manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lectrosonics
  6. •
  7. Rack & Stand
  8. •
  9. Lectrosonics RMPM2T-1 Instruction manual

Lectrosonics RMPM2T-1 Instruction manual

RMPM2T-1 TECHNICAL DATA
Rio Rancho, NM, USA
www.lectrosonics.com
Installing One M2T into a Single Rack
The M2T transmitter occupies a half rack space. This
kit provides the hardware needed to mount one M2T or
DSQD into a single rack space.
NOTE: Steps 1-6 will require original mounting
hardware that came with the units. Part numbers
are included in case individual items need to be
reordered.
1. Remove the Trim Cap (Part #P1330) from both
sides of the front panel of the M2T unit to be
rack mounted.
2. Remove the breakaway tabs on both sides of the
Chassis Cover Panel. This requires the use of a
flat-blade screwdriver inserted into the slots and
levering the tabs away on each side of the unit.
3. Insert the Flange Bracket (Part #27076) into the
open slot in the left-front side of the Chassis
Cover Panel.
4. Insert two (2) Cap Screws (Part #28885) through
the Rack Handle (Part #27082) holes and install
the Rack Handle onto the Flange Bracket through
the holes in the unit’s front panel. Firmly tighten
the Cap Screws using the long leg of the Hex
Wrench as shown.
5. Unless also installing a Front Mounted Antenna,
insert the Hole Plug (Part #35959) into the open
antenna hole in the Flange Bracket by aligning the
flat sides of the plug with those of the bracket hole
and pushing into place until flush.
6. Install the Front Tie Bracket (Part #25991) into
the open slot in the right side of the M2T Chassis
Cover Panel with the protruding nuts facing rear-
ward, affix with two (2) Cap Screws (Part #28885)
provided and firmly tighten with the Hex Wrench.
See next page.
NOTE: Steps 7-11 require parts from the
(RMPM2T-1) M2T Single Rack Mount Kit.
Single Rack Mount Kit for M2T and DSQD
Front Tie Bracket (not shown;
located behind faceplate)
Rack Flange
Bracket
(Part # 27076) Cap Screws (Part #28885)
Hole Plug
(Part #35959)
STEPS 6 and 7
STEP 9
(front)
STEP 10
(front)
Cap Screw (Part #28885)
Rack Handle (Part #27082)
7. Use two (2) Cap Screws (Part #28885) to attach
the left side of the Front Fill Panel (Part #27081)
to the two remaining nuts on the Front Tie Bracket
(Part #25991) and firmly tighten with the
Hex Wrench.
8. Use the Hex Wrench to remove the two (2) inboard
Cap Screws from the rear of the M2T. Install the
Support Bracket (Part #27077) to the rear panel of
the M2T, reusing the two (2) Cap Screws previous-
ly removed and firmly tighten with the Hex Wrench.
(See rear view image above.)
9. Insert two (2) Cap Screws (Part #28885) through
Rack Handle (Part #27082) holes and install the
Rack Handle onto the right side Front Fill Panel
(Part #27081) through the holes in the panel,
M2T Front View
and into the nuts on the Support Bracket (Part
#27076). Firmly tighten the Cap Screws
using the long leg of the Hex Wrench. (See rear
and front view images on front page.)
10. Unless also installing a Front Mounted Antenna,
insert the Hole Plug (Part #35959) into the open
antenna hole in the Front Fill Panel (Part #27081)
by aligning the flat sides of the plug with those of
the bracket hole and pushing into place until flush.
The M2T with Front Fill Panel is now ready for
installation into a rack.
NOTE: If supplied rubber foot/feet are installed
on under side of the M2T, it will not fit in a single
rack space.
M2T Rear View
Cap Screws
(Part #28885)
Support Bracket
(Part #27077) STEP 8
STEP 9
(rear)
STEP 10
(rear)
Front Tie Bracket
(Part #25991)
Rack Handle
(Part #27082)
Front Fill Panel
(Part #27081)
Items Included in RMPM2T-1 Kit:
• Technical Data Sheet
• (27077) Support Bracket
• (27081) Front Fill Panel
• (27082) Rack handle
• (28885) (4) SCR10 cap screw
• (35800) Hex L key wrench
• (35959) Hole plug
• (35664) (4) Rubber feet
• (28951) (2) Long mounting screws*
• (28950) (2) Short spacer tubes*
NOTE: Starred (*) items are needed only when
installing a DSQD, They are not needed for M2T
installation and may be set aside.
The DSQD with Front Fill Panel is now ready for
installation into a rack.
NOTE: As with the M2T, if the supplied rubber
foot/feet are installed on under side of the DSQD,
it will not fit in a single rack space.
Installing One DSQD into a Single Rack
The process to install the DSQD is the same as for the
M2T transmitter through Step 7. The DSQD looks similar
to the M2T in the frontal view. Follow the steps for the
M2T, then resume at Step 8:
8. Use the Hex Wrench to remove the two (2) inboard
Cap Screws from the rear of the DSQD. Put them
aside and save for later use or spares; you will not
need them for this installation. Install the Support
Bracket (Part #27077) to the rear panel of the
DSQD, using the two (2) long mounting screws,
threaded with Spacer Tubes, and firmly tighten
with the Hex Wrench. See rear view image and
call-out photo above. The kit is designed to handle
the M2T and the DSQD with a shorter chassis, so
the spacers are included.
9. Insert two (2) Cap Screws (Part #28885) through
the Rack Handle (Part #27082) holes and install
the Rack Handle onto the right side Front Fill
Panel (Part #27081) through the holes in the
panel, and into the nuts on the Support Bracket
(Part #27076). Firmly tighten the Cap Screws
using the long leg of the Hex Wrench.
10. Unless also installing a Front Mounted Antenna,
insert the Hole Plug (Part #35959) into the open
antenna hole in the Front Fill Panel (Part #27081)
by aligning the flat sides of the plug with those of
the bracket hole and pushing into place until flush.
DSQD Rear View
Long Screws
(Part #28951)
Support Bracket
(Part #27077)
STEP 8
STEP 9
(rear)
STEP 10
(rear)
Front Tie Bracket
(Part #25991)
Rack Handle
(Part #27082)
Front Fill Panel
(Part #27081)
Spacer Tubes
(Part #28950)
Rio Rancho, NM, USA
www.lectrosonics.com
29 May 2020
581 Laser Road NE • Rio Rancho, NM 87124 USA • www.lectrosonics.com
(505) 892-4501 • (800) 821-1121 • fax (505) 892-6243 • [email protected]
m
Mounting M2T To DSQD
When mounting two M2Ts or two DSQDs together, the units lie flush together as shown. This is not the case with an
M2T and a DSQD, as the DSQD housing is shorter and the spacer tubes are needed.
Recommended DSQD-M2T mounting
When attaching an M2T to a DSQD unit, the preferred configuration (when viewing from the back side) is to have the
DSQD to the left and the M2T to the right. If the units are mounted the opposite way, the mounting plate will partially
block the Dante®ports on the DSQD, making it difficult to remove the cables. Having the DSQD on the left as shown
below eliminates this inconvenience.
Two DSQD units
Two M2T units

Popular Rack & Stand manuals by other brands

Toro Titan 140-5125 installation instructions

Toro

Toro Titan 140-5125 installation instructions

Valcom VIP-903 quick start guide

Valcom

Valcom VIP-903 quick start guide

comfortel D-Mount Assembly instructions

comfortel

comfortel D-Mount Assembly instructions

Novus NV-5000EST-H4 user manual

Novus

Novus NV-5000EST-H4 user manual

Innovation First RETAIL-AIO-017 installation instructions

Innovation First

Innovation First RETAIL-AIO-017 installation instructions

Symphony SYK-1049 Setup instructions

Symphony

Symphony SYK-1049 Setup instructions

MrCool MB176 installation manual

MrCool

MrCool MB176 installation manual

Hama 00118610 operating instructions

Hama

Hama 00118610 operating instructions

Novopro SMS50R instruction manual

Novopro

Novopro SMS50R instruction manual

CHIEF MSP-WLB Series installation instructions

CHIEF

CHIEF MSP-WLB Series installation instructions

Ergotron StyleView 5 Assembly instructions

Ergotron

Ergotron StyleView 5 Assembly instructions

peerless-AV DS-C555-4X3 user manual

peerless-AV

peerless-AV DS-C555-4X3 user manual

Keysight EDU190A operating instructions

Keysight

Keysight EDU190A operating instructions

Goobay WH Basic Fullmotion L user manual

Goobay

Goobay WH Basic Fullmotion L user manual

Thule 300R quick start guide

Thule

Thule 300R quick start guide

HAUL MASTER 66260 Instructions and precautions

HAUL MASTER

HAUL MASTER 66260 Instructions and precautions

Sealey AS6.V2 Series quick start guide

Sealey

Sealey AS6.V2 Series quick start guide

Commercial Electric MB-50900 Use and care guide

Commercial Electric

Commercial Electric MB-50900 Use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.