Lynx R FR 5041 User manual

LYNXTechnik AG
Broadcast Television Equipment
© 2012 LYNX Technik AG all rights reserved
®
Reference Manual
R FR 5041
Series 5000 1RU 19” Rack Frame with Power Supply
(Suitable for up to four Series 5000 Modules)
Revision 1.3 –February 2012
Information in this document is subject to change without notice. No part of this document may be reproduced or
transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of
LYNX Technik AG.
LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights
covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this
document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik
AG or any of its affiliates.
LYNX Technik AG
Brunnenweg 3
D 64331 Weiterstadt
Germany
www.lynx-technik.com

R FR 5041 Reference Manual. Rev 1.3
Page 2 of 34
Contents
Contents
...............................................................................................................2
Warranty ...............................................................................................................4
Regulatory information ........................................................................................5
Europe........................................................................................................................................ 5
Declaration of Conformity ....................................................................................................... 5
USA............................................................................................................................................. 5
FCC 47 Part 15....................................................................................................................... 5
WARNING..............................................................................................................6
WARNUNG! ...........................................................................................................6
ESD Warning.............................................................................................................................. 7
Getting Started.....................................................................................................8
Packaging .................................................................................................................................. 8
Product Description.................................................................................................................. 8
Installation Instructions ......................................................................................9
Installations-Anweisung.......................................................................................9
Power Supply......................................................................................................10
Power Supply Alarm LED....................................................................................................... 10
Rack Controller ..................................................................................................11
Controller LED Indication....................................................................................................... 11
Module Installation ............................................................................................12
Rack Connections ..............................................................................................13
Rear Termination Panel.......................................................................................................... 13
AC Input and Fuses.............................................................................................................. 13
Rack Reference (Sync Connector)....................................................................................... 14
Redundant Power Input........................................................................................................ 14
Alarm Connection (Terminal Strip) ....................................................................................... 14
Alarm Function...................................................................................................................... 14
LAN Connection (Remote Control)....................................................................................... 15
Hot Swapping .....................................................................................................15
Power Supplies........................................................................................................................ 15
Power Supply Failure............................................................................................................ 15
CardModules............................................................................................................................ 15
System Cooling and Fans...................................................................................16
Fan Replacement..................................................................................................................... 16
Network Configuration .......................................................................................17
The Network Connection Manager........................................................................................ 17

R FR 5041 Reference Manual. Rev 1.3
Page 3 of 34
Configure IP Address.............................................................................................................. 19
Network Attaching the RFR 5041........................................................................................... 20
LYNX Desktop Controller Software ...................................................................21
System Requirements............................................................................................................. 21
Software Installation ............................................................................................................... 21
Starting the Controller Application ....................................................................................... 23
Software Updates ................................................................................................................. 23
Software Operation ............................................................................................24
Control System Layout.......................................................................................24
Device List ............................................................................................................................... 25
User Defined Device List ...................................................................................................... 25
Module Properties................................................................................................................... 27
New Control Window ............................................................................................................ 27
Module Title Area .................................................................................................................... 28
Locate Function .................................................................................................................... 28
Control Tabs ............................................................................................................................ 28
Power Supply Tab................................................................................................................. 28
Settings Tab.......................................................................................................................... 29
HotSync Backup...................................................................................................................... 29
Switching on HotSync........................................................................................................... 30
Options Tab .......................................................................................................................... 31
Events Tab............................................................................................................................ 32
Error Logging Area ................................................................................................................. 32
Service ...............................................................................................................34
Technical Support................................................................................................................... 34
Contact Information ...........................................................................................34

R FR 5041 Reference Manual. Rev 1.3
Page 4 of 34
Warranty
LYNX Technik AG warrants that the product will be free from defects in materials
and workmanship for a period of three (3) years from the date of shipment. If this
product proves defective during the warranty period, LYNX Technik AG at its
option will either repair the defective product without charge for parts and labor,
or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, customer must notify LYNX
Technik of the defect before expiration of the warranty period and make suitable
arrangements for the performance of service. Customer shall be responsible for
packaging and shipping the defective product to the service center designated by
LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the
return of the product to the customer if the shipment is within the country which
the LYNX Technik service center is located. Customer shall be responsible for
payment of all shipping charges, duties, taxes and any other charges for
products returned to any other locations.
This warranty shall not apply to any defect, failure, or damage caused by
improper use or improper or inadequate maintenance and care. LYNX Technik
shall not be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than LYNX Technik representatives to
install, repair or service the product; b) to repair damage resulting from improper
use or connection to incompatible equipment; c) to repair any damage or
malfunction caused by the use of non LYNX Technik supplies; or d) to service a
product which has been modified or integrated with other products when the
effect of such modification or integration increases the time or difficulty servicing
the product.
THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS
PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED.
LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX
TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE
PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE
CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS
VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTIAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF
WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF
THE POSSIBILITY OF SUCH DAMAGES.

R FR 5041 Reference Manual. Rev 1.3
Page 5 of 34
Regulatory information
Europe
Declaration of Conformity
USA
FCC 47 Part 15
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
We LYNX Technik AG
Brunnenweg 3
D-64331 Weiterstadt
Germany
Declare under our sole responsibility that the product
TYPE: R FR 5041
To which this declaration relates is in conformity with the following
standards (environments E1-E3):
EN 55103-1 /1996
EN 55103-2 /1996
EN 60950-1 /2006
Following the provisions of 89/336/EEC and 73/23/EEC directives.
Winfried Deckelmann
Weiterstadt, February 2012
Place and date of issue Legal Signature

R FR 5041 Reference Manual. Rev 1.3
Page 6 of 34
WARNING
Electrical supplies in excess of 50 (fifty) volts peak value are potentially hazardous or lethal. AC
supplies between 100 and 250 peak volts exist within the rack frame chassis when connected to
AC power. Only qualified personnel should service the rack frame assembly.
Removal of technical earth may render the equipment dangerous and intentional removal is
prohibited.
This unit has to be separated from mains by disconnecting the power supply cords.
This unit may have two power supplies and two power supply cords. Disconnect all power supply
cords before servicing to avoid electric shock.
DOUBLE POLE / NEUTRAL FUSING
After operation of the fuse, parts of equipment that remain energized might represent a hazard
during servicing.
For continued protection against risk of fire, replace only with same type and rating of fuse.
F1/F2: T2AH250V
Replacement AC fuses must be of the specified type and rating: F1/F2 = T2AH250V
The use of repaired fuses or shorting links has to be avoided.
WARNUNG! WARNING! CAUTION!
WARNUNG!
Wenn das Gerät an das Wechselstromnetz angeschlossen ist, treten innerhalb des Gerätes
Wechselspannungen zwischen 100 und 250 V auf, die potentiell gefährlich oder tödlich sein
können. Deshalb darf eine Reparatur und Instandhaltung nur von qualifiziertem Personal
durchgeführt werden.
Das Entfernen des Schutzleiters kann das Gerät in einen gefährlichen Zustand bringen,
vorsätzliches Entfernen des Schutzleiters ist verboten.
Das Gerät ist durch Abziehen beider Netzstecker vom Netz zu trennen.
Das Gerät kann 2 Netzgeräte mit 2 Netzkabeln haben. Vor Servicearbeiten müssen alle
Netzkabel abgezogen werden, um elektrischen Schlag zu vermeiden.
Die Netzzuführung ist 2-polig abgesichert. Nach Ausfall einer Sicherung können Teile der
Schaltung weiter unter Spannung bleiben und bei Servicearbeiten zu Gefahren führen.
Vor Servicearbeiten Stromversorgung unterbrechen und Teile vor Berührung prüfen.
Um Schutz gegen Feuer aufrechtzuerhalten, sind bei Sicherungswechsel nur Sicherungen des
gleichen Typs mit gleichen Daten zulässig. F1/F2 = T2AH250V

R FR 5041 Reference Manual. Rev 1.3
Page 7 of 34
ESD Warning
The internal electronics parts of this product are static sensitive. Please use caution and
use preventative measures to prevent static discharge or damage could result to
modules.
Electrostatic discharge (ESD) damage occurs when electronic assemblies or the
components are improperly handled and can result in complete or intermittent failure.
Do not handle the module unless using an ESD-preventative wrist strap and ensure that
it makes good skin contact. Connect the strap to any solid grounding source such as any
exposed metal on the rack chassis or any other unpainted metal surface.
Caution
Periodically check the resistance value of the antistatic strap. The measurement should
be between 1 and 10 Megohms.

R FR 5041 Reference Manual. Rev 1.3
Page 8 of 34
Getting Started
Packaging
The shipping carton and packaging materials provide protection for the rack frame during
transit. Please retain the shipping cartons in case subsequent shipping of the product
becomes necessary.
Product Description
The R FR 5041 is a high quality compact 1 RU high 19 inch rack frame enclosure for
LYNX Series 5000 CardModules, designed primarily for broadcast and professional
applications.
The rack frame can accept a maximum of 4 Series 5000 CardModules (any
combination*). Primary power supply and a fully integrated LAN port are also included
(LAN port is for remote control using the included LYNX Desktop Controller Software)
All CardModules and the Primary Power supply are installed and removed from the front.
Module rear connection panels are supplied with each CardModule and are mounted on
the rear of the rack as required. All CardModules and the power supply are hot
swappable.
*Note. Some Card Modules require a larger double height backplane (for I/O reasons)
which will occupy two pack slots. Please refer to individual module specifications for
details. These are typically the modules which currently have a double width backplane
when used with the RFR 5012 2RU rack frame.
The R FR 5041 features an integrated termination panel with connections for AC power
input, remote alarming, LAN control and a rack reference (sync). An external + 12VDC
power input connection is provided for optional external redundant power backup using a
brick power supply (Option R PS 5000)
The Rack frame has a hinged front cover providing easy access to all installed modules
and power supply which are hot swappable.
All electrical contacts inside the RFR 5041, CardModules and power supplies are gold
plated ensuring maximum reliability and protection from corrosion. Modules are
mechanically secured in place and will not shake loose with vibration (ideal for mobile
applications).
The R FR 5041 is one of the primary building blocks in the LYNX Series 5000
CardModule product line providing high quality, modularity and flexibility in a very small
form factor.

R FR 5041 Reference Manual. Rev 1.3
Page 9 of 34
!
!
!
!
!
!
Installation Instructions
The RFR 5041 is intended for operation in broadcast environments. The operation of the
equipment in environments which could produce excessive dust, moisture or extreme
temperatures requires special accommodation, such as:
Dust filters
Air conditioning
Avoidance of condensation
CAUTION!
The power cords must meet the safety requirements of the country where the rack
frame is used and has to be approved in this country, e.g.
CE-Mark in Europe
UL-listed in USA
CSA certified in Canada
CAUTION!
The power supply cords are used to disconnect the R FR 5041 from the AC mains
supply, ensure that the AC socket-outlets are located/installed near the equipment and
are easily accessible.
CAUTION!
The rack frame chassis is CLASS I EQUIPMENT. Before initial operation ensure that
protective earth is connected to the facility wiring and zero potential is established.
The functional earth connection at the rear termination panel is connected internally to
protective earth. If necessary, it may be used for potential equalization to other units.
Installations-Anweisung
Das Gerät R FR 5041 ist für Anwendungen in Fernsehstudios vorgesehen. Der Einsatz in
erhöhter staubiger und feuchter Umgebung oder außergewöhnlichen Temperaturen erfordert
besondere Maßnahmen wie
Klimatisierung
Staubfilter
Vermeiden von Kondenswasser.
ACHTUNG!
Die Netzkabel müssen den Sicherheits-Anforderungen in dem Land entsprechen in dem
das Gerät verwendet werden soll und in dem Land zugelassen sein, z.B.
CE-Zeichen in Europa
UL-gelistet in USA
CSA-Zulassung in Kanada
ACHTUNG!
Die Netzkabel dienen zur Trennung des Geräts vom Netz. Es ist sicherzustellen, dass
die Steckdosen für den Netzanschluss in der Nähe des Gerätes angebracht und zum
Trennen leicht zugänglich sind.
ACHTUNG!
Das Gerät ist nach der Schutzklasse I aufgebaut. Vor der ersten Inbetriebnahme muss
sichergestellt werden, dass der Schutzleiter mit dem zentralen Schutzleiter des
Gebäudes verbunden ist und spannungsfrei ist.
Der Erdanschlussbolzen an der Netzanschlussrückseite ist intern mit dem Schutzleiter
verbunden. Falls erforderlich, kann er für den Potentialausgleich mit anderen Geräten
verwendet werden.

R FR 5041 Reference Manual. Rev 1.3
Page 10 of 34
The rack frame is designed to fit into industry standard 19” equipment housing. The chassis will
occupy 1 RU of rack space. Opening the front cover will allow access to the 19” rack mounting
holes.
Airflow is from side to side, therefore care needs to be taken not to restrict the airflow through the
system. There are no ventilation holes in the top of bottom of the chassis, and no additional rack
space is required to accommodate vertical airflow or ventilation.
Power Supply
The R FR 5041 includes the primary power supply (an optional external power supply
(RPS 5000) can be used for redundancy which will provide a +12VDC input). Should a
power fault develop, the errors are alarmed in the following ways:
Via the LED located on the front of the Power Supply (visible through front cover)
Via a GPO alarm connection to the Termination Panel
Via the LYNX Desktop Controller connected to the LAN port (if used)
If the external redundant power supply (Option RPS 5000) is used then the system will
switch supplies automatically in the event of primary supply failure; with no interruption to
system operation.
The primary power supply is installed and removed from the front of the rack. The supply
locks itself firmly in place. The power supply can be released by pushing up the locking
clip and pulling on the handle above (see below)
Power Supply Alarm LED
LED Status
Description
GREEN
Normal Operation
YELLOW
Warning –High Temperature (over 55ºC)
RED FLASHING
Warning –Over Temperature (over 70ºC)
RED (Continuous)
Voltage Out of Range
OFF
Supply Failure (or AC power disconnected / AC fuses blown)
Alarm LED
Locking Clip
Handle

R FR 5041 Reference Manual. Rev 1.3
Page 11 of 34
Rack Controller
The RFR 5041 is supplied with a integrated LAN rack controller, which when used with
the included LYNX Desktop Controller software application provides remote control,
status monitoring and alarm logging functionality. The 1RU rack can also be fully
integrated into larger systems which are using the LYNX Desktop Controller for
centralized control of a number of LYNX systems.
The rack controller is a fixed position in the rack, located above one of the available card
slots (the lower area of this slot can still be used for a LYNX module, no capacity is
removed). The controller can be removed if required for maintenance, simply slide
forward to unplug the module. Four LEDs are provided on the module edge which are
used to indicate status.
Rack Controller Shown above Series 5000 Module in Chassis
*Note. This connector is for use by LYNX Service personnel and is used for firmware updates to
the controller. Specialized programming equipment is required; do not attempt any connection to
this port.
Controller LED Indication
The controller status LEDs are used to indicate various conditions:
LED
Name
Color
Description
1
HotSync Write
green
HotSync switched ON
yellow
HotSync currently writing to device
off
HotSync switched OFF
2
HotSync Read
green
HotSync switched ON
yellow
HotSync currently reading from device
off
HotSync switched OFF
3
Network
green
network connected OK
yellow
DHCP mode active but not satisfied
off
network connection not active
4
Rack Fans
green
all rack fans OK
3 yellow flashes
saving current settings to local memory
red
rack fan failure
all LEDs flashing yellow:
LOCATE mode enabled by remote-interface
(for physical board identification)
Status LEDs (1..4)
Rack Controller
Service Connection*

R FR 5041 Reference Manual. Rev 1.3
Page 12 of 34
Module Installation
The R FR 5041 can accept 4 standard Series 5000 CardModules. There is no restriction
of type of module or function; any combination can be mixed as required. Some of the
more complex modules will require a double height backplane (for I/O reasons) and these
will occupy two slots.
If you ordered the R FR 5041 complete with modules then the chassis will be supplied
with the modules pre-installed and tested and the system is ready to be used. If you are
adding modules to the chassis yourself, then please follow the instructions below.
1. Unpack the CardModule from its shipping carton. The module is supplied with the
required backplane assembly. Please take static precautions when handling the
modules, as the modules are extremely sensitive to ESD.
2. Locate an empty slot in the R FR 5041 and remove the cover plate from the rear of
the rack in the corresponding position (2 screws).
3. Install the backplane onto the rack using the 2 screws provided.
4. Slide the CardModule into the corresponding rack slot from the front of the rack*, do
this slowly and ease into the rear connector. If this is difficult or requires excessive
force then please stop and check the rear panel installation. The module should be
fairly easy to slide into the rear connector.
*Note. Each module slot is equipped with a mechanical retainer which is used to prevent
the modules becoming unplugged in situations involving a lot of vibration (i.e. Mobile
applications). Slide the retainer up with your finger to access the module guide slot.
When the module is all the way in; slide the retainer back down to lock the module in
position. See below:
Slide retainer up to insert module, and down to lock into place

R FR 5041 Reference Manual. Rev 1.3
Page 13 of 34
!
Rack Connections
Rear Termination Panel
The R FR 5041 has an integral termination panel on the rear of the rack for system
connections.
AC Input and Fuses
The AC input is auto sensing 100-250V 50/60Hz (1.8A nominal) and is located on the
rear of the chassis. Use a standard IEC power cord with a C13 connector for the power
connection. The fuses are located below the AC power input (see below). The system is
double pole / neutral fused so there are two fuses. The fuses are removed by pushing
down on the plastic tab and sliding the fuse carriage out. Insert new fuses and slide the
carriage back in all the way until the tab “clicks” and locks the fuse carriage in place.
Caution
Please remove power before attempting to exchange power fuses. Only replace
the fuse with a correctly rated replacement. (T2AH250V) For safety DO NOT
physically disconnect or isolate the rack from earth for any reason.
Fuse (x2) = T2AH250V
Push tab down to remove
Fuse carriage removed

R FR 5041 Reference Manual. Rev 1.3
Page 14 of 34
Rack Reference (Sync Connector)
The chassis has a single reference input. This is for the connection of a “common rack
reference” which is distributed to each of the available rack slots for any installed
modules which require an external reference input.
The connection supports all analog SDTV and HDTV video sync standards (Auto-detect),
bi-level or tri-level.
Redundant Power Input
A connector is provided for the connection of an external 12VDC power input, which is
used for redundant protection. LYNX provides an optional RPS 5000 brick power supply
for use as an external redundant supply. If providing your own DC power input; then
please ensure a clean feed of +12VDC @ 8A (+/- 5%). The mating power connector is
Molex MiniFit Series 5557 (part # 0039012040), crimp contacts Molex Series 5556 (part #
0039000078). Connections are shown below.
External DC Input Connections
(View looking into connector)
Alarm Connection (Terminal Strip)
A terminal strip is provided for the connection to external alarm systems
The connections are designated as follows:
1
2
3
4
5
6
GPI B
GPI A
Alarm
Minor B
Alarm
Minor A
Alarm
Major B
Alarm
Major A
Function and connection information is described below.
Alarm Function
The user can assign the triggers for the alarm conditions using the LYNX Desktop
Controller Software Application.
The terminal strip has a GPI input (for future use), and two alarm outputs. These are
contact closures and allow for the connection of external monitoring equipment or alarm
systems.
There are two alarms Minor Alarm and Major Alarm, these are configured using the
LYNX Desktop Controller. Simply assign the alarms to the available selections.
+12V
GND
1
2
3
4

R FR 5041 Reference Manual. Rev 1.3
Page 15 of 34
When the alarm is triggered, a contact closure is made between the A and B
connections, for example a minor alarm will provide a contact closure between terminal
strip connector 3and 4
Note. The default selection is “None” as shown above. Once the required settings have
been made they are stored in the rack controller and will survive power cycles.
LAN Connection (Remote Control)
The R FR 5041 is equipped with a rack controller and when using the LAN connection
remote control, status monitoring and alarm logging is possible when used with the
supplied LYNX Desktop Controller Software application.
The LAN connection is a standard TCP/IP connection at speeds up to 100MBit /
(10/100MBit) Full Duplex
Please refer to the Network Connection section of this manual for more details on the
LAN port configuration and use.
Hot Swapping
Power Supplies
All Series 5000 CardModules and Power Supplies are fully hot swappable.
Power Supply Failure
A failure in the Primary power supply will automatically trigger the use of the redundant
supply (if fitted) and will trigger the following alarm conditions / indications (requires
controller option).
Reported fault on the monitoring system
Alarm GPO trigger on the alarm connector (see Alarm Connections section)
Once identified, the defective supply can be removed and replaced with power connected
with no interruption to the operation of the CardModules [if the redundant supply is
installed].
CardModules
If a CardModule fails the error will be reported in the monitoring system (LYNX desktop
Controller Application) and via the front side alarm LED. Alarm function is module
dependant so please refer to the CardModule manual for failure conditions and
indications. The defective CardModule can be removed and replaced with an identical
replacement without removing power from the frame.

R FR 5041 Reference Manual. Rev 1.3
Page 16 of 34
System Cooling and Fans
The chassis has integrated cooling fans and the airflow is from one side to the other
through the ventilation holes provided.
There is no ventilating through the top and bottom covers, so no space needs to be
allowed above and below the rack in a system installation.
Fan Replacement
The fans are monitored and alarmed in the control system; if a fan fails please follow the
instructions below to exchange fans.
The two fans are located on the right hand side of the chassis, each secured in place
using two screws.
1. Disconnect all cables and remove the chassis from the 19” rack frame.
2. Remove the top cover, screw locations to remove cover are shown below
3. Remove the power supply. To exchange the rear fan it will also be necessary to
move the power supply mounting bracket to one side (see below). Two screws in the
bottom of the chassis should be loosened to allow this bracket to be moved over.
Fan 1
Fan 2
Power Supply Bracket
Fan
Fan

R FR 5041 Reference Manual. Rev 1.3
Page 17 of 34
4. Remove the 2 screws from the fans to take them from out of the chassis, unplug the
fan cables from the rear PCB
5. Insert new fans (ensure correct orientation) and plug leads into PCB.
6. Secure the power supply bracket and re-assemble chassis.
Note. Please contact LYNX Technik for replacement fan assemblies
Network Configuration
The R FR 5041 includes a LAN controller which when used in conjunction with the
supplied LYNX Desktop Controller software package will facilitate remote control, status
monitoring and error logging for all LYNX Hardware.
Connect the R FR 5041 to your network using the LAN port provided. The LEDs below
the LAN connector on the rack frame will show some network activity if connected
properly.
Note: The next steps require that you have already installed the LYNX Desktop Controller
on a client P. If this should not be the case please install the software. Refer to the software
installation instructions section of this manual.
Most configuration below have to be done by the network administrator. The default login and
default password for the administrator in the LYNX control system is:
- Login: admin
- Password: lynx$admin
The Network Connection Manager
Open the LYNX Desktop Controller application and select Tools>Network Connection
Management or click on the “Connect”button. (See below)

R FR 5041 Reference Manual. Rev 1.3
Page 18 of 34
This will open the Network Connection Management Dialog shown below:
There are three tabs, one is for Serial connections (which are not applicable to the R FR
5041) and the other two are for network configuration. Please make sure the “simulation”
check box is unchecked
Note: Simulation mode will simulate a large LYNX installation and populate the system
with an array of simulated hardware for demonstration and training purposes. While this
will not impact the operation of any actual hardware connected, it is recommended to have
this turned off to avoid confusion.
Select the Network Connections Editor Tab. This dialog is shown below and comprises
of two main sections. The left hand side shows the current network configuration and the
right hand side shows the LYNX hardware which has been detected.
The LYNX software will automatically scan the network for any connected LYNX
hardware. All available devices will be displayed on the right hand side.
The R FR 5041 is shipped with a factory default IP address of 192.168.1.162. While
it’s certainly possible to use this IP address, it’s highly recommended to change this to
something suitable for your network. This can be set to a fixed static IP address or
automatically using DHCP if your network supports this.
If the R FR 5041 is not detected, then please check the network connection and network
activity using the LEDs on the connector. You can also manually enter the above IP
address and search specifically for this device.
In the example below you can see the LYNX GUI Computer in the current network
infrastructure with the detected R FR 5041 listed as an available network component with
the factory default IP address.

R FR 5041 Reference Manual. Rev 1.3
Page 19 of 34
Configure IP Address
At this stage it’s recommended you configure the IP address of the R FR 5041 to
something suitable for your particular network, or configure DHCP. To do this click the
Network Component Configuration tab, see below:

R FR 5041 Reference Manual. Rev 1.3
Page 20 of 34
When the device is selected you can manually change the IP address, or configure
dynamic IP (DHCP). To activate the text fields just click on the device.
Please contact your network administrator if you are not sure what static IP address to
use, or to get the required information to configure DHCP.
Setting IP Addresses
To set a dedicated IP address for the R FR 5041 just type in the required information into
the respective text fields in the Network Connection Management window shown above.
Note: DHCP mode has to be deactivated in the checkbox “Dynamic IP (DHCP)”
Activation of DHCP Mode
If the controller is installed in a network environment where the IP addresses are
allocated automatically (DHCP) the RFR5003/4 can be set to DHCP mode. Simply
activate the checkbox “Dynamic IP (DHCP)” in the Network Connection Management
window shown above.
Note: If in DHCP mode, the RFR 5003/4 will wait approx 30sec for a DHCP capable
server to allocate a IP address. If no address is allocated the default address will be used.
Note. It is possible for devices to have the same IP address and appear in this list (with
unique MAC addresses). This will cause a network error warning that duplicate IP
addresses are being used. Please ensure no duplicate IP addresses are present.
Network Attaching the R FR 5041
Once the IP address has been configured it is now necessary to move (connect) the R
FR 5041 into the network infrastructure so we can control and communicate with the
device. We do this by “attaching” the R FR 5041 to a control device (i.e. LYNX GUI or R
CT 5031)
To attach the R FR 5041 switch back to the “Network Connections Editor Tab”. Select
EDIT mode and drag&drop the R FR 5041 and place it under the LYNX GUI entry to
attach the R FR 5041 to the control system PC. See Below.
Note. In larger installations
with additional LYNX
hardware present on the
network there may be RCT
5031 Rack Controllers
detected. It’s possible to
“attach” the R FR 5041 to an
existing RCT 5031 Controller
and still maintain full control
and visibility of the R FR 5041
in the control system. To
which control device to attach
the R FR 5041 is determined
by your installation and
control preferences and
network topology.
This drag and drop function has “attached” the R FR 5041 to the LYNX GUI, so it will now
be visible and accessible using the LYNX Desktop Controller.
Table of contents
Other Lynx Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Panasonic
Panasonic i-PRO WV-Q121B operating instructions

MasterCraft
MasterCraft 046-8652-2 instruction manual

PROAIM
PROAIM TP-FWBS-01 Assembly manual

OE electrics
OE electrics INSTR1294 quick start guide

on stage
on stage Deluxe Keyboard Tier KSA8500 instructions

Vantage Point Products
Vantage Point Products U50 Assembly instructions