MZ INSTALLATION & MAINTENANCE
The purpose of this manual is to provide a useful reference for
contractors, distributors, engineers, architects, building
owners, and those considering the use of this heating system.
1. There is no low temperature return limit. This means that
NO SYSTEM / THERMAL SHOCK PROTECTION IS
REQUIRED. The MZ is a fully condensing heating system.
The colder the return water, the more condensing action,
the more efficient.
2. The heat exchanger is stainless steel.
• You will not shock, warp, corrode, or otherwise harm it
with temperature or rapid temperature changes.
• No primary/secondary piping arrangements are needed
to protect the heating system from low-temp. operation.
• You can size the heating system to the heat loss of
the structure. This is important when the structure has
been improved over the years but the original radiation
remains, permitting lower operating temps at high
efficiency and comfort levels.
3. An adjustable control knob on the unit, from 65º to 176º F,
controls the outgoing water temperature limit for the main
I. INTRODUCTION - IMPORTANT INFORMATION
I. Introduction .................................. 2
MZ 25C
Important Information ...................... 2
The Monitor MZ .............................. 3
Technical Specifications ................. 4
Getting Started ............................... 5
Receiving, Opening, Storage ........... 5
II. Installation & Technical ............... 5
Location .......................................... 5
Mounting ......................................... 6
Using MZS to Produce DHW .......... 6
Condensate .................................... 7
Charging & Leak Testing ................. 7
Corrosion ........................................ 8
Freeze Protection ........................... 8
Gas Piping ..................................... 8
Propane Conversion ........................ 8
Venting ......................................... 10
Electrical . .................................... 15
Start Up ........................................ 16
Flow Verification ........................... 16
III. Accessories ................................. 17
BS Indirect Water Tank................. 17
Domestic Hot Water Kit ............... 18
MZ Mod Control ............................ 18
IV. Maintenance................................ 19
V. Troubleshooting ......................... 19
VI. Appendix A ................................. 22
Piping schematics ........................ 22
Wiring schematics........................ 26
VII. Appendix B ................................. 29
Parts and Assembly drawings ...... 29
VIII.Warranty ..................................... 40
! FOR YOUR SAFETY !
This product must be installed and serviced by a professional service
technician, qualified in hydronic heating system installation and
maintenance. Improper installation and/or operation could create carbon
monoxide gas in flue gases which could cause serious injury, property
damage, or death.
Improper installation and/or operation will void the warranty.
! WARNING !
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
loss of life. Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
! WHAT TO DO IF YOU SMELL GAS !
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a nearby phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Products that have earned the Energy Star®are
designed to protect the environment through
superior energy efficiency.
ISO 9001 registered. Approved by AGA, CGA,
CSA, IAS, CE and several state and municipal
approvals.
TABLE OF CONTENTS - INTRODUCTION
heat. No other controls or mixing valves are needed for low
temp applications. The MZ’s design simplifies multi-temp,
multi-zone applications.
4. When using the MZ for domestic hot water (DHW) or other
priority application, use our MZ DHW kit, part # 9523. It
makes combining different temps for heat and DHW or
other applications quick and easy. Our 25, 40, 50 and 80
gallon BS tanks are perfectly matched to MZs.
5. MZ heating systems are completely self-contained.
Circulator pump, air eliminator, low water cut off, pressure
relief valve, condensate trap and drain, return water strainer,
temperature/pressure gauge, fill/ drain valve, on/off &
summer/winter switch, manual flow bypass, and, except
for the MZ40C, an expansion tank big enough for a 25
gallon system.
6. Three vent systems available:
1.) Parallel CPVC - separated exhaust & inlet air
2.) Horizontal concentric
3.) Vertical concentric
For most new and retro-residential jobs, there are no other