Legendairy Milk DUETTE User manual

DUAL ELECTRIC BREAST PUMP
Manufactured for Legendairy Milk, LLC www.legendairymilk.com
™


ta b l e o f c o n t e n t s
Welcome 2
Indications for Use 2
Important Safety Information 3
Parts Guide 4
Important Information Regarding Your FluidFit®Collection Kit 6
How to Assemble the FluidFit®Collection Kit 7
Connecting FluidFit®Collection Kit and Pump Kit 8
Pumping Instructions 8
Getting Started 10
Using Customizable Pumping Styles 10
Cleaning and Sterilizing Instructions for Your FluidFit®Kit 12
Troubleshooting 14
Technical Data 16
Warranty 16

2
welcome t o t h e l e g e n d a i r y m i l k®fa m i ly !
Thank you for choosing the Duette™ Dual Powered Electric Breast Pump.
Legendairy Milk® is pleased to offer the rst dual breast pump with completely
independent suction and speed settings for the left and right breast! This provides a
customized and individualized pumping experience for maximum comfort and
breastmilk output. With the Duette™, your pumping possibilities are now endless!
indications f o r u s e
The Duette™Dual Powered Electric Breast Pump is an electrically powered suction
device intended to express and collect milk from a lactating person’s breasts.
This pump is intended for a single user.

3
i m p o r ta n t s a f e t y information
• When using any electrical products, basic safety precautions
should always be followed.
• Read all instructions before using.
• This product is intended for personal use and for one user only.
Danger — to reduce the risk of electrocution
• Do not use while bathing, showering or swimming.
• Do not reach for a product if it has fallen into water.
Immediately unplug from electrical outlet.
• Do not place or drop into water or other liquid.
• Do not spray or pour liquid directly on to the pump.
• Do not place or store this product where it can fall or be
pulled into a sink or tub.
To reduce the risk of burns, electrocution, re or injury to person
• Never use while sleeping or when drowsy.
• Do not drop or insert any object into any opening of the pump unit.
• Do not use this product if it is broken or any parts are missing.
• Close supervision is necessary when this product is used near children.
• Never operate this product if it has a damaged cord or plug,
if it is not working properly, if it has been dropped or damaged,
dropped into water, or if any parts are broken or missing.
• Make sure all parts are assembled correctly before pumping.
• This product should never be left unattended when plugged in.
• Keep the cord away from heated surfaces.
• Always unplug electrical product immediately after use.
• Use this product only for its intended use as described in this manual.
• Do not allow small children or pets to play with the pump unit, AC adapter, etc.
• Do not operate where aerosol spray products are being used or where oxygen is
being administered.

4
p a r t s guide
Bottle Kit
Silicone Lid
Nipple Collar
Wide Neck
PPSU Bottle
Caution:
If pumping is uncomfortable or causing pain, turn the unit off, break
the seal between the breast and breast shield with your nger and remove
the breast shield from your breast. If irritation or discomfort occurs,
discontinue use and consult your lactation consultant.
SAVE THIS INSTRUCTION MANUAL
Continued from page 3

5
01 02 03 04 05 06 07
08
09
10
11
12
13
14
15
16
09. Pump Unit
10. Bottle Stand (2)
11. 4oz Wide-neck Bottle (2)
12. Nipple (2)
13. Nipple Collar (2)
14. Bottle Cap/Cover (2)
15. Silicone Lid (2)
16. Bottle Adapter - Wide Neck to
Narrow Neck (2)
01. Shield Cap (2)
02. Liquid Silicone Cushion with
Integrated Duckbill Valve (2)
03. Breast Shield (2)
04. Silicone Diaphragm (2)
05. Cap (2)
06. Tubing Connector (4)
07. Power Adapter
08. Tubing (2)
No parts of this device were made with BPA

6
i m p o r ta n t information regarding
y o u r fluidfit®c o l l e c t i o n k i t
• Wash your hands with soap and water and dry thoroughly
before assembling parts.
• Ensure all parts are clean and dry before each use.
• Avoid harsh detergents as this may damage the product.
• Exposure to detergent may make the silicone appear
cloudy over time.
• Store in a cool, dry space and avoid direct sunlight.
• Replace the parts or the product if it shows signs of
wear or damage.
• Replace the silicone cushion every 1-2 months or more
often depending on frequency of use.
• Please do not use a cleaning brush inside the valve of
the silicone cushion as this may damage the valve or
shorten its lifespan.
• This product is a personal care item, and use should not
be shared between mothers.
• This product is only intended for use with compatible pumps.
• If you are experiencing any pain while using this product,
seek professional advice from a lactation consultant to
ensure you have a correctly-tted breast shield.
• Contains small parts which may be a choking hazard
for children.

7
h o w t o a s s e m b l e
1. Assembling the breast shield kit:
Insert the soft silicone cushion into
the breast shield. Ensure the valve is
securely attached to the bottom of
the breast shield.
2. Assembling the diaphragm:
Press the silicone diaphragm down with
your ngers so it’s ush with the top of
the breast shield. Place the white cap on
with the hole for the tubing insert posi-
tioned slightly to the right. Twist the cap
to the left until it’s tightly in place.
3. Assembling the bottle and base:
Twist the bottle on and insert the tubing
into the white cap.

8
connecting fluidfit®c o l l e c t i o n k i t a n d p u m p k i t
Insert one tubing connector (shown in the diagram below) into each of the air vents
on the diaphragm cap. Insert the other side of the tubing connector into the pump
unit. Please reduce the suction if you feel any discomfort.
tubing connectors
p u m p i n s t r u c t i o n s
Control Panel
Speed Level Suction Level
Memory
Function
Speed
Mute Button
Press + and –
at the same time to
activate mute button
function. Press again
to deactivate
Child-Lock Button
Press + and –
at the same time to
activate child lock
function. Press again
to deactivate
Speed
Side Selection:
Left, Right, Duette ON/OFF
Pause / Resume
Phase:
Stimulation / Expression /
Rapid / Auto Loop
Child-lock Mute Button
Memory Function Battery

9
Record Your Own Program
Long press the Memory Function button to record the pumping session.
Adjust the suction and speed settings to your liking. Press and hold again to
save the recording. To access the recording, short press the Memory Funtion
button. Press it again to exit the recording.
Child Lock:
To activate the child-lock function, press the + and – at the same time.
The lock icon will display on the screen. Press again to deactivate.
Mute Button
This function activates when you press the + and – at the same time.
The mute icon will display on the screen. Press again to deactivate.

10
g e t t i n g s ta r t e d
1. Fully charge device before use.
2. Attach the FluidFit collection kit to your breasts so that the nipple is
centered and aligned straight toward the silicone cushion of the
breast shield.
3. Make sure your breast completely lls the breast shield so that
a vacuum is formed and no air escapes.
4. Press and hold the on/off button to turn the pump on.
Your Duette Breast Pump will always start in the let-down (stimulation phase).
Note: When you turn the pump on for the very rst time, it starts in
stimulation phase, suction level 1.
5. Press Side Selection button to select the pump to operate on the
Left, Right, or Duette Mode. Suction and Speed settings can be adjusted sepa-
rately for the left or right side.
6. Press Phase button to toggle between the four unique pumping styles.
using c u s t o m i z a b l e pumping s t y l e s
The Duette™Dual Electric Breast Pump offers 4 unique pumping styles so you can
nd the settings that are most comfortable and effective for you.
• Stimulation Phase: 9 levels of suction control, 3 levels of speed control
• Expression Phase: 9 levels of suction control, 3 levels of speed control
• Rapid Phase: Alternating 5 cycles of Simulation Phase and
5 cycles of Expression Phase
• Auto Loop: Alternating 3 minutes of Stimulation Phase and 7 minutes of
Expression Phase

11
Your pump has 3 speed settings that vary based on if you are in stimulation phase or
expression phase. To adjust the cycle speed, press the speed level button anytime
after you turn on the pump.
Your speed settings can be different on both sides (left and right) during pump
sessions and can be set independently.
Your pump’s vacuum (suction) strength has 9 levels in both stimulation and
expression phases and are independently adjustable on each side. To adjust the
suction level, press the +/- buttons.
Speed Settings:
Stimulation Phase
Vacuum Strength: 1-9
Cycle Speed: 80-100 cycles / min
Expression Phase
Vacuum Strength: 1-9
Cycle Speed: 20-60 cycles / min
Press the pause/resume button to pause pumping and then resume again.
Note:
The Duette is designed to turn off automatically after 30 minutes.

12
cleaning a n d sterilizing i n s t r u c t i o n s f o r
y o u r fluidfit®®k i t
?
Before rst use
• Disassemble all parts.
• Wash in warm soapy water (except for tubing).
• Rinse well with clean water.
• Submerge parts in pot of water (except for tubing) and boil for 3-5 minutes.
Use large pot to prevent parts from touching sides or bottom of pot.
• Shake off excess water and air-dry on a dedicated rack or clean cloth.

13
After each use
• Put aside parts that don’t come in contact with breastmilk.
When used correctly, tubing does not come in contact with breastmilk
and does not need to be cleaned.
• Disassemble all other parts (silicone cushion, silicone diaphragm, cap and bottle).
• Rinse with cold water soon after use.
• Wash in warm soapy water.
The silicone cushion can be cleaned by gently rubbing between ngers.
• Rinse well.
• Shake off excess water and air-dry on a dedicated rack or clean cloth.
How to sanitize
• Follow cleaning instructions from the above section.
• Submerge parts in pot of water and boil for 3-5 minutes.
Use large pot to prevent parts from touching sides or bottom of pot.
• Shake off excess water and air-dry on a dedicated rack or clean cloth.
After rst sanitizing all parts (except tubing), please do not boil
silicone parts again. Do not steam, sterilize, or dish wash silicone parts.
For longer lifespan of your silicone parts, hand wash only after rst
use. UV sterilization or cold sterilization is acceptable, as well.

14
troubleshooting
Issue
Low or no suction
Condensation
or milk in tubing
Solution
Ensure tubing is rmly inserted into the white cap.
Double check that the valve in the silicone cushion is ush
with the breast shield and assess for any damage or wear.
Replace silicone cushion if needed.
Make sure all parts are dry and securely attached.
Ensure that the silicone cushion forms a tight seal around
the breast.
Ensure the silicone diaphragm and white cap are rmly
attached to the top of the breast shield. Place the white cap
on with the hold for the tubing insert positioned slightly to
the right. Twist the cap to the left until it’s tightly in place.
Ensure that the tubing, silicone diaphragm and white cap
are dry before use.
If condensation occurs, ensure tubing is dry before next use.
To do this, disconnect tubing from breast shields and turn the
pump back on to dry the tubing while you are storing away
your breast milk.
Check the valves in the silicone cushion and the silicone dia-
phragm for damage. Replace if needed.
Do not sterilize tubing in the dishwasher, steam sterilizer
or by boiling.

15
Issue
E1/E2 on the screen
and alarm ring
E3 on screen and
alarm ring
Solution
This sound means that there is a short circuit in either E1 or
E2. Send the pump back to the dealer for repair.
Check to see if the pump is over or below the optimal
working temperature: from 40*F/ 5*C to 140*F/ 60*C.
Place the machine in an optimal place to allow it to cool
or warm as needed.

16
technical d at a
Model: Duette™Dual Electric Powered Breast Pump
AC adapter: input 100-240V~ 50/60Hz, output 5V /2A
Total power: 10W
Battery: Li–ion polymer battery: 3.7V 3600mAh
Stimulation Speed: 80–100 cycles / min, (3 levels)
Stimulation Vacuum: -0.003 ~ –0.018MPa (9 levels vacuum)
Expression Speed : 20 ~ 60 cycles / min
Expression Vacuum: –0.013 ~ –0.036MPa (9 levels vacuum)
Timer: 30 minutes
DC hole: type C
Overall noise: <60dB(A)
Operating Conditions: 5~40*C , 40~140* F, Rh<90%
Electric shock protection: AC adapter Class II, host machine Class III
Product standard: QB/T5136–2017
w a r r a n t y
This is a single user product. Use by more than one person may present a health
risk and void the warranty. There is a 1-year warranty for the unit from the date
of purchase, excluding the FluidFit kit. Proof of purchase in the form of a receipted
invoice or bill of sale evidencing that the product is within the warranty period must
be presented to obtain warranty service. For warranty service, contact
[email protected]om. Warranty coverage terminates if you sell or otherwise
transfer this product to another person or improperly or incorrectly perform any
maintenance or repair of this product.
Table of contents