Marine Marvair SeaMach 24 VDC User manual

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 1 of 20
Installation Manual
24 VDC Rooftop Air Conditioner
Chapter 1: Safety Considerations .......................................................................... 2
Chapter 2: General Information ............................................................................ 3
Chapter 3: Air Conditioning Sizing ........................................................................ 3
Chapter 4: Selecting an Installation Location ......................................................... 4
Chapter 5: Installing the Roof Top Unit ................................................................. 4
Chapter 6: Securing the Air Conditioner to the Roof ............................................... 8
Chapter 7: Electrical Wiring .................................................................................. 9
Chapter 8: Installing the Ceiling Assembly (9000 Series) ...................................... 11
Chapter 9: Completing the Installation (9000 Series) ........................................... 14
Chapter 10: Installation, Programming and Operation of the o-Touch Thermostat..... 14
Chapter 11: Maintenance...................................................................................... 20
Manufactured by:
P/N 01991 5/2013 New
Marvair
®
Division of AIRXCEL
®
, Inc
PO Box 400 • Cordele, GA 31010
156 Seedling Dr. • Cordele, GA 31015
(229) 273-3636 • Fax (229) 273-5154
Email: marvair@airxcel.com
www.marvair.com
Marvair
®
Marine UK
Unit B8 • Arena Business Centre • Holyrood Close
Poole, Dorset BH17 7FL.
+44 1202 606405
www.marvair.co.uk
SeaMach 24 VDC Rooftop
Air Conditioner

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 2 of 20
Chapter 1 - Safety Considerations
These instructions are a general guide for installing the SeaMach 24 VDC roof top air conditioners. For
specic air conditioner details, it will be necessary to refer to the printed Customer Envelope Package
supplied with each air conditioner.
IMPORTANT NOTICE:
These instructions are for the use of qualied individuals specially trained and experienced in
installation of this type equipment and related system components.
Installation and service personnel are required by some states to be licensed. PERSONS NOT
QUALIFIED SHALL NOT INSTALL NOR SERVICE THIS EQUIPMENT.
NOTE:
The words “Shall” or “Must” indicate a requirement which is essential to satisfactory and safe product
performance.
The words “Should” or “May” indicate a recommendation or advice which is not essential and not
required but which may be useful or helpful.
Safety Considerations
This is the safety alert symbol . When you see this symbol on the Marvair®unit and in the instruction
manuals be alert to the potential for personal injury. Understand the signal word DANGER, WARNING
and CAUTION. These words are used to identify levels of the seriousness of the hazard.
DANGER Failure to comply will result in death or severe personal injury and/or property damage.
WARNING
Failure to comply could result in death or severe personal injury and/or property damage.
CAUTION Failure to comply could result in minor personal injury and/or property damage.
IMPORTANT is used to point out helpful suggestions that will result in improved installation, reliability
or operation.
!
WARNING - SHOCK HAZARD
To prevent the possibility of severe personal injury or equipment damage due to electrical shock,
always be sure the electrical power source to the appliance is disconnected.
CAREFULLY FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THIS BOOKLET TO AVOID
DAMAGE TO THE EQUIPMENT, PERSONAL INJURY OR FIRE.
!
WARNING
Improper installation may damage equipment, can create a hazard and may void the warranty.
The use of components not tested in accordance with these units will void the warranty, may make the
equipment in violation of state codes, may create a hazard and may ruin the equipment.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 3 of 20
Chapter 2 - General Information
OEM
Please make sure the Customer Envelope Package accompanies the air conditioner.
INSTALLER AND/OR DEALER
Please make sure the Customer Envelope Package is presented to the product consumer.
For more information about the contract, please review the sample contract located in the Operation and
Maintenance Instructions Booklet (Customer Envelope Package).
INQUIRIES ABOUT THE A/C UNIT
Inquiries to your Airxcel, Inc. representative or to Airxcel, Inc. pertaining to product installation should
contain both the model and serial numbers of the roof top air conditioner. All roof top air conditioning
units have model and serial number identication in two locations; (1) rating plate sticker may be viewed
by looking through the shroud louvers on the compressor side of the roof top air conditioning unit. The
rating plate sticker can be seen without removing the outer plastic shroud, (2) model/serial number sticker
(silver color) is located on the bottom of the basepan of the roof top air conditioner. If the air conditioner
is installed, the sticker may be viewed by lowering the ceiling assembly shroud.
Chapter 3 - Air Conditioning Sizing
The ability of an air conditioner to provide a comfortable environment for the consumer is dependent upon
the following conditions.
Air conditioners are rated primarily by their ability to remove heat. The thermal measurement used for
detecting a gain or loss of heat is the British Thermal Unit (BTU). One (1) BTU is the amount of heat
required to raise the temperature of one pound of water by one degree Fahrenheit. An air conditioner rated
at 13,500 BTUH can remove 13,500 BTU’s of heat in one hour.
The ability of an air conditioner to cool down a vehicle or maintain a consumer desired temperature is
dependent upon the heat gain of the vehicle. The physical size, the amount of window area, the quality
and amount of insulation, the position exposure to sunlight, the number of people using the vehicle and
the outside temperature may increase the heat gain to such an extent that the capacity of the air conditioner
is exceeded.
As a general rule, air supplied (discharge air) from the air conditioner will be 15°F to 20°F (11° C to
8.4°C) cooler than the air entering (return air) the ceiling assemblies bottom air grilles.
For example, if the air entering the air conditioner (the return air) is 80°F (26.7), the supply air (discharge
air) will be 60° to 65° F (11.1° to 18.3°C). As long as this temperature difference -15°F to 20° F (11° C to
8.4°C) is being maintained at the air conditioner, the air conditioner is operating properly.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 4 of 20
Again, give careful consideration to the heat gain variables. During extreme outdoor temperatures, the
heat gain of the vehicle or vessel may be reduced by:
Keeping the vessel in a shaded area•
Keeping windows and doors closed•
Avoiding the use of heat producing appliances•
Using window shades (blinds and/or curtains)•
For a more permanent solution to high heat gain situations, additional insulation, window awnings and/or
window glass tinting should be considered.
Chapter 4 - Selecting An Installation Location
Is the roof of the vehicle or vessel capable of supporting both the roof top unit and ceiling assembly without
additional support structures? Inspect the interior ceiling mounting area to avoid interference with existing
structural members such as: bunks, curtains, tracks or room dividers. The depth of the ceiling assembly
shroud is 3” (7.6 cm). Be sure to check clearance for doors which must be swung open (refrigerator,
closets, cabinets).
Chapter 5 - Installing The Roof Top Unit
!
DANGER - SHOCK HAZARD
DISCONNECT ALL POWER BEFORE PERFORMING ANY CUTTING. CONTACT WITH
HIGH VOLTAGE CAN RESULT IN EQUIPMENT DAMAGE, PERSONAL INJURY OR
DEATH.
!
CAUTION
TO PREVENT DAMAGE TO THE WIRING AND BATTERY, DISCONNECT THE BATTERY
CABLE FROM THE POSITIVE BATTERY TERMINAL BEFORE PERFORMING ANY
CUTTING TO THE VEHICLE OR VESSEL.
Once the location for your air conditioner has been determined (See Chapter 4), a reinforced and framed
roof hole opening must be provided (may use existing vent hole). Before cutting into the roof, verify that
the cutting action will clear all structural members and crossbeams. Additionally, the location of any inner
roof plumbing and electrical supplies must be considered.
If a roof vent is already present in the desired mounting location for the air conditioner, the following A.
steps must be taken:
Remove all screws which secure the roof vent to the vehicle. Remove the vent and any additional 1.
trim materials. Carefully remove all caulking from around the roof vent opening to obtain clean
exterior roof surface.
It may be necessary to seal some of the old roof vent mounting screw holes which may fall outside 2.
of the air conditioner basepan gasket.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 5 of 20
Examine the roof opening. If the opening is smaller than 14” x 14” (35.6 cm x 35.6 cm), the 3.
opening must be enlarged. If the opening exceeds 15” x 15” 38 cm x 38 cm), a mounting frame
must be field fabricated to reduce the opening size (See Figure 1).
If a roof vent opening is not used, a new opening (See Figure 1) will have to be cut into the vehicle B.
roof. A matching opening will also have to be cut into the interior vehicle ceiling. Be careful when
cutting the ceiling opening.
After the opening in the roof and interior ceiling are the correct size, a framed support structure must
be provided between exterior roof top and interior ceiling. The reinforced framed structure must
provide the following guidelines:
Capable of supporting both the weight of the roof top air conditioner and the interior ceiling 1.
assembly.
Capable of holding or supporting the roof outer surface and interior ceiling apart, so that when the 2.
roof top air conditioner and ceiling assembly are bolted together, no collapsing occurs.
Airxcel’s SeaMach air conditioner requires that the spacing from the vehicle roof top to the interior
ceiling be no less than 1” (2.34 cm). A typical support frame is shown in Figure 1.
The frame must provide an opening to allow passage for the power supply wiring. Route the supply
wiring through the frame at the same time the support frame is being installed.
IMPORTANT – Allow 24” (61 cm)of supply wiring through the support frame (working length).
After the support frame is installed, seal off all gaps between the frame and both the roof exterior
and the interior ceiling of the vehicle or vessel (cavity walls). Additionally, seal the gap around the
electrical supply wiring.
This air conditioner is to be installed in accordance with NFPA Standard 501C.C.
The roof top air conditioner must be mounted as near level from front to rear and side to side as is D.
possible when the vehicle is parked on a level plane. Figure 2 shows maximum allowable degree
deviations (mounting degrees from total surface at plane).

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 6 of 20
FIGURE 3
15 DEGREE MAX. ABOVE LEVEL 15 DEGREE MAX. ABOVE OR BELOW LEVEL
NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT
OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN.
ALLOWABLE OFFSET FOR ALL HEAT PUMPS
WITH ROTARY COMPRESSORS.
FIGURE 2

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 7 of 20
FIGURE 3
If the roof of the vehicle or vessel is sloped (not level) such that the roof top air conditioner cannot be
mounted within the maximum allowable degree deviations, an exterior leveling shim will need to be
added to make the roof top air conditioner level. A typical leveling shim is shown in Figure 3.
After the mounting hole area is properly prepared, remove the carton and shipping pads from the roof top
air conditioner. Carefully lift the unit to the top of the vehicle. Do not use the outer plastic shroud for
lifting. Place the roof top air conditioner over the prepared mounting hole. The pointed end (nose) of the
shroud must face towards the front of the vehicle or vessel. Pull the electrical conduit down from the roof
air conditioner through the mounting opening and let hang.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 8 of 20
Chapter 6 - Securing The Air Conditioner To The Roof
A mounting frame is supplied with the ceiling assembly. Follow the steps below to secure the air conditioner
to the roof. Refer to Figure 4.
Locate the air conditioner mount gasket over the 14” (35.6 cm)to 15” (38 cm) square opening in the A.
roof.
Install the ceiling assembly mount frame using the four bolts found with the ceiling assembly.B.
Proper tension has been achieved for each bolt when any portion of each gasket indicating tab has been C.
pulled down even with the roof. See Figure 4. The upper unit has now been properly installed with
optimum gasket compression.
FIGURE 4

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 9 of 20
Chapter 7 - Electrical Wiring
ROUTING 24 VDC WIRING:
Following Airxcel’s low voltage wiring specications and local National Electrical Codes (NEC), route
the Roof Top Unit 24VDC supply wiring from its power source to the wire box. Use the chart below as a
guide knowing the amp draw listed on the unit rating plate to size the minimum wire size for use for the
distance in feet between the unit and your power supply.
This is a ve percent table which means at these amperage ratings at the listed distances, 5% of the power
would be lost to resistance.
24 VOLT DC CHART
Amps in Wire Watts at 24V #14 #12 #10 #8 #6 #4 #2 1/0 2/0 3/0
124 169 262 412 675
248 84 131 207 337 532
496 37 66 103 169 267
6144 28 45 66 112 178 282
8192 21 32 54 84 133 216
10 240 17 26 43 67 107 169 270
15 360 11 17 26 45 71 112 180 289
20 480 13 21 37 54 84 135 217 270 343
25 600 17 26 43 67 108 172 217 274
30 720 13 22 36 56 90 144 180 228
40 960 17 26 43 67 108 135 171
50 1200 13 21 34 54 86 108 137
ELECTRIC CIRCUIT
DC POWER REQUIREMENT: 1243 Watts
OPERATING CURRENT: 13 - 40 Amps
MINIMUM CIRCUIT AMPACITY (DC AMPS): 50
Follow all local and NEC (National Electrical Code) for proper sizing of wire AWG based on
Overcurrent Protection Device selected and the length of the wiring run to the air conditioner.
!
DANGER - SHOCK HAZARD
MAKE SURE THAT ALL POWER SUPPLY TO THE UNIT IS DISCONNECTED BEFORE
PERFORMING ANY WORK ON THE UNIT TO AVOID THE POSSIBILITY OF SHOCK
INJURY OR DAMAGE TO THE EQUIPMENT.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 10 of 20

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 11 of 20
!
DANGER
WHEN USING NON-METALLIC SHEATH CABLES (ROMEX, ETC.), STRIP SHEATH BACK
TO EXPOSE 4-6 INCHES OF THE SUPPLY LEADS.
STRIP THE INDIVIDUAL WIRE LEAD ENDS FOR WIRE CONNECTION (ABOUT 3/4” BARE WIRE). INSERT
THE SUPPLY WIRES INTO THE ELECTRICAL CONNECTOR CLAMP. SHEATH MUST PROTRUDE PAST
THE CLAMP BUSHING INSIDE THE BOX AS ILLUSTRATED. MAKE SURE SHEATH CABLE IS CENTERED
IN CLAMP BEFORE TIGHTENING UP ON IT. DO NOT OVERTIGHTEN!!
THIS COULD RESULT IN PINCHING THROUGH THE PLASTIC WIRE INSULATION AND CAUSE SHORTING
OR “HOT” WIRES TO GROUND (SHOCK HAZARD). THE CLAMP IS INTENDED FOR STRAIN RELIEF OF
THE WIRES. SLIGHT PRESSURE IS USUALLY SUFFICIENT TO ACCOMPLISH THIS.
IF OTHER THAN NON-METALLIC CABLES ARE USED FOR SUPPLY CONDUCTORS, APPROPRIATE
STRAIN RELIEF CONNECTORS OR CLAMPS SHOULD BE USED.
IN NO CASE SHOULD CLAMPING OR PINCHING ACTION BE APPLIED TO THE INDIVIDUAL SUPPLY
LEADS (NEUTRAL AND “HOT” WIRES).
!
DANGER - SHOCK HAZARD
TO PREVENT THE POSSIBILITY OF SHOCK INJURY, THE WHITE WIRE MUST BE CONNECTED TO
NEUTRALIN THE SERVICE BOX ENTRANCEAND THE MECHANICALGROUND MUST BE CONNECTED TO
A GROUNDING LUG EITHER IN THE SERVICE BOX OR THE MOTOR GENERATOR COMPARTMENT.
Chapter 8 - Installing The Ceiling Assembly (9000 Series)
Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.
The following step by step instructions must be performed in the following sequence to insure proper
installation.
A.Carefully uncarton the ceiling assembly. Controls are factory installed in the ceiling assembly A.
(except ceiling assemblies for applications with remote control box/thermostat).
Remove the grille and lters from the ceiling assembly.B.
Fasten the duct collar to the basepan of the air conditioner with three (3) screws (See Figure 7).C.
Plug the roof top air conditioner electrical conduit into the 9 position receptacle located in the thermostat D.
side of the ceiling assembly.
Insert the supply wiring through the cable clamp and into the eld wiring box so that 4 - 6” (10 cm to E.
15 cm) of supply conductor is inside the box. Secure the cable clamp over the supply wire sheath so
that no movement is possible (See Figure 6).
Connect the supply power conductors to the black and white pigtail wires and the supply ground wire F.
to the green pigtail wire found in the eld wiring box using the 3 provided wire nuts. IMPORTANT
– Connect the black supply to the black pigtail and the white supply to the white pigtail. Using a U.L.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 12 of 20
approved electrical tape, secure the wire nuts to wires in a workmanlike manner (See Figure 6).
Place the metal control box shield over the thermostat, switch and eld wiring boxes. Make certain G.
that all wires are pushed into the control boxes or laying in the wireway between the thermostat and
switch boxes and will not be pinched by the control box shield. Control box shield is properly installed
when the two holes in the shield are aligned with the two screw holes in the ceiling assembly chute
(See Figure 5).
Raise the ceiling assembly and secure to the mounting frame with 4 provided shoulder screw/spring H.
assemblies. The front two screws should pass through the clearance holes in the metal control box
shield (See Figure 7).
The ceiling assembly shroud is curved to contour to a crowned ceiling. If installation is to a at I.
ceiling and gaps are present on the sides of the shroud, insert the four optional 3/4 inch (19 mm)screws
(provided) through the mounting posts and secure them to the mounting frame above (See Figure 5,
6, & 7 for screw locations).
Pull the fabric duct material through ceiling assembly discharge opening. Peel the release liner from J.
the adhesive strip around the discharge opening. Press the fabric duct material rmly in place around
opening. Cut off excess fabric on inside of ceiling assembly chute with a box knife taking care not to
tear the fabric beyond the adhesive strip.
FIGURE 5 FIGURE 6

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 13 of 20
FIGURE 7

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 14 of 20
Chapter 9 - Completing The Installation (9000 Series)
Make sure the non-allergenic lters are properly positioned in the ceiling grille.A.
Install the ceiling grille by positioning on the bottom of the shroud and engaging the two 1/4 turn fasteners.B.
Turn the selector switch to OFF positionC.
Turn ON the power supply to the roof top air conditioner.D.
System Checkout – Airxcel, Inc. manufactures a wide range of roof top air conditioners which incorporate different product E.
operation features. To properly evaluate the performance of a newly installed air conditioner, it is necessary to review the
specic unit operation characteristics (features) described in the product operation and maintenance instructions (Customer
Envelope Package).
Chapter 10 - Installation, Programming and Operation of the
o-Touch Thermostat
Introduction
When connected to a 12-24VDC controller, the versatile o-Touch DC digital display provides room
temperature control and humidity reduction in a small package. It allows for easy control of fan speed,
operating mode and temperature in a wide variety of applications.
Features Include:
Easy touch screen operation.•
Built in room temperature sensor.•
The display is compatible with Vimar and Gewiss frames. •
Visual symbols enable the viewer to see the operating status at a glance.•
Easily programmed for customized operation.•
Both automatic and manual six level fan speed control.•
De-icing cycle to prevent evaporator icing.•
Automatic moisture mode provides relative humidity control.•
Variable compressor speed control reduces power consumption as ambient temperature approaches •
the set point.
Compressor current limiting can be used to prolong battery life.•

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 15 of 20
Operations
Applying Power:
When power is rst applied, the display will show the software revision, and then return to the last operating
mode the unit was in when power was removed.
Screen Saver:
In screen saver, the display will appear dim and the information will scroll across the screen. Status
symbols appear as needed and operation continues in the mode selected. Screen saver is activated after
two minutes without touching the screen in any mode. To exit screen saver, just touch the screen.
Off Mode:
When the display is in the off mode, the temperature will show in the center of the screen along with the
fan and on / off symbol. The fan may be operated in this mode by pressing the fan symbol. Press the On/
Off button to access other operating modes.
Operating Display
Temperature
Set Point
Mode Symbol
Ambient
Temperature
On/O Symbol
Fan Speed Indicator
Fan
Operating
I/O
Operating Modes:
Two operating modes are available and can be changed by pressing the symbol in the upper left corner.
The symbols below will appear in the upper left on the display.
Moisture Mode Symbol Cool Mode Symbol
Set the desired room temperature in cooling mode by pressing the set point in the upper right corner. Use
the arrows to raise or lower the set point and press X when you are nished.
Moisture mode is used to help control humidity in the room while the room is unoccupied. The control will
operate in cooling mode for up to 1 hour every 6 hours.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 16 of 20
Operating the Fan:
Fan speed may be set for automatic (temperature dependent) or manual control. Press the fan operating
symbol in the bottom right corner to change speeds. Manually selected fan speed is indicated with the M
showing before the fan speed indicator. When the fan is automatically controlled, the M is not present. The
fan may be controlled in the cool, heat, automatic modes as well as in the off state.
Manual fan speed operation is not available when the compressor is not running if the “Cycled Fan”
option is set. Turn the unit off in this case and then manual fan operation may be used. Manual fan speed
operation is also not available in moisture mode.
System Status Screen
System Current
Motor Current
System Voltage
Motor
Temperature
Motor Speed
Several system operating parameters can be viewed during operation as shown above. Press and hold the
lower center of the display (where the fan speed indicator is located) to view this status. To exit the status
view, press anywhere on the display.
The system current is available at all times, the remaining items only during compressor operation.
Failure Messages:
The following fault messages will be shown on the display in the event of a failure:
AIR SENSOR TROUBLE: Failure of the display mounted air sensor.
MASTERFLUX GENERATED ERRORS: Errors generated by the Masterux controller will also show
on the display. The exact text of these errors is dependent on the connected controller. See the operating
manual for your Masterux controller for details and resolution of these errors.
Programmable Parameters
Program Mode:
To enter the program mode rst put the unit in the off mode. Then press and hold the On/Off symbol for 3
seconds. Press the right arrow to advance to the next parameter and press the left arrow to go back to the
last parameter. Press the up or down arrows to change the parameters value. Exit the program mode when
nished by pressing the X or wait 60 seconds for the display to exit.

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 17 of 20
Parameter Description:
Cycled Fan:• When set for “Cycled”, the fan will operate on demand. When set for “Continuous”,
the fan will always operate when the system is in cool mode.
System Units:• Degrees Fahrenheit (°F) or degrees Celsius (°C) can be selected
Display Brightness:• Display brightness can be set from 4 to 15 to suit room lighting conditions.
Screen Saver Brightness:• If set for (0) then a single bar will blink sequentially in the four corners
of the display. Values from 1 to 8 can be set to suit room lighting conditions.
Temperature Calibration:• This parameter allows the user to calibrate the room air temperature
sensor. The room temperature will be displayed and can be adjusted +/-10 °F or +/-5°C
Staging Delay:• The compressor staging delay is provided for multi system installations. Set the
Staging delays at different intervals so only one compressor starts at a time when power is
applied.
De-Ice Time:• If the compressor runs continuously for longer than one hour, the compressor will
shut down and the blower will run for the specied time. The compressor will then restart and
resume operation.
Cycled Pump:• When set for “Cycled”, the pump will run on demand. When set for “Continuous”,
the pump will run continuously when the system is in cool mode.
Fan Speed 1-6:• These parameters are used to optimize fan performance and airow Speed 1
corresponds to the lowest speed setting. Speed 6 corresponds to the highest speed setting. Speeds
should be set to avoid system icing in humid environments.
Maximum Comp Current:• Thirty seconds after starting a cooling cycle the compressor current
will be limited to this value.
Compressor Speed Range:• The number of degrees from set point to maximum compressor
speed.
Reset Parameters:• To reset all parameters to factory defaults, select YES and then exit the program
mode by pressing the on / off button. The display will show “EEPROM RESET”, and then show
the room temperature in the off mode.
Programmable Parameters Table:
Description Default Value
Cycled fan Continuous Cycled or Continuous
System units °F °F or °C
Display brightness 15 4=Minimum 15=Maximum
Screen saver brightness 4 - and 1-8
Temperature calibration 0 Ambient +/- 10°F
Staging delay 15 5-135 Seconds
De-Ice time 2 1-5 Minutes
Cycled pump Cycled Cycled or Continuous
Fan A speed 1 30 30-90
Fan A speed 2 35 30-90
Fan A speed 3 40 30-90
Fan A speed 4 45 30-90
Fan A speed 5 55 30-90
Fan A speed 6 85 30-90
Compressor speed range 2 (1.1) 2-5 °F (1.1-2.8 °C)
Maximum comp current 35 Off, 10-60 Amps
Reset Parameters No No or Yes

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 18 of 20
Specications
Set point range 55°F to 85°F
12.7°C to 29.4°C
Ambient temperature range displayed 5°F to 150°F
-15°C to 65.6°C
Sensor accuracy +/-2°F at 77°F
+/-1.1°C at 25°C
Evaporator Output MAX 10 Amps
Condenser Output MAX 10 Amps
System Current MAX 60 Amps
Minimum operating temperature 0°F
17.8°C
Maximum operating temperature 180°F
82.2°C
Maximum RH conditions 95% Non-condensing
Maximum length of the display cable 75 Feet
22.86 m

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 19 of 20

SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013 Page 20 of 20
1976A520 (10-11) PP
Chapter 11 - Maintenance
One of the biggest advantages to your air conditioner is that the maintenance needed to keep the unit in
good care is minimal. As the owner, your primary responsibility is the cleaning and replacement of the
lter(s). Filters are made from long life natural bers which can be cleaned and reused.
If the lters are not cleaned at regular intervals, they may become partially clogged with lint, dirt, grease,
etc. A clogged lter will produce a loss of air volume and may eventually cause an icing-up of the cooling
(evaporator) coil. The lters should be cleaned or changed at least every two weeks when the air conditioner
is in operation.
Cleaning and/or changing the lters:
Disengage the two 1/4-turn fasteners that secure the ceiling assembly grille to the ceiling assembly 1.
(See Figure 7).
Lower the grille and lter(s) from the ceiling assembly.2.
Take lter(s) out and either clean or exchange with other lters (See Figure 7).3.
If the vehicle is equipped with a ush mount ceiling assembly, remove the four return air grill 4.
screws.
Remove lter from grill and either clean or exchange with new lter.5.
NOTE: If replacement lters are necessary, they can be purchased from most Authorized Service
Centers. It is recommended that spare lters be carried with the unit at all times to replace worn,
torn or deteriorated lters.
Service Person:
Electrical -A. All electrical work and/or inspection should be performed only by qualied service
personnel. Contact your nearest Service Center if electrical problems should arise.
Check Points -B. Failure to start or to cool the air are sometimes problems with air conditioning
units. The air conditioner is designed to operate on 24 VDC electrical power. If the compressor on
the air conditioner fails to start, check with your Service Center to determine that the proper wire
size is connected to the unit, the proper circuit breakers are installed as protection devices on the
electrical circuit. Refer to the chart on page 9 to determine if the proper size wire is being used.
Each air conditioning unit must be protected with a 50 amp time delay fuse or circuit breaker.
If the air conditioner continues to trip off the circuit breakers, have an electrician check the starting
amperage and running amperage on the unit. If the circuit breaker continues to trip off and the electrical
consumption is found to be normal, it will require the replacement of the faulty circuit breaker. If all
electrical power to the air conditioner is normal but neither the fan nor the compressor will operate,
the connector plug located behind the ceiling assembly control box should be checked to determine
whether it is faulty.
Mechanical Integrity -C. The air conditioner should be inspected periodically to be sure that the bolts
which secure the unit to the roof are tight and in good shape. Also, an examination of the plastic
shroud covering the air conditioner on the top of the roof should be made periodically. Be sure the four
mounting screws and washers are snug and holding the shroud to the air conditioner. Also examine the
shroud to be sure it is not developing cracks or has suffered damage from impact.
Airxcel, Inc.
Marvair Division
156 Seedling Dr.
Cordele, GA 31015
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual