Middle Atlantic Products QUIET-COOL CLS-COOL1 User manual

Instruction Sheet
---------- c ls -c o o l
------------
Quiet-Cool SeriesTMCloset Cooler
CLS-COOL1
CLS-COOL2
THANK YOU
Thank you for purchasing the Quiet Cool Series™ CLS-COOL Closet Cooler. lease read these
instructions thoroughly thoroughly before installing / assembling this product.
PRODUCT FEATURES
- Extends equipment life.
- Quietly removes heat produced by electronic equipment.
- Thermostatically controlled fans run only when necessary.
- Attractive, solid oak vents can be stained or painted to match any decor. Middle Atlantic Products
I-00219 Rev B

SPECIFICATIONS
MODEL POWER
REQUIREMENTS FAN
QUANTITY CFM dBA @ 1 METER
CLS-COOL1 12VDC @ 200mA 2 50 25
CLS-COOL2 12VDC @ 400mA 4 50 28
PANELS
FRONT VENT PANEL
CLS-COOL1 - TOP PANEL
CLS-COOL2 - TOP / BOTTOM PANEL
15-3/4" [399mm]
f
5-3/4"
[146 mm]
_ L
FRONT VENT PANEL
CLS-COOL1 - BOTTOM PANEL
1-11/16"
[42mm] 15-3/4" [399mm]
1-11/16"
[42mm]
4-1/16”
[103^mm] □
(FRONT) (SIDE) (FRONT) (SIDE)
ACTIVE REAR PANEL
CLS-COOL1 - ACTIVE EXHAUST ANEL
CLS-COOL2 - ACTIVE EXHAUST / INTAKE ANEL
PASSIVE REAR PANEL
CLS-COOL1 - PASSIVE INTAKE PANEL
15-3/4" [399mm]
“ T
5-3/4"
[146 mm]
_ L
(FRONT)
1
J
(SIDE)
_ 1-1/4”
[31 mm] 15-3/4" [399mm]
f
4-1/16”
[103mm]
___
L
_ 9/16”
[15mm]
(FRONT) (SIDE)
INLINE FAN CONTROL
TOOLS REQUIRED
- DRILL
- 3/8" DRILL BIT
- JIGSAW
- #2 HILLI S HEAD DRIVER
age 2

PARTS
FRONT VENT PANEL
CLS-COOL1
CLS-COOL2
QTY
FRONT VENT PANEL
CLS-COOL1
CLS-COOL2
QTY
/
D D D D D D D D D D D D D D D D D D D D D D
\
ACTIVE EXHAUST PANEL (6 ft co d) QTY
CLS-COOL1
CLS-COOL2
CLS-COOL1
CLS-COOL2
PASSIVE INTAKE PANEL QTY
CLS-COOL1
CLS-COOL2
TEMPLATE
CLS-COOL1
CLS-COOL2
QTY
PLEASE READ All INSTRUCTIONS BEFORE USt THIS TEhFLATE.
_________
II
___________
ACTIVE EXHAUST PANEL (12 ft co d) QTY
WIRE TIE MOUNT
CLS-COOL1
CLS-COOL2
O
WIRE TIE
CLS-COOL1
CLS-COOL2
INLINE FAN CONTROL
CLS-COOL1
CLS-COOL2
POWER SUPPLY
CLS-COOL1
CLS-COOL2
i n n i = j
WOOD SCREW (6x3/8”)
CLS-COOL1
CLS-COOL2
SCREW (10-32x2”)
CLS-COOL1
CLS-COOL2
SCREW (10-32x1-1/2”)
CLS-COOL1
CLS-COOL2
age 3
QTY
5
10
QTY
5
10
QTY
1
1
QTY
1
1
QTY
2
2
QTY
4
8
QTY
2
0

INSTALLATION
1) Determine location for mounting your CLS-COOL.
NOTE: Rear Intake and Exhaust anels are labeled accordingly on the inside of the
panel.
RECOMMENDED INSTALLATION: Install Active Exhaust first at the highest point
availablein the door. Install assive / Active Intake second at lowest point available in
the door. (Template must be cut to trace for CLS-COOL1 assive Intake installation)
2) Using center lines as a guide, trace template on upper section of the door.
Mark four outer corner holes on the template ( © ).
3) Using a 3/8" drill bit, drill 4 clearance holes at pre-marked corner
holes to allow access for jigsaw.
4) Carefully cut out traced section of door.
5) Repeat steps 2 - 4 for the assive or Active Intake.
NOTE: For CLS-COOL1 assive Intake, cut the template as it shows.
(DO NOT cut template for CLS-COOL2 Active Intake)
6) lace wood panels on outside of door. (A second person may be required to hold wood
vent panels in place)
age 4

7) Attach rear panels using provided screws.
NOTE: For CLS-COOL2, position Active Exhaust anel with wire up. osition Active Intake anel
with wire down.
- For CLS-COOL1, use four 10-32x2 screws to attach Active Exhaust anel. Use two 10-32x1.5
screws
- For CLS-COOL2, use eight 10-32x2 screws to attach Active Intake anel and Active Exhaust
anel. A SNUG SCREWS EVENLY A
ACTIVE EXHAUST
PANEL
PASSIVE INTAKE
PANEL
CLS-COOL1
(REVIEW)
ACTIVE EXHAUST
PANEL
ACTIVE INTAKE
PANEL
CLS-COOL2
(REVIEW)
TIP: If using a raised or recessed panel door, cosmetic fillers or trimming may be required.
COSMETIC
FILLER MOLDING / TRIM
age 5


INLINE FAN CONTROL OPERATION
- Jumper on two center pins (factory setting) fan will turn on at 87° and turn off at 85°.
- Jumper on two left pins, fan will remain off.
- Jumper on two right pins, fan will remain on.
9) lug ower Supply into power source.
10) lug Active Fan anels into input one and / or two on Inline Fan Control. lug ower Supply into
power input.
ACTIVE FAN PANEL(S) CABLES
POWER SUPPLY
U
INLINE FAN CONTROL
11) With cabling installed, determine mounting location for Inline Fan Control.
NOTE: Inline Fan Control MUST be mounted at the highest available location.
12) Remove all cables from Inline Fan Control
13) Install Inline Fan Control at predetermined location using provided Wood Screws
14) lug Active Fan anels and ower Supply to Inline Fan Control.
- THE CLS-COOL IS NOW READY FOR USE -
age 7

WARRANTY
Middle Atlantic roducts (the "Company") warrants the CLS-COOL Closet Cooler to be free from
defects in material or workmanship under normal use and conditions for a period of (3) years from
date of shipment by the Company.
The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and
exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of
and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products
purchased, or any part or parts thereof, which the Company has determined to be defective after
inspection thereof at the Company's factory.
This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by
parties other than the Company, or any modification or alteration of the products. In addition, this
warranty does not cover damage due to improper handling, assembly, installation or maintenance.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EX RESSED OR
IM LIED, INCLUDING, BUT NOT LIMITED TO, IM LIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A ARTICULAR UR OSE.
TO THE MAXIMUM EXTENT ERMITTED BY A LICABLE LAW, IN NO EVENT SHALL THE COM ANY
BE LIABLE FOR ANY S ECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS ROFITS,
BUSINESS INTERRU TION OR ANY OTHER ECUNIARY LOSS) ARISING OUT OF THE USE OF THE
RODUCTS URCHASED, EVEN IF THE COM ANY HAS BEEN ADVISED OF THE OSSIBILITY OF
SUCH DAMAGES. THE COM ANY'S LIABILITY TO THE URCHASER (OR ANY OTHER ARTY)
HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE URCHASE RICE OF THE RODUCTS
AID TO THE COM ANY.
Co po ate Headqua te s
Corporate Voice 973-839-1011 - Fax 973-839-1976
International Voice +1 973-839-8821 - Fax +1 973-839-4982
middleatlantic.com - info@middleatlantic.com
Middle Atlantic Canada
Voice 613-836-2501 - Fax 613-836-2690
middleatlantic.ca - customerservicecanada@middleatlantic.ca
Facto y Dist ibution
USA: NJ - CA - IL Canada: ON - BC
At Middle Atlantic P oducts we a e always listening. You comments a e welcome.
Middle Atlantic P oducts is an ISO 9001 and ISO 14001 Registe ed Company.
age 8 30% Recycled Pape