Milk bar Premium Care User manual



Contents
FUNCTIONS & FEATURES 4
PARTS & DESCRIPTIONS 5
HOW TO CLEAN YOUR PUMP 6
PREPARING YOUR PUMP 8
HOW TO OPERATE YOUR PUMP 9
SAFE USE OF YOUR PUMP 13
TROUBLESHOOTING YOUR PUMP 15
IMPORTANT SAFETY INFORMATION 17
WARRANTY INFORMATION 18
TECHNICAL PARAMETERS 18

4
Functions and
FEATURES
PRODUCT FEATURES
Milkbar’s Premium Care double electric breast pump has our state of the art, 3-Phase
expression technology. The soft silicone breast shield is innovatively designed to ‘massage,
squeeze and suck,’ mimicking the way a baby naturally feeds, to help express more milk in
less time.
Milkbar’s Premium Care breast pump has four modes - stimulation, expression, auto mode
and a brand new power pump mode. Stimulation mode mimics the quick suckling action
that a baby uses to stimulate milk let down. The expression mode uses a long drawn-
out suckling action to help draw out the milk. The all-new power pump and auto modes
combine both expression and stimulation modes to help trigger more let downs and offer
more stimulation for increasing milk supply. Power pump mode cycles between stimulation
and expression whereas the auto mode is a pre-programmed 10 minute pump cycle.
• 3-phase expression technology
• Power Pump and Auto modes
• User Memory mode
• Ultra quiet pumping experience
• Screen-lock function
• Lightweight design for easy portability
• Modern design and touch button for convenient operation
• Triple power sources: Adapter / Built-in Lithium battery /
USB-C Port
• Button mute function for discrete breast pumping

5
GET TO KNOW YOUR PUMP BEFORE USING IT. INSPECT ALL PARTS, AND MAKE SURE YOU HAVE
EVERYTHING BEFORE YOU BEGIN.
01. Dust Cover x2
02. All-in-One insert in sizes 21mm,
25mm & 29mm x2 each
03. Breast Shield Body x2
04. Diaphragm x2
05. Cap x2
06. Tubing Connector x4
07. Power Adapter x1
*Plus spare parts: 2x tubing and 2x tubing connectors.
08. Tubing x2
09. Pump Unit x1
10. Wide Neck Bottle x2
11. Bottle Adapter x2
12. Nipple x2
13. Disc collar x2
14. Nipple Dust Cover x2
15. Bottle Lid x2
Parts and
DESCRIPTIONS
01
02 03
04 05
06 07
09
101112
13
14
15
08

6
How to
CLEAN YOUR PUMP
FIRST TIME USE
HOW TO CLEAN
• Disassemble the parts that come in contact with the breast
and breast milk (Parts 02, 03, 04, 10)
• Wash all of the parts in warm soapy water, using liquid
household detergent.
• Rinse each piece thoroughly with warm water for 10 to 15
seconds.
• Sterilise parts using:
~ Boiling water for 5 minutes,
~ A microwave or electric steam steriliser as per individual
instructions,
~ A UV steriliser as per individual instructions,
~ Milton Solution as per individual instructions.
* Please note Milton method of sterilising is not
recommended for silicone parts
• Rinse each part that comes into contact with the body and
or milk with cool water immediately after pumping. This
avoids build up of milk residue in the collection bottles and
parts to avoid the growth of any bacteria.
• Parts of the pump that come into contact with breastmilk
are the silicone insert, diaphragm, breast shield body, and
collection bottle. Wash all of them in warm soapy water
using liquid household detergent.
• Bottle parts such as nipple, nipple cover, disc collar and
bottle lid will also need cleaning if used.
• Use a dedicated cleaning sponge and bottle brush with a
smaller brush to gently clean the tiny nooks of the pump
parts. Wash the parts separately from other dishes such as
pots and pans etc.
• Rinse each piece thoroughly with warm water for 10 to 15
seconds. Sanitise parts using the sterilisation method of your
choice after every use.
• Always check parts for wear and tear.
YOUR MILKBAR PREMIUM CARE ELECTRIC BREAST PUMP COMES PRE-ASSEMBLED,
HOWEVER YOU NEED TO CLEAN IT BEFORE FIRST USE AND REASSEMBLE.

7
CARE OF PARTS • Excessive and frequent boiling or exposure to heat may
cause wear and tear to the plastic and silicone parts. These
parts can be replaced via www.milkbarnewzealand.com.
• Replace worn out or damaged parts immediately as this
may affect the suction. Take particular care of the soft
silicone insert valve as this is very thin silicone and can be
prone to damage during cleaning and use.
• Parts may be washed in the dishwasher using the top rack
only.
• Place all clean parts on top of a paper towel or hang on a
drying rack and allow to air dry.
• Avoid using cloth towels, as they can carry germs and
bacteria that may contaminate breastmilk.
• Ensure all parts are completely dry before use; wet or damp
parts will cause poor suction. Once parts are completely dry,
reassemble the breast shield set.
CLEANING THE TUBES • The Milkbar Premium Care breast pump has a closed system
therefore cleaning the tubes is not necessary. If you happen
to see moisture in the tubes after pumping, remove the
tubes from the cap and pump unit and allow to air dry until
all moisture is gone. Do not attempt to use the pump if there
is moisture in tubing, instead switch to the spare tubing
included with your pump.
CLEANING THE PUMP
UNIT • Sanitise your pump unit using any disinfectant wipes, by
wiping off the tubing connector points from time-to-time.
Wipe down the pump unit with a clean damp cloth or paper
towel prior to each use.
SAFETY
RECOMMENDATIONS • Wash your hands prior to touching the breast pump and the
breast pump parts.
• Avoid touching the inner part of a collection bottle where the
milk comes into contact.
• Wash all parts that come into contact with your breasts and
breast milk immediately after each use, to avoid the growth
of any bacteria from milk residue.
• Electrical pump units must never be exposed to water
or other liquids for cleaning. It must not be sterilised in a
microwave steriliser.
• Please note if you are a mother who is infected with hepatitis
B, hepatitis C or human immunodeciency virus (HIV),
pumping breast milk will not reduce or remove the risk of
transmitting the virus to your baby through your breast milk.

8
Preparing
YOUR PUMP
ASSEMBLING THE MILK COLLECTION KIT
ASSEMBLING PUMP UNIT AND MILK
COLLECTION KIT
ASSEMBLING PUMP UNIT AND ADAPTER
ASSEMBLING DIAPHRAGM
1. Insert silicone insert and valve (02) into
Breast shield body (03).
2. Do not hold the “V” part of the silicone
insert as this part is delicate. Hold the
thicker silicone above the valve and
attach the round part of the breast shield
body.
3. Seal the outer silicone shield over the rim
of the breast shield body ange.
4. Dust cover (01) can then be inserted into
the silicone insert if storing
5. Remove the dust cover before use.
Connect one end of the tube connector
(06) with the air vent of the cap (05) and
the other end with the pump unit (09).
Connect the USB-C Cable with pump unit
(09), then plug the adapter (07) into the
electrical socket.
Once it is connected with power source,
the display screen will ash to hint that it is
standby.
1. Insert diaphragm (04) into the top of
breast shield body
2. Then attach the cap (05) rmly to
prevent air leaks.
3. Twist the bottle (10) into the breast shield
body, securing it tightly.
Parts that come directly into contact with breastmilk such as silicone insert, diaphragm,
breast shield body and bottle all must be cleaned and sterilised before use.
YOUR MILKBAR PREMIUM CARE ELECTRIC BREAST PUMP COMES PRE-ASSEMBLED HOWEVER
YOU NEED TO CLEAN IT AND REASSEMBLE IT AFTER CLEANING BEFORE FIRST USE.
01
02
03
04
06
08
07
05
10
06
09
Mute Button
(Press + and -
to activate)

9
How to operate your
PREMIUM CARE BREAST PUMP
BEFORE EACH USE • Make sure the milk collection kit is clean and free from any
liquid
ON /OFF BUTTON
DISPLAY SCREEN • When (Stimulation phase) or (Expression phase) or
(Power Pump) or (Auto Loop) in the Display are lit: the
current breast pump phase is indicated.
• When in the display screen is lit: it indicates that the
“User memory mode” is activated;
• When in the display screen is flashing: it indicates that
the pumping session is being recorded
• in the middle of display screen indicates the
duration of pumping session. When pausing the pumping
session, the will flash
Mute icon Child-lock icon
Battery power iconUser memory mode icon
Child lock
(Press + and -
to activate)
Speed
SuctionSuction
Speed
Phase: Stimulation / Expression /
Power Pump / Auto Loop
Pause / Resume
ON / OFF
User memory mode
Left / Right / Double Pumping
Mute Button
(Press + and -
to activate)
• Long press the button to turn on / off the pump unit
• The device will enter Stimulation mode at Level 1
• Short press the button to pause / resume the device

10
TIMER FUNCTION
• stands for suction and stands for speed
• For each Phase, the suction has 9 levels for adjustment
• For each Phase, the speed has 3 levels for adjustment
• When in the display screen is lit, it indicates that the
pump unit display is locked.
• In between using the breast pump, please turn off the pump
to conserve the battery power. Charge the device if possible
between each use or every 2-3 times of using to help
preserve the battery. When the battery is nearly exhausted,
the battery icon will flash and gives beep sound to remind
the consumer.
• Long press the ON/OFF button to turn on the pump, the timer
will begin to count up. The breast pump will turn off and
enter standby status when the timer reaches to 30 minutes
• When the breast pump is working, long press the ON/OFF
button to shut it down. The timer will reset to 0 minutes when
the breast pump is re-started.
• Press and hold the to enter “User memory” mode to start
recording the pumping session. Press and hold again to save
and exit the recording.
• Short press button to enter the “Memory function” of the
user memory mode.
• Short press again to exit the User memory mode .
• The previous memory will be reset if you long press the user
memory mode to record new pumping session.
USER MEMORY
MODES
LITHIUM BATTERY • The pump unit is able to be powered when the plug is
connected; when the plug is not connected, the pump unit is
automatically powered by the built-in lithium battery.
• The lithium battery takes around 4 hours to be fully charged;
after being fully charged, it can run for up to 200 minutes.
• When the battery power is drained, the pump unit will
• This function activates when you press the + and - at the
same time. The mute icon will display on the screen. Press
together again to deactivate.
BUTTON MUTE
• To activate the child lock function, press the + and the - at
the same time. The lock icon will display on the screen. Press
together again to deactivate.
CHILD LOCK

11
BEFORE YOU START • Upon receiving your Milkbar Premium Care electric breast
pump connects the power adaptor to the pump unit and
fully charge the pump unit. This will take around 3 to 4 hours.
This step is crucial for getting the most out of the battery life
of the lithium battery.
• Inspect breast shields, silicone inserts and tubing connectors
for damage before using your breast pump.
• ensure every part is attached properly and securely.
• Check there is no moisture and any parts of the collection kit.
KEEP IN MIND • If at any time you feel pain and discomfort, or if you are not
able to express milk, consult a breastfeeding specialist.
• Do not try to express with a suction level that is too high, this
may result in discomfort, pain and less milk output.
• Low or no suction does not always mean something is wrong
with your breast pump. Check all parts to ensure they are
connected correctly and there is no moisture and any of the
tubes or parts.
USING YOUR PUMP • Plug the power adaptor cord to the power outlet.
• Play the breast shield over your breasts, leaning forward
slightly so that your nipple is properly centred in the suction
kit. Make sure that you have the right size insert that matches
your nipple size.
• When ready, long press the power button to switch the
device on.
• The device is turned on the timer will show 0 minutes and
the stimulation phase will begin on suction level 1. The
stimulation mode is designed to mimic your baby’s initial
feeding motion and help trigger your milk ejection reex
(MER)/let down.
• Milkbar Premium Care breast pump has a pumping motion
design to massage, squeeze and suck just like an infant.
• Once your milk is owing and your let down has been
stimulated, you may manually press the expression button
to switch between stimulation and expression and back
again.
• Expression mode is set at suction level 1 by default - you may
adjust the suction level according to your need. Expression
mode is a slower motion with deeper sucking, which is how
an infant sucks after the breasts have released a good ow
of breast milk.
automatically stop to protect the lithium battery and
beeps to alert. When the battery is fully charged, it will stop
charging to avoid damage to the lithium battery.
• Recharge the pump unit once a month when it is in storage
or not being used frequently.

12
AFTER EACH
PUMPING SESSION • Label your container with the date and time the milk is
expressed.
• Name your container if breast milk is being given to a child
care provider.
• Refrigerate or chill your milk right after pumping unless using
within 2 hours.
STORING BREAST
MILK
FREEZING BREAST
MILK
THAWING AND
WARMING BREAST
MILK
• Breast milk can be stored in a clean bpa-free plastic bottle
with a tight tting lid.
• You can store your milk in our BPA-free Milkbar breast milk
storage bags or other BPA-free storage bags.
• Never store milk in the shelves of your refrigerator door,
instead choose a spot at the very back of the fridge where
the temperature is less affected by the door opening.
• Leave an inch of space at the top of a container as milk
expands as it freezes.
• Do not store milk in the door of your freezer, instead store
milk at the back of your freezer.
• Use the oldest stored breast milk rst.
• Breast milk does not need to be warmed - it can be served
at room temperature or cold if preferred.
• Gently swirl the container to mix the breast milk - it is normal
for the milk to separate.
• Do not shake breast milk.
• If warming, swirl and test breast milk temperature by
dropping some onto your wrist to make sure it is not too
warm for your baby.
• Thaw frozen milk in the refrigerator overnight or by running
under warm water. You may also thaw milk in a container of
warm water.
• Never microwave breast milk. Microwaving creates hotspots
which can burn your baby’s mouth.
• Use thawed breast milk within 24hrs.
• Adjust the suction level according to what’s comfortable
for you, using the + or - buttons. The best way to nd your
preferred level is by increasing the suction until you feel
discomfort, then decrease the level by one until you’re
comfortable. You should not feel any discomfort while using
the Premium Care double electric breast pump.
• When using the Power Pump mode the pump will cycle
through the stimulation mode 5x before switching to
expression mode for 5x. The stimulation level is set at
75mmHg and the expression level can be adjusted between
level 1-9. This mode helps to trigger more letdowns and offers
maximum stimulation for increasing milk supply.

13
Safe use of
YOUR PUMP
• Power adaptor is part of the breast pump. Do not use other
adaptors.
• Always unplug the electrical pump unit immediately after
use or charge has completed.
• Do not use it while bathing.
• Do not place or store device where it can come in contact
with water.
• Do not reach for your device if it has fallen into water,
immediately unplug from the electrical outlet.
• Do not leave the device unattended when plugged into an
electrical outlet.
• Do not position the breast pump such that it is difcult to
disconnect the adaptor plug from the main power supply.
• Close supervision is necessary when using near children or
people with disabilities.
• Use product only for it’s intended use. Do not use
attachments not recommended by the manufacturer.
• Keep all cords away from heated surfaces.
• Never use while sleepy or drowsy.
• Never drop or insert objects into any openings or tubes.
• Always inspect power adaptor and batteries prior to use for
damaged or exposed wires. If damage is found immediately
discontinue use of power adaptor.
• Do not operate while driving a vehicle.
• Bottles and component parts can become brittle when
frozen and may break if dropped.
• Take appropriate care when handling bottles and
components.
• Do not use breast milk if bottles or components become
damaged.
• Clean the valve area with care. Wire bottle brush ends can
damage the silicone.
GENERAL WARNINGS
PRECAUTIONS

14
• This device is a closed system breast pump. Milk collection kit
must not be shared between users.
• Use only under medical recommendation while pregnant.
• Clean and sanitise all parts that come in contact with your
breasts and breast milk prior to rst use. Wash all parts that
come in contact with your breasts and breast milk after
every use.
• Inspect all appropriate pump components before each use.
• Do not thaw frozen breast milk in a microwave or a pan of
boiling water.
• If tubing becomes mouldy, discontinue use and replace
tubing.
• If breast milk back up occurs, clean the tubes before your
next pumping session.
• Do not wrap cord around adaptor body
• Use only the power adaptor that comes with the Milkbar
Premium Care double electric breast pump.
• Do not shorten tubing.
• Make sure the voltage of the power adaptor is compatible
with the power source.
• Plug the power adaptor into the breast pump rst, then into
the power source.
• Do not attempt to remove the breast shield from your
breasts while pumping. Turn the breast pump off and break
the seal between your breast and the breast shield with your
nger, then remove the breast shield from your breast.
• If pumping is uncomfortable or causing pain, reduce the
suction, or discontinue pumping, turn the unit off, and check
the size guide for correct shield. If pain still persists consult a
breastfeeding specialist.
WARNINGS TO
AVOID HEALTH RISK
AND REDUCE THE
RISK OF INJURY

15
Troubleshooting
YOUR PUMP
IF YOU EXPERIENCE PAIN OR DISCOMFORT FROM PUMPING, STOP IMMEDIATELY AND CONSULT
A BREASTFEEDING SPECIALIST OR LACTATION CONSULTANT. IMPROPER USE OF BREAST PUMP
MAY RESULT IN BREAST TISSUE DAMAGE OR MASTITIS.
• You might be experiencing breast engorgement.
• Try placing a warm towel on the breast or warm shower.
ISSUE CAUSE SOLUTION
Low suction 1. Air leak at connecting parts
(valve, diaphragm, tube or tube
connectors)
2. Air circuit is blocked or tube is
bent or residue found inside the
tube
Check each connecting part,
pinch together the valve to
create a ush seal, re-install
the milk collection kit and clean
it, if necessary. Replace any
damaged parts.
No suction 1. Valve is torn or damaged
2. Diaphragm is not in place
3. Tubing not connected in cap.
1. Replace insert/valve
2. Place the diaphragm in place
and replace if any noticeable
damage.
3. Firmly connect tubing into
connectors and then into the
cap.
Unable to start The plug is not connected with
the main socket or the lithium
battery is drained / defected
Re-plug the adapter or fully
charge the battery and try again
Milk backow or
water found in
tube
Diaphragm is not placed in
correct position or is damaged
Stop using the device and take
out the diaphragm for checking /
replacement
Display screen
shows E1 or E2
alarm
E1: Stands for open circuit
E2: Stands for short circuit
Please contact our friendly team.
Display screen
shows E3 alarm
The internal temperature of the
pump unit exceeds the normal
operating temperature range
(less than Celsius degree 0°or
higher than Celsius degree 60°)
Turn off the pump unit and place
it in a circumstance where its
temperature is within the normal
working range until the pump
unit cools down or warms up.
BREAST PUMP IS
WORKING BUT NOT ABLE
TO EXPRESS MILK:

16
• The power button must be long pressed to power on.
• Check your power outlet by plugging in another electrical
device.
• Make sure the power outlet source is working and is the
Milkbar adapter.
• Make sure that your power adapter is connected properly
with the breast pump unit.
• If you are using a power adapter and your breast pump is
still not turning on, try using the battery power instead of the
plug
• Make sure the battery is fully charged. If it works on the
battery power, you might have a defective adapter.
Milkbar is a closed system breast pump, designed with a
barrier so that the milk will not backflow into the tube.
Below are some measures to avoid the potential milk backflow:
• Adjust the suction to a lower level if your breast milk is
relatively abundant.
• Try releasing pressure between your breast and the ange if
you notice that the milk is gathering inside the tunnel and is
not streaming down to the milk collection bottle
• Do not overll the milk collection bottle
• Rinse and clean the valves after each use.
• The Lithium battery is built-in and non-removable.
• Do not try to disassemble it
• Do not expose pump unit under direct sunlight or any other
kind of heat source
• Recharge the pump unit once a month when it is not
frequently used
• Repair of the device must be conducted by authorized
service agents.
DEVICE NOT POWERING
ON
MILK OVERFLOW
PREVENTION
PUMP UNIT / LITHIUM
BATTERY PRECAUTIONS:
• Use alternating hand expression and gentle breast massage
to help decrease swelling and improve the breast drainage.
Try doing this before starting a pumping session.
• Do not pump more than 30 minutes to avoid hurting your
breast. If you have engorged breasts, hold and massage
gently while pumping milk to help with the milk ow.

17
Important
SAFETY INFORMATION
• Failure to follow these instructions/safety information will
lead to potential risk / danger
• This is a single user product. Usage by more than one person
may post potential health risk to the consumer
• Use your Milkbar Premium Care breast pump only for its
intended use as described in this instruction manual. Do not
use the device while sleeping or overly drowsy. Supervision is
required when Milkbar Premium Care breast pump is used in
the vicinity of children.
• Unplug the adapter from socket outlet when the pump is not
in use.
• Do not leave your breast pump needlessly plugged into the
power source. Keep the device dry and do not immerse into
water. Do not reach for an electrical device if it has fallen into
water. Unplug immediately
• This breast pump is protected against overheating: when
normal operating temperature is higher or lower than
the internal temperature of the pump unit, it will alarm E3
for attention. Please shut down the device and unplug it
immediately until it regains temp or cools down.
• Do not operate the Milkbar breast pump near any kind of
appliances that generates strong magnetic eld.
• Medical equipment and other devices should be disposed
of and proper containers that meet Environmental
Protection Agency standards. Check with your local laws and
regulations in regards to proper disposal.
• Milkbar Maternity & Breastfeeding reserves the right to
change product design.
GENERAL
DISPOSAL

18
TECHNICAL PARAMETERS
• Power Adapter
• Power Input: 100-240V ~ 50/60Hz
• Power Output: 5V, 2A
• Power Rating: 10W
• Li-ion polymer battery power: 3.7V ~
3600mAh
• Stimulation Speed: 0/90/100 T/min (+/- 5T/
min)
• Expression Speed: 20~60 T/min (+/-5T/
min)
• Stimulation Suction: -0.006~-0.015Mpa
(+/-0.003Mpa)
• Expression Suction: - 0.016~-0.033Mpa
(+/-0.003Mpa)
• Speed of Power Pump Phase: 20~60 T/
min (+/-5T/min)
• Suction of Power Pump Phase: - 0.016~-
0.033Mpa (+/-0.003Mpa)
• Speed of Auto Loop Phase: 20~60 T/min
(+/-5T/min)
• Suction of Auto Loop Phase: - 0.016~-
0.033Mpa (+/-0.003Mpa)
• Timer: 30 minutes
• Electronic Equipment Protection: TYPE II
Class
• Overall Noise: ≤55dB(A)
• Operating Conditions:
Temperature 41-104°F
Humidity RH ≤90%
Warranty
INFORMATION
The Milkbar Premium Care Double Electric Breast Pump is warranted to the original user
only and is non-transferable. Milkbar warrants all breast pump models from the original
date of product purchase, against all defects in material and workmanship:
• the pump motor is warranted for a period of one year, and;
• 90 days on all pump components, whether purchased from Milkbar Maternity &
Breastfeeding directly or it’s authorised stockists.
Milkbar Maternity & Breastfeeding at it’s discretion and to the extent permitted by law, shall
repair or replace any product that is determined defective provided it is covered within this
limited warranty. Except to the extent prohibited by applicable law or, all implied warranties
(including warranties of merchantability and tness for a particular purpose) shall be
limited to the duration of this limited warranty.
Proof of purchase, which can be in the form of a receipt, invoice or bill of sale to evidence
limited warranty coverage must be provided. Milkbar Maternity & Breastfeeding shall
not be liable for any incidental, consequential, special by way of misuse, neglect of
maintenance, not following instructions in the user manual, using improper accessories,
or punitive damages resulting from any breach of limited warranty or implied warranty, or
under any other legal theory. Some jurisdictions do not allow the exclusion or limitation of
special, indirect or consequential damages so the above limitation may not apply to you.
No other warranties that accompany this product. any oral, written or any other
representation of any kind is hereby disclaimed.


Table of contents