LBG Products LBH09AWO User manual



LBH09AWO
LBH12AWO
LBH09DWO


CONTENTS
Safety precautions
......................................................................................
01
..................................................................................................
05
.........................................................................................
06
............................................................................
08
.......................................................................................
10
..................................................................
11
Parts name
Installation notice
Installation of outdoor unit
Test and operation
Configuration of connection pipe

Explanation of Symbols
WARNING
CAUTION
NOTICE
1.Damage the product due to improper use or misuse of the product;
2.Alter, change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer;
3.After verification, the defect of product is directly caused by corrosive gas;
4.After verification, the defects are due to improper operation during transportation
of product;
5.Operate, repair, maintain the unit without abiding by instruction manual or related
regulations;
6.After verification, the problem or dispute is caused by the quality specification or
performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force
majeure.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property loss is
caused by the following reasons.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to
property.
Indicates important but not hazard-related
information, used
to indicate risk of property damage.
If it needs to install, move or maintain the air conditioner, please contact dealer
or local service center to conduct it at first. Air conditioner must be installed,
moved or maintained by appointed unit. Otherwise, it may cause serious damage
or personal injury or death.
When refrigerant leaks or requires discharge during installation, maintenance, or
disassembly, it should be handled by certified professionals or otherwise in
compliance with local laws and regulations.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

Safety precautions
Installation
1
WARNING
Installation or maintenance
must be performed by qua-
lified professionals.
The appliance shall be in-
stalled in accordance with
national wiring regulations.
According tothe local safe-
ty regulations, use quali-
fied power supply circuit
and circuit breaker.
All wires of indoor unit and
outdoor unit should be con-
nected by a professional.
Be sure to cut off the power
supply before proceeding
any work related to elec-
tricity and safety.
Make sure the power supp-
ly matches with the require-
ment of air conditioner.
Unstable power supply or
incorrect wiring may result
in electric shock, fire haza-
rd or malfunction. Please
install proper power supply
cables before using the air
conditioner.
The grounding resistance
should comply with nation-
al electric safety regula-
tions.
Air Conditioner should be
properly grounded. Inco-
rrect grounding may cause
electric shock.
Do not put through the
power before finishing in-
stallation.
Do install the circuit brea-
ker. If not, it may cause
malfunction.
An all-pole disconnection
switch having a contact se-
paration of at least 3mm in
all poles should be conne-
cted in fixed wiring.
Circuit breaker should be
included magnet buckle
and heating buckle func-
tion. It can protect the
overload and circuit-short.

Safety precautions
Installation
2
CAUTION
Instructions for installation
and use of this product are
provided by the manufac-
turer.
Select a location which is
out of reach for children
and far away from animals
or plants. If it is unavoid-
able, please add the fence
for safety purpose.
The indoor unit should be
installed close tothe wall.
Don't use unqualified pow-
er cord.
If the length of power con-
nection wire is insufficient,
please contact the supplier
for a new one.
The appliance must be po-
sitioned sothat the plug is
accessible.
For the air conditioner with
plug, the plug should be re-
achable after finishing in-
stallation.
For the air conditioner with-
out plug, a circuit breaker
must be installed in the
line.
The yellow-green wire in
air conditioner is ground-
ing wire, which can't be us-
ed for other purposes.
The air conditioner is the
first class electric applian-
ce. It must be properly gro-
under with specialized gr-
ounding device by a pro-
fessional. Please make
sure it is always ground-
ed effectively, otherwise it
may cause electric shock.
The temperature of refri-
gerant circuit will be high,
please keep the interconn-
ection cable away from the
copper tube.

Safety precautions
Operation
and Maintenance
3
WARNING
This appliance can be used
by children aged from 8
years and above and per-
sons with reduced physi-
cal, sensory or mental ca-
pabilities or lack of expe-
rience and knowledge if
they have been given su-
pervision or instruction con-
cerning use of the applian-
ce in a safe way and un-
derstand the hazards in-
volved.
Children shall not play with
the appliance.
Cleaning and user main-
tenance shall not be made
by children without super-
vision.
If the supply cord is damag-
ed, it must be replaced by
the manufacturer, its ser-
vice agent or similarly qua-
lified persons in order to
avoid a hazard.
Do not connect air condi-
tioner to multi-purpose soc-
ket. Otherwise, it may cau-
se fire hazard.
Do disconnect power supp-
ly when cleaning air condi-
tioner. Otherwise, it may
cause electric shock.
Do not wash the air condi-
tioner with water to avoid
electric shock.
Do not spray water on in-
door unit. It may cause ele-
ctric shock or malfunction.
Do not repair air condition-
er by yourself. It may cause
electric shock or damage.
Please contact dealer when
you need to repair air con-
ditioner.
After removing the filter, do
not touch fins to avoid in-
jury.
Do not extend fingers or
objects into air inlet or air
outlet. It may cause person-
al injury or damage.

Safety precautions
Operation
and Maintenance
4
CAUTION
Do not spill water on the re-
mote controller, otherwise
the remote controller may
be broken.
Do not use fire or hair dry-
er to dry the filter to avoid
deformation or fire hazard.
Do not block air outlet or
air inlet. It may cause mal-
function.
Do not step on top panel of
outdoor unit, or put heavy
objects. It may cause dam-
age or personal injury.
When below phenomenon
occurs, please turn off air
conditioner and disconnect
power immediately, and
then contact the dealer or
qualified professionals for
service.
Power cord is overheat-
ing or damaged.
There’s abnormal sound
during operation.
Circuit breaker trips off
frequently.
Air conditioner gives off
burning smell.
Indoor unit is leaking.

5
Parts name
Outdoor Unit
●
Actual product may be different from above graphics, please refer to actual product.
air inlet
air outlet
NOTE

Installation notice
Drainage pipe
Space to the obstruction
At least 50cm
Space to the obstruction
At least 30cm
Space to the obstruction
At least 50cm
Space to the obstruction
At least 200cm
At least 30cm
Space to the wall
6
■
■
■
■
■
7
■
To ensure safety, please be mindful of the
following precautions.
■
12
2813
39
4
5
14
10
611
■
WARNING
Please contact the local agent for installation.
Don’t use unqualified power cold.
When installing the unit, make sure that co-
nnection pipe is securely connected before
the compressor starts running.
If compressor starts running when stop valve
is open and connection pipe is not yet conne-
cted, air will be sucked in and cause pressure
rise or compressor rupture, resulting in injury.
WARNING
Prohibit installing the unitat the place where
there may be leaked corrosive gas or flamm-
able gas.
If there is leaked gas around the unit, it may
cause explosion and other accidents.
Do not use extension cords for electrical co-
nnections. If the electric wire is not long eno-
ugh, please contact a local service center au-
thorized and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Tools for installation
Screw driver
Impact drill
Open-end
Pipe cutter
wrench
detector
Leakage
Vacuum pump
Level meter
Pressure meter
When refrigerant needs to be recovered
during relocating or repairing the unit,be
Universal
meter
When installing or relocating the unit, be s-
ure to keep the refrigerant
circuit free from
air or substances other than the specified
refrigerant.
Any presence of air or other foreign substance
in the refrigerant circuit will cause
system pre-
ssure rise or compressor rupture, resulting
in injury.
Measuring
tape
spanner
Inner hexagon
When in
stalling or moving this unit, do not
charge the refrigerant which is not comply
with that on the nameplate or unqualified
refrigerant.
Otherwise, it may cause abnormal operation,
wrong action, mechanical malfunction or even
serious safety accident.
sure that the unit is running in cooling mode.
Then, fully close the valve at high pressure
side (liquid valve). About 30-40 secondslater,
fully close the valve at low pressure side
(gas valve), immediately stop the unit and
disconnect power. Please note that the time
for refrigerant recovery should not exceed
1 minute.
Drill head
Electric wires with insufficient capacity, wrong
wire connections and insecure wire terminals
may cause electric shock or fire.
Pipe expander
●
●
Torque wrench
Use the specified types of wires for electrical
connections between the indoor and outdoor
units. Firmly clamp the wires so that their te-
rminals receive no external stresses.
If refrigerant recovery takes toomuch time,
air may be sucked in and cause pressure
rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that
liquid valve and gas valve are fully closed
and power is disconnected before detachi-
ng the connection pipe.
If compressor starts running when stop valve
is open and connection pipe is not yet conn-
ected, air will be sucked in and cause pressure
rise or compressor rupture, resulting in injury.
Safety precautions for installing and
relocating the unit
NOTICE

8.
2.
Selection of installation location Requirements for electric connection
Basic requirement
Installing the unit in the following places may cau-
se malfunction. If it is unavoidable, please consu-
lt the local dealer:
3.
4.
5.
6.
7.laundry.
It’s not allowed to be installed on
the unstable
or motive base structure
(such as truck) or in
the corrosive environ
ment (such as chemical
factory).
The place near coast area.
The place with oil or fumes in the air.
The place with sulfureted gas.
Other places with special circumstances.
The appliance shall not be installed in the
flammable or explosive gas, or volatile objects
spread in the air.
1.The place with strong hea t sources, vapors,
The place with high-frequency devices (such
as welding machine, medical equipment).
8.The temperature of refrigerant circuit will be hi-
gh, please keep the interconnection cable away
from the copper tube.
with national wiring regulations.
9.The appliance shall be installed in accordance
7
6.Do not put through the power before finishing
installation.
4.
7.
If the supply cord is damaged, it must
be repla-
3.
ced by the manufacturer, its
service agent or
similarly qualified
persons in order to avoid a
hazard.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Make sure the power supply matches with the
requirement of air conditioner.
Unstable power
supply or incorrect wiring or malfunction. Pl-
ease install proper power supply cables before
using the air
conditioner.
5.Be sure to cut off the power supply
before pr-
oceeding any work related to
electricity and safety.
Outdoor unit
1.Select a location where the noise and outflow
3.
neighborhood.
2.The location should be well ventilated and dry,
in which the outdoor unit won't be exposed dir-
ectly to sunlight or strong wind.
The location should be able to withstand the
Select a location which is out of reach for chil-
air emitted by the outdoor unit will not affect
5.dren and far away from animals or plants. If it
is unavoidable, please add the fence for safety
purpose.
uirement of installation dimension diagram.
weight of outdoor unit.
4.Make sure that the installation follows the req-
Safety precaution
1.
2.
Must follow the electric safety regulations w-
hen installing the unit.
According to the local safety regulations, use
qualified power supply circuit and air switch.
4.
5.
2.
An all-pole disconnection switch having a co-
ntact separation of at least 3mm in all poles
should be connected in fixed wiring.
3.
The yellow-green wire in air conditioner is
grounding wire, which can't be used for other
purposes.
The grounding resistance should comply with
Grounding requirement
national electric safety regulations.
The appliance must be positioned so that the
p
l
u
g is accessible.
1.T
he air conditioner is the first class
electric
appliance. It must be properly grounded with
specialized grounding
device by a professional.
Please make
sure it is always grounded effecti-
vely, otherwise it may cause electric shock.

Installation of outdoor unit
drain vent
Drain hose
Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
foot holes
foot holes
at least 3cm above the floor
1. Remove the screw on the right handle of out-
handle
Remove the screw cap of valve and aim the
pipe joint at the bellmouth of pipe.
2.
gas valve
3.
2.
union nut
Step 1:
Fix the support of outdoor unit
(select it according to the actual inst-
2.
chassis
outdoor drain joint
NOTICE
Take sufficient protective measures when installing
the outdoor unit.
Make sure the support can withstand at least four
times of the unit weight.
The outdoor unit should be installed at least
3cm above the floor in order to install drain joint.
(for the model with heating tube, the installation
height should be no less than 20cm.)
For the unit with cooling capacity of 2300W
~
5000W,
6 expansion screws are needed; for
the unit with cooling capacity of 6000W~8000W,
8 expansion screws are needed; for the unit
with cooling capacity
of 10000W~16000W, 10
expansion screws are needed.
Step 4:
Connect indoor and outdoor pipes
door unit and then remove the handle.
screw
liquid pipe
gas pipe
Step 2:
Install drain joint
(only for some models)
1.
liquid
valve
Connect the outdoor drain joint into the hole
on the chassis, as shown in the picture below.
Connect the drain hose into the drain vent.
NOTICE
As for the shape of drainage joint, please refer
to the current product. Do not install the drainage
joint in the severe cold area. Otherwise,it will be
frosted and then cause malfunction.
allation situation)
1. Select installation location according to
Step 3:
Fix outdoor unit
1.
Pretighten the union nut with hand.
pipe joint
the house structure.
Fix the support of outdoor unit on the sele-
cted location with expansion screws.
8

4.
2.
1.
The water outlet can't be placed in water in
order to drain smoothly.
The drain hose can't be fluctuant
2.
Step 5:
Connect outdoor electric wire
wall
U-shaped curve
drain hose
the drain hose
can't raise
upwards.
The water outlet
can't be placed
in water
The wiring board is for reference only, please refer
to the actual one.
The drain hose
After tighten the screw, pull the power cord slightly
to check if it is firm.
Never cut the power connection wire to prolong or
shorten the distance.
can't be fluctuant The water
outlet can't be
fluctuant
Step 6:
Neaten the pipes
Remove the wire clip; connect the power con-
nection wire and signal control wire (only for
cooling and heating unit) to the wiring terminal
according to the color; fix them with screws.
9
Fix the power connection wire and signal con-
trol wire with wire clip (only for cooling and h-
eating unit).
1.
Slant the drain hose slightly downwards.
The drain hose can't be curved, raised and
fluctuant, etc.
The through-wal height of drain hose shoul
not be higher than the outlet pipe hole of in-
door unit.
Tighten the union nu t with torque wrench
by referring to the sheet below.
15~20
30~40
45~55
60~65
70~75
1/4''
3/8''
1/2''
5/8''
3/4''
NOTICE
NOTICE
Hex nut diameter Tightening torque(N m)
.
NOTICE
reasonably and hidden possibly. Min. semidiam-
eter of bending the pipe is 10cm.
The pipes should be placed along the wall, bent
L1 L2
black
Indoor unit connection
black(brown)
green
(yellow-green)
white
(blue)
L2
L1
green(yellow-green)
POWER
white
(blue)
red
(brown)
N(1) 2 3
09K、12K
N L
black
Indoor unit connection
black(brown)
green
If the outdoor unit is higher than the wall hole,
you must set a U-shaped curve in the pipe
before pipe goes into the room, in order to
prevent rain from getting into the room.
(yellow-green)
white
(blue)
L
N
green(yellow-green)
POWER
white
(blue)
red
(brown)
3)1(N 2
:
09K、12K:
For some models:
white
black
red
L1 L2
Indoor unit connection
POWER
(blue)
(brown)
white
(blue)
N(1) 2 3
black
(brown)
L1 L2
green
green)
(yellow-
green
green)
(yellow-
18K、24K:

Test and operation
6. Tighten the screw caps of valves and refriger-
ant charging vent.
Leakage detection
Use vacuum pump
Remove the valve caps on the liquid valve and
1.
1.
2.
5. Remove the piezometer, open the valve core
Reinstall the handle.7.
of liquid valve and gas valve completely with
inner hexagon spanner.
piezometer
valve cap
Lo Hi
liquid valve
gas valve
refrigerant charging
vent
nut of refrigerant
charging vent
close
open
vacuum pump
inner hexagon
spanner
for 10-15min to check if the pressure of piezo-
meter remains in -0.1MPa.
4. Close the vacuum pump and maintain this sta-
tus for 1-2min to check if the pressure of piezo-
meter remains in -0.1MPa. If the pressure de-
creases, there may be leakage.
10
3.
Open the piezometer completely and operate
refrigerant charging vent of gas valve and then
connect the other charging hose to the vacuum
pump.
With leakage detector:
Check if there is leakage with leakage detector.
With soap water:
If leakage detector is not available, please use
soap water for leakage detection. Apply soap
water at the suspected position and keep the
soap water for more than 3min. If there are air
bubbles coming out of this position, there's a
leakage.
gas valve and the nut of refrigerant charging vent.
2.
Connect the charging hose of piezometer to the
Check after installation
Test operation
●
1.
●
●
Check according to the following requirement
after finishing installation.
Preparation of test operation
The client approves the air conditioner.
Specify the important notes for air conditioner to
the client.
Items to be checked Possible malfunction
The unit may drop, shake or
emit noise.
Has the unit been
installed firmly?
Is water drained well? It may cause condensation
and water dripping.
Have you done the refri-
gerant leakage test? It may cause insufficient
cooling(heating) capacity.
It may cause malfunction or
damage the parts.
Is electric wiring and pip-
eline installed correctly? It may cause malfunction or
damage the parts.
Is the unit grounded
securely?
Does the power cord fol-
low the specification? It may cause malfunction or
damage the parts.
Is there any obstruction in
the air inlet and outlet?
Is heat insulation of pipe-
line sufficient?
It may cause malfunction or
damage the parts.
The gas valve and liquid
valve of connection pipe
are open completely?
The dust and sundries
caused during installation
are removed?
It may cause condensation
and water dripping.
It may cause electric leakage.
Is the inlet and outlet of
piping hole been covered?
Is the voltage of power
supply according to the
voltage marked on the
nameplate?
It may cause insufficient
cooling(heating) capacity.
It may cause insufficient
cooling (heating) capacity.
It may cause insufficient
cooling (heating) capacity
or waste electricity.
●
●
2.
●Method of test operation nonottubFFO/NOsserp,rewopehthguorhttuP
the remote controller to start operation.
Press MODE button to select AUTO, COOL, DRY,
FAN and HEAT to check whether the operation is
normal or not.
If the ambient temperature is lower than 16°C(61°F),
the
air conditioner can’t start cooling.

1.
15
15
15
Max. length of
connection pipe(m)
20
25
25
30
30
30
30
5000Btu/h (1465W)
7000Btu/h (2051W)
9000Btu/h (2637W)
12000Btu/h (3516W)
18000Btu/h (5274W)
24000Btu/h (7032W)
28000Btu/h (8204W)
36000Btu/h (10548W)
42000Btu/h (12306W)
48000Btu/h (14064W)
Cooling capacity
Max. length of connection pipe
Pipe expanding method
pipe cutter
pipe
Configuration of connection pipe
A: Cut the pipe
2.
3.
leaning
uneven burr
Standard length of connection pipe: 5m, 7.5m,
8m.
Min. length of connection pipe is 3m.
Max. length of connection pipe is shown as below.
4. The additional refrigerant oil and refrigerant charg-
ing required after prolonging connection pipe.
After the length of connection pipe is prolonged
for 10m at the basis of standard length, you should
add 5ml of refrigerant oil for each additional 5m
of connection pipe.
The calculation method of additional refrigerant
charging amount(on the basis of liquid pipe):
Additional refrigerant charging amount =
prolonged length of liquid pipe × additional
refrigerant charging amount per meter
Basing on the length of standard pipe, add re-
frigerant according to the requirement as shown
in the table. The additional refrigerant charging
amount per meter is different according to the
diameter of liquid pipe. See the following sheet.
Confirm the pipe length according to the distance
of indoor unit and outdoor unit.
Cut the required pipe with pipe cutter.
NOTICE
Improper pipe expanding is the main cause ofrefriger-
ant leakage. Please expand the pipe according to the
following steps:
Additional refrigerant charging amount for R22,
R407C, R410A and R134a
15 20
15 50
30 120
60 120
250 250
350 350
Gas pipe
3/8'' or 1/2''
5/8'' or 3/4''
3/4'' or 7/8''
1'' or 1 1/4''
_
_
Piping size
Liquid pipe
Outdoor unit throttle
Cooling only(g/m) Cooling and
heating(g/m)
1/4''
1/4'' or 3/8''
1/2''
5/8''
3/4''
7/8''
11

smooth surface
improper expanding
shaper
downwards the length is equal
leaning damaged crack
surface
C: Put on suitable insulating pipe
union pipe
pipe
expander
pipe
26.7/-(80/-)
A(mm)
Max Min
1.3 0.7
1.6 1.0
●
The operating temperature range (outdoor temper-
"A" is different according to the diameter, please refer
to the sheet below:
1.8 1.0
Expand the port with expander.
2.4 2.2
12
uneven
thickness
Working temperature range
hard
mold
Maximum
cooling
DB/WB(°C /°F)
26.7/19.4
(80/67) 50/24
(122/75)
Outdoor side
NOTICE
●
Maximum
heating 30/18
(86/65)
Outer diameter
(mm)
LBH09AWO,LBH12AWO
ature) for cooling is -25°C(-13°F)~50°C(122°F); for
heating is -30°C(-22°F)~30°C(86°F).
Φ6 - 6.35(1/4")
Φ9 - 9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
DB/WB(°C /°F)
Indoor side
B: Remove the burrs
●Remove the burrs with shaper and prevent the
D: Put on the union nut
pipe and outdoor valve;
install the union nut on
the pipe.
●
E: Expand the port
●
Remove the union nut on the indoor connection
Check the quality of expanding port. If there is
F: Inspection
●
NOTE
burrs from getting into the pipe.
pipe
any blemish, expand the port again according to
the steps above.


66129937352
This manual suits for next models
2
Table of contents
Other LBG Products Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries DXK05ZTLA-WF user manual

Frigidaire
Frigidaire FRS09PYW1 installation guide

Mitsubishi Electric
Mitsubishi Electric Mr.SLIM MS24WN Service manual

Cooler Master
Cooler Master Silent Pro Gold 450W user manual

Hitachi
Hitachi RAM-55QH4 Service manual

Airwell
Airwell AW-CFM012-N11 Service manual

Dometic
Dometic BRISK AIR 579 SERIES installation instructions

Fujitsu
Fujitsu AF Series operating manual

Gree
Gree Neo COZY9K owner's manual

Daikin
Daikin Super Multi NX 3MKS50E3V1B Service manual

Mitsubishi Electric
Mitsubishi Electric Mr. SLIM PKA-M-LAL Series installation manual

Honeywell
Honeywell CL48PM user manual