LOVATO ELECTRIC EXP10 14 User manual

I297 GB I 11 23 31100147
1
LOVATO ELECTRIC S.P.A.
24020 GORLE (BERGAMO) ITALIA
VIA DON E. MAZZA, 12
TEL. 035 4282111
E-mail info@LovatoElectric.com
Web www.LovatoElectric.com
I
WARNING!
– Carefully read the manual before the installation or use.
– This equipment is to be installed by qualified personnel, complying to current standards, to avoid
damages or safety hazards.
– Remove the dangerous voltage from the product before any maintenance operation on it.
– The manufacturer cannot be held responsible for electrical safety in case of improper use of the
equipment.
– Products illustrated herein are subject to alteration and changes without prior notice. Technical data
and descriptions in the documentation are accurate, to the best of our knowledge, but no liabilities for
errors, omissions or contingencies arising therefrom are accepted.
– Clean the instrument with a soft dry cloth, do not use abrasives, liquid detergents or solvents.
INTRODUCTION
EXP expansion modules are designed and developed to enhance the functions of connectivity, I/O,
memory and analysis of the device to which it is connected.
The EXP10 14 implements the isolated PROFIBUS® serial interface. This module can be connected to a
Lovato Electric device equipped with EXP slot. The connection is done simply by plugging it into the
expansion slot of the base device. Which will automatically recognise it. The EXP parameters setup will
be done directly from the proper device menu in an easy way.
DESCRIPTION
– Compact size
– Direct plug in on the base device
– 2KVrms for 1 minute of insulation from the base module
– PROFIBUS®DP slave, up to 12M
– Max number of exchange bytes 18 INPUT 34 OUTPUT
– Auto Baudrate (9,600-19,200-45,450-93,750-187,500-500,000-1.5M-3M-6M-12M bps)
– Standard 9-pin D-sub female connector
– File .GSD download available (www.lovatoelectric.com).
LOVATO PRODUCTS COMPATIBILITY
EXP10 14 can be connected to a Lovato Electric product fitted by EXP receptacle slot. Verify the
compatibility with the following table:
BASE DEVICE BASE DEVICE FW REV.
ATL610 ≥ 01
ATL800 ≥ 01
DMG7000 ≥ 00
DMG7500 ≥ 00
DMG8000 ≥ 00
DMG9000 ≥ 00
DCRG8 ≥ 07
ATTENZIONE!!
– Leggere attentamente il manuale prima dell’utilizzo e l’installazione.
– Questi apparecchi devono essere installati da personale qualificato, nel rispetto delle vigenti normative
impiantistiche, allo scopo di evitare danni a persone o cose.
– Prima di qualsiasi intervento sull’apparecchio, togliere tensione dagli ingressi di alimentazione e dalle
uscite relè dove presenti.
– Il costruttore non si assume responsabilità in merito alla sicurezza elettrica in caso di utilizzo
improprio del dispositivo.
– I prodotti descritti in questo documento sono suscettibili in qualsiasi momento di evoluzioni o di
modifiche. Le descrizioni ed i dati a catalogo non possono pertanto avere alcun valore contrattuale.
– Pulire lo strumento con panno morbido, non usare prodotti abrasivi, detergenti liquidi o solventi.
INTRODUZIONE
I moduli di espansione EXP... sono stati progettati e sviluppati per potenziare le funzioni di connettività,
I/O, memorizzazione ed analisi dello strumento base a cui vengono collegati. In particolare il modulo
EXP10 14 realizza la funzione di interfaccia seriare isolata di tipo PROFIBUS®. Questo modulo può
essere collegato ad un apparecchio Lovato Electric provvisto di slot per EXP. La connessione avverrà
semplicemente inserendo il modulo di espansione nello strumento principale il quale ne effettuerà
automaticamente il riconoscimento.
L’impostazione dei parametri del modulo viene svolta in modo intuitivo e semplice nel menù di
configurazione presente nel dispositivo principale.
DESCRIZIONE
– Dimensioni compatte.
– Inserimento diretto nello slot di espansione dell’apparecchio.
– Isolamento da 2kVrms per 1minuto dall’apparecchio base.
– PROFIBUS®DP slave fino a 12M.
– Massimo numero di byte di scambio 18 INPUT 34 OUTPUT.
– Auto Baudrate (9.600-19.200-45.450-93.750-187.500-500.000-1.5M-3M-6M-12M bps)
– Connettore standard D-sub 9 poli femmina.
– Download del file .GSD disponibile (www.lovatoelectric.com).
COMPATIBILITÀ CON I PRODOTTI LOVATO
Il modulo EXP10 14 può essere abbinato ad un prodotto Lovato Electric provvisto di alloggiamento per
espansione EXP. Verificare la compatibilità secondo la seguente tabella:
APPARECCHIO BASE REV. SW APPARECCHIO BASE
ATL610 ≥ 01
ATL800 ≥ 01
DMG7000 ≥ 00
DMG7500 ≥ 00
DMG8000 ≥ 00
DMG9000 ≥ 00
DCRG8 ≥ 07
GB EXPANSION MODULE PROFIBUS®DP INTERFACE
Installation manual
MODULO DI ESPANSIONE INTERFACCIA PROFIBUS®DP
Manuale di installazione
EXP10 14
NOTE: THE RELATIVE INSTRUCTIONS MANUAL, DEDICATED TO EACH DEVICE, IS AVAILABLE IN VARIOUS LANGUAGES IN DOWNLOADS AT THE GLOBAL WEBSITE WWW.LOVATOELECTRIC.COM.
NOTA: IL MANUALE OPERATIVO, DEDICATO AD OGNI DISPOSITIVO, È DISPONIBILE IN DIVERSE LINGUE ONLINE NELLA SEZIONE DOWNLOADS ALL’INDIRIZZO WEB WWW.LOVATOELECTRIC.COM.

I297 GB I 11 23 31100147
2
MODULE CONNECTION PROCEDURE PROCEDURA DI CONNESSIONE DEL MODULO
ATL610
DMG
DCRG8
1. Remove any dangerous voltage.
2. Remove the terminal block and the terminal covers if present.
3. Remove the expansion slot cover of the Lovato product at the position in which the EXP will be plug in.
4. Insert the EXP10 14 as illustrated in the picture.
5. Replace the terminal block and the terminal cover if present.
6. Power up the system (the base product will automatically recognize the expansion unit).
NOTE: Remove any dangerous voltage and repeat the operations from step 5 to step 2 in the opposite
direction. Press in the point indicated by the *in the picture in order to remove the module.
1. Rimuovere le tensioni pericolose.
2. Rimuovere la morsettiera estraibile e i coprimorsetti se presenti.
3. Rimuovere il tappo di copertura dello slot nel quale si intende inserire il modulo.
4. Inserire l’EXP10 14 come indicato nella foto.
5. Riposizionare la morsettiera estraibile e montare i coprimorsetti se presenti.
6. Alimentare lo strumento principale (verrà riconosciuto il nuovo modulo di espansione).
NOTA: per togliere il modulo, rimuovere ogni tensione pericolosa e ripetere in senso contrario le
operazioni dal punto 5 al punto 2. Premere nel punto indicato con *per sganciare il modulo.
WARNING!
When the EXP... module is installed on a DMG series multimeter, it is mandatory to install the
sealable terminal block covers supplied with the multimeter.
ATTENZIONE!
Quando vengono installati i moduli EXP nei multimetri della serie DMG, è obbligatorio
montare i coprimorsetti piombabili forniti con il multimetro.

I297 GB I 11 23 31100147
3
MECHANICAL DIMENSIONS [mm DIMENSIONI MECCANICHE [mm
22.0
64.5
41.7
38.2
46.8
PINOUT
PROFIBUS®
CONNECTOR (DB9F)
PIN FUCTION
1
2
3B-Line
4 RTS
5 GND BUS(isolated)
6 +5V BUS(output isolated,100mA max)
7
8 A-Line
9
PINOUT
CONNETTORE
PROFIBUS®
PIN FUNZIONE
1
2
3B-Line
4 RTS
5 GND BUS(isolata)
6 +5V BUS(output isolata,100mA max)
7
8 A-Line
9
GB
TECHNICAL CHARACTERISTICS
Supply
Supply voltage 5V=
(supplied by base device)
Consumption 190mA
Power consumption/dissipation 0.95W
PROFIBUS®inter ace
Auto baudrate 9,600bps - 19,200bps - 45,450bps - 93,750bps -
187,500bps -500,000bps - 1.5Mbps - 3Mbps -
6Mbps - 12Mbps
Protocols Supported PROFIBUS®DP
PROFIBUS®port connection
Connector type DB9F
Base product connection
Type of terminal Plug-in connector
Insulation
Power frequency withstand voltage 2kV
Ambient conditions
Operating temperature -20 - +60°C
Storage temperature -30 - +80°C
Relative humidity <90% (IEC/EN 60068-2-70)
Maximum pollution degree 2
Overvoltage category 3
Altitude ≤2000m
Climatic sequence Z/ABDM (IEC/EN 60068-2-61)
Shock resistance 15g (IEC/EN 60068-2-27)
Vibration resistance 0.7g (IEC/EN 60068-2-6)
Housing
Mounting For inclusion in the EXP plug in expansion slot
Material Polyamide RAL7035
Degree of protection IP20
Weight 80g
Certi ications and compliance
Certifications obtained cULus
Comply with standards IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/ EN 61000-6-3
UL508, CSA C22.2 N°14
I
CARATTERISTICHE TECNICHE
Alimentazione
Tensione alimentazione 5V=
(fornita dall’apparecchio principale)
Corrente assorbita 190mA
Potenza assorbita/dissipata 0,95W
Inter accia PROFIBUS®
Auto baudrate 9.600bps - 19.200bps - 45.450bps - 93.750bps -
187.500bps - 500.000bps - 1,5Mbps - 3Mbps -
6Mbps - 12Mbps
Protocolli supportati PROFIBUS®DP
Connessione porta PROFIBUS®
Tipo di connettore DB9F
Connessione al prodotto base
Tipo di connettore Connettore ad innesto
Isolamento
Tensione di tenuta a frequenza d’esercizio 2kV
Condizioni ambientali
Temperatura d’impiego -20 - +60°C
Temperatura di stoccaggio -30 - +80°C
Umidità relativa <90% (IEC/EN 60068-2-70)
Grado di inquinamento ambiente massimo 2
Categoria dì sovratensione 3
Altitudine ≤2000m
Sequenza climatica Z/ABDM (IEC/EN 60068-2-61)
Resistenza agli urti 15g (IEC/EN 60068-2-27)
Resistenza alle vibrazioni 0,7g (IEC/EN 60068-2-6)
Contenitore
Montaggio Ad inserimento nello slot di espansione plug in EXP
Materiale Poliammide RAL 7035
Grado di protezione IP20
Peso 80g
Omologazioni e con ormità
Omologazioni ottenute cULus
Conformità a norme IEC/EN 61010-1, IEC/EN 61000-6-2, IEC/ EN 61000-6-3
UL508, CSA C22.2 N°14
Other manuals for EXP10 14
4
Other LOVATO ELECTRIC Extender manuals
Popular Extender manuals by other brands

SMART-AVI
SMART-AVI UTX-500 installation manual

AirStage
AirStage UTY-VSGXZ1 installation manual

NTI
NTI XTENDEX ST-C6HD-HDBT Installation and operation manual

Konan Labs
Konan Labs KVC-EB120UIS user manual

Black Box
Black Box ServSwitch Wizard ACU5050A-R2 user manual

TV One
TV One 1T-FC-677 instruction manual