manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Logicbus
  6. •
  7. Switch
  8. •
  9. Logicbus LBIES165024 User manual

Logicbus LBIES165024 User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

LBIES165024
Industrial Ethernet switch
【Introduction】
LBIES165024 is a type of plug-and-play industrial Ethernet
switch which supports 24 RJ45 Ethernet Ports. LBIES165024
adopt our patent technology SW-Ring for the purpose
accomplishing redundancy for Ethernet ring network (self-
recovery time <20ms) to enhance the reliability of the
network. Furthermore, LBIES165024 support numerous
intelligent network management functions, including QoS,
VLAN, Port Trunking, velocity configuration and alarm
enabling functions. To satisfy applications in different industrial
environments. , LBIES165024 can also provide wide temperature
type in accommodation with limit temperature (-40 ~ 75°C).
【Packing List】
The LBIES165024 switch is shipped with following items.
LBIES165024 Ethernet switch(Plus Terminal Block) ×1
Hardware Installation Guide ×1
DIN-Rail setting fittings(wall mounting for optional)
【Features】
Technology
Standard IEEE802.3/802.3u/802.3x/IEEE802.1Q/
IEEE802.1p/IEEE802.3D/IEEE802.3W
Support SW-Ring(Patent technology) self-recovery
time<20ms
Support IEEE802.1Q VLAN
Support IEEE802.1P QoS, support WRR
Support IGMP, port trunking and port mirroring
Support WEB management, easy to management
Support 8K MAC address
Reliable Industrial Grade Design
-40~75℃operating temperature range
No fan design
IP30 protection
19 inch rack mounting
【Panel Layout】
Front panel
Back panel
1. Product marking
2. Console port
3. power/system LED
4. Link/ACT LED
5. 100BaseT(X) Ethernet ports
6. power switch ON/OFF
7. power input terminal block
【Dimension】
LBIES165024
www.logicbus.com
[email protected]
【Power Input】
LBIES165024 provide 3 bits terminal blocks as AC power
input (85~264 V) and DC power input (100~300 V),
terminal diagram is as below,
【Communication Connector】
LBIES165024 provides 24 10/100BaseT(X) Ethernet ports
10/100BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or
STP. The connect distance is no more than 100m. 100Mbps is used
100Ωof UTP 5 , 10Mbps is used 100Ωof UTP 3,4,5.

RJ 45 port support automatic MDI/MDI-X operation. can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connection in MDI. 1→3,2→6,3→1,6→2 are used
as cross wiring in the MDI-X port of Converter and HUB.
10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin
in the table as below.
NO. MDI signal MDI-X signal
1 TX+ RX+
2 TX- RX-
3 RX+ TX+
6 RX- TX-
4、5、7、8 ——
Remark:“TX±”Transmit Data±,“RX±”Receive Data±,“—”Not Use。
MDI (straight-through cable)
MDI-X (Cross over cable)
MDI/MDI-X auto connection makes LBIES165024 easy to
use for customers without considering the type of network cable.
100Base-FX Fiber port
100Base-FX full-duplex SM or MM port, SC/ST type .The
fiber port must be used in pair, TX (transmit) port connect remote
switch’s RX(receive) port; RX(receive) port connect remote
switch’s TX(transmit) port.
The optical fiber connection supports the line to instruct
enhance the reliability of network effectively.
Suppose: If you make your own cable, we suggest labeling the two
sides of the same line with the same letter (A-to-A and B-to-B,
shown as below, or A1-to-A2 and B1-to-B2).
【LED Indicator】
LBIES165024 LED indictor light on the front panel.
the function of each LED is described in the table as below.
System Indication LED
LED State Description
ON Power is being supplied
to power input PWR
input
PWR
(green)
OFF Power is not being
supplied to power input
PWR input
ON System is running well
SYS
(green)OFF System is not running
well
ON Port connection is active
Blinking Data transmitted
Link/ACT
(green)
ON Port connection is not
active
【Installation】
Before installation, confirm that the work environment meet
the installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Screw, nut, tool provide by yourself.
power:DC 110~220V or AC 100~240V
(47~63Hz)
environment:Working temperature -40~75℃
Relative humidity 5%~95%
1 8
www.logicbus.com
[email protected]
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond
the groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines.
Cables, power lines and grounding lines cannot be
overlapped and mixed when they are in the same groove road.
When cable is too long, it cannot hold down other cable, but
structure in the middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of
the cable for maintaining.
【Specification】
Technology
Standard:IEEE802.3、IEEE802.3u、802.3x 、IEEE802.1Q、
IEEE802.1p、IEEE802.3D、IEEE802.3W
Processing type: Store and Forward
Flow control:IEEE802.3x control, backpressure control
MAC address:8K
Interface
RJ45 port:10Base-T/100Base-TX,flow control,full/half duplex,
auto-negotiation work mode,MDI/MDI-X auto-connection
Console port:Debug Serial port
LED indicator:power(PWR)、CPU state(System), Link/ACT
Power
Input Voltage:DC100~300V or AC 85~264V
Input Current:0.25A(@110VAC/VDC)
Type of input:3 bits terminal blocks
Overload Current Protection:4.0A
Mechanical
Shell:Black Metal Case
Installation:19” 1U rack
Dimension(L*H*D):441.6mm×44.6mm×206.9mm
Working Environment
Operating Temperature:-40~75℃
Storage Temperature:-40~85℃
Relative Humidity:5%~95%(non-condensing)
Approvals
Safety:UL508
EMI:FCC Part 15,CISPR (EN55022) class A
EMS:EN61000-4-2 (ESD) ,Level4
EN61000-4-3 (RS) ,Level 3
EN61000-4-4 (EFT) ,Level 4
EN61000-4-5 (Surge) ,Level 4
EN61000-4-6 (CS) ,Level 3
EN61000-4-8,Level 5
Shock:IEC 60068-2-27
Free fall:IEC 60068-2-32
vibration:IEC 60068-2-6
Warranty:5 Years
【Certifications】
www.logicbus.com
[email protected]