designations only when corresponding options are included.
** Used only with S-type housing (suspended).
The manufacturer reserves the right to make changes in design and designation of luminaire
options, which do not worsen products technical characteristics.
1.3 Product description, serial number, manufacturing date —see chapter 11.
1.4 Manufacturer:
“TELECOMMUNICATION TECHNOLOGIES Ltd”
Office address:
65026, Ukraine, Odessa, 1 Mytna Ploscha
Phone: +380 48 759-09-09

4
2ABOUT PRODUCT
2.1 The luminaire is intended for illumination of streets, roads, highways, tunnels, bridges,
parks, residential areas, industrial locations, public spaces, administrative buildings, parking lots, etc.
The luminaire can be used for general internal illumination of production halls, warehouses,
stores, auxiliary rooms, etc.
The light source is an irreplaceable light-emitting-diode module.
2.2 The luminaire is intended for exploitation in the AC mains with 230 V rated voltage and
50 Hz frequency.
2.3 Luminaire remains its efficiency with ambient temperature from minus 40 to 50 °С.
2.4 Depending on the embodiment, in accordance with chapter 1.2, the luminaire has the built-
in surge protection module and is capable of working at the following conditions:
–SP and SPС options –according to EN 61000-4-5 (4 kV/2 kА, 6 kV/3 kА, 10 kV/5 kА) and
IEEE C62.41.2 category С Low (6 kV/3 kА);
–SP2 and SP2С options –according to EN 61000-4-5 (4 kV/2 kA, 6 kV/3 kА, 10 kV/5 kА)
and IEEE C62.41.2 category С High (20 kV/10 kА).
2.5 The luminaire is suitable for mount on surface of materials with normal flammability rank.
2.6 The mounting method, depending on luminaire embodiment and mount type, is encoded
according to table 2.1.
Table 2.1
Luminaire option
Mounting method
Avenue СX-…
on console (tube)
on vertical pole
Avenue SX-…-T1
on bearing cable
Avenue SX-…-F1
on a wall or ceiling
Avenue SX-…-F2
Avenue SX-…-F3
Avenue SX-…-Fw
Avenue SX-…-R
on suspended rope
Avenue SX-…-Rx2

5
3TECHNICAL SPECIFICATION
3.1 Basic characteristics:
–Limit voltage value, V
–min 120, max 280
–AC frequency, Hz
–50
–Power factor
–≥0,95
–Colour rendering index (CRI)
–≥70
–Ingress protection according to EN 60529
–IP66
–Protection class against electric shock in accordance
to EN 60598-1
–І
–Lifetime, h
–≥100000
–Lumen maintenance
–L70
–Failure fraction corresponding to the lifetime
–F50
3.2 Rated power of the luminaire Р, W is calculated by the formula:
Р=Рмn, (1)
where Рм–rated power of light module, W;
n –quantity of light modules.
The consumed power of the luminaire must not exceed 10 % of the rated values.
3.3 Rated luminous flux of luminaire of , lm is calculated by the formula:
Ф=Фмn, (2)
where Фм–rated luminous flux of the light module, lm;
n –quantity of light modules.
The actual luminous flux of the luminaire must be not less than 90 % from the rated value.
3.4 Rated power and luminous flux of the light modules are encoded according to table 3.1.
Table 3.1
Group of
luminous
efficacy
Nominal
luminous
efficacy of
the module,
lm/W
Rated power of a single module, W
Class of
energy
efficacy
20
30
40
60
80
Rated luminous flux of a single module, lm
T
100
2000
3000
4000
6000
8000
A+
I
110
2200
3300
4400
6600
8800
A+
S
120
2400
3600
4800
7200
9600
A+
M
130
2600
3900
5200
7800
10400
A++
L
140
2800
4200
5600
8400
11200
A++
H
150
3000
4500
6000
9000
12000
A++
E
160
3200
4800
6400
9600
12800
A++
U
170
3400
5100
6800
10200
13600
A++
3.5 The luminaire’s energy efficiency class is determined by the class of the light module in
accordance with table 3.1.
3.6 The light intensity distribution diagram and average beam angle of the luminaire depending
on the optical system type are encoded according to table 3.2.

6
Table 3.2
Optical system type
Intensity distribution
diagram
Average beam angle
S1
figure 3.1
145°/65°
S2
figure 3.2
170°/120°
S3
figure 3.3
160°/80°
S4
figure 3.4
150°/70°
S6/T1
figure 3.5
145°/80°
S6/T2
figure 3.6
160°/50°
S6/T3
figure 3.7
150°/60°
S6/T5s
figure 3.8
140°
S6/Sc
figure 3.9
160°/65°
F1/45
figure 3.10
45°
F1/60
figure 3.11
60°
F1/90
figure 3.12
90°
F1/120
figure 3.13
120°
F6/30
figure 3.14
30°
F6/65
figure 3.15
65°
F6/90
figure 3.16
90°
F7/18
figure 3.17
18°
F7/22
figure 3.18
22°
F7/30
figure 3.19
30°
F7/45
figure 3.20
45°
F7/1840
figure 3.21
18°/40°
F7/115d
figure 3.22
115°
F7/125
figure 3.23
125°
Figure 3.1 Figure 3.2 Figure 3.3
Figure 3.4 Figure 3.5 Figure 3.6
Figure 3.7 Figure 3.8 Figure 3.9

7
Figure 3.10 Figure 3.11 Figure 3.12
Figure 3.13 Figure 3.14 Figure 3.15
Figure 3.16 Figure 3.17 Figure 3.18
Figure 3.19 Figure 3.20 Figure 3.21
Figure 3.22 Figure 3.23

8
3.7 The correlated colour temperature in depending on luminaire options is encoded according to
table 3.3.
Table 3.3
Luminaire option
Correlated colour temperature, K
Rated value
Tolerance intervals
Avenue …-3КХХ-…
3000
2850 - 3250
Avenue …-4КХХ-…
4000
3750 - 4250
Avenue …-5КХХ-…
5000
4750 - 5350
Avenue …-5.7КХХ-…
5700
5350 - 6000
Avenue …-6.5КХХ-…
6500
6000 - 7000
3.8 Luminaires dimensions and mass, depending on housing type, mount type and light
modules quantity, are encoded according to table 3.4.
Table 3.4
Housing type
and quantity
of light
modules
Mount
type
Dimensions, mm, not more
than
Mass, kg, not more
than
Projected
area, m2, not
more than
Optical system type
Single glass lens
Plastic lens
array
Single glass
lens
Plastic lens
array
Avenue С1
390х250х130
390х250х110
5,5
5,3
0,07
Avenue С2
525х250х130
525х250х110
8,4
8
0,103
Avenue С3
660х250х130
660х250х110
11,3
10,7
0,135
Avenue С4
790х250х130
790х250х110
14,2
13,4
0,167
Avenue С5
925х250х130
925х250х130
17,1
16,1
0,2
Avenue S1
T1
260х250х220
260х250х200
4,2
4
0,058
F1
260х250х215
260х250х195
4,1
3,9
F2
260х250х290
260х250х270
4,4
4,2
R
260х250х175
260х250х155
4
3,8
Avenue S2
T1
395х250х220
395х250х200
7,1
6,7
0,09
F1
395х250х215
395х250х195
7
6,6
F2
395х250х290
395х250х270
7,3
6,9
Rх2
395х250х175
395х250х155
7,1
6,7
Avenue S3
F3
530x250x215
530x250x195
10,4
9,8
0,123
Fw
530x250x215
530x250x195
10,2
9,6
Rх2
530x250x175
530x250x155
9,9
9,3
Avenue S4
F3
665x250x215
665x250x195
13,2
12,4
0,155
Fw
665x250x215
665x250x195
13
12,2
Rх2
665x250x175
665x250x155
12,7
11,9
Avenue S5
F3
800х250х215
800х250х195
16,1
15,1
0,188
Fw
800х250х215
800х250х195
15,9
14,9
Rх2
800х250х175
800х250х155
15,6
14,6

9
4DELIVERY SET
4.1 The delivery set of the luminaire is specified in table 4.1.
Table 4.1
Item
Quantity
Commentary
Luminaire
1 pcs.
М10х60 screw
2 pcs.
Avenue СХ-…
Т1 mount set
1 pcs.
Avenue SX-…-T1
F1 mount set
1 pcs.
Avenue SX-…-F1
F2 mount set
1 pcs.
Avenue SX-…-F2
F3 mount set
1 pcs.
Avenue SX-…-F3
Fw mount set
1 pcs.
Avenue SX-…-Fw
R mount set
1 pcs.
Avenue SX-…-R
2 pcs.
Avenue SX-…-Rx2
User manual
1 pcs.
Package
1 pcs.
5SECURITY MEASURES
5.1 In terms of security measures the luminaire is completed in accordance with EN 60598-1,
EN 60598-2-3, EN 60598-2-1, EN 60598-2-5, requirements.
5.2 Installation and maintenance of the luminaire must be executed by skilled specialist,
authorized to work on electrical installations under voltage up to 1000 V.
5.3 Disconnect from power supply before installing and maintaining the luminaire.
5.4 Connecting the luminaire to power supply which properties are different from those
indicated in marking of the luminaire is prohibited.
5.5 The luminaire must be grounded to avoid electric shock.
5.6 DO NOT:
–assemble, disassemble or service a luminaire with connected power supply;
–switch on a disassembled luminaire;
–use a mechanically damaged luminaire;
–use luminaire with the damaged isolation of wires or places of electric connections;
–use luminaire without protective grounding;
–lift and hold the luminaire by the cable;
–use luminaire for unintended purposes.

10
6DESCRIPTION
6.1 Common description
The luminaire has a module structure.
The basic functional unit of the luminaire is the light module, which consists of aluminum
housing, LED light source, driver and secondary optical system (lens with accompanying parts).
Depending on the housing type, there are two types of modules: “Console” and “Middle”.
Depending on the embodiment, luminaires can contain from one to five light modules and one
(Avenue СХ-... option) or two (Avenue SХ-... option) front sections.
Depending on the embodiment, the front section (figure 6.1) may contain the surge protection
module (Avenue -SP-, -SPC-, -SP2-, -SPC2- options) and additional power regulation devices.
To connect luminaire to the power supply an external flexible three-core cable is used.
For expansion of luminaire functions, the front cover may be replaced with ASC (Avenue
Smart Cover) Control Devices in variety of options.
Notes
1 To connect additional power regulating device, or ASC Control Device, the system connector is
used (figure 6.1).
2 ASC Control Device may be installed by the manufacturer, or purchased separately and installed by user to
upgrade the already bought luminaire.
3 Description and exploitation details of ASC Control Device are given in the appropriate user manual.
Figure 6.1 –Front section without removed cover
6.2 Console luminaires (Avenue СХ option)
The console luminaire consist of the Console Light Module and front section (Avenue С1
option) or Console Light Module, front section and from one to four Middle Light Modules (Avenue С2 −
Avenue С5 options).
The console luminaire is equipped with a mounting bracket for set on tubes with diameter from
40 to 65mm.
The construction of mounting bracket allows to set the luminaire on L-type console (figure 6.2)
or vertical pole (figure 6.3) and provides tilt adjustment from minus 5° to +30° with a 2,5° step.

11
Figure 6.2 –Luminaire set on a L-type console
Figure 6.3 - Luminaire set on a vertical pole
6.3 Suspended luminaires (Avenue SХ option)
The suspended luminaire consist of Middle Light Modules (from 1 to 5 depending on the
model) and two front sections.
Suspended luminaires can be equipped with different mount types. List of mount types, their
description and compatibleness with luminaire options is given in table 6.1.
Table 6.1
Code
Title
Description
Compatible
luminaires
Figure
T1
Suspended,
bearing
cable, 3d
For hanging on bearing cable of diameter
from 6 to 12,5 mm.
Adjustability: turn angle 0-360°; slope
angle ±20°.
Avenue S1-…-Т1
Avenue S2-…-Т1
6.4
F1
Narrow
floodlight,
2d
For mount on hard surface (wall, ceiling,
and metal construction). Adjustability: turn
angle 0-360°; slope angle ±20°.
Avenue S1-…-F1
Avenue S2-…-F1
6.5
F2
Narrow
floodlight,
3d
For mount on hard surface (wall, ceiling,
and metal construction). Adjustability: turn
angle 0-360°; longitudinal slope angle ±20°;
transversal slope angle ±90°.
Avenue S1-…-F2
Avenue S2-…-F2
6.6

12
Continuation of table 6.1
Code
Title
Description
Compatible
luminaires
Figure
F3
Wide
floodlight,
lyre
For mount on hard surface (wall, ceiling,
and metal construction). Adjustability:
transversal slope angle ±90°.
Avenue S3-…-F3
Avenue S4-…-F3
Avenue S5-…-F3
6.7
Fw
Wide
floodlight,
separated
For mount on hard surface (wall, ceiling,
and metal construction). Adjustability:
slope angle in transversal plane ±90°;
distances between mounting brackets.
Avenue S3-…-Fw
Avenue S4-…-Fw
Avenue S5-…-Fw
6.8
R
Suspended,
eye nut
For mount on ceiling by suspended steel
rope with diameter of 4 mm and more. One
attachment point.
Avenue S1-…-R
6.9
Rх2
Suspended,
eye nut, 2 pcs.
For mount on ceiling by suspended steel
rope with diameter of 4 mm and more.
Two attachment points.
Avenue S2-…-Rx2
Avenue S3-…-Rx2
Avenue S4-…-Rx2
Avenue S5-…-Rx2
6.9

13
Figure 6.4 –Т1 mount
Figure 6.5 –F1 mount

14
Figure 6.6 –F2 mount
Figure 6.7 –F3 mount

15
Figure 6.8 –Fw mount
Figure 6.9 –R (Rx2) mount

16
7PRE-LAUNCH PROCEDURE
7.1 Unpack the luminaire and check its integrity and assembly correctness.
7.2 Power supply connection
Connection to the power grid must be executed in accordance to national installation rules.
An external three-core cable is used to connect the luminaire to the power supply.
For correct connection be aware of the wires colour denotation:
–brown for "phase" (L);
–blue for "zero" (N);
–yellow-green for grounding.
It is recommended to use a terminal block, which conforms to EN 60998-2-1 or EN 60998-2-2
and fulfills such requirements:
–rated voltage - 300 W;
–rated current - 4 A;
–rated connecting capacity –2,5 mm2.
Notes
1 To maintain declared ingress protection level use terminal blocks with appropriate protection level.
2 Execute any necessary preparation of the ends of conductors in a way meant by terminal block manufacturer.
7.3 Console luminaires (Avenue СХ option)
7.3.1 The luminaire should be installed following such requirements:
–the luminaire’s normal working position on L-type console (or on vertical support bracket) is
at angle from 0° to 30° to horizon;
–the recommended setting height is from 3 to 30 meters (dependently on the luminaire option
and specific of its exploitation);
–the tube wall thickness must be not less than 1,5 mm;
–tube diameter should be from 40 to 65 mm. To fasten the luminaire on tube with diameter
from 40 to 54 mm use adjusting screw-bolts from the delivery set;
–the depth of the pole inset into the console holder must be at least 90 mm;
–tightening torque for fastening bolts must be not less than 17 Nm.
Warning!
Minimum distance from lighted objects not less than 1 m.
7.3.2 To install the luminaire on vertical pole, change the position of the holder, as shown in
figure 7.1.
Figure 7.1 –Holder adjustment for vertical set

17
7.3.3 Luminaire installation order:
–connect the power wire. The luminaire cable must be passed inside of the tube;
–release fastening bolts and set the luminaire on L-type console or vertical pillar. Ensure that
the cable was not damaged by squeezing between surfaces and cuts of tubes;
–fix the luminaire by tightening fastening bolts. Tighten check-nuts;
–loose adjusting screws, adjust the luminaire tilt on vertical axis, then fix it at necessary angle
by tightening adjusting screws;
–switch on the power and check if the luminaire is working properly.
7.4 Suspended luminaires (Avenue SХ option)
7.4.1 The luminaire should be installed according to the following requirements::
–the normal working position of the luminaire depends on its model and specific of its
exploitation;
–for F1, F2, F3 and Fw mount type, if the luminaire is exposed to precipitation, it is
recommended to orientate it vertically (along the longitudinal axis);
–for T1 mount type the diameter of bearing cable must be from 6 to 12,5 mm;
–for R and Rx2 mount type usea steel rope with diameter no less than 4 mm;
–to hang the luminaire with F1, F2, F3 and Fw mount use screws or screw-bolts with diameter
from 5 to 6,5 mm.
Notes
1 Screws, screw-bolts and dowels for attachment of luminaire upon mounting surface are not included in the delivery set
and should be purchased separately.
2 Type and size of screws, screw-bolts and dowels should be chosen in dependence on type and material of mounting
surface.
Warning!
Minimum distance from lighted objects not less than 1 m.
7.4.2 The luminaire installation order:
–set the Т1, F1, F2 mount kit on the luminaire as shown in figures 7.2-7.4.
Note: F3, Fw, R and Rx2 mount are installed by the manufacturing enterprise;
–fasten the luminaire on:
steel rope (Т1 mount);
mounting surface (F1, F2, F3 and Fw mount);
suspended steel ropes (R and Rx2 mount);
–connect power wires;
–adjusting position of the luminaire:
For Т1 and F1 mount (figures 7.2 and 7.3). Loosen М8 nuts and adjust the turn and tilt
angle. Tighten М8 nuts to fix the luminaire;
For F2 mount (figure 7.4). Loosen М8 nuts and adjust the turn and elevation angles. To
fix the luminaire, tighten М8 nuts. Loosen М6 nuts on the М6х20 screws (see figure 7.4)
and adjust the tilt angle in transversal plane. To fix the luminaire, tighten М6 nuts. To
change the tilt adjustment range, move the М6х20 screws with the М6 nuts into
corresponding hole on U bracket (see figure 6.6);
For F3 and Fw mount (figures 7.5 and 7.6). Loosen М6 nuts on the М6х20 screws and
adjust the tilt angle. To fix the luminaire, tighten М6 nuts. To change the tilt adjustment
range, move the М6х20 screws with М6 nuts into corresponding hole on turning bracket (see
figure 6.8).
Note: Fw mount allows to change the distance between mounting brackets. For this purpose, loosen М4
screws and move turning brackets (see figure 7.6) on necessary distance. To fixate brackets tighten М4
screws;
–switch on the power and check that the luminaire is working properly.

18
Figure 7.2 –T1 mount installation
Figure 7.3 –F1 mount installation

19
Figure 7.4 –F2 mount installation
Figure 7.5 –F3 mount installation

20
Figure 7.6 –Fw mount installation
Figure 7.7 –R (Rx2) mount installation
This manual suits for next models
36
Table of contents
Popular Outdoor Light manuals by other brands

urban ambiance
urban ambiance UQL1143 installation instructions

MONTEAUX
MONTEAUX 51462 BK-S-4pk Use and care guide

AURAXY
AURAXY SF8 user manual

The Hampton Bay
The Hampton Bay 736-809 instruction manual

HUDSON VALLEY LIGHTING
HUDSON VALLEY LIGHTING mitzi JESSA Assembly and mounting instructions

CAST Lighting
CAST Lighting Impressionist Series quick start guide

Tracon Electric
Tracon Electric LALB4W user manual

SEBSON
SEBSON SDL FLEXIBLE 2W V2 user manual

Light Efficient Design
Light Efficient Design LED-8090MXX-G4-OCC Installation and user guide

Sistemalux
Sistemalux MINI LOOK instruction sheet

Govee
Govee H705A user manual

LIGMAN
LIGMAN LD-50101 installation manual