Nady Systems PCL-800 User manual

RACK LIGHTS
POWER CONDITIONER & LIGHT MODULE
1800 WATTS CA PACITY
PULL
PULL
MIN MAX
OVER
VOLTAGE
STANDARD
VOLTAGE
DIMMER REAR OUTLETS
ON
OFF
CHO3080
CHO3081

Congratulations!
PCL
Series
Power
Conditioners
For advanced RF/EMI noise filtering and the quietest
operation of your equipment...
Triple mode varistor surge and spike protection
Eight rear outlets (with room for 4 ¡°wall wa rts¡±)
controlled by afront panel switch
15 amprating (1800 W) with rear panel circuit
breaker (UL)
Two added front panel slide-out, swiveling lights for
rack illumination and dimmer controls to adjust
lamp brightness (PLC-810 and PLC-815 only)
Large LED numeric meter that displays incoming
AC line voltage and 2 voltage condition indicators-
standard voltage and over voltage (PLC-815 only)
Rugged single rack space metal housing for maxi-
mum reliability
Date of Purchase
Dealer¡¯sName
City
State
Zip
Model #
Serial #
You have purchased one of the finest professional power
conditioners on the market today. This unit was devel-
oped using the expertise of professional sound engineers
and working musicians. You will find your new unit has
superior performance and greater flexibility than any
other power conditioner in its price range.
Read this manual carefully to get the most out of your
new unit..
2
PCL-800 Power conditioner
PCL-815 Power conditioner with lights and
AC meter display
Features
Features ...........................................
Warning..........................................
Controls,
functions,
connections..........
Installation and operation...................
Specifications......................................
CONTENTS
2
3
4
6
7

3

Controls, functions, and connections
FRONT PANEL
1. POWER SWITCH
Outlet switch (with built-in LED ONindicator) activates protection and filtration to all back panel outlets. To tu r n
the unit ON or OFF, press the upper or lower portion of this button.
2. 2 RETRACTABLE RACKLIGHTS
Pull out for illumination and swivel to desired angle
3. LIGHT SWITCH
Activates rack illumination
4. DIMMER CONTROL
Use to control the intensity of the illumination. Turning clockwise increases the light output.
5. DIGI TAL VOLTMETER READOUT
Displays incoming AC li ne voltage
6. VO LTAGE LED METER
Separate green and red LEDs monitor the incoming voltage range. The green LED indicates voltage is in the
normal operating range. The red LED lights when the voltage exceeds 125V, indicating that the supplied power
is out of range for normal operation.
4
RACK LIGHTS
POWER CONDITIONER & LIGHT MODULE
1800 WATTS CA PACITY
PULL
MIN MAX
OVER
VOLTAGE
STANDARD
VOLTAGE
DIMMER REAR OUTLETS
ON
OFF
2
4
31
56
26

REAR PANEL
7. POWER CORD
Heavy duty 14-gauge power cord for connection to the AC power mains (120V-60Hz)
8. CIRCUIT BREAKER
Resettable 15 amp ther mal circuit breaker
9. 8 REAR PANEL OUTLETS
EMI/RFI filtered, spike/surge protected and switched
5
789

6
1. The
PCL
Series
conditioners
are
the
perfect accessories for any rack mount system. Install in the top slot of a
standard
19-inch
rack,
and
the
8
switched
AC outlets on the rear panel will provide full safety protection to all
your
rack
equipment.
These
conditioners
protect your delicate electronic equipment by combining
a high
voltage
varistor
surge
and
transient
suppressor
with an RFI/EMI interference filter. The filter helps prevent noise
from
fluorescent
lights,
motors,
and
similar
sources of “electronic pollution” from contaminating the
AC feed to
your
senitive
video,
audio,
vtr
or
computer
circuits.
2. Plug Power
Cord
(7)into
a
standard
grounded
120V outlet
3. Plug
sensitive
electronic
equipment
into
the 8
Rear Panel Outlets (9)
4.
Turn Outlet
Power
Switch
(1)to
“ON”
position.
Lit LED indicates conditioned power to the connected
equipment.
5.
For
discreet
illumination
of
your
rack
equipment
on stage, in studios, and in other dark locations
(PCL-815
only),
pull
the 2
Retractable
Rack
Lights
(2) out
and
adjust
the Dimmer
Control
(4) for
the
lamp
brightness
desired
(see
fig.1
below).
The
lights swivel and can be adjusted to the proper angle for your appli-
cation. The
lamps
are
supplied
with
standard 5W night-light bulbs. If you find the heat from the bulbs exces-
sive,
reduce
the
setting
of
the Dimmer
Controlor substitute lesser wattage bulbs.
You can easily replace the
bulbs
without
removing
the
unit
from
the
rack by unscrewing the cap on the end of each light tube. (Note:
Be
careful
not
to
push
the
tubes
in
while the
caps
are unscrewed.)
6.
TheDigital
Voltmeter
Readout
(5)(PCL-815
only)
is calibrated to
a nominal 117
VAC at the factory.
No
adjustments
are
necessary.
7.
TheDigital
Voltmeter
Readout
(5)automatically displays incoming voltage when the Power
Cord
(7)
is
connected.
8.
MAXIMUM LOAD: The PCL Series Power Conditioners 8 Rear Panel Outlets are rated at 15 amps total load
(or 1800W at 120VAC). If this maximum load is exceeded, the Circuit Breaker (8) will trip, cutting
off power
to
all
connected
equipment
in
your
rack.
If this happens, reduce the load by unplugging one or more units
from
the
power
conditioner,
and
push
the
circuit breaker to reset it (see fig.2 below).
Installation
and
operation
fig.2
fig.1

Specifications
PROTECTION PROVIDED High voltage varistor surge and transient suppressor,
RFI/EMI interference filtration
OUTLET CONNECTORS 8 standard 3-prong grounded AC receptacles
POWER CONSUMPTION Maximum 1800W/15A load
POWER SOURCE ~120VAC/60 Hz
CIRCUIT BREAKER 15A thermal type
LAMPS (PCL-815) 5W (two)
DIMENSIONS 19” X 1.75” X 7.3”
(483 X 44 X 185mm), 1U rack height
WEIGHT PCL-800 4.45 lbs (2.0 Kg)
PCL-815 4.55 lbs (2.07 Kg)
For improvement purposes, specifications, design and appearance subject to change without prior notice