2
SAFTEY INFORMATION
---------------------------------------------------------------------------------------------------------------------------------------
This portable air conditioner must not be used in rooms under the following conditions:
- Potentially explosive atmosphere
- Aggressive atmospheres
- Featuring a high concentration of solvents
- An extremely high ratio of dust
Keep Children Away: Do not allow children to play with or around this unit, which could result in injury.
Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by
person (including children) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction concerning use of the
appliances by a person responsible for their safety.
Keep Unit Grounded: Always operate the unit with a grounded plug and a grounded electrical outlet.
A grounded plug is an essential safety feature that helps reduce the risk of shock or fire.
Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may
lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of
the same type and amperage rating.
Extension Cords: Extension cords must be grounded and able to deliver the appropriate voltages to
the unit.
Handle with Care: Do not drop, throw or crash the air conditioner. Rough treatment can damage the
components or wiring and create a hazardous condition.
Run on Stable Surface: Always operate the unit on a stable, level surface, for example the floor or a
strong counter, so that the portable air conditioner cannot fall and cause injury.
Keep Out of Water: Never operate the unit in pooled or standing water, as this may create a risk of
injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become
wet, thoroughly dry them before using the unit. If in doubt do not use the portable air conditioner and
consult a qualified electrician or a Meaco approved engineer.
Keep Air Intakes Clear: Do not clog or block the air intakes by placing the portable air conditioner too
close to curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and
result in a fire or electrical hazard.
Keep Electrical Components Dry: Never allow water inside the portable air conditioner’s electrical
components. If these areas become wet for any reason, thoroughly dry them before using the portable
air conditioner. If in doubt, do not use the portable air conditioner and consult a qualified electrician or
a Meaco approved engineer.
The operator must make the operating instruction available for the user and make sure that the user
does understand the manual.

3
The MeacoCool MC Series 12000 BTU, 12000CH BTU, 14000 BTU and 14000CH BTU
portable air conditioners use the new R290 refrigerant gas to comply with European
Environmental Directives. R290 is kinder to the environment and is part of attempts to
reduce global warming as it has a low greenhouse effect (GWP).
When using the MeacoCool MC Series portable air conditioner you must take into account the following:
•This portable air conditioner uses about 240 grams of R290 refrigerant in the 12000 BTU and
12000CH BTU model and 270 grams of R290 refrigerant in the 14000 BTU and 14000CH BTU
model, which is flammable. Therefore, it is part of a sealed system and must only be serviced
by a trained Meaco engineer.
•Do not use or store this portable air conditioner in a room smaller than 4m² to prevent a fire or
explosion hazard if there is a leak of refrigerant and the gas comes into contact with an ignition
source.
•Do not use in a room with any continuous sources of ignition, for example open flames, gas
fires or hobs, cigarettes or any other sources of ignition.
•If the portable air conditioner is installed, operated or stored in a non-ventilated area, then the
room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of
fire or explosion due to ignition of the refrigerant caused by electric heaters, cookers, or other
sources of ignition.
•R290 refrigerant gas is odourless.
•Do not puncture either during the units working life or after. At the end of life dispose of following
local recycling regulations.
•If there is any damage to the portable air conditioner then do not use it and contact Meaco or
your retailer.
•As with all portable air conditioner, always keep upright and leave the portable air conditioner
standing upright for eight hours before using it upon receipt.
Failure to comply with these instructions could result in fire, damage to property, serious
injury or potentially death.
Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued
by a national accredited organisation that ensures competence in handling flammable refrigerants
according to a specific evaluation recognised by national associations in the industry and compliant
with the latest R290 guidance.
Servicing should only be carried out by a Meaco approved engineer using original Meaco parts to
prevent damage to the unit and potential injury to the engineer.

4
WIRING INSTRUCTIONS
---------------------------------------------------------------------------------------------------------------------------------------
Should it be necessary to change the plug, please note the wires in the mains lead are
coloured in accordance with the following code:
BLUE –NEUTRAL
BROWN –LIVE
GREEN AND YELLOW –EARTH
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows:
1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with
the letter N or coloured BLACK.
2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with
the letter L or coloured RED.
3. The GREEN/YELLOW is the EARTH and must be connected to the terminal which is marked
with the letter E or coloured GREEN or GREEN/YELLOW.
4. Always ensure that the cord grip is positioned and fastened correctly.
5. Only ever use the same fuse as fitted in the original product, if in doubt please contact Meaco
first, or a qualified electrician.
Example wiring for a Standard British Plug:
Please note: The Earth Terminal is marked with the letter E or Earth Symbol .

5
PRODUCT IDENTIFICATION
---------------------------------------------------------------------------------------------------------------------------------------
Along with the portable air conditioner the box will contain the following: a duct, a duct machine adaptor,
a duct window adaptor, a drainage hose, a remote control and a window kit (for sash windows and
sliding doors). If at any point certain parts are damaged or lost, replacement parts are available to
purchase at www.meaco.com. If you require a different type of window kit (e.g. for windows which open
at an angle) please visit www.meaco.com or contact us on 01483 234900.
Duct
Duct Machine
Adaptor
Duct Window
Adaptor
Remote
Control
Drainage Hose
Window Kit
Control panel
Air outlet with
louvres
Air inlet
Handle
Air
exhaust
Power cord
Draining opening
with sealing plug
Other manuals for MeacoCool MC Series
2
This manual suits for next models
4
Table of contents
Other Meaco Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual