Miele PW 6241 D User manual

PW 6241 D
Steam-heated
en Installation plan Commercial washing machine
cs Instalační plán Profesionální pračka
hu Telepítési terv Ipari mosógép
pl Plan instalacyjny Pralnica profesjonalna
pt Plano de instalação Máquina de lavar roupa industrial
tr Kurulum planı Endüstriyel Çamaşır Makinesi
M.-Nr. 12 168 530

2
en ...................................................................................................................................... 4
cs ....................................................................................................................................... 21
hu ...................................................................................................................................... 38
pl ....................................................................................................................................... 56
pt ....................................................................................................................................... 74
tr ........................................................................................................................................ 92

en - Contents
3
Installation notes............................................................................................................. 4
Explanation of the safety instructions and warnings on the machine............................... 4
Installation requirements ................................................................................................... 4
General operating conditions ............................................................................................ 4
Installation ......................................................................................................................... 4
Electrical connection......................................................................................................... 5
Water connection .............................................................................................................. 6
Cold water connection .................................................................................................. 7
Hot water connection.................................................................................................... 7
Hard water connection.................................................................................................. 7
Drain valve..................................................................................................................... 7
Dispenser pump connections ........................................................................................... 8
Optional accessories......................................................................................................... 9
BSK = Payment system kit............................................................................................ 9
BSS peak-load negotiation kit ...................................................................................... 9
XKM RS232 communication module ............................................................................ 10
Vapour and foam venting kit (APWM063) .................................................................... 10
Installation........................................................................................................................ 11
Installation (indirect steam heating)................................................................................... 11
Installation (direct steam heating)...................................................................................... 13
Installation........................................................................................................................ 15
Dimensions........................................................................................................................ 15
Standard floor anchoring................................................................................................... 16
SOM floor anchoring ......................................................................................................... 16
Technical data.................................................................................................................. 17
Voltage versions and electrical data.................................................................................. 17
Connection for equipotential bonding........................................................................... 17
Steam connection ............................................................................................................. 17
Water connections ............................................................................................................ 18
Cold water connection .................................................................................................. 18
Hot water connection.................................................................................................... 18
Hard water connection.................................................................................................. 18
Condensate connection (indirect steam heating only) .................................................. 18
Waste water (drain valve)............................................................................................... 18
Securing the machine........................................................................................................ 18
Fittings........................................................................................................................... 18
Emissions .......................................................................................................................... 19
Machine data..................................................................................................................... 19
Transport data ................................................................................................................... 19

en - Installation notes
*INSTALLATION*
4
Explanation of the safety instructions and warnings on the
machine
Read the operating instructions
Read all the instructions, e.g. the installation instruc-
tions
Warning, hot surfaces
Warning, voltage up to 1000volts
Earthing
Equipotential bonding
Installation requirements
The washing machine must be installed and commissioned by a
MieleService technician or by an authorised dealer.
The washing machine must be installed in accordance with applic-
able regulations and standards. Local energy supplier and water au-
thority regulations must also be observed.
This washing machine must only be operated in a room that has
sufficient ventilation and which is frost-free.
This machine should not be installed or operated in any area where
there is a risk of explosion!
General operating conditions
This washing machine is intended only for use in a commercial envir-
onment and must only be operated indoors.
- Ambient temperature: 0-40 °C
- Relative humidity: non-condensing
- Maximum height above sea level of location site: 2000 m
Depending on the nature of the installation site, sound emissions and
vibration may occur.
Tip: Have the installation site inspected and seek the advice of a pro-
fessional in instances where increased noise may cause a nuisance.
Installation
Transport the washing machine to its installation site using a suitable
pallet truck and remove the transport packaging.

en - Installation notes
*INSTALLATION*
5
The washing machine must be set up on a completely level, hori-
zontal and firm surface with the minimum stated load bearing capa-
city (see “Technical data”).
Tip: A concrete floor is the most suitable installation surface. It is far
less prone to vibration during the spin cycle than wooden floorboards
or a carpeted surface.
The floor load created by the washing machine is the load exerted
by the area of the machine in contact with and transferred to the in-
stallation footprint.
The washing machine requires a gap of at least 50mm at each side
to allow for movement during operation. Please ensure a minimum
distance of 1800m is maintained between the machine and the rear
wall.
The washing machine must not be installed on a carpeted floor.
The feet of the washing machine must be secured to the 4 fastening
points on the floor using the fittings supplied.
The fittings supplied are for bolting the machine to a concrete floor.
If other floor types are present at the installation site, the fastening
material must be ordered by the customer.
The base frame of the washing machine contains four drilled holes
through which it is possible to drill straight into the floor.
Electrical connection
The electrical connection must only be carried out by a qualified
electrician who must ensure that all electrical work is carried out in
accordance with applicable electrical regulations and standards
(BS 7671 in the UK).
This washing machine must be connected to an electrical mains
supply that complies with local and national regulations. Please also
observe your insurance and energy supplier's regulations as well as
any health and safety at work regulations.
The required voltage, connected load and fusing rating can be
found on the data plate on the washing machine. Before connecting
the machine to the power supply, please ensure that the mains sup-
ply voltage complies with the values given on the data plate.
Connection to a supply voltage other than the one quoted on the
data plate can lead to functional faults and damage the washing
machine!
If more than one voltage is quoted on the data plate, the washing
machine can be converted for connection to the voltages stated.
Conversion to a different voltage must only be carried out by a
Miele Service engineer or by an authorised Service Dealer. The wiring
instructions given on the wiring diagram must be followed.

en - Installation notes
*INSTALLATION*
6
Tip: We recommend connection to the power supply via a suitably
rated plug and socket which must be easily accessible for servicing
and maintenance work after the machine has been installed. An elec-
trical safety test must be carried out after installation and after any
service work.
The machine can either be hard-wired or connected using a plug-
and-socket connection in accordance with IEC 60309-1. For a hard-
wired connection an all-pole isolation device must be installed on
site.
For hard-wired machines connection should be made via a suitable
mains switch with all-pole isolation which, when in the off position,
ensures a 3mm gap between all open contacts. These include cir-
cuit breakers, fuses and relays (IEC/EN60947).
If the mains supply cannot be permanently disconnected, the isolator
switch (including plug and socket) must be safeguarded against be-
ing switched on either unintentionally or without authorisation.
If it is necessary to install a residual current device (RCD) in ac-
cordance with local regulations, a residual current device typeB
(sensitive to universal current) must be used.
An existing typeA residual current device (RCD) must be exchanged
for a typeB RCD.
An equipotential bond with good contact connection must always
be provided in accordance with all national and local regulations.
Accessories for equipotential bonding are not supplied and need to
be ordered separately.
Water connection
According to national regulations for drinking water quality, with ef-
fect from 21 March 2021, a non-return valve to prevent backsiphon-
ing must be fitted between the stopcock and the water inlet hose
during commissioning on all appliances in Germany. The non-return
valve prevents water from the water inlet hose from flowing back
into the on-site drinking water supply.
Non-return valves are supplied.
The flow pressure must amount to a minimum of 100kPa and must
not exceed 1000kPa. If the flow pressure is higher than 1000kPa, a
pressure reducing valve must be used.
The machine must be connected to the water supply using the inlet
hoses provided.
The connection points are subject to water supply pressure.
Turn on the stopcock slowly and check for leaks. Correct the posi-
tion of the seal and screw thread if appropriate.

en - Installation notes
*INSTALLATION*
7
The use of rubber or plastic tubing as pressure connection piping
between the installation location interior and the machine is only per-
mitted if:
- in conjunction with connection fittings, it can withstand a minimum
permanent pressure of 1500kPa (15bar),
- it is satisfactorily inspected during commissioning and
- after each use of the machine the water supply is reliably cut off be-
fore the rubber and plastic piping and put out of service or cut off
from the location interior.
Cold water con-
nection
For the cold water connection one stopcock each with a
3/4" external thread is required. A connector (Y-piece) can be used if
required to connect 2water inlet hoses with a ¾" screw thread to a
single stopcock with a 1" male thread.
The water inlet hose for cold water (blue stripes) is not intended to
be used with a hot water connection.
Hot water con-
nection To minimise energy consumption during operation with hot water,
the washing machine should be connected to a suitable hot water
ring circuit.
So-called “transmission pipes” (single pipes to hot water generators)
can result in cooling down of the water remaining in the pipes if not
in constant use. More energy would then be consumed to heat the
suds up again.
Use the inlet hose supplied (red stripes) for the hot water connection.
The temperature of the water intake must not exceed 60°C.
If there is no hot water supply at the installation location for the wash-
ing machine, the inlet hose for hot water must also be connected to
the cold water supply. A Y-piece is required in this case. The cold wa-
ter consumption increases accordingly to account for the missing hot
water intake.
For functional and technical reasons it is not possible to operate
the machine exclusively with a hot water connection.
Even if a hot water connection is present, the washing machine
must be connected to a cold water intake.
Hard water con-
nection
Connection for hard water. For the hard water connection, the same
requirements apply as for the cold water connection.
If there is no hard water connection on site, the hose must be con-
nected to the cold water connection.
Drain valve In the case of washing machines with a drain valve, a motorised valve
is used to drain the machine. An HTDN70 angle connector can be
used for draining the machine directly into the waste water system
(without a siphon) or into an on-site floor drain (with odour trap).

en - Installation notes
*INSTALLATION*
8
Thanks to an improved closing mechanism and a larger cross-sec-
tion, even the coarsest of soiling does not leave any deposits or
debris behind which could result in blockages. The drain valve can
also be operated manually to allow the suds container to be emptied
in the event of a power outage.
A vented drainage system is vital for unimpeded drainage.
If several machines are connected to a single drain pipe, this
should be sufficiently large to allow all machines to drain simultan-
eously.
The appropriate Miele installation kit (mat. no.:05238090) is avail-
able to order from the Miele Customer Service Department or your
Miele dealer for venting an HTDN70pipe.
If the slope for drainage is extremely steep, the piping must be ven-
ted to prevent formation of a vacuum in the machine’s drainage
system.
Slow or obstructed drainage or a backup of water in the drum as a
result of undersized pipework can result in faults occurring during
programmes, which will result in fault messages appearing in the dis-
play.
Outflowing suds can be as hot as 95°C. Danger of burning!
Avoid direct contact.
Dispenser pump connections
Up to 12dispenser pumps can be connected to the washing ma-
chine.
Dispenser pump connections on the back of the machine
Connections 1 and 2 are provided for viscous agents can also be
used for high pressure dispensing systems with water injection. The
dispensing systems must be fitted with a separate drinking water
safety mechanism in accordance with EN61770 and EN1717. The
maximum flow rate is 1500ml/min with a maximum flow pressure of
300kPa.

en - Installation notes
*INSTALLATION*
9
These connectors are sealed and need to be drilled open using a
8mm drill bit before connecting.
Make sure that you only drill through the first panel(I) as there is a
deflecting panel(II) 10mm behind it.
Connections3 to 12 are provided for liquid detergent. High pressure
dispensing systems with water injection must not be connected to
these connections. The connectors are sealed and must be cut to the
diameter of the hose with a small saw before they are connected.
If opened connectors are no longer required, they must be resealed
using a suitable sealant (e.g. silicone).
Connection terminals for five time-controlled dispenser pumps, which
can be operated without a multifunction module, are located behind
the cover adjacent to the electrical connection.
Calibration of the dispenser pumps and regulation of dispensing
quantities is carried out partly automatically for washing machines
fitted with an optional multifunction module. Information regarding
settings is given in the operating instructions.
A flowmeter or flow sensors can also be connected for monitoring the
dispensing quantity precisely.
Connections for level monitoring are available for every agent dis-
pensed.
Optional accessories
Only use genuine Miele spare parts and accessories with this ma-
chine.
Using spare parts or accessories from other manufacturers will in-
validate the guarantee, and Miele cannot accept liability.
BSK = Payment
system kit
The washing machine can be equipped with a payment system (e.g.
for self-service operations) using the optional BSK payment system
kit. This must be connected and programmed by a Miele Service
technician. Payment systems with mechanical or electronic coin val-
idator are available from Miele as optional accessories for individual
target groups.
The programming required for connecting a payment system must
be carried out by Miele Service or an authorised Miele dealer only. A
separate electrical connection is not required for a payment system.

en - Installation notes
*INSTALLATION*
10
BSS peak-load
negotiation kit
The washing machine can be connected to a peak-load shut-off or an
energy management system using a BSS peak-load negotiation kit
which is available as an optional accessory.
The peak-load cut-out monitors the energy consumption of a sys-
tem and deactivates individual pieces of equipment temporarily in
order to ensure that certain total load limits are not exceeded. Monit-
oring is externally controlled.
The kit provides three signal contacts and a neutral conductor via a
terminal block. The terminal block is marked with “a”, “b”, “c”, and “d”.
aOutput signal, start of machine operation
bOutput signal, machine heating request
cPeak-load input signal, machine heating deactivated
dNeutral conductor
When the peak-load function is activated the current programme is
stopped and a message appears in the display on the washing ma-
chine. At the end of the peak-load function the programme resumes
automatically.
XKM RS232 com-
munication mod-
ule
The serial interface RS-232 can be retrofitted to the washing machine
via an XKMRS232 (optional accessory available from Miele). This
communication module must only be used with MieleProfes-
sionalmachines that are fitted with an appropriate slot for the mod-
ule.
The data interface provided via communication module
XKMRS232 complies with SELV (Safety Extra Low Voltage) in ac-
cordance with EN60950.
Appliances connected to this interface must also be SELV compli-
ant.
Communication module XKMRS232 is supplied with a connection
cable and a D-sub-connector.
Vapour and foam
venting kit
(APWM063)
If excessive suds form, foam may escape from the vapour vent. To re-
move the foam, an optional vapour and foam venting kit (BWS) can
be used.

en - Installation
11
Installation (indirect steam heating)
aElectrical connection
bCold water connection
cHot water connection
dCold water connection (alternatively, hard
water connection)
eCold water connection for liquid dispens-
ing (optional)
fDispenser pump connections
gOverflow
hCommunication connection
iDrain pipe
jConnection for equipotential bonding
kSI connection, intake (indirect steam) SI
only
lSI connection, drain (indirect steam) SD
only
mSD connection (direct steam) SD only
nSteam valve connection SI/SD only
oSteam valve SI/SD only

en - Installation
12
aElectrical connection
bCold water connection
cHot water connection
dCold water connection (alternatively, hard
water connection)
eCold water connection for liquid dispens-
ing (optional)
fDispenser pump connections
gOverflow
hCommunication connection
iDrain pipe
jConnection for equipotential bonding
kSI connection, intake (indirect steam) SI
only
lSI connection, drain (indirect steam) SI
only
mSD connection (direct steam) SD only
nSteam valve connection SI/SD only
oSteam valve SI/SD only
pWater recovery connection (optional)

en - Installation
13
Installation (direct steam heating)
aElectrical connection
bCold water connection
cHot water connection
dCold water connection (alternatively, hard
water connection)
eCold water connection for liquid dispens-
ing (optional)
fDispenser pump connections
gOverflow
hCommunication connection
iDrain pipe
jConnection for equipotential bonding
kSI connection, intake (indirect steam) SI
only
lSI connection, drain (indirect steam) SD
only
mSD connection (direct steam) SD only
nSteam valve connection SI/SD only
oSteam valve SI/SD only

en - Installation
14
aElectrical connection
bCold water connection
cHot water connection
dCold water connection (alternatively, hard
water connection)
eCold water connection for liquid dispens-
ing (optional)
fDispenser pump connections
gOverflow
hCommunication connection
iDrain pipe
jConnection for equipotential bonding
kSI connection, intake (indirect steam) SI
only
lSI connection, drain (indirect steam) SD
only
mSD connection (direct steam) SD only
nSteam valve connection SI/SD only
oSteam valve SI/SD only
pWater recovery connection

en - Installation
*INSTALLATION*
15
Dimensions

en - Installation
*INSTALLATION*
16
Standard floor anchoring
Dimensions in mm
screw/anchor point
SOM floor anchoring
Dimensions in mm
screw/anchor point

en - Technical data
17
Voltage versions and electrical data
Standard: Convertible to:
Supply voltage 3N AC 380-415V 3N AC 380-415V
Frequency 50 Hz 60 Hz
Power rating 4,3 kW 4,3 kW
Fuse rating (on site) 3 x 16 A 3 x 16 A
Connection cable, min. cross-section 4 x 1,5 mm² 4 x 1,5 mm²
Cable gland M16 x 1,5 mm M16 x 1,5 mm
Supply voltage 3 AC 400V
Frequency 60 Hz
Power rating 4,3 kW
Fuse rating (on site) 3 x 16 A
Connection cable, min. cross-section 4 x 1,5 mm²
Cable gland M16 x 1,5 mm
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock in accordance with
IEC60309 and IEC60947 so that electrical safety checks can be carried out easily.
For hard-wired machines, an isolator in accordance with IEC60947 must be installed.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are sensit-
ive to universal current (typeB).
Connection for equipotential bonding
Connection with male thread (machine) 10mmx30mm (3/8"x13/16")
Size of washers and nuts M10
An equipotential bond with good contact connection must always be provided in accordance with all national and local regulations.
Steam connection
Indirect steam heating
Steam overpressure 400–1000kPa
Boiling point 152–184°C
Heater rating (peak capacity) 50kW
Mass flow (peak capacity) 84kg/h
Threaded union (on site) ½"female thread
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Direct steam heating
Steam overpressure (high pressure) ≤400kPa
Boiling point (high pressure) ≤152°C
Heater rating (peak capacity high pressure) 86kW
Mass flow (peak capacity high pressure) 140kg/h
Steam overpressure (low pressure) ≤50kPa
Boiling point (low pressure) ≤120°C
Heater rating (peak capacity low pressure) 29kW
Heater rating (peak capacity low pressure) 45kg/h
Threaded union (on site) ¾"female thread
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.

en - Technical data
18
Water connections
Cold water connection
Required flow pressure 100–1000 kPa (1–10 bar)
Maximum flow rate (if no hot water and hard water supply) 74 (79,5*) l/min
Maximum flow rate 26 (31,5*) l/min
Threaded union required (to be provided by customer in accordance with DIN44991, flat seal-
ing)
3/4"
Length of water inlet hose supplied 1550 mm
*With liquid dispensing
Hot water connection
Maximum permissible hot water temperature 60°C
Required flow pressure 100–1000 kPa (1–10 bar)
Maximum flow rate 16 l/min
Threaded union required (in accordance with DIN44991, flat sealing) 3/4"
Length of water inlet hose supplied 1550 mm
Hard water connection
Required flow pressure 100–1000 kPa (1–10 bar)
Maximum flow rate 32 l/min
Threaded union required (in accordance with DIN44991, flat sealing) 3/4"
Length of water inlet hose supplied 1550 mm
Condensate connection (indirect steam heating only)
Threaded union for condensate connection (on site) ½"male thread
Condensate trap, dirt filter and steam shut-off valve must be installed by the customer on site.
Waste water (drain valve)
Maximum waste water temperature 95 °C
Machine-side drain connection (external diameter) HT DN 70
On-site drain (internal diameter) 75 x 1,9 x 110 mm (Muffe DN 70)
Maximum flow rate 200 l/min
A vented combined pipe is required to drain the waste water. If several machines are connected to a single drain pipe, this should be
sufficiently large to allow all machines to drain simultaneously.
Securing the machine
Fittings
4x wood screws DIN571 (Øxlength) 12 mm x 90 mm
4x plugs (Øxlength) 16 mm x 80 mm
Fixing the machine in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.

en - Technical data
19
Emissions
Average heat dissipation rate to installation room 4,7 MJ/h
Emission sound pressure level in the workplace 78 dB(A) re 20 µPa
Sound power level, washing 60,3 dB (A) re 1 pW
Sound power level, spinning 82,2 dB (A) re 1 pW
Machine data
Machine width 1085 mm
Machine height 1643 mm
Machine depth 1106 mm
Machine width, total 1089 mm
Machine height, total 1646 mm
Machine depth, total 1252 mm
Width of loading aperture (internal diameter) 1185 mm
Recommended wall spacing (up to the front edge of the machine) 1800 mm
Net weight 640 kg
Max. floor load in operation 8417 N
Maximum static load 7063 N
Maximum dynamic load 1353 N
Maximum rotation frequency of drum 18,3 Hz
Installation should only be performed by qualified fitters in compliance with valid regula-
tions, relevant standards and health and safety codes.
Transport data
Packaging width 1260 mm
Packaging height 1710 mm
Packaging depth 1470 mm
Gross weight 691 kg

cs - Obsah
20
Pokyny kinstalaci............................................................................................................ 21
Vysvětlení bezpečnostních pokynů a varovných upozornění na přístroji.......................... 21
Předpoklady instalace ....................................................................................................... 21
Všeobecné provozní podmínky ......................................................................................... 21
Umístění ............................................................................................................................ 21
Elektrické připojení............................................................................................................ 22
Připojení na vodu............................................................................................................... 23
Upozornění pro Švýcarsko ............................................................................................ 23
Pozor vRakousku.......................................................................................................... 23
Připojení na studenou vodu........................................................................................... 24
Připojení teplé vody....................................................................................................... 24
Přípojka tvrdé vody........................................................................................................ 24
Vypouštěcí ventil ........................................................................................................... 24
Připojení dávkovacích čerpadel ........................................................................................ 25
Zvláštní vybavení/ příslušenství kdokoupení................................................................... 26
Sada pro inkasní přístroj (BSK)...................................................................................... 26
Sada pro vypnutí při špičce (BSS)................................................................................. 27
Komunikační modul XKMRS232 .................................................................................. 27
Sada pro odvádění par a pěny (APWM063)................................................................. 27
Instalace........................................................................................................................... 28
Instalace (nepřímý parní ohřev) ......................................................................................... 28
Instalace (přímý parní ohřev) ............................................................................................. 30
Umístění ........................................................................................................................... 32
Rozměry ............................................................................................................................ 32
Standardní upevnění na podlaze....................................................................................... 33
Upevnění na podlaze SOM................................................................................................ 33
Technické údaje............................................................................................................... 34
Varianty napětí a elektrické údaje...................................................................................... 34
přípoj pro vyrovnání potenciálů ..................................................................................... 34
Připojení na páru ............................................................................................................... 34
Přípojky vody..................................................................................................................... 35
Přípojka studené vody................................................................................................... 35
Připojení teplé vody....................................................................................................... 35
Přípojka tvrdé vody........................................................................................................ 35
Připojení kondenzátu (jen při nepřímém parním ohřevu)............................................... 35
Odpadní voda (vypouštěcí ventil).................................................................................. 35
Upevnění ........................................................................................................................... 35
Upevňovací materiál...................................................................................................... 35
Emise přístroje................................................................................................................... 35
Údaje opřístroji ................................................................................................................. 36
Přepravní údaje.................................................................................................................. 36
Table of contents
Languages:
Other Miele Washer manuals

Miele
Miele W 487 WPS User manual

Miele
Miele W 820 User manual

Miele
Miele PWM509 User manual

Miele
Miele WKH 122 WPS User manual

Miele
Miele PG 8591 User manual

Miele
Miele W770 - User manual

Miele
Miele WS 5101 User manual

Miele
Miele W 5965 WPS User manual

Miele
Miele WS 5071 User manual

Miele
Miele Premier 300 User manual

Miele
Miele PWM 300 SmartBiz User manual

Miele
Miele Allerwash W 3574 WPS User manual

Miele
Miele PWM 912 SI User manual

Miele
Miele W1 User manual

Miele
Miele W 1716 User manual

Miele
Miele PWM 920 EL/RH User manual

Miele
Miele W 340 User manual

Miele
Miele W 3923 WPS User manual

Miele
Miele PW 6080 VARIO Manual

Miele
Miele WWV 980 WPS Passion User manual