MATALA WATER TECHNOLOGY G-1900 Instructions for use

-1-
GeyserFlow Series
Waterfall Pump
zG-1900 1/6HP 100W / Discharge 1”
zG-2300 1/4HP 200W / Discharge 1.25”
zG-3500 1/3HP 250W / Discharge 1.5”
zG-4200 1/2HP 400W / Discharge 2”
zG-4900 3/4HP 600W / Discharge 2”
zG-6300 1HP 750W / Discharge 2”
Instruction and Maintenance Manual
Matala®
“Make water alive”

-2-
Introduction
Thank you for selecting the GeyserFlow Series Waterfall Pump.
This instruction manual explains the product operations and gives important precautions
regarding its safe use. In order to use the product to maximum benefit, be sure to read
the instructions thoroughly and follow them carefully.
To avoid accident, do not use the pump in any way other than as described in this
instruction manual especially when you see ! WARNING .After reading this instruction
manual, keep it nearby as a reference in case questions arise during use.
If this instruction manual should become lost or damaged, ask your nearest dealer or
representative for another copy.
Contents
9Construction and Parts List…………... 3
9Prior to Operation ………………………. 3
9Specification …………………………….. 3
9Installation ……………………………….. 4
9Electrical Wiring …..……… …………… 5
9Guarantee …………… ……………...… 5
9Troubleshooting ……………………….. 6
Construction and Parts List

-3-
Prior to Operation
Check the following points upon receipt of your pump:
¾Is the pump exactly what you ordered? Check nameplate. It is especially important that you
check whether the pump is to be used with 50 or 60 Hz.
¾Has any damage occurred during shipment? Are any bolts or nuts loose?
¾Have all necessary accessories been supplied? (For a list of standard accessories see
Construction.)
We recommend that you keep a spare pump on hand in case of emergencies. Keep this instruction
manual in a place for future reference.
Specifications
Check the nameplate for your pump’s specification as the table list.
Be careful not to exceed the given specifications in the use of your pump.
Other specifications are noted in the chart below.
Output Discharge Rated Maximum Dimension Weight
Model (Hp) (W) (mm) (Inch) Head(Ft.) Flow(GPH) Head(Ft.) Flow(GPH) L x W x H (mm) Kg/lb
G-1900 1/6 100 25 1" 10 1392 22.0 1910 190x130x280 5.0/11.0
G-2300 1/4 200 32 1-1/4" 10 1828 25.0 2320 190x130x280 6.0/13.2
G-3500 1/3 250 40 1-1/2" 15 2119 28.7 3470 200x135x285 6.5/14.3
G-4200 1/2 400 50 2" 15 2825 30.1 4200 236x145x352 10.0/22.0
G-4900 3/4 600 50 2" 20 3127 34.5 4890 276x165x425 12.0/26.4
G-6300 1 750 50 2" 20 4199 37.7 6290 260x160x430 15.0/33.0
Float switch is o
p
tion.

-4-
Installation
Symbol and Meaning :
DANGER
DANGER Keep the pump equipment out of the reach of children!
Warns that the failure to follow the directions given could cause serious
risk to individuals or objects.
WARING
Thissignwarnstheoperatorthatthefailuretofollowaninstruction
may damage the pump and/or the system.
Limitations:
This series of pumps are suitable to pump rain water and also can be used both for permanent and
temporary installation.
The pump can be place for sump pit that means it could pump dirty water containing suspended solid
particles 11-15mm/ 0.4-0.6inches diameter.
! WARNING : The pump cannot be used for sea water and flammable, corrosive, explosive or dangerous
liquids.
Installation :
! WARNING : Do not work on pump until power is unplugged.
Do not cut off ground pin or use an adapter fitting.
Do not use an extension cord
The pump power cord should be connected to a separately fused, grounded line with a minimum capacity
of 15 amps. It can be connect to non- fuse breaker at the recommended amperes. Never touch the pump
when it is connected to electrical power.
1. Before installing or servicing this pump, be certain pump power source is disconnected.
2. Installation and electrical wiring must adhere to state and local codes and must be completed before
priming pump. Check appropriate community agencies, or contact local electrical and pump
professionals.
3. Call an electrician when in doubt. Pump should be connected to a separate 15 amps' circuit breaker or
15 amps' fuse block. Note that, plugging into existing outlets may cause low voltage at motor,
causing blown fuses, tripping of motor overload, or burned out motor.
4. A permanent ground connection from pump to the grounding bar at the service panel is mandatory,
Matala Pump sump pumps come with a grounding conductor and a grounding-type attachment plug.
Do not connect pump to a power supply until permanently grounded. For maximum safety, connect
pump to a circuit equipped with a Ground Fault Circuit Interrupter device when you position the
pump's grounding wire.
5. Voltage of power supply must match the voltage of the pump.
6. Before installing pump, clear sump basin of any water, debris, or sediment.
! WARNING : Sump basin must be vented in accordance with local plumbing codes. Matala Sump
pumps are not designed for and CANNOT be installed in locations classified as
hazardous.
7. ! WARNING : The following may cause severe damage to pump and will void warranty:
(a) Using an extension cord.
(b) Cutting off the ground pin or using an adapter fitting.
(c) Working on pump or switch while plugged in.
(d) Removing motor housing, unscrewing impeller, or otherwise removing impeller seal.
(e) Pumping chemicals or corrosive liquids.
(f) Pumping gasoline or other flammable liquids.
(g) Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe may all be used.
All piping must be clean and free of all foreign matter to prevent clogging. Use thread
compound on all threaded joints unless specified otherwise. Be sure to seal the
thread connection with tape seal when you using the pipe fitting to connect the flange.
WARNING

-5-
Electrical Wiring
Electrical wire Connection :
! WARNING : Verify that the voltage and frequency of the electric pump shown on the nameplate
correspond to those available on the mains.
The installer must make sure that the electric system is grounded in accordance with the law
in force.
It is necessary to use cable with a length of 10m for outdoors using. The plug and connections should be
protected from water splashes. Before using the pump, always inspect it visually (especially power cable
and plug).
Do not use the pump if it is damaged.
If the pump is damaged, have it inspected by the specialized assistance service only.
Make sure that electric connections are protected from inundation. Protect the plug and the power cable
from heat, oil or sharp edges.
! WARNING : The power cable must be replaced by qualified personnel only.
Grounding: The plug of the power cable has a double grounding contact, so that grounding
can be performed by simply inserting the plug.
Overload protection :
This pump series have a built in thermal protection switch. The pump stops if an overload condition occurs.
The motor restarts automatically after it has cooled down.
Limited Warranty :
Matala Pump will repair or replace for the original user any portion of a new Matala Pump product which
proves defective due to materials or workmanship of Matala Pump within 2 years of purchase date.
Contact the nearest authorized Matala Pump dealer for warranty service.
Matala Pump shall possess the sole right to determine whether to repair or replace defective equipment,
parts or components.
THIS WARRANTY DOES NOT COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS
BEYOND THE CONTROL OF Matala Pump.
LABOR & COSTS : Matala Pump shall in no event be liable for the cost of field labor to other charges
incurred by any customer in removing and/or reaffixing any Matala Pump product,
parts or component.
THE WARRANTY WILL NOT APPLY:
(a) to defects or malfunctions resulting from failure to properly install, operate, or maintain the unit in
accordance with printed instructions provided.
(b) to failures resulting from abuse, accident, or negligence.
(c) to normal maintenance services and the parts used in connection with such service.
(d) to units which are not installed in accordance with applicable local codes, ordinances, and good trade
practices.
(e) if unit is used for purposes other than for what it was designed and manufactured for.
WARRANTY EXCLUSIONS : Matala Pump
SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE AFTER THE TERMINATION OF THE WARRANTY PERIOD.
Guarantee
The right to claim under guarantee must be proven by the purchaser by presentation of the purchase
receipt.
Note :
1. Should your equipment not function correctly, please first check for other reasons, e.g.
interruption of the power supply, or incorrect handling may be the cause.
2. Please note that it is imperative that the following documents and details are produced together
with your faulty equipment :
(a) Purchase receipt
(b) Designation of the apparatus/ type/ brand
(c) Description of the noted defect (an accurate description of the defect makes a rapid repair
easier for us)
In the case of a claim for guarantee or defects, please contact the place of purchase.

-6-
Troubleshooting
Problems Possible Causes
Pump dose not
run and hums
* Line circuit breaker is off, or fuse is burned or loosed.
* Water level in sump has not reached turn-on level as indicated
in installation drawing on the carton.
* Pump cord is not making contact in receptacle.
* Float (optional) is stuck. It should operate freely in basin.
* If all of the above are OK and then the motor could be operate.
Pump runs
but does not
deliver water
* Check valve (optional) is installed backwards. (Not included with pump)
Arrow on valve should point in direction of flow.
* Discharge shut-off valve (if used) may be closed.
* Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
* Pump is air-locked. Start and stop several times by plugging and
unplugging cord. Check for clogged vent hole in pump case.
* Inlet holes in pump base are clogged. Remove pump and clean the openings.
* Vertical pumping distance is too high or the pipe size is too small. Reduce
vertical distance or increase the pipe size fittings.
Pump runs and
Pump out sump,
but does not stop.
* Float (optional) is stuck in up position. Be sure float operates freely in basin.
* Defective float switch. Replace with float switch.
* Defective vertical switch. Replace with vertical switch.
Pump runs but
delivers only a small
amount of water
* Pump is air-locked. Start and stop several times by plugging and unplugging
cord. Check for clogged vent hole in pump case.
* Vertical pumping distance is too high or pipe size is too small. Reduce vertical
distance or increase the pipe size.
*Inlet holes in pump base are clogged.
Remove pump and clean the openings.
* Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
* Pump impeller is partially clogged with debris, tar or paint, causing motor
to run slow and overload. Remove pump and clean.
Fuse blows or circuit
breaker trips when
pump starts.
* Pump impeller is partially clogged with debris, tar or paint, causing motor
to run slow and overload. Remove pump and clean.
* Motor stator may be defective.
* Fuse size or circuit breaker may be too small. (Must be 15 amps).
* Impeller or volute opening are fully or partially clogged.
Remove pump and clean.
Motor runs for a
short time, then
stops.
* Inlet holes in pump base are clogged. Remove pump and clean the openings.
* Pump impeller is partially clogged with debris, tar or paint, causing motor
to run slow and overload. Remove pump and clean.
* Motor stator may be defective.
* Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
This manual suits for next models
5
Table of contents
Popular Water Pump manuals by other brands

Lincoln
Lincoln 85353 Service & operating manual

Grundfos
Grundfos MAGNA1 D instructions

Gardner Denver
Gardner Denver THOMAS PICOLINO VTE 3 Operation manual

Glentronics
Glentronics PRO Series Instruction manual & safety warnings

ProMinent
ProMinent Plasma PSMa operating manual

Angelo Decor
Angelo Decor Sensible Solar AD40120 user manual