BEFORE USE ....
Thank you for choosing us. Before use, check the contents of
the package you received as outlined below.
If you have any problems or questions with the product,please
contact our sales office or representatives.
n PACKAGE INCLUDES:
Standard rack...........................................................(1)
n MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
n INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.
POINTS OF CAUTION
n POWER INPUT RATING & OPERATIONAL RANGE
24 V DC ±10%, 2.5 A minimum
n ENVIRONMENT
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not apply physical impact to the unit.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with
cables, etc.
n WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
n AND ....
•The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
Specifications
(Side)
Body
MOUNTING REQUIREMENTS mm (inch)
101.6
(4.00)
*
450 (17.72)
465 (18.31)
4–M5 SCREW ANGLE BRACKET
Observe an appropriate wiring space over and below.
*
100 (3.94)
for JIS standard
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across terminals 1
(+) – 2 (–). Use a power source of ripple level 10% p-p or
less.
3) Installation & environment: Check ambient temperature.
Also check that there are no excessive dust particles around.
Check that there is no vibration.
STANDARD RACK