Lavor AC27 User manual

Mobile Industrial Air Conditioner
User Manual
Models: AC27, AC45, AC65

Thank you very much for choosing our Lavor Pro Mobile Workshop Cooler.
To ensure safe and efficient use of your new Cooler, please read the Manual
carefully.
Contents
I. Safety Signs and Precautions…………………………
II. Technical Parameters………………………………
III. Electrical Schematic Diagram………………………………
IV. Product Structure………………………………………
V. Installation Method……………………………………
VI. Installation Method of Extended Hot Exhaust Pipe……
VII. Operation Method…………………………
VIII. Water Tank……………………………………
IX. Drainpipe………………………………
X. Requirement for Machine Operating Site……………………
XI. Maintenance and Check……………………………………
XII. Fault Cause and Countermeasure…………………………
XIII. Correct Disposal of this product …………………………

I. Safety Signs and Precautions
Meaning and identification of signs
Please read the safety signs and precautions carefully before using the machine.
Danger
Incorrect use while ignoring the sign may cause casualty
accident, fire and other property losses.
Warning
Incorrect use while ignoring the sign may cause casualty
accident, fire and other property losses.
Forbidden
The sign indicates actions that are forbidden.
Constraint
The sign indicates constraint and instruction.
The sign indicates and urges to notice the contents.

Attention
Matters prompted in the following column may possibly cause grave consequences due to
different situations.
All records are important. Please do read them carefully and observe.
If the supply cord is damaged, it must be replaced by a
special cord or assembly available from the manufacturer
or its service agent.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved
Children shall not play with the appliance
Cleaning and user maintenance shall not be made by
children without supervision

This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for
commercial use by lay persons
Disconnect the appliance from its power source during
service and when replacing parts
Please do not use air cooler in places that use or store
volatile substances (diluents, gasoline, kerosene, liquefied
gas and other volatile liquids; magnesium, aluminum, lead
and other volatile dusts and vapors) to avoid possible
ignition, explosion, fire and burn.
Please do not remold for use, which may lead to machine
breakdown or even fire, etc.
Except for professional maintenance personnel, other
personnel are not allowed to assemble or disassemble to
avoid fire, electrocution, injury and other safety accidents.
If repair is needed, please contact the after-sales service
department at the place of purchase.

Please do not use it in places with rain and snow water.
Do not operate with wet hands.
Please use 220-240V~50Hz, power supply; Otherwise
there might be machine breakdown or safety accident.
Please separately use socket of 20A rated current. Use of
socket with other electrical appliances may cause error.
Please do assign professionals to operate according to
equipment standard and wiring upon installation;
Otherwise there may be safety accident.
Please do not get near fire source to avoid deformation of
machine.
Please equip safe and reliable ground lead and use leakage
protector.
Please use it in specified range of 18℃~45℃; otherwise
there may be machine breakdown.

Do not move air cooler when the machine is running and
set the brake of trundle to locked status.
Please immediately stop using it in case of error (stopped
rotation, strange noise, improper vibration and unusual
odor).
To prevent disaster and damage, air cooler cannot be used
in the following places:
Vibrating floor
Gradient floor
Stairway, emergency exit and house exit and entrance,
etc.
Place with unstable articles piled around
Windy and moist place or place with floating metal
powder
Please grip the plug when pulling it off instead of pulling
the power line directly. Otherwise it may damage the
plug, or cause sparkle or safety accident.

Please pull the power plug off the socket if the machine is
not used for long terms.
To prevent electrocution, please pull the power plug off
the socket upon installation and maintenance.
Please use dry and clean cloth to rub down the dust on
power plug on schedule. Dusty or moist plug may cause
poor contact or electric leakage, leading to safety
accident.
Do not haphazardly bend, drag, twist, pinch or change the
power line. Do not overload the power line. Otherwise
there may be fire, electrocution and other accidents.
Please do not use it as air conditioner for boat and vehicle,
etc. Otherwise there may be safety accident.
Please do not stick finger or hand in the vent.

II. Technical Parameters
Model AC27 AC45 AC65
Power 220-240V/50Hz 220-240V/50Hz 220-240V/50Hz
Refrigerating Capacity 2700W 4500W 6500W
Rated Power 950W 2000W 3000W
Rated Current 4.2A 9A 13.5A
Blast Capacity 400m3/h 800m3/h 1200m3/h
Working Pressure on
Suction/Exhaust Side
2.5/4.5MPa 2.5/4.5MPa 2.5/4.5MPa
Max Working Pressure of Heat
Exchanger
4.5MPa 4.5MPa 4.5MPa
Refrigerant/Charge Quantity R410a/460g R410a/800g R410a/1050g
Service Environment 18℃~45℃ 18℃~45℃ 18℃~45℃
Net Weight 42kg 70kg 100kg
Gross Weight 47kg 75kg 155kg
External Dimension 405 *430 *855 610*570*1110mm
740*660*1730mm

III. Electrical Schematic Diagram
Model: BGK1801-45, BGK1801-65 Elementary Wiring Diagram

IV. Product Structure

V. Installation Method
Installation method of elbow: point the turning of the elbow to the dent of the detachable
elbow base on the machine, insert it in and rotate it anticlockwise. The elbow is in place
when a sound of crack is heard (Fig.1).
Hot Exhaust
Pipe
Cold Exhaust
Pipe
Water Tank
Handle
Filter Screen
Front Shell
Switch Box
Trundle
Right Plate

Installation method of cold exhaust pipe: point the turning of the cold exhaust pipe to the
dent of the cold exhaust pipe, insert it in and rotate it to the left to make it in place (Fig.1).
(Fig. 1)
Installation of hot exhaust pipe: insert the hot exhaust pipe in the heat vent. Do install it in
place to guarantee stable and firm hot exhaust pipe (Fig.2).

(Fig. 2)
Change of Connection of Power Line
Warning: if the line cord is broken, the power line must be replaced by
professionals from the manufacturer, its maintenance department or similar
department to avoid danger.
VI. Installation Method of Extended Hot Exhaust Pipe
Install extended pipe to exhaust the heat to outdoors.
Ask professional to cut a hole on the wall to install the hot exhaust pipe.
Please do guarantee smooth heat extraction of the hot exhaust pipe.

Please do not fall foreign object in the hot exhaust pipe.
The outdoor opening of the hot exhaust pipe shall be equipped with rainwater-
proof backflow device (or bend a certain angle downward directly).
※ Extended hot exhaust pipe shall be separately purchased from the Company. The
specification shall be Φ160x3m.
Please ensure smooth heat extraction of the hot exhaust pipe.

Please do not fall foreign object in the hot exhaust pipe. The outdoor opening of the hot
exhaust pipe shall be equipped with rainwater-proof backflow device (or bend a certain
angle downward directly).
※ Extended hot exhaust pipe shall be separately purchased from the Company. The
specification shall be Φ160x3m.
Method of Cutting of Extended Pipe
Please cut the extended pipe based on the extended length needed.
As is shown in the figure, separate the exhaust pipe from the groove with a flathead
screwdriver or other sharp tools at where it is supposed to be cut, and cut it off with pliers
or scissors.
Method of Reducing the Diameter of Extended Pipe
Rotate the exhaust pipe clockwise to reduce the diameter of pipe opening.

Method of Connecting Extended Pipe
Detach the joint of the hot exhaust pipe and cover the extended pipe outside the hot
exhaust pipe. Screw the end tight and cling to it.
Use adhesive tape to fixate it if necessary. Use binder to fixate the attached pipe opening
of the extended hot exhaust pipe.
VII. Operation Method
Operation Method and Blast Capacity Choosing
Rotate the selecting switch on the cover of the machine to or and the compressor

immediately launches refrigeration. In the meantime, start the draught fan to blow air out.
The blast capacity has or for customer to choose from.
When the switch is rotated to “0”, the machine is off and stops running.
Attention
Please turn the selecting switch off and cut the power off before moving the machine.
When the machine is off, it may be restarted after 3 minutes.
Compressor Overheat and Overload Protection
Overly high or low voltage and overly high environment temperature may cause the
compressor to overhead and overload. To protect the compressor, the overload protector
will be activated to cut the power of the compressor off.
Attention
When the overload protector is activated, the machine only blows out natural wind but
does not refrigerate. If the overload protector is activated frequently, please find out and
eliminate the cause before using the machine.
Range and Operation of Adjustment of Air-out Direction
Cold air pipe may rotate left or right to 360 degrees (hot air pipe is installed).
Cold air pipe may be moved up or town to 150 degrees.
The range of adjustment angle for hot air pipe is 45 degrees.

Attention
Please adjust the cold exhaust pipe in advance and use the air-out direction of the hot exhaust
pipe later. When adjusting the air-out angle of cold exhaust pipe, please grip the elbow for
adjustment and do not hold the cold exhaust pipe directly.
VIII. Water Tank
Method of using water tank: when the water in the tank and the end face on the tank

handle are parallel, set the gear to 0, pour the water out and reinstall the water tank. Choose a
gear to make it work properly.
Attention: Please do not move the machine when the water is full. Pour the water before
moving it.
IX. Drainpipe (Optional)
Condensate water may be discharged from the drainpipe directly.
Method: take the water tank out and put the drainpipe directly on the outfall of the tank to
cross the round hole on the corresponding side plate.
X. Requirement for Machine Operating Site
Special Reminder for Users:
When the machine is running, both the filter screen and the cold air pipe shall be
This manual suits for next models
2
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual