Matsusada AMPS Series User manual

Rev. 1.0
B/N 190.9.038 *190.9.038*
MODEL
AMPS series
Instruction Manual
F-RA-001-3R2

F-RA-001-5R0
For Safe Use
◆Introduction
This product generates high voltage and energy.
In order to use the product safely and prior to using the product, please read the instruction manual to the end
before use in order to use the product safely, because there is a danger of death or serious injury due to electric
shock. Please use the product after fully understanding how to use the product properly. We are not responsible for
any damages incurred by not observing the warnings and procedures stated in the instructions, so be forewarned.
Keep the instruction manual carefully so that you can view it whenever you need.
◆Symbols
In order to use the product safely, the following symbols are displayed in the instruction manual and on the product.
Understand the meaning of the symbols and observe each item. Depending on the product, some symbols may not
used.
禁止
Indicates content that
could cause death or
serious injury.
Indicates content that
could cause injury or
damage to property.
Indicates danger / warning /
caution. Refer to the instruction
manual when using the part with
this symbol.
Indicates where high voltage is
handled. Touching it may cause
electric shock and result in death
or serious injury.
This symbol means “Prohibited”.
Protective earth terminal (ground
terminal for electric shock
prevention)
Ground terminal
Frame or chassis terminal
Power On
Power standby
The product will not be completely
disconnected from the power
supply even if it is set to standby.
Bistable push button switch on
Bistable push button switch off
Power Off
High temperature attention
Touching it carelessly may cause
burns.
Indicates that it must be performed
in order to demonstrate the
performance of the product.
Alternative Current
WARNING
CAUTION

F-RA-001-5R0
◆Understand the risk.
Products generate high voltage and energy.
An electrician or equivalent knowledge must read the instruction manual to the end and familiarize yourself with the
proper use and danger of the product.
If you want the product to be handled by another person, limit it to those with knowledge of electricity, and have
people who are familiar with correct use and danger of the product conduct education and training before handling
it, or handle the product under the supervision of those who are familiar with the proper use and danger of the
product. Persons, with the exception of the above, must not handle the product.
◆Do not open the product case and panel.
Do not disassemble, remodel, or repair by opening the product case and panel yourself. There is a high voltage area
inside, which may possibly cause electric shock and fire.
Never remove the case and panel of the product, since the safety and function of the product will not be
guaranteed.
◆It is not suitable for use in places where there is a possibility of a child being present.
The product is designed assuming that it will be used in places where there are only adults, such as factories and
laboratories. Do not use it where there is a possibility of a child being present.
◆Ensure that the product is handled only by a limited number of people.
Only those who are familiar with the proper use and danger of the product, or those who are educated and trained
by them should install the product. Any other person handling the product may cause electric shock, burns and
injuries.
◆Ground it.
When the product has a protective ground terminal or GND terminal, connect it to the ground.
If the input terminal of the product is an inlet type, connect to the power outlet with the ground using the supplied
power cable or a power cable suitable for the area to be used. If it is not connected to the ground, there is a risk of
electric shock and fire, which is extremely dangerous.
◆About power supply cable
If there is a power supply cable attached to the package or product, it cannot be used for other products. In the
case of a product that does not include a power supply cable, you must purchase an optional power supply cable
suitable for the operating environment and the area, or you must prepare it yourself.
◆About the connection of the power supply cable
Connection of the power cable should be done by an electrician or someone who has equivalent knowledge and is
familiar with the correct usage and danger of the product. Refer to the page about connection of the input cable in
the instruction manual and carry out work. For products that have acquired safety standards, also refer to the page
that describing overvoltage categories.
◆About input voltage
For the input voltage of the product, refer to the page describing the input terminal of the product and the input
voltage in the instruction manual. Do not supply input exceeding the specifications of the product.
◆About the fuse
The product contains a protective fuse. In the case of a product in which a fuse holder is arranged externally, it is
possible to replace the fuse. For the replacement method, refer to the instruction manual.
If the product does not have a fuse holder externally, the user cannot replace the fuse. If the fuse blows out, do not
open the case or panel. Please contact our sales representative.
◆Do not modify or damage the cable.
It may cause electric shock and fire.
WARNING

F-RA-001-5R0
◆Designed for indoor use
Use the product indoors. Do not use it outdoors or indoors where there is a possibility of water leakage, flooding, or
crown.
◆About operating temperature and humidity
Use within the range of operating temperature and humidity stated in the instruction manual.
Do not use it in a place where the ambient temperature becomes higher than the operation temperature of the
product or in a narrow closed place.
◆Do not install in places that cause condensation.
Do not install it in places that cause condensation, where it is exposed to steam or water vapor.
Insulation deteriorates, causing breakdown, electric shock, or fire.
◆Do not place anything on top of the product.
Falling or collapsing is dangerous.
◆Do not put any objects on or in the product.
Do not put any objects such as metal or liquid in the product through the inlet etc. Failure, electric shock, fire may
result.
◆Operate the product with your right hand.
In case of electric shock when manipulating the product, in order to reduce the risk of current flowing through
important organs of the body. Keep your left hand off from the product and operate with your right hand.
◆Do not touch the wiring or load connected to the output terminal or output terminal during operation or
immediately after output stop.
Very high voltage is applied to the terminals during normal operation and trial operation.
Touching it will result in electric shock.
In addition, since a capacitor is connected to the terminal, high voltage remains on the terminal even immediately
after stopping the output. To avoid electric shock, do not touch the terminals.
◆Turn off the power when touching the terminal.
Before touching the terminals of the product, turn off the power and check that the power has actually turned off.
There is a capacitor at the terminal, and it is particularly dangerous to touch it immediately after turning off the
power supply. Be careful of the electric charge of these capacitors and connect it to earth to discharge it
completely. Remove input line (AC line) during work.
WARNING

F-RA-001-5R0
◆Install horizontally.
Do not install the product in the reverse direction and the lateral direction. Internal heat dissipation becomes
insufficient, parts deteriorate, there is a risk of smoke and fire.
◆Do not install in the place where cool air blows directly.
There is a danger of condensation, leakage current and burnout.
◆Do not install the product in places around corrosive gas or liquid and places where chemicals handled.
There is a danger of parts being deteriorated, smoking and burning.
◆Avoid using it in a place with much dust.
If dust accumulates in the air inlet, remove it promptly.
If dust accumulates in the air inlet, cooling of the product is hindered and it may cause malfunction.
◆Do not block intake port and exhaust port.
Secure more than 30cm space on the front and back of the product.
If the intake port and exhaust port are blocked, the specified performance of the product cannot be demonstrated
and parts are deteriorate, which may cause smoke and fire.
◆When work such as welding is conducted near the product, disconnect all the wires from the product.
◆Do not wipe with chemicals (thinner etc.) or wet cloth.
There is a danger of electric shock, electric leakage, burnout from chemicals or water entering the inside of the
product.
◆About fan replacement
In the case of products with air-cooling fans, the fan has a lifetime part. As wear, deterioration, etc. progress with
the lapse of use time, operation may become unstable. Also note that the lifetime of fan varies greatly depending on
the environment where it is used (temperature, humidity, dust, etc.). In order to use the product for a longer time,
it is necessary to replace the fan periodically. For replacement, please contact our sales office (replacement require
separate repair charges). Do not exchange fans with other users because there is a danger of electric shock, etc.
CAUTION

1 Introduction
1-1 Introduction
1-2 Unpacking the amplifier
1-3 Environmental requirements
1-4 Points to be careful about in handling and care
1-5 Additional point to be noted for operation of HV amplifier
1-6 Troubleshooting
2 Product List
3 Exterior view diagram
4 Instructions for operation
4-1 Overview
4-2 Operation
4-3 Using the bias
4-4 Output voltmeter
4-5 Voltage monitor
4-6 Output current monitor
4-7 Output peak current
4-8 Remote ON/OFF switch (LS)
4-9 Other functions
a. Power outage protection
b. Over voltage protection(O.V.P)
c. Over current protection
d. Over temperature protection
4-10 Output Range
5 Optional features
5-1 List of optional features
Technical note (Current of capacitive load)
Page
1
1
1
2
3-5
6
7
8,9
10
10,11
12
12
12
13
13
14
15
15
15
15
16
17
18
Table of Contents
Table of Contents


1
1-1 Introduction
Thank you very much for your purchase of our product, HIGH VOLTAGE AMPRIFIER.
We have done our best for the quality control of our products. Please handle this unit
properly according to this instruction manual so that you can use the full performance of
this unit safely for long.
We have carefully prepared this instruction manual, but if you find any doubtful or
unclear point or any omission, please kindly contact us shortly.
1-2 Unpacking the amplifier
When unpacked the unit, you will please check the following accessories are enclosed with
the amplifier main body.
〈Accessories〉
・AC input cord (1 pc.)
・Instruction manual (1 pc.)
・Output cable (1 pc.)
1-3 Environmental requirements
・Place and use the high voltage amplifier horizontally.
・Never place any object on the high voltage amplifier.
・There are air suction and exhaust holes for cooling at upper part and sides of the high
voltage power supply. Provide an ample space to the high voltage power supply, and use
it at the place where the ventilating condition is good.
・Avoid using the unit at such places where it is very dusty or there is corrosive gas.
1 Introduction
1 Introduction

2
1-4 Points to be careful about in handling.
WHEN TOUCHING LOAD AFTER TURNING OFF HIGH VOLTAGE
1. Make the setting of an output voltage to zero (0). Turn off the HV ON/OFF switch.
2. Check and confirm that the voltage is zero at an output voltmeter of this unit.
3. Turn off the POWER ON/OFF switch.
4. Earthling an output for more than 10 seconds, check and confirm that the voltage is
zero with another high voltage meter. It is especially dangerous that the load is
capacitive or a long cable is used.
5. Make it a rule to touch load with right hand.
How to GROUND
・For the safe operation, be sure to ground the ground terminal of power supply at
one point.
If the Load frame is not grounded
If the Load frame is grounded
・Make sure to ground properly as per the above sketch Insufficient ground can cause electrical shock
or serious damage to the unit.
・In case output short circuit or arcing is expected, please make the ground wire shorter and thicker.
1 Introduction
output cable
ground terminal
ground
load frame
load
Wires should be :
・more than 5SQ
・less than about 2m
・Not bared wire
Ground at one point
rack –mount case
output cable
ground terminal
load frame
load
Wires should be :
・more than 5SQ
・less than about 2m
・Not bared wire
Ground at one point
rack –mount case

3
1-5 Additional points to be noted for operation of HV amplifier
(1) Keep the length of output cable as short as possible.
(2) Keep the output cable away from floor, desks, or metal objects.
(3) Have no shielding on the output cable.
Due to the character of HV amplifier, the output cable of the unit is not shielded. If the
output cable has some stray capacity against ground (earth or metal object), output
voltage will be sinusoidal or step waveform and extra current will be drawn. As this
current draw parallel to load, the following appearance might be happened.
①Rated maximum voltage or current cannot be obtained.
②The waveform at constant current operation or current monitor is
distorted or changed
View of high - voltage
amplifier’s charge and discharge current
1 Introduction
High-voltage
amplifier
AMPS series
Output line
Current monitor
Wave form
Results in
Over shooting
Vcon
io
lo
C
Vout
V
t
When there is output stray capacity C, the leak current by C will be as below.
io = = C Q: capacity (C)
Load
When using this unit as a high speed and high voltage amplifier(except when
DC mode), make sure to have proper connection to make the stray capacity of
HV output line as low as possible.
Solution
dQ
dt
dV
dt

4
Capacitive Load
When operated with a capacitive load of more than 100pF (including floating capacity of
output cable), the output might oscillate. In such a case put a high voltage resister of 100Ω
(0.1μF) to 1kΩ (1000pF) in series to output. Please also note that with capacitive load the
bandwidth is limited according to the formula below.
Frequency Response
In case clear output waveform is required, please select a HV amplifier which has high
enough frequency bandwidth against required frequency.
In general 3 to 5 times more frequency bandwidth for sinusoidal waveform, and about 10
times more for rectangular waveform, is required. In case of insufficient frequency bandwidth
the output swing shall be reduced, and also the phase difference be large, so some solutions,
such as monitoring output waveform, shall be required.
Rise Time (step responsibility)
Responsibility can be indicated with rise time. (fig.2) Usually the rise time of amplifier of
responsibility (= bandwidth) fc (Hz) is given by a formula below.
tr ≒0.35/fc
The rise time tf is equals to tr.
1 Introduction
100%
DC
0dB
3dB
0.01fc 0.1fc 0.5fc fc
f(Hz)
70%
92%
0
Output swing →
(Vpp)
Frequency ratio against fc
→
(fig.1) Declination of output swing by
frequency
Vcon-in
90%
100%
tf
tr
10%0%
0%
HVout
(fig.2)

5
Slew Rate
The responsibility of our high speed amplifier is determined with slew rate (SR). The step
responsibility of our amplifier is as shown in fig.3.
SR = △V/μS In case of output amplitude is smaller the response time become shorter.
For example, AMPS-20B20 reach to greater than SR = 1200V/μS at maximum.
FOR SAFER OPERATION
1. It will be safer if place an insulation plate which can withstand the voltage to be used
on the floor, and operate standing on it.
2. Operate the unit and load with left hand, and let right hand free from them.
3. After turning off the voltage (even long time after turning off), be sure to earth the
output more than 10 seconds before you touch the load.
1 Introduction
Vocn-in
HVout
1μS
1200V
(fig.3) (AMPS-20B20)

6
1-6 Troubleshooting
・In case no output voltage:
1. Check input voltage is correct
・230V AC ±10% 50/60Hz single phase of input voltage.
・Control voltage –10V to 10V at the time of controlling over external voltage.
2. Check whether or not the over current protection is effective.
(Refer 4-9-c. Over current protection (page 15) for the details)
3. Check whether or not the over temperature protection is effective.
(Refer 4-9-d. Over temperature protection (page 15) for the details)
・In case there is sounds of discharge around HV output section:
1. Check the plug section(arrow mark below) is not tainted or get dirty. If HV connector
is tainted and used, arcing may occur. Wipe it with liquid such as alcohol, and dry it
well before use.
NOTE : At operating frequencies above a few kHz, the operating noise
of the amplifier may be heard from inside the power supply,
but this is not a malfunction.
1 Introduction

7
Model
Output
Voltage
[V]
Output
Current
[mA]
Peak
Current
[mA/1mS ]
Slew
Rate
[V/μS]
Frequency Response
Dimension
[mm]
Full scale
[kHz]
10% of F.S
[kHz]
AMPS-0.4B2000
-400~+400
±2000
±4000
400
DC~100
DC~200
266Hx483Wx610D
AMPS-0.6B2000
-600~+600
±2000
±4000
500
DC~100
DC~200
AMPS-2B200
-2k~+2k
±200
±400
1000
DC~80
DC~160
266Hx483Wx550D
AMPS-5B80
-5k~+5k
±80
±160
DC~50
DC~100
AMPS-10B40
-10k~+10k
±40
±120
1200
DC~20
DC~40
AMPS-20B20
-20k~+20k
±20
±60
DC~10
DC~20
2Product List
2 Product List

8
3-1 Front view
①POWER ON/OFF switch ⑥Bias voltage setting dial
②HV ON/OFF switch (10-turn potentiometer)
③Output voltmeter 3½digital meter ⑦Output current monitor terminal
④External voltage input terminal ⑧Output voltage monitor termina l
(Vcon-in terminal)⑨Remote ON/OFF switch terminal
⑤Bias voltage ON/OFF switch
【LOc、LCcoption】
①POWER ON/OFF switch ⑦Current limit setting dial
②HV ON/OFF switch (10-turn potentiometer)
③Output voltmeter 3½digital meter ⑧Over Current LED
④External voltage input terminal ⑨Output voltage monitor terminal
(Vcon-in terminal)⑩Remote ON/OFF switch terminal
⑤Bias voltage ON/OFF switch ⑪Output current monitor terminal
⑥Bias voltage setting dial
(10-turn potentiometer)
3 Exterior view diagram
3 Exterior view diagram
④
①
②
⑤
⑥
③
⑨
⑧
④
⑦
REMOTE
ON/OFF
IM
VM
①
③
②
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪

9
Rear view
【AMPS-0.4B2000、AMPS -0.6B2000】
①Output terminal
②GROUND terminal
③AC input terminal (input voltage 230VAC 1φ)
【AMPS-2B200、AMPS-5B80、AMPS-10B40、AMPS-20B20】
①Output connector
②GROUND terminal
③FUSE (7A:2B200/5B80、10A:10B40/20B20)
④AC Input connector / Input voltage AC230V 1φ
3 Exterior view diagram
AC230V
①
②
③
④
FUSE
10A
①
N L
GND
OUTPUT
Gnd NC Hi
②
③

10
4-1 Overview
This product is a high speed and high voltage bipolar amplifier developed using the
knowledge and expertise gained through long years of experience with high voltage.
This is highly reliable and high performance product with all solid state parts.
4-2 Operation
1. Connect the product as shown in the diagram below. For your safety, always be sure to
ground the GND terminal of the unit.
2. Connect the input AC line cable
Install the crimp-style terminal etc in the terminal of the input AC line cable,and install it in
the swithboard of commercial power supply .Connect the swithboard with
NEUTRAL = blue
LINE = brown
GND = yellow/green.
3. Turn on the POWER switch
Digital Panel Meter light up, and unit become stand-by mode. At this status, there is no
high voltage at output terminal.
4 Instructions for operation
4 Instruction for operation
OUTPUT
GND
Load
【Rear Panel】
VokV
GND
Io mA
POWER
HV
For a capacitive load,
check the output current.
When using at 1kHz or
higher, wire so that the
stray capacitance of the
output line is minimized.
Please read the instruction
manual
"introduction P3 1-5" and
"Technical note P19

11
4. Turn on the HV switch.
The red indicator will light up to indicate that the amplifier is ready for operation.
If steps 3. and 4. are performed in the reverse order, the unit will be left in stand –by
mode. In this case, turn the HV switch off and then turn it back on.
5. Output voltage(kV) can be controlled as constant voltage mode by inputting control
voltage to Vcon-in .(input impedance of Vcon-in is 10kΩ)
The input frequency is within the range of the frequency characteristics in the table in Chapter 2.
Above the input voltage ±10V and the frequency, the output voltage amplitude is attenuated.
With a capacitive load, the maximum operating frequency may decrease depending on the
charge / discharge current. For the load at the time of capacity, check the data on Page 19 and use
it so that it does not cause overcurrent.
Vcon-in
voltage
Output voltage
AMPS-
0.4B2000
AMPS-
0.6B2000
AMPS-
2B200
AMPS-
5B80
AMPS-
10B40
AMPS-
20B20
-10V
-400V
-600V
-2kV
-5kV
-10kV
-20kV
0V
0V
0V
0V
0V
0V
0V
+10V
+400V
+600V
+2kV
+5kV
+10kV
+20kV
4 Instructions for operation
POWER
HV

12
4-3 Using the bias
Turning the bias voltage ON/OFF switch to the ON position makes it possible to vary bias
voltage using the BIAS knob. Read the setting voltage from the scale on the knob.
4-4 Output Voltmeter
There is a meter on the front panel for displaying the output voltage. Since it is an average
value display, it displays correctly for DC, but displays the average value for AC waveforms.
4-5 Voltage monitor
When the output voltage has been set to maximum output, 10 volts (+10 volts for positive
output, -10 volts for negative output) is output from the output voltage monitor terminal on
the front panel. Output impedance is 1KΩ
Max Bandwidth is over 50kHz .
Scale
Output voltage
AMPS-
0.4B2000
AMPS-
0.6B2000
AMPS-
2B200
AMPS-
5B80
AMPS-
10B40
AMPS-
20B20
000(ccw)
-400V
-600V
-2kV
-5kV
-10kV
-20kV
500
0V
0V
0V
0V
0V
0V
1000 (cw)
+400V
+600V
+2kV
+5kV
+10kV
+20kV
4 Instructions for operation
V
M
【Front Panel】
Vm=±10V / Vout=±rated voltage

13
4-6 Output current monitor
10V(positive output→+10V, negative output→-10V) is output from the front panel output
current monitor when operated with rated output peak current.
The output impedance is 1kΩ
Up to 5kHz Bandwidth .
※For circuit reasons , noise of about 25kHz / 0.5Vp-p will remain at the output current monitor .
4-7 Output peak current
Output peak current of around 3 times * more than rating can be obtained.
It suppresses the distortion of waveform with capacitive load.
Peak allowable time is 1ms.
4 Instructions for operation
I
M
【Front Panel】
Max 1ms
Iout
Vout
60mApk
< 20mA
0
0
Im=±10V/Iout=±peak current
(all model )
Im=±5V/Iout=rated current
( model AMPS-0.4B2000, AMPS-0.6B2000)
( model AMPS-2B200, AMPS-5B80)
Im=±3.3V/Iout=rated current
( model AMPS-10B40, AMPS-20B20)
*around 2 times
/ model AMPS-0.4B2000, AMPS-0.6B2000
AMPS-2B200, AMPS-5B80
Ext. AMPS-20B20
If the peak current time is long or the
average current exceeds the rated
current, the current protection will be
effective and cut off.
In such cases, we recommend reducing
the peak time or voltage, or adding a
resistor in series with the capacitive load
to reduce the peak current.