LIFTPRO LPO0600 Wiring diagram

Installation Instructions
& User Guide
Please read the manual carefully before installation and use.
The installation of your new door operator must be carried out
by a qualied or licensed person.
Attempting to install or repair the door operator without suitable
technical qualication may result in severe personal injury,
death and / or property damage.
WARNING
7625C
0, 93, 95, 2
White
0, 0, 0, 0
7625C
0, 93, 95, 2
425C
48, 29, 26, 76
0, 0, 0, 90
0, 0, 0, 60
LPO0600 600N
LPO1000 1000N
LPO1200 1200N
S/N

CONTENTS
Important Safety Recommendations
Product Description & Features
Pre-Installation Recommendations
Installation (Wall Bracket & Door Bracket)
Installation (Steel Track)
Installation (Sectional Steel Track Assembly)
Battery Backup Assembly (optional)
Display Menu Instructions
Programming Instructions
Terminal Introduction and Application
Manual Disengagement
Maintenance
Technical Specications
Parts Listing
Common Faults & Solutions
3
4-5
6
6
7
8
9
10
11-22
22-23
24
24
25
26
27-28
2

IMPORTANT SAFETY RECOMMENDATIONS
FAILURE TO COMPLY WITH THE FOLLOWING SAFETY RECOMMENDATIONS MAY RESULT IN
SERIOUS PERSONAL INJURY, DEATH AND/OR PROPERTY DAMAGE.
1. Please read carefully and adhere to all safety and installation recommendations.
2. The operator is designed and manufactured to meet local regulations. The installer must be familiar
with local regulations required in respect of the installation of the operator.
3. Unqualied personnel or people who do not understand health and safety standards being
applicable to automatic gates and other doors, must in no circumstances carry out installations or
implement systems.
4. Those who install or service the equipment without observing all the applicable safety standards
will be responsible for any damage, injury, cost, expense or claim whatsoever any person suered as
a result of failure to install the system correctly and in accordance with the relevant safety standards
and installation manual if directly or indirectly.
5. For additional safety we strongly recommend the inclusion of Photo Beam. Although the operator
incorporates a pressure sensitive Safety Obstruction Force system, the addition of Photo Beam will
greatly enhance the operating safety of an automatic garage door and provide additional peace of
mind.
6. Make sure that the garage door is fully open & stationary before driving in or out of the garage.
7. Make sure the garage door is fully closed & stationary before leaving.
8. Keep hands and loose clothing o the operator and garage door all the time.
9. The Safety Obstruction System is designed to work on STATIONARY objects only.
Serious personal injury, death and / or property damage may occur if the garage door comes into
contact with a moving object.
10. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
11. Waste electrical products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your local authority or retailer for recycling advice.
12. If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or
qualied person.
WARNING: Important safety instructions.
For safety, all users and installers must follow all instructions. Save these instructions.
- Do not allow children to play with door controls. Keep remote controls away from children.
- Watch the moving door and keep people away until the door is completely opened or closed.
- Take care when operating the manual release since an open door may fall rapidly due to weak or
broken springs, or being out of balance.
- Frequently examine the installation, in particular check cables, springs and mountings for signs
of wear, damage or imbalance. Do not use if repair or adjustment is needed since a fault in the
installation or an incorrectly balanced door may cause injury.
- Each month check that the drive reverses when the door contacts a 50 mm high object placed on the
oor. Adjust if necessary and recheck. Incorrect adjustment may present a hazard.
- Details on how to use the manual release.
- Information concerning the adjustment of the door and drive.
- Disconnect the power supply when cleaning or carrying out other maintenance.
- The installation instructions shall include details for the installation of the drive and its associated
components.
3

1. Obstruction force adjustment
The minimum force display “1” and it can be adjusted upward. Display “5” means the maximum force.
2. Travel speed adjustment
“8” appears on the display indicates the 80% of the travel speed. Display “A” means the full speed
160mm/s or 200mm/s.
3. Reversal height adjustment
“0” appears on the display indicates the door will return to the top. Display “1~9” indicates the door will
rebound to the position of the whole travel. One tenth to Nine tenth of the whole travel etc.
4. Partial open/height
“0” appears on the display indicates close the partial open function. Display “1~9” to set the dierent
partial open position of the whole travel.
5. Transmitter button recognition function
“0” appears on the display indicates the buttons recognition function is closed. Display “1” indicates the
button recognition function is open.
6. Codes memory quantity
“A” appears on the display indicates the maximum code memory quantity (50pcs). Press UP/DOWN
button once, to increase or decrease quantity. The code memory quantity is set on 5pcs*N, N=1~9.
(The quantity is the multiple of 5).
7. Maintenance alarm
“b” appears on the display and led light ashes 10 times quickly means the garage door and motor
requie maintenance.
8. Automatic safety reverse
Automatic stop / automatic reverse are controlled by the internal circuit boards.
9. Soft start / Soft stop
Ramping speed up and down at the start and end of each cycle reduces stress on the door and
operator for a longer service life, and ensures quieter operation.
10. Auto-Close
Auto-Close ensures peace of mind and keeps your house secure by automatically closing the door
upon entering or exiting the garage.
11. Self learning open and close obstruction force
The amount of operator power for dierent stages of the door’s travel is learnt during setup and is
constantly re-proled. The force measurement automatically adjustment in a suitable range.
12. Electronic limit, simple adjustment.
Limit setup can be adjusted from the control panel.
13. Extra terminal positions
Terminals available for accessories such as photo beams, additional receivers, wired or wireless wall
switches, caution lights & wicket door protection devices.
14. Energy saving - LED courtesy light
3 minutes LED light delay, switching on with each cycle to illuminate your darkened garage.
15. Battery backup (optional)
Operators can be supplied with optional battery backup, allowing limited use during power failure.
16. Self-Locking gear motors
Gear motor will self-lock when power is disengaged.
17. Manual release
The manual release system can be used to operate the door at any time.
PRODUCT DESCRIPTION & FEATURES
4

18. Transmitter technology
Rolling Code technology (7.38 x 1019 Combinations), 433.92 MHz frequency, 4 channels design to
allow control of 4 dierent doors with one transmitter.
19. Applications
With as little as 30mm required between the ceiling and the highest point of the door travel, the
operator can be ush mounted for low headroom applications.
20. Metal bottom plate, for additional strength and security.
21. Up / Down (Open/Close), operation buttons (UP / DOWN)
Open
Close
5

PRE-INSTALLATION RECOMMENDATIONS
INSTALLATION INSTRUCTIONS
1. The garage door should be lifted and closed easily by hand and without much eort. A well
balanced & sprung door is critical for proper installation.
2. The garage door operator can’t compensate for a badly installed garage door and should not be
used as a solution for a “hard to open” door.
3. If the unit is being installed on an existing door, make sure any existing locking devices are removed
or warranty will be void.
4. An approved electrical outlet must be installed close to the operator installation point.
5. There should be a minimum gap of 30mm between the bottom of the chain drive rail and the top of
the garage door at its closest point. (refer to Fig 1.)
Important note: For additional safety, it is strongly recommended that a Photo Electric safety beam is
tted on all installations.
Wall Bracket - Close the garage door and measure the garage
door width at the top and mark the centre. Locate and mount
the wall bracket 2cm-15cm above the door on the inside wall.
(Depending on the actual installation space).
Door Bracket – Fix the door bracket to a structural part of the door
as close to the top edge as possible.
30mm Minimum Clearance
Figure 1
Figure 2
Mount Wall Bracket and Door Bracket (Fig.2)
6

Figure 3
Figure 5
STEP 1 (Fig.3)
Attach the operator head to the steel track.
Assembly the 2 “U” Hanging brackets with 6mm nuts supplied.
STEP 2 (Fig.3)
Place the steel track and operator head assembly centrally on the garage oor, with the open head
furthest away from the door. Lift the front of the track up to the door bracket. Insert the pivot pin and
secure it with the split pin supplied.
STEP 4 (Fig.3, Fig.5)
Connect the straight arm to the bent arm with the bolt.
Position and bolt the arms to the top edge of the door using the bolt supplied.
STEP 5
Lift the garage door until the shuttle locks into the drive chain/belt.
The operator can now be programmed.
STEP 3 (Fig.3, Fig.4)
Lift and support the operator head (with a ladder) so it is positioned centrally and
level. Fix the operator and track on the ceiling using the supplied support brackets.
WARNING: Do not allow children around the door, operator or supporting ladder
serious injury and/or damage may result from failure to follow this warning.
Figure 4
Installation (Steel Track)
7

Sectional Steel Track Assembly
A: 1500mm
C: 1000mm
Sleeve
Sleeve Sleeve
B: 1500mm
E: 1000mm
D: 1000mm
2 Part Steel Track
3 Part Steel Track
Figure 6
Figure 7
1.
2-Parts Track:
As Fig.6, slide the A rail into the sleeve, slide the B rail into the sleeve.
3-Parts Track:
As Fig.7, slide the C rail into the sleeve, slide the D rail into the sleeve; slide the E rail into the sleeve.
2. Cut the plastic thread; pull the screw rod along with inner chain to the end rail position (Fig.8)
1. As Fig.9, release the nut & spring.
2. Tighten the nut in the correct position as shown in Fig.10. Cut the plastic tape and the plastic thread
on sprocket. Rail assembly is now complete.
Figure 8
Figure 9 Figure 10
8

Battery Backup Assembly (optional)
Option 1 - Top Fixed(For Lead-acid Battery only)
Option 2 - Side Fixed (For Lead-acid & Lithium Battery)
STEP 1 (Fig.11)
Assemble the battery & the bracket as shown, using the screws supplied.
STEP 2 (Fig.12)
Connect the battery to the operator.
STEP 1 (Fig.13)
Assemble the battery to the side of the operator, using the screws supplied.
STEP 2 (Fig.14)
Connect the battery to the operator.
Figure 11
Figure 13
Figure 12
Figure 14
9

DISPLAY MENU INSTRUCTIONS
Features Settings
a) Press and hold SET button until “1” appears on the display then
release the button.
b) Press UP / Down button, to display “1-E” .
c) Press SET button to conrm the function you need to set, The
system will then enter the interface to set the function.
d) In the function settings, the interface will display “0-A” with a
ashing dot.
e) Press UP / Down button to choose the feature you need to set.
f) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
10

PROGRAMMING INSTRUCTIONS
Pre- Instruction for programing controller buttons
1. Short press SET button : When in standby, this will clear the error, alarm display, and return to
normal display.
2. Short press CODE button :
(In the Setting Status) Exit the current operation and return to the standby interface.
When in standby, press the CODE button, A dot will be displayed in the corner.
The system is now entering the code learning mode.
Click the button of the hand transmitter you want to use, the dot may disappear ,then press the same
button again, the dot will ash and the code learning has nished.
3. Short press UP button : The door will open.
4. Short press DOWN button : The door will close.
(When the door is opening or closing, it will stop if you press any key.)
5. Long press SET button : Enter function setting interface.
6. Long press CODE button : Press and hold CODE button until a C is indicated on the display.
All stored remotes will be deleted.
7. Long press UP button : Increase the resilience. (Keep pressing DOWN button, after 4 seconds, it will
scroll to display 0-1-2, choose the number you want. 1=increase 25% 2=increase 50%)
8. Long press DOWN button : Restore Factory Settings
Keep press DOWN button, after 4 seconds, it will scroll to display , then the garage door
operator will restart.
Restarting the unit will reset all settings back to factory settings, all coding needs to be completed
again, except the transmitter code learning.
11

PROGRAMMING INSTRUCTIONS
1. Programming Open & Close Limits
a) Press and hold SET button to enter this function setting until “1”
appears on the display then release the button.
b) Press the SET button again. The door operator is now in
Programming Mode. You will then see “n” with a dot appears on the
display.
c) Press and hold the UP button until the door reaches the desired
open position, you will see “n” without dot on the display.
d) Press SET button to conrm the open position, then you will see
“u” with dot on the display.
e) Next press and hold the DOWN button until the door reaches the
desired close position, you will see “u” without dot on the display.
NOTE: For ne adjustments toggle UP & DOWN buttons.
f) Now press the SET button to conrm the close position, then you
will see “II” on the display.
After conrm the close position, the door will now cycle open and
close to set the travel limits and force sensitivity adjustments. The
door is now set for normal operation.
CAUTION: After the open and close cycle, there will be gures
shown on the display (0~9), “0” indicates the doors is balanced,
the smaller the gure, the better the door balance.
It is strongly recommend that this gure is smaller than the
power force.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
12

2. Obstruction Force Adjustment
CAUTION:
The obstruction force adjustment is set automatically during
programming. Normally no adjustment is necessary.
a) Press and hold SET Button until “1”appears on the display, next
press the UP Button until “2” appears on the display to enter this
function setting then release the button.
b) Press the SET button again, The unit is now in force adjustment
mode. You will see a gure “3” with a ashing dot on the display.
c) Press the UP button to increase the force setting or the DOWN
button to decrease the force setting.
The minimum force is “1” and it can be adjusted upward. The
maximum force is “5”.
d) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The force is set on “3” as default.
3. Travel Speed Setting
CAUTION: If you changed the speed again, it will cancel the
previous travel limit. The speed adjustment function will be
available only after you reset the travel limit.
a) Press and hold SET Button until “1”appears on the display, next
press the UP button until “3” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in speed adjustment
mode. You will see a letter “A” and a ashing dot on the display.
c) Press the UP & DOWN button to choose the speed. Figure “8”
means the 80% of the travel speed. Figure “A” means the full speed.
d) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The travel speed is set on full speed “A” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
increase force
increase speed
decrease force
decrease speed
SET UP
CODE DOWN
SET UP
CODE DOWN
13

4. Automatic Closing & Time Setting
NOTE: We recommend that Safety Photo Beams are used in any
installation where the Auto Close function is enabled.
a) Press and hold SET Button until “1”appears on the display, next
press the UP button until “4” appears on the display to enter this
function setting then release the button.
b) Press the SET button again, the unit is now in automatic close
adjustment mode. You will see a gure “0” with a ashing dot on the
display.
c) Press UP / Down button once to set the auto close time (0~9).
d) Press UP button to increase the time, or DOWN button to
decrease the time.
The close time is 15second*N, N=0~9.
The maximum time is 135s. To disable Auto Close Function, set
time to zero (0).
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE:
1.The closing time is set on “0” as standard.
2. If the Photo Cell Function is on, and the light beam is broken by
the obstruction, the auto close time will stop for a while, and then
continue the automatic close time again.
SET UP
CODE DOWN
SET UP
CODE DOWN
increase time
decrease time
SET UP
CODE DOWN
SET UP
CODE DOWN
14

5. Automatic Closing Condition Setting
a) Press and hold SET button until “1” appears on the display, next
press the UP button until “5” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in automatic close
adjustment mode. You will see a gure “1” with a ashing dot on the
display.
c) Press UP / Down button once to set the auto close mode.
You can choose “1” or “2”.
Figure “1”:
The door only can auto close while in the open limit position.
Figure “2”:
The door can auto close while the door is in any position.
d) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTES: 1. The closing mode is set on “1” as default. | 2. The door will automatically close when
stopped in its opening process, but can’t automatically close when it is stopped in its closing process.
6. LED OFF Delay Time Setting
a) Press and hold SET button until “1” appears on the display, next
press the UP button until “6” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in LED o delay time
adjustment mode. You will see a gure “3” with a ashing dot on the
display.
c) Press UP / Down button once to set the LED o delay time (1~9).
d) Press UP button to increase the time, or DOWN button to
decrease the time.
The delay time is 1 minute*N, N=1~9.
The maximum delay time is 9 minutes.
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The LED o delay time is set on “3” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
increase
increase time
decrease
decrease time
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
15

7. Reversal Height Setting
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “7” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in reversal height
adjustment mode. You will see a gure “0” with a ashing dot on the
display.
c) Press UP / Down button once to set the reversal height while
closing (0~9).
d) Press UP button to increase , or DOWN button to decrease.
Figure “0” : The door will return to the open limit position.
Figure “1~9” : The door will rebound to the position of the whole
travel. One tenth to Nine tenths of the whole travel etc...
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The reversal height is set on “0” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
increase height
decrease height
SET UP
CODE DOWN
16

8. Partial Open/Height Setting
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “8” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in partial-open/height
adjustment mode. You will see a gure “0” with a ashing dot on the
display.
c) Press UP / Down button once to select if you want to open the
partial open function or set the partial open height. (0~9).
Press UP button to increase , or DOWN button to decrease.
Figure “0” : Close the partial open function.
Figure “1~9”: Set the partial open position of the whole travel.
One tenth to Nine tenths of the whole travel etc...
d) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTES:
1. The partial open/height is set on “0” as default.
2. If you use the partial open/height function, the buttons’ recognition function will be disabled.
3. Other details please refer to the Instruction manual of the remote carefully.
4. If you enabled the partial open function then disabled this function later, please note that only the
coded button you have programmed can control the operator.
SET UP
CODE DOWN
SET UP
CODE DOWN
increase
decrease
SET UP
CODE DOWN
SET UP
CODE DOWN
17

9. Transmitter Buttons Recognition Setting
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “9” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in button recognition
function adjustment mode. You will see a gure “1” with a ashing
dot on the display.
c) Press UP / Down button once to select if you want all the 4
buttons to control one operator, or a separate coded button can
control the operator.
Figure “0”: The button recognition function is closed. It means
if you coded 1 button with 1 operator, then all the 4 buttons on the
remote can control the operator. This is suitable for users who only
have 1 automatic door at home.
Figure “1”: The button recognition function is open. If you coded
the rst button with rst operator, then the rst button will be the
only button on the remote that can control the operator. Suitable
for users who have more than 1 automation doors/gates at home.
d) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTES:
1. The buttons recognition is set on “1” as default.
2. After coding the hand sets, only the coded button can control the
operator.
A. Codes Memory Quantity Setting
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “A” appears on the display to enter this
function setting then release the button.
b) Press the SET button again, the unit is now in remote quantity
adjustment mode. You will see a gure “A” again, but with a ashing
dot on the display.
c) Press UP / Down button once to set the remote quantity.
(A or 1~9).
d) Figure “A”means the maximum quantity 50pcs. Press UP/DOWN
button once to increase or decrease quantity.
The remote quantity is set on 5pcs*N, N=1~9. (The quantity is
the multiple of 5)
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The remote quantity is set on “A” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
increase Qty
decrease Qty
18

B. Low Level Obstruction Override
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “b” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in reversal height
ignorance adjustment mode. You will see a gure “1” with a ashing
dot on the display.
c) Press UP / Down button once to set the reversal height ignorance
while closing (0~9).
d) Press UP button to increase , or DOWN button to decrease.
Figure“1~9” : The door will not return even when there are
obstacles in its closing path within 1cm~9cm away from the
close position. This function is more suitable for Northern
Europe or areas where there is regular snow on the ground.
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The reversal height is set on “1” as default.
C. Wicket/Pass Door Switch Type Setting
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “C” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in the pass door
switch type adjustment mode. You will see a gure “0” with a
ashing dot on the display.
c) Press UP / Down button once to set the pass door switch type.
You can choose “0” or “1” set.
Figure “0”: The wicket door function is normally open.
Figure “1”: The wicket door function is normally close.
e) Press SET button to conrm the settings and it will return to
standby status automatically and display “ll”.
NOTE: The pass door switch is set on “0” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
increase height
decrease height
SET UP
CODE DOWN
SET UP
CODE DOWN
19

D. Photo Cell ON/OFF Setting
NOTE:
Make sure the photo cell has been correctly connected to the
Normally Closed contacts on the accessory terminals of the operator.
Also note that the photo beam function must be disabled if NO
photo beams are tted, otherwise the door cannot be closed,
and the LED display will show the letter “r”.
a) Press and hold SET Button until “1” appears on the display, next
press the UP button until “d” appears on the display to enter this
function setting then release the button.
b) Press the SET button again. The unit is now in the photo cell ON/
OFF adjustment mode. You will see a gure “0” with a ashing dot on
the display.
c) Press UP / Down button once to set the photo cell ON/OFF switch.
You can choose “0” or “1”set.
Figure “0” means, the photo cell function is closed.
Figure “1” means, the photo cell function is open.
d) Press SET button to conrm the set and it will be back to standby
status automatically and display “ll”.
NOTE: The photo cell is set on “0” as default.
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
SET UP
CODE DOWN
20
This manual suits for next models
2
Table of contents
Popular Garage Door Opener manuals by other brands

Erreka
Erreka KAIROS Series Quick installation guide

Raynor
Raynor 3280RGDM owner's manual

Chamberlain
Chamberlain Smart Garage MYQ-G0401 quick start guide

Wayne-Dalton
Wayne-Dalton 9700 manual

RITE-HITE
RITE-HITE Protecdor 8000CL owner's manual

Wayne-Dalton
Wayne-Dalton 8300 Installation instructions and owner's manual