US SKU#: MSF013
UPC#: 810008261514
ITF-14#: 10810008261511

©2020 MAGMATIC EFFECTS all rights reserved. Information, specications, diagrams, images, and
instructions herein are subject to change without notice. MAGMATIC EFFECTS logo and identifying
product names and numbers herein are trademarks of MAGMATIC EFFECTS. Copyright protection
claimed includes all forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this document may be
trademarks or registered trademarks of their respective companies and are hereby acknowledged.
All non-MAGMATIC brands and product names are trademarks or registered trademarks of their
respective companies.
MAGMATIC EFFECTS and all aliated companies hereby disclaim any and all liabilities for property,
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as
a result of the improper, unsafe, insucient and negligent assembly, installation, rigging, and opera-
tion of this product.
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version
of this document may be available online.
Please check www.elationlighting.com for the latest revision/update of
this manual before beginning installation and/or programming.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | sales@magmaticeects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
Elation Professional Mexico | AC Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
2
Date Document
Version
Software
Version
DMX Channel Mode Notes
11/17/20 1 1.0 1 / 2 / 4 channels Initial Release

CONTENTS
3
General Information 4
Limited Warranty (USA Only) 5
Warranty Returns (USA Only) 6
Safety Guidelines 7
Maintenance Guidelines 9
Overview 10
Installation Instructions 11
Control Panel 13
System Menu 14
Preset Mode 16
DMX Channel Functions & Values 17
Dimensional Drawings 18
Specifications 19

INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting
to operate this device. These instructions contain important safety and use information.
This product is intended to be used by professionally trained personnel only and is not suitable
for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Care-
fully check the shipping carton for damage that may have occurred during shipping. If the carton is
damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event that damage has been found or parts are missing,
please contact our customer support team for further instructions. Please do not return this device to
your dealer without rst contacting customer support. Please do not discard the shipping carton in the
trash. Please recycle whenever possible.
BOX CONTENTS
Twist-Lock Power Cable (x1)
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments, or suggestions.
ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | sales@magmaticeects.com
ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
REPLACEMENT PARTS: Please visit parts.elationlighting.com
GENERAL INFORMATION
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAM-
AGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF
SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S
WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
IMPORTANT NOTICE!
4

A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic products to be free of
manufacturing defects in material and workmanship for a period of two years (730 days) from the
original date of purchase. This warranty excludes discharge lamps and all product accessories. This
warranty shall be valid only if the product is purchased within the United States of America, includ-
ing possessions and territories. It is the owner’s responsibility to establish the date and place of pur-
chase by acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Magmatic Effects factory. All shipping charges
must be pre-paid. If the requested repairs or service (including parts replacement) are within the
terms of this warranty, Magmatic Effects will pay return shipping charges only to a designated point
within the United States. If any product is sent, it must be shipped in its original package and pack-
aging material. No accessories should be shipped with the product. If any accessories are shipped
with the product, Magmatic Effects shall have no liability what so ever for loss and/or or damage to
any such accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are altered or removed; if the
product is modified in any manner which Magmatic Effects concludes, after inspection, affects
the reliability of the product; if the product has been repaired or serviced by anyone other than the
Magmatic Effects factory unless prior written authorization was issued to purchaser by Magmatic
Effects; if the product is damaged because not properly maintained as set forth in the product
instructions, guidelines and/or user manual.
D. This is not a service contract, and this warranty does not include any maintenance, cleaning or
periodic check-up. During the periods as specified above, Magmatic Effects will replace defective
parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of
defects in material or workmanship. The sole responsibility of Magmatic Effects under this warranty
shall be limited to the repair of the product, or replacement thereof, including parts, at the sole dis-
cretion of Magmatic Effects. All products covered by this warranty were manufactured after January
1, 1990, and bear identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or performance improve-
ments upon its products without any obligation to include these changes in any products theretofore
manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory sup-
plied with the products described above. Except to the extent prohibited by applicable law, all
implied warranties made by Magmatic Effects in connection with this product, including warranties
of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no
warranties, whether expressed or implied, including warranties of merchantability or fitness, shall
apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy
shall be such repair or replacement as is expressly provided above; and under no circumstances
shall Magmatic Effects be liable for any loss and/or damage, direct and/or consequential, arising out
of the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Magmatic Effects products and super-
sedes all prior warranties and written descriptions of warranty terms and conditions heretofore pub-
lished.
LIMITED WARRANTY (USA ONLY)
5

WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Material Authorization (RMA) number must first be obtained
from MAGMATIC. It is the Customer’s responsibility to provide product proof of purchase and serial
number by acceptable evidence such as an invoice copy or an approved MAGMATIC Extended
Warranty Certificate (“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or EWC and any rel-
evant maintenance records may be cause for denial of warranty service.
Products returned for warranty service must be sent without any accessories (i.e., power, data, and
safety cables, brackets, clamps, rigging hardware, frost filters, gel frames, barn doors, lenses, hoses,
nozzles, rack mounting hardware, etc.), must be boxed using the original and/or suitable packag-
ing materials (double-box and foam) that provides ample product protection for ground and/or air
freight transit, and must be shipped freight pre-paid and insured to MAGMATIC in Los Angeles, CA
or a MAGMATIC Authorized Service Center. The RMA number must be clearly written on the outside
of the return box, and a brief description of the problem and the RMA number must be documented
and included in the box.
Products returned for warranty service without an RMA number clearly marked on the outside of the
package will be refused and returned to the shipper at the Customer’s expense. Products returned
for warranty service, which are received damaged due to inadequate and/or improper packaging
and/or due to damage caused by the shipping carrier, may incur additional repair charges before
warranty service begins and/or may void this warranty. If any product accessories (included and/
or optional) are shipped with the product, MAGMATIC and/or the MAGMATIC Authorized Service
Center shall have no liability what so ever for the loss and/or damage to any such accessories, nor
the safe return thereof. If the requested warranty repairs or service (including parts replacement) are
within the terms of this warranty, MAGMATIC will pay return ground transportation shipping charges
to a single designated point within the United States.
6

SAFETY GUIDELINES
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is
important to follow all instructions and guidelines in this manual. Magmatic Effects is not responsible
for injury and/or damages resulting from the misuse of this fixture due to the disregard of the infor-
mation printed in this manual. Only qualified and/or certified personnel should perform installation of
this fixture and only the original parts included with this fixture should be used for installation. Any
modifications to the fixture and/or the included mounting hardware will void the original manufac-
turer’s warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED.
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO
NOT ATTEMPT ANY REPAIRS YOURSELF. DOING SO WILL VOID YOUR
MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS
TO THIS DEVICE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND
ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG THIS UNIT INTO A DIMMER PACK
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
FIXTURE IS PROTECTED AGAINST INTRUSION BY SOLID OBJECTS LARGER
THAN 1mm (SUCH AS MOST WIRES AND SCREWS). WATER SPLASHING
AGAINST THE ENCLOSURE FROM ANY DIRECTION SHALL HAVE NO HARMFUL
EFFECT.
7
IP44

• DO NOT TOUCH the device housing during operation. Turn OFF the power and
allow approximately 15 minutes for the device to cool down before servicing.
• DO NOT shake the device, and avoid brute force when installing and/or operating.
• DO NOT operate device if the power cord is frayed, crimped, damaged and/or if
any of the power cord connectors are damaged and do not insert into the device
securely and with ease. NEVER force a power cord connector into the device. If
the power cord or any of its connectors are damaged, replace it immediately with
a new one of similar power rating.
• DO NOT block any air ventilation slots.
• All fan and air inlets must remain clean and free of dust and debris.
• Allow approx. 6” (15cm) between fixture and other devices or a wall for proper
cooling.
• When installing the device in a suspended environment, always use appropriately
rated hardware, and always secure the device with an appropriately rated safety
cable.
• Always disconnect device from main power source before performing any type of
service and/or cleaning procedure. Only handle the power cord by the plug end,
and NEVER pull out the plug by tugging the wire portion of the cord.
• Consistent operational breaks will ensure device will function properly for many
years.
• ONLY use the original packaging and materials to transport the fixture for service.
SAFETY GUIDELINES
8

MAINTENANCE GUIDELINES
9
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function and an extended life. The frequency
of cleaning depends on the environment in which the device operates: damp, smoky, or particularly
dirty environments can cause greater accumulation of dirt on the device. Clean the external surface
periodically with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are
no user serviceable parts inside this device, please refer all other service issues to an authorized
MAGMATIC service technician. Should you need any spare parts, please order genuine parts from
your local MAGMATIC dealer.
Please refer to the following points during routine inspections:
• A detailed electrical check by an approved electrical engineer every three months, to make sure
the circuit contacts are in good condition in order to prevent overheating.
• Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out
during normal operation, resulting in damage or injury as larger parts could fall.
• Check for any deformations on the housing, rigging hardware, and rigging points (ceiling, sus-
pension, trussing). Deformations in the housing could allow for dust or liquids to enter into the
fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously
injure a person(s).
• Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.

OVERVIEW
10
1. Mounting Yoke
2. Touch Screen Display
3. Mounting Yoke Adjustment Knob (x2)
4. Fan Grille (x2)
5. Optional Module Installation Point* (x2)
6. Wired Remote Port
7. Breaker
8. Power In
9. DMX Out
10.Power Out
11.DMX In
12.Safety Cable Loop
*device shown with optional equipment installed; actual
equipment of your device may vary, and module installation
points may be blanked out if not in use.

FLAMMABLE MATERIAL WARNING
Keep xture a minimum of 5 feet (1.5 meters) away from ammable materials and/or
pyrotechnics.
ELECTRICAL CONNECTIONS
A qualied electrician should be used for all electrical connections and/or installations.
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
INSTALLATION INSTRUCTIONS
11
Device MUST be installed following all local, national, and country commercial electrical and con-
struction codes and regulations.
Before rigging/mounting a single device or multiple interconnected devices for custom matrix de-
signs to any metal truss/structure or placing the device(s) on any surface, a professional equipment
installer MUST be consulted to determine if the metal truss/structure or surface is properly certied
to safely hold the combined weight of the device(s), clamps, cables, and accessories.
Maximum ambient operating temperature is 104°F (40°C).
Do not operate this device when ambient temperature exceeds this limit.
Device(s) should be installed outside walking paths, seating areas, and areas where unauthorized
personnel might reach the device by hand.
NEVER stand directly below the device(s) when rigging, removing, or servicing.
Allow approximately 15 minutes for the device to cool down before servicing.
Overhead installation must always be secured with a secondary safety attachment, such as
an appropriately rated safety cable (not included) that meets all local, national, and country
codes and regulations.

INSTALLATION INSTRUCTIONS
12
CLAMP INSTALLATION
This device features a mounting yoke with integrated clamp attachment points, as well as a safety
cable loop located near the fan grille on the cable connection side of the device (see the illustra-
tion below). When mounting this xture to truss, be sure to secure appropriately rated clamps (not
included) to the mounting yoke, and attach a separate SAFETY CABLE of the appropriate rating to
the safety cable loop.
SAFETY CABLE
ALWAYS ATTACH A SAFETY
CABLE WHEN INSTALLING THIS
DEVICE IN A SUSPENDED EN-
VIRONMENT TO ENSURE THAT
THE DEVICE WILL NOT FALL IN
THE EVENT THAT THE CLAMP
FAILS.
RIGGING
Overhead rigging requires extensive experience, including but not limited to: calculating working
load limits, understanding the installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualications, do not attempt the installation
yourself. Improper installation can result in bodily injury.

CONTROL PANEL
This device includes a system menu with an easy to navigate touch screen control panel where all
necessary settings and adjustments can be made. When rst powering on the device, the main
menu will be displayed.
13
To proceed, press the main menu icon that you would like to access. Use the ENTER button to ac-
cess sub menus and use the UP and DOWN buttons to make adjustments. Press the ENTER button
to conrm your adjustments. You may exit the main menu at any time without making any adjust-
ments by pressing the BACK/EXIT button.
When using the Timer function, a dierent set of Timer Icons will be displayed. Press the SETTINGS
button to adjust the timer function settings. Press the PLAY/START button at any time to begin op-
erating the device according to the timer settings that have been inputted. You may exit to the main
menu at any time by pressing the BACK/EXIT button.

SYSTEM MENU
14
DMX SET
DMX Addr 1 ~ 512
DMX Mode
1-ch
2-ch
4-ch
PERSONALITY
Wifi Set
Wifi Name 0~xxxxx
If no module
card is installed,
“Optional Module
Not Installed” will
be displayed on
the screen
Wifi Passcode 00000000 -
00009999
Wifi IP 0~255.0~255.0~
255.0~255
Wifi Port 0~65535
Reset Network Complete
Failed, try again
Wifi?DMX &
Magfly On / Off
LCD Set Screen OFF
Never / 10s /
40s / 1min /
2min / 5min /
10min / 20min
Display Flip 0 deg / 180 deg
MagFly Set
MagFly
Channel 0~14
MagFly On / Off
MagRF Learn
Connected Frequency match-
ing capability.
Connection failed
message displays
if connection is
unsuccessful after
20s
Connection Failed, check module
and retry
Last State Yes / No
Device adheres to
last settings used
prior to shutting off
Default Restores device to
factory settings
MANUAL 20% - 100%
CONTINUED ON NEXT PAGE

15
SYSTEM MENU
TIMER
Interval 0~2500s Start or pause
device operation
according to these
values by pressing
the Play/Start icon.
Duration 0~250s
Fan Speed 20%~100%
PRESET
Preset 1
See Preset Modes
section
Preset 2
Preset 3
Preset 4
Preset 5
INFORMATION
State Normal / Error
Slot 1 Null / MagFly / Wifi / MagRF
Slot 2 Null / MagFly / Wifi / MagRF
Last Control
LCD_auto / LCD_manual / DMX
/ Wifi / MagRF / MagRemote /
Error
Displays current
source of device
control
MagRemote
State Yes / No
Displays whether
remote control is
connected
Wifi Connect Null / Phone / Route / No Wifi connection
source
Wifi IP No / 0~255, 0~255, 0~255, 0~255
MagFly Ch 0-14
DMX Addr 1-512
DMX Mode 1-ch / 2-ch / 4-ch
Timer Fan Sp 20% - 100%
Timer Int 0-2500s
Timer Dur 0-250s
LCD Ver V1.2
Sftwr Ver V1.0

PRESET MODE
Selecting the device’s Preset Mode provides the user with a choice of ve (5) pre-programmed
operational modes, which are controlled by an easy-to-use Preset Control Screen (see below). The
details of each preset mode, numbered 1through 5, can be viewed by pressing on the numerical
buttons located near the top of the screen. The duration, interval, and fan speed for the selected
preset mode will be displayed on the screen below the numerical buttons.
Press the PLAY button in the bottom right corner of the screen to operate the device according to
the currently displayed preset mode. Press the BACK/EXIT button in the bottom left corner of the
screen to return to the main menu screen.
The details of each preset mode are shown in the table below:
PRESET MODE DURATION INTERVAL FAN SPEED
1 40 min 20 min 100%
2 25 min 10 min 100%
3 10 min 5 min 100%
4 40 min 20 min 50%
5 10 min 5 min 50%
16

DMX CHANNEL FUNCTIONS & VALUES
CHANNEL VALUES FUNCTION
1-CH 2-CH 4-CH
1 1
On/Off
000 - 005 Off
006 - 255 On
1
Fan Speed
000 - 005 Off
006 - 255 20% - 100%
2 2
Fan Speed
000 - 005 20%
006 - 255 21% - 100%
3
Duration
000 - 005 0s
006 - 255 1s - 250s
4
Interval
000 - 005 0s
006 - 255 10s - 2500s
17

DIMENSIONAL DRAWINGS
Drawings not to scale.
Device is shown with optional equipment; actual equipment level of your device may vary.
18

SPECIFICATIONS
PERFORMANCE
Rated Power: 80W
Max. fan volume: (600cu ft/min.) (17 m3/min)
Fan angle: 0-360°
Fan speed range: 750-2800rpm
CONSTRUCTION
Durable aluminum housing
Compact lightweight mobile design
CONTROL
3 DMX Channel Modes (1 / 2 / 4)
Onboard LCD Touch Control Panel
DMX-512 and RDM Protocol Support
Optional MAGFLY Wireless DMX Transceiver
Optional MAGRF Wireless and Wired Remotes
CONNECTIONS
Locking 5pin XLR Connector In/Out
IP65 Locking Power Connector In
With Wired Digital Communication Network
SIZE / WEIGHT
Length: 15.55 in. (395mm)
Width: 13.19 in. (335mm)
Height: 4.72 in. (120mm)
Weight: 15 lbs. (6.8kg)
ELECTRICAL
AC 100-120V - 50/60Hz
3A (NFB)
Max Power Consumption: 120W
THERMAL
Maximum Ambient Temperature (Ta max) 104°F (40°C)
Exterior Surface Temperature, Steady State: 122°F (50°C)
APPROVALS / RATINGS
CE | cETLus (pending) | IP44
Specications and documentation subject to change without notice.
19

This manual suits for next models
1
Table of contents
Popular Fan manuals by other brands

Ebmpapst
Ebmpapst W6E630-KN01-11 operating instructions

Ebmpapst
Ebmpapst G2E140-AG02-78 operating instructions

Water-Loo
Water-Loo SG1 Operating and maintenance

Ebmpapst
Ebmpapst VBH0450CTTPS operating instructions

System air
System air Topvex FR03 installation instructions

Ebmpapst
Ebmpapst D3G318-BB35-01 operating instructions