Lucent MAX 6000 Series Instruction Manual

MAX™
Administration Guide
Part number 7820-0678-002
For software version 9.0
January 2001

Lucent Technologies
Copyright © 2000, 2001 Lucent Technologies Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any
entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express
written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to [email protected].
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change.
Safety, Compliance, and Warranty Information
Before handling any Lucent Access Networks hardware product, read the Edge Access Safety and Compliance Guide included in your product package. See
that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country. See
the warranty card included in your product package for the limited warranty that Lucent Technologies provides for its products.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features.
Trademarks
4ESS, 5ESS, A Network of Expertise, AnyMedia, APX 8000, AqueView, AUDIX, B-STDX 8000, B-STDX 9000, ...Beyond Compare, CaseView, Cajun,
CajunDocs, CAJUNVIEW, Callmaster, CallVisor, CBX 500, CellPipe, ChoiceNet, ClearReach, ComOS, cvMAX, DACScan, Dacsmate, Datakit, DEFINITY,
Definity One, DSLMAX, DSLTerminator, DSLPipe, DSLTNT, Elemedia, Elemedia Enhanced, EMMI, End to End Solutions, EPAC, eSight, ESS,
EVEREST, Gigabit-scaled campus networking, Globalview, GRF, GX 250, GX 550, HyperPATH, Inferno, InfernoSpaces, Intragy, IntragyAccess,
IntragyCentral, Intuity, IP Navigator, IPWorX, LineReach, LinkReach, MAX, MAXENT, MAX TNT, Multiband, Multiband PLUS, Multiband RPM,
MultiDSL, MultiVoice, MultiVPN, Navis, NavisAccess, NavisConnect, NavisCore, NavisRadius, NavisXtend, NetCare, NetLight, NetPartner, OneVision,
Open Systems Innovations, OpenTrunk, P550, PacketStar, PathStar, Pinnacle, Pipeline, PMVision, PortMaster, SecureConnect, Selectools, Series56,
SmoothConnect, Stinger, SYSTIMAX, True Access, WaveLAN, WaveMANAGER, WaveMODEM, WebXtend, and Where Network Solutions Never End
are trademarks of Lucent Technologies Inc. Advantage Pak, Advantage Services, AnyMedia, ...Beyond Compare, End to End Solutions, Inter.NetWorking,
MAXENT, and NetWork Knowledge Solutions are service marks of Lucent Technologies Inc. Other trademarks, service marks, and trade names mentioned in
this publication belong to their respective owners.
Copyrights for Third-Party Software Included in Lucent Access Networks Software Products
C++ Standard Template Library software copyright© 1994 Hewlett-Packard Company and copyright© 1997 Silicon Graphics. Permission to use, copy,
modify, distribute, and sell this software and its documentation for any purpose is hereby granted without fee, provided that the above copyright notice appear
in all copies and that both that copyright notice and this permission notice appear in supporting documentation. Neither Hewlett-Packard nor Silicon Graphics
makes any representations about the suitability of this software for any purpose. It is provided “as is” without express or implied warranty.
Berkeley Software Distribution (BSD) UNIX software copyright© 1982, 1986, 1988, 1993 The Regents of California. All rights reserved. Redistribution and
use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code
must retain the above copyright notice, this list of conditions, and the following disclaimer. 2. Redistributions in binary form must reproduce the above copy-
right notice, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. All advertising
materials mentioning features or use of this software must display the following acknowledgement: This product includes software developed by the Univer-
sity of California, Berkeley, and its contributors. 4. Neither the name of the University nor the names of its contributors may be used to endorse or promote
products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES; LOSS OF USE, DATA OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Ordering Information
You can order the most up-to-date product information and computer-based training online at http://www.lucent.com/ins/bookstore.
Feedback
Lucent Technologies appreciates your comments, either positive or negative, about this manual. Please send them to techpubs@ascend.com.

MAX Administration Guide iii
Customer Service
To obtain product and service information, software upgrades, and technical assistance, visit
the eSight™ Service Center at http://www.esight.com. The center is open 24 hours a
day, seven days a week.
Finding information and software
The eSight Service Center at http://www.esight.com provides technical information,
product information, and descriptions of available services. Log in and select a service. The
eSight Service Center also provides software upgrades, release notes, and addenda. Or you can
visit the FTP site at ftp://ftp.ascend.com for this information.
Obtaining technical assistance
The eSight™ Service Center at http://www.esight.com provides access to technical
support. You can obtain technical assistance through email or the Internet, or by telephone.
If you need to contact Lucent Technologies for assistance, make sure that you have the
following information available:
• Active contract number, product name, model, and serial number
• Software version
• Software and hardware options
• If supplied by your carrier, service profile identifiers (SPIDs) associated with your line
• Your local telephone company’s switch type and operating mode, such as AT&T 5ESS
Custom or Northern Telecom National ISDN-1
• Whether you are routing or bridging with your Lucent product
• Type of computer you are using
• Description of the problem
Obtaining assistance through email or the Internet
If your services agreement allows, you can communicate directly with a technical engineer
through Email Technical Support or eSight Live chat. Select one of these sites when you log in
to http://www.esight.com.
Calling the technical assistance center (TAC)
If you cannot find an answer through the tools and information on eSight or if you have a very
urgent need, contact TAC. Access the eSight Service Center at http://www.esight.com
and click Contact Us below the Lucent Technologies logo for a list of telephone numbers
inside and outside the United States.
You can alternatively call (800) 272-3634 for a menu of Lucent services, or call
(510) 769-6001 for an operator. If you do not have an active services agreement or contract,
you will be charged for time and materials.

MAX Administration Guide v
Table of Contents
Customer Service ..................................................................................................................... iii
About This Guide............................................................................ xvii
What you should know ......................................................................................................... xvii
Documentation conventions ................................................................................................. xviii
The MAX documentation set ..................................................................................................xix
Chapter 1 Administering MAX Hardware ....................................................... 1-1
Troubleshooting POST .......................................................................................................... 1-1
Interpreting indicator lights .................................................................................................... 1-2
MAX 6000 ...................................................................................................................... 1-2
MAX 3000 ...................................................................................................................... 1-5
Troubleshooting the Fault indicator light .......................................................................1-7
MAX 800 ........................................................................................................................1-7
Troubleshooting the No Logical Link status .......................................................................... 1-9
Troubleshooting the AIM port interface ................................................................................ 1-9
Testing the AIM port interface ..................................................................................... 1-10
Calls fail between AIM ports ........................................................................................ 1-10
Excessive data errors on calls to AIM ports .................................................................1-11
Troubleshooting a codec ...................................................................................................... 1-12
The codec indicates that there is no connection ...........................................................1-12
The codec does not receive data ................................................................................... 1-12
The codec cannot establish a call ..................................................................................1-13
Calls initiated by control-lead toggling are cleared too soon .......................................1-13
The codec cannot clear a call ........................................................................................ 1-13
Troubleshooting cable issues ............................................................................................... 1-14
Displaying interface statistics .............................................................................................. 1-14
Using modems to perform administrative tasks ...................................................................1-16
Booting from a FAT-formatted PCMCIA card .................................................................... 1-17
Chapter 2 DO Commands and Administrative Tasks.................................... 2-1
Activating administrative permissions ................................................................................... 2-1
Performing basic administration ............................................................................................ 2-3
Managing sessions .......................................................................................................... 2-3
Copying FXS profiles with the DO Commands .............................................................2-4
Managing calls ................................................................................................................2-5
Testing and troubleshooting ...................................................................................................2-6
Using bit-error tests ........................................................................................................ 2-6
Using remote loopback ...................................................................................................2-8
Using remote management ........................................................................................... 2-10
DO Command operations .............................................................................................2-11

vi MAXAdministrationGuide
Contents
Chapter 3 Terminal-Server Administrative Tasks.......................................... 3-1
Enabling and configuring the interface .................................................................................. 3-1
Configuring the interface ................................................................................................ 3-2
Configuring the Session Options profile ........................................................................ 3-3
Navigating to and from the interface ..................................................................................... 3-4
Testing the MAX unit ............................................................................................................ 3-4
Understanding test results ...................................................................................................... 3-6
Starting remote management sessions ................................................................................... 3-7
Disconnecting user Telnet connections .................................................................................. 3-9
Using Set commands .............................................................................................................. 3-9
Enable password mode ...........................................................................................................3-9
Using Show commands ........................................................................................................ 3-10
Displaying uptime and revision .................................................................................... 3-10
Displaying modem status .............................................................................................. 3-11
Displaying V.110 terminal adapter status ..................................................................... 3-12
Displaying call and user activity ................................................................................... 3-13
Displaying active sessions ............................................................................................ 3-13
Displaying Dialed Number Information Service activity ............................................. 3-15
Using the Show Filters command ................................................................................. 3-17
Displaying information related to virtual routing ......................................................... 3-21
Chapter 4 Changing System Software Versions ........................................... 4-1
Preparing to change system software .....................................................................................4-2
Enabling Field Service and Operations parameters ........................................................4-2
Staying with the same software build .............................................................................4-2
Alternative builds for a MAX 6000 unit .........................................................................4-2
Using TFTP to upgrade or downgrade ...................................................................................4-3
Creating redundant backup images for a MAX 6000 unit .............................................. 4-3
Using TFTP to upgrade ................................................................................................... 4-4
Using TFTP to downgrade .............................................................................................. 4-5
Using the serial port to upgrade or downgrade ......................................................................4-6
Saving your current profiles ........................................................................................... 4-6
Upgrading system software ............................................................................................4-7
After the upgrade ............................................................................................................ 4-8
Restoring correct RADIUS parameters .................................................................................. 4-8
Notice of discontinuance of configurable RADIUS port and ID space .................................4-9
Chapter 5 Administering E1 and T1 Services................................................ 5-1
Troubleshooting a Red Alarm ................................................................................................ 5-2
Verifying enabled lines ................................................................................................... 5-2
Verifying Framing Mode settings ...................................................................................5-3
Resolving cabling issues .................................................................................................5-3
Summary of Red Alarm causes and solutions ................................................................ 5-3
Troubleshooting a blinking Alarm ......................................................................................... 5-4
Integrated CSU for T1/PRI ............................................................................................. 5-4
Remedying D-channel issues .......................................................................................... 5-5
Summary of blinking Alarm potential causes and possible solutions ............................ 5-7
Using Net/E1 and Net/T1 status windows ............................................................................. 5-7
Listing WAN interface features ...................................................................................... 5-7
Displaying errors ............................................................................................................. 5-8

Contents
MAX Administration Guide vii
Displaying link and channel status ................................................................................. 5-8
Displaying FDL statistics .............................................................................................. 5-10
Fractional T1 services ...................................................................................................5-12
Using line diagnostics .......................................................................................................... 5-13
Clearing user error event and performance registers .................................................... 5-13
Initiating a line loopback test ........................................................................................ 5-14
Swapping NFAS status ................................................................................................. 5-14
Testing the lines ............................................................................................................5-15
Remedying Trunk Down state .............................................................................................5-15
Using terminal-server commands ........................................................................................5-16
Resetting the unit and clearing calls ............................................................................. 5-16
Displaying the source of clocking ................................................................................5-16
Specifying channels for E1 and T1 ...................................................................................... 5-17
Verifying E1 and T1 parameter settings ..............................................................................5-17
E1-specific parameter settings ...................................................................................... 5-17
T1-specific parameter settings ...................................................................................... 5-18
Fractional T1-specific parameters ................................................................................ 5-19
T1/PRI-specific parameters .......................................................................................... 5-20
PBX-T1 specific parameters ......................................................................................... 5-21
Troubleshooting channels .................................................................................................... 5-22
Chapter 6 Administering ISDN........................................................................ 6-1
Troubleshooting BRI interface problems ............................................................................... 6-1
WAN calling errors in outbound Net/BRI calls .............................................................. 6-1
Calls are not dialed or answered reliably ........................................................................ 6-2
The Net/BRI lines do not dial or answer calls ................................................................6-2
Displaying E1 ISDN call information .................................................................................... 6-2
Displaying ISDN events .........................................................................................................6-3
Understanding ISDN cause codes .......................................................................................... 6-4
Chapter 7 Administering TCP/IP..................................................................... 7-1
Managing the Internet Protocol (IP) ...................................................................................... 7-2
IP-routing environment ................................................................................................... 7-2
Displaying IP information .............................................................................................. 7-2
Troubleshooting IP routing ............................................................................................. 7-3
Displaying IP route statistics ..........................................................................................7-7
Displaying IP statistics and addresses ............................................................................ 7-8
RIP updates and IP routes ...............................................................................................7-9
Displaying address pool status ...................................................................................... 7-10
Displaying DNS-related information ................................................................................... 7-10
Displaying the local DNS fallback table .......................................................................7-10
Editing the local DNS table ..........................................................................................7-12
Displaying Multicast information ........................................................................................7-13
Displaying the multicast forwarding table .................................................................... 7-13
Listing multicast clients ................................................................................................7-14
Displaying IP-multicast activity ................................................................................... 7-15
Using VRouter-related terminal-server commands .............................................................7-15
Displaying UDP packet information .................................................................................... 7-16
Managing the Address Resolution Protocol (ARP) .............................................................7-19
Displaying and clearing the ARP cache ...............................................................................7-19
Managing the Internet Control Message Protocol (ICMP) ..................................................7-20

viii MAX AdministrationGuide
Contents
Pinging remote IP hosts ................................................................................................7-21
Displaying ICMP information ...................................................................................... 7-22
Preventing ICMP security breaches .............................................................................. 7-22
Managing the Routing Information Protocol (RIP) ............................................................. 7-23
Verifying the transmission path to NetWare stations ...................................................7-23
Displaying IPX packet statistics ................................................................................... 7-25
Displaying the IPX service table .................................................................................. 7-25
Displaying the IPX routing table .................................................................................. 7-25
Managing the Open Shortest Path First (OSPF) protocol .................................................... 7-26
Displaying OSPF information ...................................................................................... 7-26
Verifying OSPF-related parameter settings ..................................................................7-36
Working with the OSPF routing table .......................................................................... 7-37
Multipath routing .......................................................................................................... 7-39
Third-party routing ....................................................................................................... 7-40
How OSPF adds RIP routes .......................................................................................... 7-40
Route preferences .........................................................................................................7-40
MD5 cryptographic authentication ............................................................................... 7-42
Enabling Finger support ....................................................................................................... 7-42
Understanding the AppleTalk-routing environment ............................................................7-43
Chapter 8 Administering PAD, X.25, and Frame Relay ................................. 8-1
Administering X.25 ................................................................................................................8-1
Displaying information about X.25 ................................................................................ 8-2
X.25 clear cause codes .................................................................................................... 8-3
X.25 diagnostic field values ............................................................................................ 8-3
Administering PAD ................................................................................................................ 8-5
Displaying information about PAD sessions .................................................................. 8-6
Verifying PAD-related settings ...................................................................................... 8-6
Understanding PAD service signals ............................................................................... 8-7
Administering Frame Relay ................................................................................................... 8-8
Using the Set commands to configure Frame Relay .............................................................. 8-9
Chapter 9 Using Traps to Monitor Performance............................................ 9-1
Establishing SNMP access security ....................................................................................... 9-1
Enabling SNMP Set commands ...................................................................................... 9-2
Setting community strings .............................................................................................. 9-2
Setting up and enforcing address security ......................................................................9-2
Resetting the MAX and verifying reset .......................................................................... 9-2
Specifying User-based security ...................................................................................... 9-3
Example of SNMP security configuration ...................................................................... 9-3
Using the SNMPv3 User-based Security Model ....................................................................9-4
Verifying Network Management is installed .................................................................. 9-4
Required SNMP Options profile settings ....................................................................... 9-4
Required SNMPv3 USM Users profile settings ............................................................. 9-5
Using SNMP traps ................................................................................................................. 9-6
Understanding the SNMP trap parameters ..................................................................... 9-7
Example SNMP trap configuration .................................................................................9-7
Enable Traps profile settings ..........................................................................................9-8
Using OSPF-related SNMP traps ......................................................................................... 9-10
SNMP Trap profile settings .......................................................................................... 9-10
Mod Config settings ...................................................................................................... 9-10

Contents
MAX Administration Guide ix
Enable Traps profile settings ........................................................................................9-11
Administering virtual interfaces ...................................................................................9-11
Administering nonvirtual interfaces ............................................................................. 9-12
Administering Link-State Advertisements ................................................................... 9-13
Matching an OSPF trap to an SNMP trap ID in RFC 1850 .......................................... 9-13
Alarm/Error and Security events .......................................................................................... 9-14
Alarm/Error events ....................................................................................................... 9-14
Security events .............................................................................................................. 9-15
Appendix A Understanding Syslog messages .................................................A-1
Verifying Syslog support ...................................................................................................... A-2
Understanding Message Log status window ......................................................................... A-2
Understanding Level 4 and Level 6 messages ...................................................................... A-3
Understanding Level 5 messages .......................................................................................... A-4
Gathering tunneling information ........................................................................................... A-4
Call ID values ........................................................................................................................ A-5
ATMP-related disconnect codes ........................................................................................... A-5
Understanding disconnect codes and progress codes ........................................................... A-6
Disconnect codes and their meanings ................................................................................... A-7
Progress codes and their meanings ..................................................................................... A-10
Code combinations and their possible meanings ................................................................ A-12
Appendix B Diagnostic Parameters and Commands .......................................B-1
Using diagnostics-related VT100 commands ........................................................................B-1
Using administrator-only commands ..............................................................................B-1
Using BRI/LT-related commands ...................................................................................B-5
Using E1-related commands ...........................................................................................B-8
Using Host/Dual (Host/6) Port-related commands .........................................................B-9
Using Modem-related commands .................................................................................B-10
Using T1-related commands .........................................................................................B-12
Using diagnostics-related DO commands ............................................................................B-14
? .....................................................................................................................................B-14
ARPTable ......................................................................................................................B-15
Clocksource ..................................................................................................................B-16
Clr-History ....................................................................................................................B-17
CoreDump .....................................................................................................................B-17
Diag ...............................................................................................................................B-18
Diag ? ............................................................................................................................B-18
Diag AddrPool ..............................................................................................................B-20
Diag Callback ...............................................................................................................B-21
Diag IPXrip ...................................................................................................................B-21
Diag Modemdrv ............................................................................................................B-22
Diag Networki ...............................................................................................................B-25
Diag PPPFSM ...............................................................................................................B-25
Diag PPPIF ...................................................................................................................B-27
Diag PPTPData .............................................................................................................B-28
Diag RadAcct ................................................................................................................B-28
Diag RadIF ....................................................................................................................B-29
Diag Routmgr ...............................................................................................................B-30
Diag SNTP ....................................................................................................................B-30
Diag Telnet ...................................................................................................................B-31

xMAXAdministrationGuide
Contents
Ether-Display ................................................................................................................B-31
Fatal-History .................................................................................................................B-32
FClear ............................................................................................................................B-36
FRestore ........................................................................................................................B-36
FSave ............................................................................................................................B-36
Heartbeat .......................................................................................................................B-36
Help ...............................................................................................................................B-37
Lanport Modem ............................................................................................................B-37
Lcstate ...........................................................................................................................B-38
MdbStr ..........................................................................................................................B-39
MDialout .......................................................................................................................B-40
ModemDiag ..................................................................................................................B-40
ModemDrvDump ..........................................................................................................B-42
NetRoute .......................................................................................................................B-42
NSLookup .....................................................................................................................B-42
NVRAMClear ...............................................................................................................B-43
PPPDump N ..................................................................................................................B-44
PPPInfo .........................................................................................................................B-44
PPTPCM .......................................................................................................................B-45
PPTPEC ........................................................................................................................B-45
PPTPSend .....................................................................................................................B-46
PRIDisplay ....................................................................................................................B-46
Quit ...............................................................................................................................B-47
RadStats ........................................................................................................................B-47
Reset ..............................................................................................................................B-48
Revision ........................................................................................................................B-48
T1coredisplay ................................................................................................................B-49
Tempdisplay ..................................................................................................................B-49
TLoadCode ...................................................................................................................B-49
TRestore ........................................................................................................................B-51
TSave ............................................................................................................................B-51
Update ...........................................................................................................................B-51
WANDisplay ................................................................................................................B-52
WANDSess ...................................................................................................................B-53
WANNext .....................................................................................................................B-53
WANOpening ...............................................................................................................B-54
WDDialout ....................................................................................................................B-54
Using diagnostics-related DO commands for the MAX 6000 unit’s PCMCIA card ...........B-54
FImageCopy ..................................................................................................................B-54
Fload .............................................................................................................................B-55
Format ...........................................................................................................................B-56
FVersionInfo .................................................................................................................B-56
Ls ..................................................................................................................................B-57
MkDir ............................................................................................................................B-57
Mv .................................................................................................................................B-57
Rm .................................................................................................................................B-58
TLoadCode ...................................................................................................................B-58
Understanding Diagnostic command output ........................................................................B-59
Breaking down the raw data .................................................................................................B-60

Contents
MAX Administration Guide xi
Appendix C Machine Interface Format (MIF) .....................................................C-1
Accessing the interface ..........................................................................................................C-1
Using full and partial addresses .............................................................................................C-2
Using supported commands ...................................................................................................C-4
Understanding responses ................................................................................................C-4
Loading and saving entities ............................................................................................C-4
Getting an entity’s current value .....................................................................................C-5
Getting the address and value of the next entity .............................................................C-5
Modifying parameter values ...........................................................................................C-6
MIF traps and asynchronous reports ...............................................................................C-6
Understanding command-line basics .....................................................................................C-7
Modifying an entity in the edit area .......................................................................................C-8
Using supported types ..........................................................................................................C-10
Index...........................................................................................Index-1

MAX Administration Guide Preliminary February 2, 2001 xiii
Figures
Figure 1-1 MAX 6000 front panel....................................................................................... 1-2
Figure 1-2 Redundant MAX 6000 front panel .................................................................... 1-3
Figure 1-3 MAX 6000 back-panel indicator lights.............................................................. 1-4
Figure 1-4 MAX 3000 front panel....................................................................................... 1-5
Figure 1-5 MAX 3000 back-panel indicator lights.............................................................. 1-6
Figure 1-6 MAX 800 back panel......................................................................................... 1-9
Figure 7-1 Example IP-routed environment........................................................................ 7-2
Figure 7-2 Example AppleTalk-routed environment ........................................................ 7-44

MAX Administration Guide xv
Tables
Table 1-1 MAX 6000 front-panel indicator lights ............................................................. 1-2
Table 1-2 Redundant MAX 6000 front panel lights .......................................................... 1-3
Table 1-3 MAX 6000 back-panel indicator lights.............................................................. 1-4
Table 1-4 MAX 3000 front-panel indicator lights ............................................................. 1-5
Table 1-5 MAX 3000 back-panel indicator lights.............................................................. 1-6
Table 1-6 MAX 800 front panel lights............................................................................... 1-7
Table 1-7 PCMCIA card-related indicator lights............................................................... 1-8
Table 1-8 Output of the Show If Stats command............................................................. 1-15
Table 1-9 Show If command output................................................................................. 1-16
Table 1-10 Summary of PCMCIA file management commands....................................... 1-19
Table 2-1 DO menu commands for activating administrative permissions....................... 2-2
Table 2-2 DO menu commands for session management.................................................. 2-4
Table 2-3 DO menu commands for call management........................................................ 2-6
Table 2-4 DO menu commands for testing and troubleshooting ..................................... 2-10
Table 3-1 TServ Options parameters.................................................................................. 3-2
Table 3-2 Session Options parameters............................................................................... 3-3
Table 3-3 Returning to the VT100 interface...................................................................... 3-4
Table 3-4 Output of Show Modems command................................................................ 3-12
Table 3-5 Show calls output............................................................................................. 3-13
Table 3-6 Show Users command output .......................................................................... 3-14
Table 3-7 DO menu commands for specific protocols..................................................... 3-17
Table 5-1 Red Alarm potential causes and solutions......................................................... 5-3
Table 5-2 Blinking Alarm potential causes and possible solutions ................................... 5-7
Table 5-3 Link-status indicators......................................................................................... 5-9
Table 5-4 Channel-status indicators................................................................................. 5-10
Table 5-5 FDL performance registers.............................................................................. 5-11
Table 5-6 Net/T1 diagnostic commands .......................................................................... 5-15
Table 5-7 E1 parameters and settings............................................................................... 5-18
Table 5-8 T1-specific parameters..................................................................................... 5-19
Table 5-9 Fractional T1-specific parameters.................................................................... 5-19
Table 5-10 T1-PRI-specific parameters............................................................................. 5-20
Table 5-11 PBX-T1 parameters and settings ..................................................................... 5-21
Table 6-1 ISDN cause codes.............................................................................................. 6-4
Table 6-2 ISDN cause codes for 1TR6 switch type........................................................... 6-7
Table 7-1 Traceroute command syntax elements............................................................... 7-3
Table 7-2 Time field responses and annotations................................................................ 7-4
Table 7-3 IP routing table fields and definitions ............................................................... 7-6
Table 7-4 Output of the Show Dnstab command............................................................. 7-11
Table 7-5 Output of the Show IGMP Groups command ................................................. 7-13
Table 7-6 Output of the Show IGMP Clients command.................................................. 7-14
Table 7-7 VRouter-related terminal-server commands.................................................... 7-15
Table 7-8 VRouter-related terminal-server commands.................................................... 7-16
Table 7-9 Show commands, specified protocols, and network-specific information...... 7-17

xvi MAXAdministrationGuide
Tables
Table 7-10 T1 channel status indicators............................................................................. 7-18
Table 7-11 OSPF routing table........................................................................................... 7-38
Table 7-12 MD5 Cryptographic parameters ...................................................................... 7-42
Table 8-1 Clear cause codes............................................................................................... 8-3
Table 8-2 X.25 diagnostic field values............................................................................... 8-3
Table 8-3 PAD-specific parameters................................................................................... 8-6
Table 8-4 PAD service signal messages............................................................................. 8-8
Table 8-5 Set commands.................................................................................................... 8-9
Table 9-1 SNMPv3-related parameters.............................................................................. 9-6
Table 9-2 Trap-related parameters..................................................................................... 9-8
Table 9-3 Virtual interface-related OSPF traps................................................................ 9-11
Table 9-4 Nonvirtual interface-related OSPF traps.......................................................... 9-12
Table 9-5 LSA-related OSPF Traps parameters............................................................... 9-13
Table A-1 Summary of Syslog settings ............................................................................. A-2
Table A-2 Level 4 and Level 6 syslog messages............................................................... A-3
Table A-3 Level 5 Syslog messages .................................................................................. A-4
Table C-1 Syntax element descriptions .............................................................................. C-2
Table C-2 Command-line processing ................................................................................. C-7
Table C-3 Line-editing conventions ................................................................................... C-8

MAX Administration Guide xvii
About This Guide
The MAX™ Administration Guide is intended to help you as you measure, maintain,
administer, and troubleshoot the performance of MAX 6000, MAX 3000, and MAX 800 units.
A reference to a specific MAX model always accompanies information that applies only to that
model. For example, if a description indicatesMAX 6000, then that information applies only to
MAX 6000 units. If a description indicates MAX, then that information applies to the MAX
6000, MAX 3000, or MAX 800 unit that is configured to support the feature being described.
To assure continuing satisfactory performance of a MAX unit make use of its indicator lights,
the VT100 interface, the terminal-server command-line interface (CLI), DO commands,
SNMP, and the Syslog.
!Warning: Before installing or operating your MAX unit, be sure to read the safety
instructions in the Edge Access Safety and Compliance Guide. For information specific to your
unit, see the “Safety-Related Electrical, Physical, and Environmental Information” appendix in
your unit’s hardware installation guide.
Navigation and usage of all the user interfaces are described in the Hardware Installation and
Basic Configuration Guide for your unit. You will continue to apply that information as you
use this guide.
The flexibility of the True Access™ Operating System (TAOS) software and hardware
architecture of the MAX base unit allows you to introduce services as you need them. The
MAX offers flash memory, slot cards, and software upgradable protocol support. You can
upgrade the features that the MAX unit supports by changing the version of TAOS software
running on the unit. The flexiblity of the system software and hardware architecture also
results in support for over 15 WAN protocols. The MAX also supports several virtual private
networking, several modem, and several bandwidth management protocols. Although the
flexibility of the unit’s TAOS software and hardware architecture can make the tasks quite
complicated, this guide intends to help you discern how best to assure satisfactory
performance. Use this guide to gather information about the performance of the MAX unit and
to eliminate problems that you may discover.
Note: This manual describes the full set of features for MAX 6000, MAX 3000, and MAX
800 units. Some features might not be available with earlier versions or specialty loads of the
software.
What you should know
This guide is for the person who configures and maintains MAX units. To configure a unit, you
need to understand the following:
• Internet or telecommuting concepts

xviii MAXAdministrationGuide
About This Guide
Documentation conventions
• WAN concepts
• LAN concepts, if applicable
Documentation conventions
Following are all the special characters and typographical conventions used in this manual:
Convention Meaning
Monospace text Represents text that appears on your computer’s screen, or that could
appear on your computer’s screen.
Boldface
monospace text Represents characters that you enter exactly as shown (unless the
characters are also in
italics
—see Italics, below). If you could
enter the characters but are not specifically instructed to, they do not
appear in boldface.
Italics Represent variable information. Do not enter the words themselves in
the command. Enter the information they represent. In ordinary text,
italics are used for titles of publications, for some terms that would
otherwise be in quotation marks, and to show emphasis.
[ ] Square brackets indicate an optional argument you might add to a
command. To include such an argument, type only the information
inside the brackets. Do not type the brackets unless they appear in
boldface.
| Separates command choices that are mutually exclusive.
> Points to the next level in the path to a parameter or menu item. The
item that follows the angle bracket is one of the options that appear
when you select the item that precedes the angle bracket.
Key1-Key2 Represents a combination keystroke. To enter a combination
keystroke, press the first key and hold it down while you press one or
more other keys. Release all the keys at the same time. (For example,
Ctrl-H means hold down the Control key and press the H key.)
Press Enter Means press the Enter, or Return, key or its equivalent on your
computer.
Note: Introduces important additional information.
!
Caution: Warns that a failure to follow the recommended procedure could result
in loss of data or damage to equipment.
!
Warning: Warns that a failure to take appropriate safety precautions could result
in physical injury.
Warning:
Warns of danger of electric shock.

About This Guide
The MAX documentation set
MAX Administration Guide xix
The MAX documentation set
The MAX documentation set is available on the Documentation Library CD-ROM included
with your MAX unit. You can order additional copies of the documentation on CD-ROM or
paper from the online bookstore or you can view the documentation online. Go to
http://www.lucent.com/ins/doclibrary for more information about these
options.
The MAX documentation set consists of the following manuals:
•TheEdge Access Safety and Compliance Guide
•TheMAX Administration Guide (This volume)
•TheHardware Installation and Basic Configuration Guide for your MAX 6000,
MAX 3000, or MAX 800 unit
•The
Network Configuration Guide for your MAX 6000, MAX 3000, or MAX 800 unit
•TheMAX Reference
•TheMAX Security Supplement
•TheTAOS Glossary
•TheTAOS RADIUS Guide and Reference

MAX Administration Guide 1-1
1
Administering MAX Hardware
From the moment you turn on the power and the MAX unit initiates a power-on self test
(POST), you can gather information that allows you to troubleshoot the MAX. Once the MAX
is running, you can interpret the indicator lights that the unit includes on its front panel and
back-panel. These indicator lights, combined with performance indicators, can lead you to
discover hardware and other issues such as problems with the configuration, the Ascend
Inverse Multiplexing (AIM) port, related Codec devices, and cables.
For E1, T1, and BRI interface-related information see Chapter 5, “Administering E1 and T1
Services” and Chapter 6, “Administering ISDN.”
Troubleshooting POST
A Power-on self test (POST) is a diagnostic test the MAX unit performs when it first starts up
or after it completes a system reset. During a POST, the unit checks system memory,
configuration, installed cards, compression hardware, and T1 connections.
If the start-up display indicates a failure in any part of the POST, an internal hardware failure
has occurred with the unit.
If no data is displayed on the VT100 interface, verify that the unit completes all of the
power-on self tests. Proceed as follows:
1Verify that the MAX unit and your terminal are set at the same speed.
2Locate the indicator light labeled Fault.
3Switch on the MAX unit.
Troubleshooting POST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Interpreting indicator lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Troubleshooting the No Logical Link status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Troubleshooting the AIM port interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
Troubleshooting a codec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Troubleshooting cable issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Displaying interface statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Using modems to perform administrative tasks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
Booting from a FAT-formatted PCMCIA card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17

1-2 MAXAdministrationGuide
Administering MAX Hardware
Interpreting indicator lights
Interpreting indicator lights
The MAX 6000, MAX 3000, and MAX 800 series each have a unique set of front panel
indicator and back-panel indicator lights that display information about modems, power
(including redundant power), fault-tolerance, data-link, and Alarm events.
MAX 6000
The MAX 6000 unit’s front-panel indicator lights indicate the status of the system, the PRI
interface, and the data transfer in active sessions. Figure 1-1 shows the location of the indicator
lights on the front panel of a MAX 6000 unit.
Figure 1-1. MAX 6000 front panel
Table 1-1 describes each indicator light located on the front panel of a MAX 6000 unit.
Table 1-1. MAX 6000 front-panel indicator lights
Light Description
Power On when the MAX 6000 unit’s power is on.
Fault On in one of two cases:
• Hardware self-test in progress.
• Hardware failure.
When a hardware self-test is in progress, the indicator light stays on. If any
type of hardware failure occurs, the indicator light flashes. If the failure is
isolated to an expansion card, the MAX 6000 unit might continue to function
without the expansion card.
Data On when calls are active.

Administering MAX Hardware
Interpreting indicator lights
MAX Administration Guide 1-3
The MAX 6000 unit’s front panel indicator lights convey information about the power supplies
and the status of the unit’s fans. Figure 1-2 shows the location of the indicator lights on the
front panel of a Redundant MAX 6000 unit.
Figure 1-2. Redundant MAX 6000 front panel
Table 1-2describes each indicator light on the front panel of a Redundant MAX 6000 unit.
Alarm On indicates a WAN alarm or a trunk out of service (during line loopback
diagnostics, for example). WAN alarms include Loss of Sync, Red Alarm,
Yellow Alarm, and All Ones (or AIS).
For more information about the Alarm indicator light, see“Troubleshooting a
Red Alarm” on page 5-2 and “Troubleshooting a blinking Alarm” on
page 5-4.
Table 1-2. Redundant MAX 6000 front panel lights
Light Description
Power On when the Redundant MAX power supply is on.
A Fail On only if one or more of the voltages from side A of the power supply
has failed (+12, +5, +3.3, -12, -5.)
Table 1-1. MAX 6000 front-panel indicator lights (continued)
Light Description

1-4 MAXAdministrationGuide
Administering MAX Hardware
Interpreting indicator lights
For more information, see “Troubleshooting a Red Alarm” on page 5-2 and “Troubleshooting
a blinking Alarm” on page 5-4.
The MAX 6000 unit’s back-panel indicator lights convey information about network traffic on
the unit’s Ethernet interface, packet collisions on the Ethernet network, full duplex operation
on the Ethernet network, 100BaseT (or 10BaseT) status, and the functional status of the
Ethernet interface. Figure 1-3 shows the MAX 6000 back-panel indicator lights, which display
the status of the Ethernet interface.
Figure 1-3. MAX 6000 back-panel indicator lights
Table 1-3 describes the MAX 6000 unit’s Ethernet interface indicator lights.
B Fail On only if one or more of the voltages from side B of the power supply
has failed (+12,+5, +3.3, -12, -5).
Fan On when the fans are functioning properly (if +12 Vdc from either A or
B is good). This indicator light goes off in the event of a fan failure.
Table 1-3. MAX 6000 back-panel indicator lights
Light Description
ACT (Activity) On when the MAX is detecting activity (network traffic) on its Ether-
net interface.
COL (Collisions) On when the MAX detects packet collisions on the Ethernet.
FDX On indicates full duplex on the Ethernet.
100BT On indicates 100BaseT operation. Off indicates 10BaseT operation.
LINK (Link integ-
rity) On when the Ethernet interface is functional.
Table 1-2. Redundant MAX 6000 front panel lights (continued)
Light Description
This manual suits for next models
3
Table of contents
Other Lucent Network Router manuals