VERY IMPORTANT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. READ AND KEEP IN
MIND ALL INSTRUCTIONS AND RECOMMENDATIONS DESCRIBED THROUGHOUT THIS MANUAL.
- Only a qualified technician can install, adjust and maintain this baby changing station. Any operations
performed on the changing station must be compliant with the safety laws and regulations, both
European and local, that are in force at the time. Mediclinics S.A. is not liable for damages caused by
the improper installation, poor maintenance or misuse of this baby changing station.
- It is very important that, once installed and put into operation, the baby changing station is periodically
inspected in order to ensure that it remains firmly secured to the wall and it has not suffered any
damage that may cause any harm to users. It is very important to make sure that the baby changing
station opens and closes properly.
- Any additional component or spare part required for the baby changing station should only be
purchased from the manufacturer or from an authorized distributor.
- Under no circumstances may the baby changing station be used if there are indications that any part of
it is broken, torn or lost.
- The baby changing station must be secured to a wall capable of withstanding the loads to which it will
be subjected daily without a problem and the most appropriate wall fixings must be used for each type
of wall.
- The total maximum recommended weight for this changing station is 11 kg and babies up to 12 months
acc. to EN 12221-1:2008+A1:2013 Type 1. The changing station has been tested with a load of 50 kg
during 1 hour according to the point 5.7 of the EN 12221-2:2008+A1:2013 Standard. Excessive weight
may create dangerous or unstable situations for the baby.
- All assembly joints and wall fixings must always be properly tightened and inspected regularly to make
sure that they are properly fastened.
- It is very important to install the changing station away from sources of heat or open fire in order to
avoid the risk of fire.
- If the changing station is vandalized, it is very important to remove it from the wall and perform a
thorough inspection of the unit and the wall where it should be installed in order to detect and solve any
problem that may lead to an accident.
- For better comfort and safety, sanitary liners should always be available in the changing station and the
unit should be thoroughly cleaned daily in order to minimize the spread of infectious diseases.
- Under no circumstance should the baby be left unattended at any time on top of the baby changing
station.
- Always place the baby in the centre of the changing station.
- The baby changing station is designed to be used without any pillow. Please do not use pillow or any
other device that could affect the baby placement on the changing station.
ENGLISH
SAFETY INSTRUCTIONS
BEFORE YOU BEGIN

Required tools
You will need the following tools for the installation of the baby changing station:
Measuring tape in order to install the changing station
to the appropriate height and distance
Phillips Head Screwdriver in order to tighten the
fasteners of the changing station
A level in order for the changing station to be installed
completely horizontal to the ground
A pencil for the appropriate installation markings
A drill to make all the necessary holes for the
installation
1 Ø 10 mm masonry drill bit (a special drill for brick,
masonry or cement walls with widia tip).
Fixings supplied
The following fixings are supplied with the baby changing station:
Six self-tapping Philips screws (DIN 7981/C A2 of
Ø6.3x70 mm) for fixing the changing station to the wall
Six Ø10mm nylon plugs to insert into the installation holes
of the changing station
Four flat washers (DIN125 M8 A2) to be mounted with
four Ø6.3x70 mm self-tapping Philips screws below the
metal structure
Four blunt Philips screws (DIN7985 A2 M4x8 mm) to
fasten the liner dispenser to the metal wall structure
Four flat washers (DIN125 M4 A2) to be mounted with
four blunt Philips screws (M4x8 mm) to fasten the liner
dispenser
INSTALLATION INSTRUCTIONS

www.mediclinics.com
-13-
Step 1. Material inspection
It is very important to carry out a visual inspection of the packaging of the baby changing station in order to
ensure that it has not suffered any damage during transport and handling. If damage to the packaging is
found, the changing station should be carefully inspected to see if it has suffered any damage. UNDER NO
CIRCUMSTANCE SHOULD THE BABY CHANGING STATION BE INSTALLED IF ANY DAMAGE IS
FOUND.
Remove all packaging material and check if any assembly component (bed with wall installation structure
and sanitary liner dispenser) or any hardware component (see table of fixings supplied) is missing.
Step 2. Preparation of the installation surface
Once the material is unpacked and inspected, choose the area on the wall where the baby changing
station will be installed. It is very important to keep in mind and respect the operating distances indicated in
the figure below, which are 228 mm on either side of the chassis for fixing the changing station to the wall
and 570 mm of the changing station bed, when it is open, from the wall.
The recommended installation height is 800 mm from the ground to the lowest part of the changing station.
The following sketch shows the height at which the holes should be made in order for the changing station
to be installed at the recommended height:

Following the above scheme, using the pencil, mark on the wall the top two holes of the changing station's
holding structure. It is very important to make sure that the locations marked with the pencil for the
mounting holes are at the same level before drilling the holes.
Installation according to ADA regulations.
If it is required that the installation complies with the ADA regulations (USA), the installation should be
made taking into account the following installation dimensions.
Step 3. Installation of the changing station's bed and holding structure on
the wall.
Installation on brick, masonry or cement wall.
Using the masonry bit, make the two previously marked Ø10 mm holes for the top part of the changing
station, at a minimum depth of 70 mm.
Clean the dust off the two holes and insert the two Ø10 mm nylon plugs into them.
Screw two of the Ø6.3x70 mm mounting screws into the two previously placed plugs, without reaching the
bottom, leaving a gap of about 5 mm between the screw head and the wall.
Hang the changing station's holding structure from the two previously placed screws, making sure that the
unit is perfectly levelled. When you have made sure that the changing station is perfectly levelled, tighten
the top two screws completely.
Use the four lower holes of the changing station's holding structure as a guide to mark the position of the
remaining four holes.
Loosen the upper screws and remove the changing station.
Using the previously made markings as reference, drill the four lower holes with the Ø10mm drill at a
minimum depth of 70 mm.

www.mediclinics.com
-15-
Once completed, proceed with cleaning the holes and placing the remaining four Ø10 mm nylon plugs.
Put the changing station back on the top two screws and fix the structure to the wall with the four Ø6.3x70
mm screws and the four DIN125 M8 washers of the lower holes, then fully tighten the top two screws, the
distribution of the components is shown in the following figure:
Make sure that the six screws securing the unit to the wall have been properly tightened and that the
changing station is firmly fixed to the wall.
Installation on plasterboard or hollow wall.
The fixing systems supplied with this changing station are not suitable for installation on
plasterboard or hollow walls.
In order to install the unit on this type of wall, fastening anchors and tools specific for plasterboard or
hollow walls must be used.
Due to the problems posed by installations on this type of walls, with regard to fixing, it is recommended
that the installation is carried out by technicians specialized in installations on this type of walls. Mediclinics
is not responsible for the installation of its changing stations on plasterboard or hollow walls.
Step 4. Mounting the liner dispenser on the changing station holding
structure
Take the liner dispenser and, after verifying that it is not damaged or scratched, place it on the metal
structure following the sequence of steps shown below and thus ensuring its proper position with the metal
shafts.

Open the liner dispenser with the special key provided. The four holes for mounting the liner dispenser on
the holding structure of the changing station will be visible.
Fit the dispenser to the holding structure of the changing station and align the mounting holes of the
dispenser.
Fix the liner dispenser to the holding structure of the changing station using the four M4x8mm screws and
the four DIN125 M4 flat washers, as shown in the figure. Check and make sure it has been properly fixed.
Step 5. Final revision before commissioning
Thoroughly clean and disinfect the baby changing station. It is very important to verify that the unit opens
and closes smoothly and that no damage has been caused during installation of the changing. In
summary, it is very important to verify, once the installation of the baby changing station is complete, that it
is in perfect condition to be used without any problems.

www.mediclinics.com
-17-
Remember that any additional component or spare part required for the baby changing station should
only be purchased from the manufacturer or an authorized distributor.
COMPONENT
No.
CODE
Label
1
RC9691020SMD
Shock absorber CP0016H
2
RC9161001SMD
Lock + key
3
RC9483003SMD
Key
4
RC99065
Protective liners
5
CN0020
Shock absorber CP0016HCS
6
RC9161002SMD
BASIC EXPLODED VIEW

Proper preventive maintenance and careful cleaning are essential for an appropriate, clean and safe
product use.
For proper maintenance, follow these steps:
- Inspect the components of the baby changing station: make sure that there are no cracks, dents
or any other sign that would suggest any fault in the product.
- Inspect the opening of the station: open and close the tray, make sure that it doesn't open beyond
90° and that when raising the tray, once past 45°, it automatically closes completely. The
movements should be smooth and continuous, otherwise it is possible that the shock absorber is
not functioning properly.
- Inspect the wall mounting: it is one of the most important points, make sure that it is firmly fixed
and that there are no gaps or significant movement between the fixed portion of the changing
station and the wall.
- Inspect the fastening of the liner dispenser to the metal structure: open the dispenser cover and
check that the 4 fixing screws are tightened with their respective washers.
- Inspect the label: if it is missing, damaged, illegible or not properly attached, a new one should be
placed.
RECOMMENDATIONS FOR PREVENTIVE MAINTENANCE AND
CLEANING

www.mediclinics.com
-19-
Never leave a child unattended on top of the baby changing station.
This changing station is designed exclusively for babies up to 12
months of age and weighing less than 11kg.
Placing packages and/or accessories on top of the changing station
can destabilize it.
-
For proper cleaning, follow these steps:
- In order to avoid contact with the detergent, it is recommended to remove the liners from their
housing before cleaning.
- Clean all plastic pieces of the changing station using antibacterial soap.
- On the CP0016HCS model, avoid contacting the stainless steel front with the antibacterial soap; it
has to be cleaned with a standard stainless steel cleaner and a soft cloth.
- Remove the soap residue with a dry cloth, making sure that the cleaning has been effective and
that there are no residues of dirt or soap.
- After the changing station has been dried, put the liners back in their housing and close the front
cover with the lock.
- Carry out a final visual inspection to make sure that the baby changing station has been properly
cleaned.
- Leave the changing station in a closed position.
WARNING
Other manuals for CP0016H
1
This manual suits for next models
1
Table of contents
Other Mediclinics Baby & Toddler Furniture manuals
Popular Baby & Toddler Furniture manuals by other brands

DOM FAMILY
DOM FAMILY Skylar quick start guide

Combelle
Combelle Florian 2 quick start guide

babymoov
babymoov Moov & Comfy manual

Fisher-Price
Fisher-Price BFK72 quick start guide

ingenuity
ingenuity Disney Baby Minnie Mouse Garden Delights... manual

Delta Children
Delta Children Toddler Sleep Play Area Assembly instructions