OPERATION & MAINTENANCE — To turn the fan on, flip the switch to either the
LOW or HIGH positions (LOW is recommended for most conditions). The green
indicator light on the switch will illuminate whenever the fan is running. The fan may
be left on whenever the RV/Boat is occupied, but should be shut off before putting
the RV/Boat into long-term storage. Whenever a ceiling vent fan is also used, it
should be set to draw air INTO living areas, rather than pulling air OUTWARD; this
will prevent the fans from working against each other. The DC brushess motor
requires no maintenance. However, the debris screens located inside both pipe
fittings (when present) should be cleaned every year or so. Replacement motors and
other parts are available from the factory.
WARRANTY— LSL Products warranties this product for a period of ONE YEAR from the date of purchase against defects in materials and workmanship. PLEASE SAVE
YOUR RECEIPT AS PROOF OF WARRANTY COVERAGE. This warranty is transferable. In the event a problem, LSL Products will, at its option, repair or replace any
defective components, at no charge to the owner. (The owner is responsible for the shipping charges associated with initial return of the product; LSL Products will pay the
shipping charges for returning a repaired product back to the owner). IN THE EVENT OF A PROBLEM, PLEASE CONTACT US PRIOR TO RETURNING THE PRODUCT.
This warranty does not cover damage due to unreasonable use of the product. IN NO EVENT SHALL LSL PRODUCTS NOR ANY OF ITS REPRESENTATIVES BE
RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty gives you specific legal rights, and you may have other rights which vary from state to
state. For parts & service, contact LSL Products, 5804 Babcock Rd. #512, San Antonio, TX 78240 Phone (877) 257-4655.
GENERAL INFORMATION — Lil' Stanker™ fans are designed to create a slight vacuum within your holding tanks that helps in preventing odor infiltration into living areas.
This continuous air suction is effective in controlling both grey and black water tank odors (although a separate fan is usually necessary for each holding tank.) The In-Line™
version is designed to be mounted at any point along the vent pipe's run between the holding tank and roof. Standard female pipe fittings for 1-1/2" I.D. vent pipe are used for
fan attachment; other fitting sizes are available via special order. The fan can be mounted at any angle — even upside-down if necessary. The two-speed selector switch can
be mounted either inside the included enclosure, or on your own panel. A green power indicator light on the switch confirms that the fan is turned on.
STEP 1: Determine the best mounting location
for your fan, based upon:
1.
•1. Access to the vent pipe,
•2. Access to nearby DC power wires,
•4. Best physical appearance (if mounted inside
living areas).
For example, the fan might be installed inside the same compartment that
houses the holding tank, or inside a cabinet or closet. The fan is inaudible at
any distance greater than several feet, so this is the minimum distance that it
should be mounted from sleeping areas.
Next, test the fan by temporarily connecting it directly to your house battery or
other 12 volt DC power source (GREEN wire to POSITIVE, and WHITE wire to
NEGATIVE). The fan should start immediately.
STEP 2: If not already present, install a roof-
mounted vent pipe cap, in order to keep debris and
rainwater from falling down into the fan.
Next, identify the intended fan mounting location,
and cut a 3-1/4" inch (83 MM) section out of the
vent pipe at this point (use the Vent Pipe Cutting
Gauge shown at right to measure the proper
distance). Trim away any rough edges on the pipe,
and apply either a dab of petroleum jelly or a layer
of Teflon® tape all the way around around the end
of each pipe, in order to provide an airtight seal
with the fan. Next, slide the fan in place over the
pipe ends. (NOTE: The fan should be installed so
that the AIR FLOW arrow points towards the end of
the vent pipe on the roof.)
Vent Pipe From
Holding Tank
Vent Pipe
To Roof
NOTE: Installing the fan with cement is not
recommended, since doing so would hinder any
future attempts to remove the fan for repairs or
cleaning. A slip-in fit is sufficient to provide an air-
tight connection.
CAUTION: Take care to avoid twisting the
fan while inserting the vent pipe. Excessive
force may break the fittings on the fan.
2.
Holding Tank
Deodorizer Fan
DoubleSpeed™
11-14VDC @ 0.12/ 0.25 Amps
Green: Positive White: Negative
WARNING:FILTERED DC ONLY!
USE ONLY WITH SUPPLIED SWITCH
LSL Products • San Antonio, TX
Made
In
U.S.A.
Holding Tank
Deodorizer Fan
LSL PRODUCTS • 5804 BABCOCK RD. # 512 • SAN ANTONIO, TX 78240 • (877) 257-4655 • www.LSLProducts.net
In-Line™
DoubleSpeed™
•3. Convenient nearby switch mounting location, and
3.
Green
Wire
Green
Wire
Switch (top view)
Green Terminal
Block
Next, mount the switch in the
switch enclosure (or your own
panel), securing it with one switch
nut. Use the two mounting
screws to attach the enclosure (if
used) to a flat mounting surface,
after routing all wires out the
small slot on the side.
of the green terminal block on the
switch as shown below, and tighten
each of the 3 screws on the top of the
terminal block with a small screwdriver.
Note that both WHITE wires go to the
same CENTER hole in the terminal
block.
Mounting
Screw
STEP 3: Select a convenient, non-metallic mounting
surface for the fan shutoff switch inside a closet,
cabinet or other compartment, near the fan's power
wires. (NOTE: If desired, up to 2 fans may be
connected to the same switch). Cut the fan’s wires
next to this mounting location. Strip approx. 1/4"
(6MM) of insulation off both cut ends of both wires,
twisting any frayed wire strands back together again.
Insert these bare wire ends into the holes in the sides
Fan
Bat.
White
Wires
To DC Power
Source
To Fan
Switch Nut
Switch
Enclosure
Mounting Surface
Switch
IMPORTANT!
CONNECT WIRES
EXACTLY AS
SHOWN!
All Wires Routed
Through Small Slot in
Side of Enclosure
Switch Enclosure
Green
White
4.
STEP 4: Strip the ends of the power wires and
connect them to a FUSED source of 12 volt DC
electrical power (GREEN fan power wire to
POSITIVE, and WHITE fan wire to NEGATIVE).
IMPORTANT: MAKE CONNECTIONS EXACTLY
AS SHOWN. FAN WILL NOT WORK IF WIRING
OR BATTERY CONNECTIONS ARE INCORRECT.
The recommended fuse size is 0.25 amps (for 1 fan)
or 0.5 amps (for 2 fans). This completes the
installation.
LSL Pr
o
d
u
c
ts
8
7
7
-
2
5 7
-
4
6
5
5
H
I
GH
L
O
W
O
F
F
(if used)
Holding Tank
Deodorizer Fan
DoubleSpeed™
11-14VDC @ 0.12/ 0.25 Amps
Green: Positive White: Negative
WARNING:FILTERED DC ONLY!
USE ONLY WITH SUPPLIED SWITCH
LSL Products • San Antonio, TX
Made
In
U.S.A.
STEP-BY-STEP INSTALLATION INSTRUCTIONS
(NOTE: Please Read Entire Instructions Before Starting)
0.7"
BOTTOM VIEW
4.0"
4.0"
0.7"
Supply Voltage:
Supply Current:
100/200 mA Typ.
Air Flow:
42 CFM (Free-Air, HIGH)
Noise Level:
26 dB - A (HIGH)
Motor Type:
Electronic,
DC Brushless
Weight:
15 oz.
Duty Cycle:
Continuous
SPECIFICATIONS — MODEL 19D
SIDE VIEW
1.925" I.D. FEMALE
FITTING, Top &
Bottom
1.3"
2.4"
1.3"
(NOTE:1-1/2" Fittings Shown; Other Versions Similar)
15 Ft. #24 AWG
Stranded T.P.
1
2
3
4
5
1
Enclosure, 3/4" Pipe Fitting
22.50
ITEM #
DESCRIPTION
PRICE EA.
ITEM TOTAL
QTY.
2
Fan Assy., 12 Volt
14.95
3
Wire Splice, Button-Type
.25
4
DC Power Wire, 15 Ft.
3.00
5
.75
6
3.00
6
3.00
Gasket, Bottom Cover
Cover, Bottom, 3/4" Fitting
Cover, Bottom, 1" Fitting
Cover, Bottom, 1-1/4" Fitting
6
3.00
3.00
3.00
.20
8
.30
9
.25
Screw, Cover or Motor Mount
PARTS TOTAL:
PRIORITY MAIL SHIPPING:
TOTAL ENCLOSED:
Lil' Stanker In-Line DoubleSpeed™ Replacement Parts
5.80
NAME:
MAILING ADDRESS:
DAYTIME PHONE:
LSL Products
5804 Babcock Rd. #512
San Antonio, TX 78240
TOLL-FREE: 877-257-4655
www.LSLProducts.net
6
7
9
12
11
1
1
1
1
Cover, Bottom, 1-1/2" Fitting
6
Cover, Bottom, 2" Fitting
6
7
Grommet, Rubber
10
8.95
Switch Assy., With Indicator Light
Enclosure, 1" Pipe Fitting
Enclosure, 1-1/4" Pipe Fitting
Enclosure, 1-1/2" Pipe Fitting
Enclosure, 2" Pipe Fitting
No Minimum Order • No "Handling" Charges • Most Orders Ship Within 24 Hours
Holding Tank
Deodorizer Fan
DoubleSpeed™
11-14VDC @ 0.12/ 0.25 Amps
Green: Positive White: Negative
WARNING:FILTERED DC ONLY!
USE ONLY WITH SUPPLIED SWITCH
LSL Products • San Antonio, TX
Made
In
U.S.A.
REV W
Holding Tank
Deodorizer Fan
DoubleSpeed™
11-14VDC @ 0.12/ 0.25 Amps
Green: Positive White: Negative
WARNING:FILTERED DC ONLY!
USE ONLY WITH SUPPLIED SWITCH
LSL Products • San Antonio, TX
Made
In
U.S.A.
11 - 14 VDC
11
2.25
8
8
12
0.75
Screen, Debris (optional)
7
1.075"
LSL Products 877-257-4655
HIGH
LOW
OFF
1.4"
1.775"
SWITCH
DETAILS
10
Switch Enclosure, With Decal
Decal, External Switch Mounting
22.50
22.50
22.50
22.50

Popular Fan manuals by other brands

Hunter Crossfield 50242 instruction manual

Hunter

Hunter Crossfield 50242 instruction manual

Hunter Anslee Series installation manual

Hunter

Hunter Anslee Series installation manual

Ebmpapst M3G150-NA02-52 operating instructions

Ebmpapst

Ebmpapst M3G150-NA02-52 operating instructions

Ebmpapst R3G250-AV29-B1 operating instructions

Ebmpapst

Ebmpapst R3G250-AV29-B1 operating instructions

Ebmpapst R2E250-RA50-01 operating instructions

Ebmpapst

Ebmpapst R2E250-RA50-01 operating instructions

EGAmaster 79620 operating instructions

EGAmaster

EGAmaster 79620 operating instructions

HAMPTON BAY CALTRIS AK382HG-MBK Use and care guide

HAMPTON BAY

HAMPTON BAY CALTRIS AK382HG-MBK Use and care guide

Ebmpapst VBH0310CTRLS operating instructions

Ebmpapst

Ebmpapst VBH0310CTRLS operating instructions

Ebmpapst A2D210-AA10-17 operating instructions

Ebmpapst

Ebmpapst A2D210-AA10-17 operating instructions

Ebmpapst 8218 J/2H4P operating manual

Ebmpapst

Ebmpapst 8218 J/2H4P operating manual

System air SAVE VSR 150 user manual

System air

System air SAVE VSR 150 user manual

Ebmpapst K1G190-AD73-02 operating instructions

Ebmpapst

Ebmpapst K1G190-AD73-02 operating instructions

OEM Tools OEM24875 Operating instructions and parts manual

OEM Tools

OEM Tools OEM24875 Operating instructions and parts manual

Ebmpapst K3G710-AQ04-19 operating instructions

Ebmpapst

Ebmpapst K3G710-AQ04-19 operating instructions

Power Fist 8979973 user manual

Power Fist

Power Fist 8979973 user manual

Ebmpapst W3G630-GC52-51 operating instructions

Ebmpapst

Ebmpapst W3G630-GC52-51 operating instructions

Ebmpapst K3G310-AX52-91 operating instructions

Ebmpapst

Ebmpapst K3G310-AX52-91 operating instructions

Care Fusion AVEA Quick tips

Care Fusion

Care Fusion AVEA Quick tips

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.