Use and maintenance instructions
INDUS with water-tight terminal block
Street lighting luminaire for installation on poles or brackets Ø60mm on top
TECHNICAL DETAILS: please refer to the product label
Insulation Class II
The EU declaration of conformity can be downloaded from our website www.marecoluce.it
Protection degree against dust ingress, solid particles, moisture
This product must not be disposed as a normal household waste
WARNINGS:
•THE SAFETY OF THIS PRODUCT IS GUARANTEED ONLY WITH THE RESPECT OF THE EXISTING RULES FOR
THE ELECTRICAL SYSTEMS, AND WITH THE APPROPRIATE USE OF THESE
INSTALLATION INSTRUCTIONS, THEREFORE IT IS NECESSARY TO KEEP THEM.
• THE IMPROPER USE OF THIS PRODUCT IS FORBIDDEN; ANY TAMPERING WITH THE PRODUCT OR
MODIFICATION OF THE PRODUCT THAT IS NOT AUTHORIZED BY MARECO LUCE CAN CAUSE DAMAGE TO
PEOPLE, ANIMALS OR THINGS, AND WILL VOID ANY WARRANTY OR LIABILITY.
• SWITCH OFF THE ELECTRICITY BEFORE CONDUCTING ANY KIND OF MAINTENANCE.
• THE PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH BEST PRACTICE.
• THE LIGHTING SOURCE OF THIS LUMINAIRE MUST BE REPLACED BY THE MANUFACTURER ONLY
• DAMAGED COMPONENTS MUST BE REPLACED WITH MARECO LUCE ORIGINAL SPARE PARTS BEFORE
REUSING THE PRODUCT.
GENERAL MAINTENANCE RECOMMENDATIONS:
• CLEAN THE FITTING PERIODICALLY TO REMOVE POSSIBLE DIRT DEPOSITS ON THE LUMINAIRE.
• DO NOT USE HARSH DETERGENTS TO CLEAN THE DIFFUSER.
• CHECK THE TIGHTNESS OF THE SCREWS SECURING THE LUMINAIRE TO ITS SUPPORT.
• CHECK THE INTEGRITY OF THE COMPONENTS AND REPLACE THEM IN CASE OF ANY DAMAGE
BY USING ORIGINAL MARECO LUCE SPARE PARTS.
The lighting source of this luminaire must be replaced by the manufacturer only
ENEC 05 certied luminaire
The luminaire is suitable for indoor use
The luminaire is suitable for pole mounting at a maximum recommended height of 15 meters
Suitable for mounting On pole and bracket
Luminaire weight 6,8 Kg
Maximum projected surface area subject to wind pressure 0,186 m²
Dimensions of the compartment housing the connection box
(the box holding the connections) Pict.A
Torque value (in Nm) to apply in tightening all bolts
and screws securing the luminaire on its support 15 Nm
Power factor >0,95
The luminaire is suitable for indoor use
The luminaire is suitable for pole mounting at a maximum recommended height of 8 meters
Suitable for mounting On pole and bracket
Luminaire weight 4,1 Kg
Maximum projected surface area subject to wind pressure 0,112 m²
Dimensions of the compartment housing the connection box
(the box holding the connections) Pict.A
Torque value (in Nm) to apply in tightening all bolts
and screws securing the luminaire on its support 15 Nm
Power factor >0,95
SIZE OF THE CONNECTION BOX
Pict.A
6mm
6mm
20mm Max
20mm Max
1
2
3
457
6
H 110 MIN
1
2
3
4
NC
F
N
1
2
3
4
DIMM+
F
N
DIMM-
18 16
17 18 16
19
6mm
6mm
20mm Max
20mm Max
20
19
Ø7÷8.5mm
Ø9÷13.5mm
7
6
Ø7÷8.5mm
Ø9÷13.5mm
20
470/615
240/320
130/133
NC
1
2
3
4
NC
F
N
1
2
3
4
DIMM+
F
N
DIMM-
NC
SUPPLEMENTARY MAINTENANCE TO REPLACE THE WIRING TRAY:
The luminaire Indus is equipped with a replaceable gear tray thanks to a tool free fast hooking system
1.Unhook the closing clips (12) and remove the whole LED wired tray (13).
2.Unfasten the wiring tray (14) by rotating the relevant lock (15).
3.Disconnect the quick release connectors out of the driver.
4.Replace the wiring tray (14), by connecting the drivers’s quick release wires and pay attention to respect the colours and cable polarity.
5.Put back the lock (15) in the initial position in order to secure the wiring tray (14).
6.Place the whole LED wired tray (13), over the side hooks (16) of the base support (10), and close the side clips (12).
Pict.9
Pole top mounting
Pict.10
Side entry mounting
Pole top tilting ±10° Installation on poles
Adapter Ø60
Guide for the correct
cable polarity
Pict. 8
1. Adjust the luminaire position according to the type of installation (see Pict.9 or Pict.10) by completely untightening the screws (8)
that secure the pole top adaptor (9) to the base support (10). Once you have set the angle of the pole top adaptor (9), tighten
the screws (8) strongly.
2. See Pict.2: unscrew the central ring nut (1) and disconnect the connector (2).
3. Unscrew the ring nut (3) and insert the power supply cable (4) into the ring nut (5) and into the gasket (7);
loosen the ring nut (5) if necessary.
4. Strip the power supply cable (4) following the indications as per Pict.3, then connect it paying attention to respect the
polarities shown in Pict.4: apply 0.8 Nm
5. Close the connector by tightening the ring nut (3) and the ring nut (5) until they stop. Apply 2.5 Nm.
6. Close the terminal block by connecting the connectors paying attention to respect the position of the reference notch.
7. Tighten the central ring nut (1) fully to ensure the IP rate declared. Apply 1 Nm.
8. Insert the luminaire into the pole and tighten the dowels (11).
Guide for the correct
cable polarity
1. Adjust the luminaire position according to the type of installation (see Pict.9 or Pict.10) by completely
untightening the screws (8) that secure the pole top adaptor (9) to the base support (10). Once you have set the
angle of the pole top adaptor (9), tighten the screws (8) strongly.
2. See Pict.6: unscrew the central ring nut (16) and insert the power supply cable (17) into the ring nut (18) and
into the gasket (19); loosen the ring nut (18) if necessary.
3. Strip the power supply cable (17) according to the indications as per Pict.7, then connect it paying attention to
respect the polarities shown in Pict.8. Apply 0,5 Nm.
4. Close the terminal block by by tightening the ring nut (16) and the ring nut (18) until they stop. Apply 2,5 Nm.
5. Insert the luminaire into the pole and tighten the dowels (11).
INSTRUCTIONS FOR THE INSTALLATION OF THE LUMINAIRE WITH THE MALE/FEMALE WATER-TIGHT TERMINAL BLOCK:
INSTRUCTIONS FOR THE INSTALLATION OF THE LUMINAIRE WITH THE
WATER-TIGHT TERMINAL BLOCK: Pict. 5
A CAUTION: Use only a flexible power supply cable in double insulation sheath (type HAR or suitable for
outdoor use). The outer cable diameter must be between 7 and 13,5mm; if the diameter exceeds 9mm,
remove the gasket (20) see Pict.5. The section of the inner electrical wires must be between 0,5 and 4mmq
(1,5mmq is recommended).
A CAUTION: Use only a flexible power supply cable in double insulation sheath (type HAR or suitable for outdoor use). The outer cable diameter must be between 7 and 13,5mm; if the diameter
exceeds 9mm, remove the gasket (7) see Pict.1; the section of the inner electrical wires must be between 0,5 and 4mmq (1,5mmq is recommended). Pict. 1
Pict. 4
Pict. 2 Pict. 3
2 Pole 4 Pole
2 Poles 4 Poles
Fig.6 Fig.7

This manual suits for next models

2

Other Marecoluce Outdoor Light manuals

Marecoluce Barcellona-BARRIO Operation instructions

Marecoluce

Marecoluce Barcellona-BARRIO Operation instructions

Popular Outdoor Light manuals by other brands

WAVE LIGHTING 105 installation guide

WAVE LIGHTING

WAVE LIGHTING 105 installation guide

ARANI WALL PACK 11 quick start guide

ARANI

ARANI WALL PACK 11 quick start guide

Powerfix Profi HG03497A Operation and safety notes

Powerfix Profi

Powerfix Profi HG03497A Operation and safety notes

Saxby Lighting Icarus Photocell 2LT Wall instruction manual

Saxby Lighting

Saxby Lighting Icarus Photocell 2LT Wall instruction manual

HUDSON VALLEY LIGHTING TROY LIGHTING SOREN B8906 installation instructions

HUDSON VALLEY LIGHTING

HUDSON VALLEY LIGHTING TROY LIGHTING SOREN B8906 installation instructions

Profile PLI 144 manual

Profile

Profile PLI 144 manual

JONATHAN Y JYL8011A quick start guide

JONATHAN Y

JONATHAN Y JYL8011A quick start guide

Sulion LISBOA 202005 manual

Sulion

Sulion LISBOA 202005 manual

BEL LIGHTING Atlantic G quick start guide

BEL LIGHTING

BEL LIGHTING Atlantic G quick start guide

Greenlce 1916-SL-JL15-60W instruction manual

Greenlce

Greenlce 1916-SL-JL15-60W instruction manual

JONATHAN Y JYL7604A quick start guide

JONATHAN Y

JONATHAN Y JYL7604A quick start guide

LIGMAN SMITH 3 installation manual

LIGMAN

LIGMAN SMITH 3 installation manual

Coemar LEDko EXT+ FullSpectrum RGBLA user manual

Coemar

Coemar LEDko EXT+ FullSpectrum RGBLA user manual

Sony LKRM-U330 operating instructions

Sony

Sony LKRM-U330 operating instructions

GUBI Seine Assembly instructions

GUBI

GUBI Seine Assembly instructions

MAUL MAULpearly manual

MAUL

MAUL MAULpearly manual

FLINQ FQC8266 instruction manual

FLINQ

FLINQ FQC8266 instruction manual

Hortensus Hor-LED-10m manual

Hortensus

Hortensus Hor-LED-10m manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.