National Instruments NI Vision CVS-1450 Series User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

QUICK
START
GUIDE
Nl
CVS-1450
Series
Compact
Vision
System
Vision
Builder
for
Automated
Inspection
0
Connect
the
Hardware
Caution
Before
installing
Nl
CVS
-
1450
Series
hardware, refer
to
the
safety
information
in
the
Nl
CVS-1450
Series
User
Manual.
Connect
the
Camera
and
Monitor
to
the
Nl
CVS-1450
Device
A.
Connect
the
VGA
cable
from
the
monitor
to
the
VGA
port
on
the
Nl
CVS-1450
device.
B.
Plug
the
IEEE
1394
cable
into
one
of
the
IEEE
1394
ports
on
the
Nl
CVS-1450
device.
Plug
the
other
end
of
the
cable
into
the
IEEE
1394
port
of
the
camera.
C.
Plug
in
and
power
on
the
monitor.
Wire Power
to
the
Nl
CVS-1450
Device
This
section
explains
how
to
connect
the
power
supply
(part
number
778794-01)
to
the
Nl
CVS-1450
device
.
For
instructions
on
how
to
connect a
separate
main
supply,
refer
to
the
Nl
CVS-1450
Series
User
Manual.
Caution
Do
not
connect
the
Nl
CVS-1450
device
to
a power
source
other
than
24
VDC
+
10%.
Refer
to
the
Nl
CVS-1450
Series
User
Manualfor information
about
power
requirements.
To
Outlet
~
D.
Plug
the
4-position connector
from
the
power
supply
into
the
power receptacle
on
the
Nl
CVS-1450
device.
E.
Plug
the
power
cord
into
the
power
supply
.
F.
Plug
the
power
cord
into
an
outlet.
Once
connected,
the
Nl
CVS-1450
device
runs
a startup
program
that acquires
images
and
displays
them
on
the
monitor.
These
images
verify that
the
hardware
is
properly
connected
.
Connect
the
Nl
CVS-1450
Device
to
the
Development
Computer
Verify
that
the
development
computer
is
connected
to
the
network
and
powered
on.
G.
Using
a
standard
CAT
5
Ethernet
cable
(part
number
189174).
connect
from
the
network
port
to
the
Ethernet
port
on
the
Nl
CVS-1450
device.
H.
Using
a
standard
CAT
5
Ethernet
cable,
connect
from
the
network
port
to
the
Ethernet
port
on
the
development
computer
.
'I!J
Note
If
you
are
not
connecting
through
a network,
use
acrossover
cable
(part
number
187375)
to
connect
the
Nl
CVS-1450
device
to
the
development
computer
.
Install
the
Software
'I!J
Note
You
must
install
Vision
Builder for
Automated
Inspection
(Vision
Builder
AI)
before
installing
the
NI-IMAQ for
IEEE
1394
Cameras
driver software.
Install Vision Builder
AI
and
NI-IMAO for
IEEE
1394
Cameras
A. Insert
the
Vision
Builder
AI
CD
.
When
the
installation
splash
screen
appears,
click
Install Vision Builder for
Automated
Inspection
and
follow
the
setup
instructions.
Install Vision Builderfor Automated Inspection
2.6.1
Read
me
first
Explore the
CD
Exit
v·sion
Builder
forA
utoma
t
ed
Ins
pection
Install NI-IMAO for
IEEE
1394
Cameras
W.
NATIONAl
,-
INSTRUMENTS"
B.
When
prompted
, insert
the
Nl
Vision
Acquisition Software
CD
.
In
s
ert
Source ·
ij
.
NI
Vi
s
ion
Acquis
ition
Software
If
the
required
file
s
may
be
found
elsewhere
,
plea
se
enter
that
location
below
.
IL
ID
~
~
----------------~1
[]
The
s
pecified
folder
doe
s
not
contain
the
correct
volume
.
[ Res
can
Drive
] [
Cancel
]
C.
In
the
Features
tree, select NI-IMAQ for
IEEE
1394
Cameras
and
NI-IMAQ for
IEEE
1394
Hardware
Support.
#J.
NI
Vi
sion 8.0 Acquisition
So
ftware kJ\.
Llj
ij'
Features
")";
NATIONAL
Sele
ct
th
e
fea
tur
es
to
i
ns
ta
ll.
INSTRUMENTS"
1±1
~
NH
M
AQ
3.
5
.1
Dr
i
ver
softwa
refor
IE
EE
139
4
(F
ire
Wi
re]
II
DC
8
Ji!i!<!!i~
Q
fc
i!
IEEE
1394
:am
iias•
com
pl
ia
nt
c
ame
r
as.
i
nclu
ding camer
as
con
fi
g
ure
d
on
1'
-·
Nl
CVS-
14
50
Se
ri
es
co
mpa
ct
v
is
ion
sys
t
ems.
1±1
L
abVIEW
Suppo
rt
1±1
Lab
Wind
o
ws/CV
I Supp
ort
1±1
Mi
cr
oso
ft
Vis
ual CSupp
ort
IJ
9
~
1±1
·
Mi
cr
osoft
Visua
lB
asic
S
uppor
t
Mi
cr
osoft
.NET
L
an
guageSupp
ort
8
~
NI-I
M
AQ
for
IEEE
139
4
Hardwa
re
Su
p
port
Th
is
fea
ture
w
ill
bei
nst
all
ed
on
the
l
oca
l
ha
rd
dr
ive.
~
Nl 82
54R
Doc
u
me
ntation
Nl
CVS
-1450
Se
ri
es
Supp
ort
1±1
NI
·IM
AQ
1
10
1
.1
~
Nl
M
eas
ur
ement
&Autom
a
tio
n
Ex
p
lorer
4
.0
Th
is
fea
turea
nd
itssel
ec
te
d subco
mpone
nts
wi
ll
requi
re
1
80
KBof
di
sk
spac
e.
I<I
""
[I)
Di
rectory
for
NI-I
M
AQ
forI
EEE
1
39
4C
ame
ras
2.
0
.2
]
C:\P
r
og
r
am
Files\Nat
ion
allnstruments\NI
·IM
AQ
f
or
IEEE
-
139
4\
I[
Browse
...
]
I
Res
to
re
D
ef
aul
ts
II
Dis
k
Cost..
II
«B
ack
II
Nex
t»
I I Ca
ncel
]
D.
Click
Next.
E.
Follow
the
installer
prompts
to
complete
the
installation.
Artisan Technology
Group-
Quality Instrumentation
...
Guaranteed 1 (888) 88-SOURCE 1 www.artisantg.com

e
Configure
the
Nl
CVS-1450
Device
Obtain
an
IP
Address
A.
Launch
Vision
Builder
AI.
B.
Expand
the
Execution
Target
pull-down listbox
and
click Select Network
Target.
C.
In
the
Select
Remote
Target
window,
click
192.168.10
.
12
to
highlight
the
row.
This
IP
address
is
assigned
to
all
unconfigured
Nl
CVS-1450
devices.
Vi
sion
Bui
ld
er
for
Au
tomate
dI
nspection
1'1'
Se
l
ec
t Remote
Tar
get
Ta
rget
Name J IP
Add
ress J Description
192.168.10. 12
Monitoring 10.0.58.158 Line2
Sort
in
g 10.0.58.168
Line
1
I<T.
ocUli
-----:1
J Status
Run
nf'lg
Running
Running
W
NATJONAL
,-
INSTR
U
MENTS"
Configure I
ns
pection
I
ns
pect P
ro
duct
Help
Exit
-
&I
"
~
---
[ Configure ]
[ Properties )
[
Add
T
ar
get )
---
GO
8
~
IIl
~
Tip
To
uniquely
identify unconfigured
Nl
CVS-1450
devices,
connect
and
configure
one
Nl
CVS
-
1450
device
at
a
time
.
D.
Click
Configure
to
launch
the
Remote
Target
Configuration
Wizard
.
E.
In
the
Identification
window, enter a
name
F.
G.
H.
for
the
Nl
CVS-1450
device
in
the
Name
field
and
a
description
of
the
Nl
CVS-1450
device
in
the
Description field.
Note
Device
names
are
limited
to
15
characters with
no
spaces
or
special
characters.
The
first
and
last letters
must
be
alphanumeric.
Click
Next.
If
the
network
is
configured
to
issue
IP
addresses
using
DHCP,
select
Obtain
IP
Address
from
DHCP
Server.
Otherwise,
set
the
IP
address
manually
by
selecting
Edit
IP
Settings,
Suggest
Values,
and
OK
.
Click
Next.
~
Remote
Tar
ge
t Confi_guration
Wi
z
ard
Step
1
of
3:
Identification
M
od
el
:
NI
1450 Series
Serial Number:
FFFFFFFF
MAC
Address:
00:80:
2F
:
D9
:2D
:B
8
System Status: Running
Name: j
PartV
a
li
da
ti
on
Description: r
e3
Jl Remote Targ
et
Configuration Wizard
Step
2
of
3:
Network
Settings
0 Obtain IP Addr
ess
from
DHCP
Ser
ver
0 Edit IP Settings
ISuggest Values .. I[Reset to Default I
IPAddress 1 192
.168
. 10 . 12
Su
bnet
Mask I255 . 255 . 255 . 0
Gateway I
o.
o.
o . 0
DNS
Server I
0. 0.
0 . 0
D
Ena
b
le
Pa
ss
word
I Set Password I
:I
Download Software
to
the
Nl
CVS-1450
Device
I.
Select
the
Update
Target
Software
checkbox
.
J.
Click
OK
to
begin
configuring
the
IP
address
and
downloading software
onto
the
Nl
CVS-1450
device
.
This
initial
installation
process
takes
several
minutes
.
Software Host
.;
DataSocket for
LabV
IEW Real-T 4. 3
./
LabV
IEW
Re
al
-
Ti
me
7,
1,
1
./
NI-IMAQ
fo
r IE
EE
1394 RT 2.0.2
./
NHMA
Q I
/0
1.1.0
./
NI-IMAQ Server 1.6. 1
.;
NI
·R
IO
RT
2.0.0
Target
"'
4.
3
7.1.1
2.0.2
1.1.0
3
1.
6
.1
2.0.0
./
NI
-S
erial RT 2.5.6 2.5.6
.;
NI-1394 E
xt
ernal
Dr
ive Support
1.
3.3.3.
1.
3.3.3
./
NI
-V
ISA 3.4. 1 3.4. 1
./
NI-
VI
SA Server 3. 4.1 3.4.1 8
Software Status:
Compl
e
te
~
Update Target So
ftware
0
Acquire
an
Image
A.
Launch
Vision
Builder
AI.
B.
Expand
the
Execution
Target
pull-down listbox,
and
click Select Network
Target.
Vi
sion
Bu
il
der
for
A
utomate
dI
nspection
W
NATJONAL
,-
INSTR
U
MENn
'
Co
nfigure In
sp
ection
In
sp
ect Product
Help
Exit
C.
Select
the
Nl
CVS
-
1450
1"
Se
lect Remote Ttu g
et
device
you
configured, T
ani)et
N
ame
l
iP
Address I
Desc
r
iption
P
llr
t
V.!IIidation
19
2
.1
68
.1
0. 12 line3
~
~~~
~~~
~~~
~
~~
~~~~~.
~St·~
t
"~'
~~=-~
A
~
R
L«i
ng
D.
and
click
OK
.
On
the
Vision
Builder
AI
Welcome
screen,
click
Configure
Inspection.
fiiSl
~c
q u
ir
e
Im
age
(IEEE
1394
):
Ac
quir
es
an
l•
~
r
mage
fromthe selected IE
EE
1
39
4
ca
mera.
~
Si
mu
late Acquisition:
Si
mulat
es
the
acquisiti
on
of i
mages
by reading
images
from f
ile.
~
Se
l
ec
t Image:
Selects
a new i
mage
to J
~i
nspe
c
t.
Mooitor
in
g
Sorting
~
E.
From
the
Acquire
Images
palette,
click Acquire
Image
(IEEE
1394).
10.0.58.158
10.0.58.168
line2
linel
Ruming
Ruming
I
Configure
)
[
Properties
I
I
Add
Target
I
M
ai
n IFeatu
re
s [ T
rig
ge
r [
For
mat 7 Features L
St
ep N
am
e
)A
cq
uire
Im
age
(I
EEE
1394) 1
De
vi
ce
s
I
~
Basl
er A60if (#00305300013
8D9
.-,
l
V
id
eo
Mode
JS40x4
80
Y
(M
o
no
16) 30.00fps
F.
Click
the
Snap
~
button
to
acquire a
single
image,
or
click
the
Grab
G
button
to
acquire continuous
images.
Once
you
have
configured
your
acquisition, click
OK
to
add
the
step.
You
can
now
add
inspection
steps
as
described
in
the
Nl
Vision
Builder
for
Automated
Inspection
:
Configuration
Help
.
QUICK
START
GUIDE
Nl
CVS-1450
Series
Compact
Vision
System
This
document
describes
how
to
set
up
and
acquire
an
image
using
the
Nl
CVS-1450
Series
compact
vision
system
with
Nl
Vision
Builder for
Automated
Inspection
or
the
Lab
VIEW
Real-Time
Module
and
the
Nl
Vision
Development
Module.
Use
these
instructions
to
verify that hardware
and
software
are
properly installed,
to
configure
an
IP
address
for
the
CVS-1450
device,
and
to
acquire
an
image
.
3736098·01
Note
These
instructions
are
intended
for
basic
installation
and
configuration.
Refer
to
the
Nl
CVS
-
1450
Series
User
Manual
and
the
application software
documentation for detailed installation
and
configuration instructions.
Refer
to
the
blue
side
of
this
document
if
you
are
using
Vision Builder for
Automated
Inspection
Refer
to
the
yellow
side
of
this
document
if
you
are
using
the
labVIEW
Real-Time
Module with
the
Nl Vision
Development
Module
Ma
r06
Nation
al
In
s
trum
e
nt
s,
Nl
,
ni
.c
om
,
and
Lab
VIEW
ar
etrade
mark
s
of
Nation
al
In
s
trum
e
nt
s Corporation.
RefertD
the
Te
rm
s ofU
se
sec
tiDn
on
ni
.
com/legal
fDr
mor
e infD
rm
a
ti
Dn a
bout
National
In
s
trum
e
nt
stradema
rk
s.
Oth
er product a
nd
comp
any nam
es
me
ntion
ed here
in
aretradema
rk
s
Dr
trade nam
es
of
th
eir r
es
p
ec
ti
ve
co
mpani
e
s.
For
pat
e
nt
s co
ve
ring
National
In
s
trum
e
nt
s
produ
ct
s,
refer to
th
e appropriate
lo
c
ati
on: Help»Patents
in
yo
ur
softw
ar
e,
th
e
patents
.
txt
file
on
yo
ur
CD
,
or
ni.
com/patents
.
©
2003
-
2006
National
In
s
trum
e
nt
s
CDrpDr
at
ion
.
All
rights
re
se
rv
ed
.
~
NATIONAL
,.
INSTRUMENTS
'M
Artisan Technology
Group-
Quality Instrumentation
...
Guaranteed 1 (888) 88-SOURCE 1 www.artisantg.com

QUICK
START
GUIDE
Nl
CVS-1450
Series
Compact
Vision
System
Lab
VIEW
Real-
Time
Module with
the
Nl
Vision
Development
Module
0 Connect the Hardware
&
Caution
Before
installing
Nl
CVS-1450
Series
hardware, refer
to
the
safety
information
in
the
Nl
CVS-1450
Series
User
Manual.
Connect
the
Camera
and
Monitor
to
the
Nl
CVS-1450
Device
A.
Connect
the
VGA
Cable
from
the
monitor
to
the
VGA
port
on
the
Nl
CVS-1450
device.
B.
Plug
the
IEEE
1394
cable
into
one
of
the
IEEE
1394
ports
on
the
Nl
CVS-1450
device.
Plug
the
other
end
of
the
cable
into
the
IEEE
1394
port
of
the
camera.
c.
Plug
in
and
power
on
the
monitor.
Wire Power
to
the
Nl
CVS-1450
Device
This
section
explains
how
to
connect
the
power
supply
(part
number
778794-01)
to
the
Nl
CVS-1450
device.
For
instructions
on
how
to
connect a
separate
main
supply,
refer
to
the
Nl
CVS-1450
Series
User
Manual.
Caution
Do
not
connect
the
Nl
CVS-1450
device
to
a power
source
other
than
24
VDC
+
10%
.
Refer
to
the
Nl
CVS-1450
Series
User
Manual for information
about
power
requirements.
To
Outlet •
D.
Plug
the
4-position connector
from
the
power
supply
into
the
power receptacle
on
the
Nl
CVS-1450
device.
E.
Plug
the
power
cord
into
the
power
supply
.
F.
Plug
the
power
cord
into
an
outlet.
Once
connected,
the
Nl
CVS-1450
device
runs
a startup
program
that acquires
images
and
displays
them
on
the
monitor.
These
images
verify that
the
hardware
is
properly
connected
.
Connect
the
Nl
CVS-1450
Device
to
the
Development
Computer
Verify
that
the
development
computer
is
connected
to
the
network
and
powered
on.
G.
Using
a
standard
CAT
5
Ethernet
cable
(part
number
189174),
connect
from
the
network
port
to
the
Ethernet
port
on
the
Nl
CVS-1450
device.
H.
Using
a
standard
CAT
5
Ethernet
cable,
connect
from
the
network
port
to
the
Ethernet
port
on
the
development
computer.
'fS
Note
If
you
are
not
connecting
through
a network,
use
acrossover
cable
(part
number
187375)
to
connect
the
Nl
CVS-1450
device
to
the
development
computer.
0 Install the Software
lS
Note
You
must
install
LabVIEW,
the
LabVIEW
Real-Time
Module,
and
the
Nl
Vision
Development
Module
software
before
installing
the
NI-IMAQ for
IEEE
1394
Cameras
driver software.
Install
LabVIEW
and
the
LabVIEW
Real-Time
Module
A. Insert
the
LabVIEW
CD
.
When
the
installation
screen
appears,
click Install
LabVIEW
and
follow
the
setup
instructions.
B.
Welcome
to
LabVIEW 8.0
~
Install
LabVIEW
8.0
~View
Readme
~
Explore
the
CD
~Exit
labVIEW~ B
®
al:1'5
N:Mi
on
ii
llnstruments.
,1111
ri
ghts reser'M:I.
Insert
the
LabVIEW
Real-Time
Module
CD
.
When
the
installation
screen
appears,
click Install
LabVIEW
Real-Time
Module
and
follow
the
setup
instructions.
Welcome
to
LabVIEW
8.0
Real-
Time
Module
~
Install
Lab
VIEW
8.0
Real
-
Time
Module
mJ
View
Readme
~
Explore
the
CD
~Exit
®2005
N:M
ional
In
struments.
,1111
rights re
s:erwd
.
.' .
Install
the
Nl Vision Development Module
and
NI-IMAQ for
IEEE
1394
Cameras
C.
Insert
the
Nl
Vision
Development
Module
CD.
When
the
installation
screen
appears,
click Install Nl Vision
Development
Module
and
follow
the
setup
instructions.
Install Nl Vision 8.0 Development Module
Read me first
Explore the
CD
Exit
Vision
Develop
ment
Modu
le
Software
W.
NATIONAL
,....
INSTRUMENTS'
D.
When
prompted,
insert
the
Nl
Vision
Acquisition Software
CD.
In
sert
So
ur
ce
Nl
Vis
ion
Acquisition
Software
It
the
required
file
s
may
be
found
el
se
where
.
plea
se
enter
that
lo
c
ation
below
.
J
o~
JD
~----------------------~
The
specified
folder
doe
s
not
contain
the
correct
volume
.
[ R
escan
Drive
J[
Cancel
]
E.
In
the
Features
tree, select NI-IMAQ for
IEEE
1394
Cameras
and
NI-IMAQ for
IEEE
1394
Hardware Support.
;fj.
Nl
Vi
sion 8.0 Acquisition Software
1..
-J
LLlJ
t;t
Fealu1es
')';
NATIONAL
Select
the
features
to
install.
INSTRUMENTS'
If)
~
NI·IMAQ
3.5
.1
Driver
software
for
IEEE
1
394
(FireWire)
II
DC
8·
j
~
Q
for
IEEE
13
94
Camera
s
2.0.2
compliant
cameras,
including
cameras
configured
on
1''-~~
Nl
CVS-1450
Ser
i
es
compact
vision
systems
l±.l
LabVIE
W
Suppo
rt
(±)
LabWindow
s/CV
I
Sup
p
ort
III
Microsoft
Visual
C
Support
11
9
~
I±)
Mic
r
osoft
Vi
s
ual
Ba
sic
Support
IIl
Micro
so
ft
.
NET
Language
Support
8
~
NI-IMAQ
for
IEEE
139
4
Hardware
Support
This
feature
will
be
installed
on
the
local
hard
drive.
~
Nl
8254R
Documentation
Nl
CVS-1450
Series
Support
1±1
NI·
I
MAQ
liD 1.1
~
Nl
Mea
surement t.Automation Explorer 4
.0
This
feature
and
its
selected
subcom
ponents
will
require
180
KB
of
disk
space.
I<I Ill! :-=Jill
Directory
for
NI-IMAQ
for
IE
EE
1394
Cameras
2.0
.2
·j
C:\P
rogra
mFiles\
Nati
onallnstruments\NI
-IMAQ
for
I
EEE-
1394\ J[
Browse
..
. ]
I Restore
Defaults
II
Disk
Cost...
II
«
Back
II
Next
» I
~
F.
Click
Next.
G.
Follow
the
installer
prompts
to
complete
the
installation.
Artisan Technology
Group-
Quality Instrumentation
...
Guaranteed 1 (888) 88-SOURCE I www.artisantg.com

0 Configure
the
Nl
CVS-1450
Device
Obtain
an
IP
Address
~
PartValidation - M
eas
ur
eme nt ft Automation Explore r
--
- - -
--
- -l-
..J
L
LI
J
&J
Fi
le
Ed
it
View
Tool
s
He
lp
Configurat
i
on
::::
rReboot
ti
Lock
I
[;)
Re
fr
esh
.Apply
I
<
~Show
Hel
p
El
~
My
System
1±1
£I
Dev
ices
an
d Inte
rf
aces
I±J
~
So
ft
wa
r
e
Ide
n
ti
fic
at
io
n
Mod
el:
IP
Se
t
tin
gs
NI
1450
Se
ri
es
El
~
Remote
Sys
t
ems
Se
ri
al
Nu
mb
er:
D
DDBBDED
r.
Qbtarn
IP
address
from
DHCP
erver
r
g_drt
the
JP
;.cettrngs
M
AC
Ad
dress·
DO80
:1
1:0
a:
57
:c1
1±1
ii3
!
192
1
68
.-
io
i~
Suggest
Values.
I
To
Default
Name
· I
System
St
ate:
Disconnecte
d !Pa
dd
ress:
19
2.1
6
8.10.1
2
b;omm
ent:
~
u
bnet
m
as:k:
255.255.255.
0
§a
te
way:
0.
0
.0.
0
QNS server
0.
0
.0.
0
r fassword·protect Resets
17
l:!alt
.>ystem
rf
TCP/IP
farls
Advanced Ethemet
Setting:;.
J
~
Ne
t
wo
rk Sett
ing
s
~
System
Se
tt
in
gs
[*C
onn
ected -
Ru
nn
in
g
A.
Launch
Measurement &
Automation
Explorer
(MAX)
and
expand
the
Remote
Systems
branch
of
the
configuration
tree
.
B.
Click
192.168.10
.
12
to
display
the
Network
Settings
window.
This
IP
address
is
assigned
to
all
unconfigured
Nl
CVS-1450
devices.
Tip
To
uniquely identify unconfigured
Nl
CVS-1450
devices,
connect
and
configure
one
Nl
CVS
-
1450
device
at
a
time.
C.
In
the
Network
Settings
window,
type
a
name
for
the
Nl
CVS-1450
device
in
the
Name
field
and
adescription
of
the
Nl
CVS-1450
device
in
the
Comment
field
Note
Device
names
are
limited
to
15
characters with
no
spaces
or
special characters.
The
first
and
last
letters
must
be
alphanumeric
devices.
D.
If
the
network
is
configured
to
issue
IP
addresses
using
DHCP,
select
Obtain
IP
address
from
DHCP
server.
Otherwise,
set
the
IP
address
manually
by
selecting
Edit
the
IP
settings,
Suggest
Values,
and
OK.
E.
Click
Apply.
When
prompted
, click
Yes
to
restart
the
Nl
CVS-1450
device
.
This
initial
installation
process
takes
several
minutes.
While
the
Nl
CVS-1450
device
is
restarting, a
red
Xl•x•l
appears
next
to
the
device
name
to
indicate that
the
Nl
CVS-1450
device
is
disconnected.
The
MAX
status
bar
also
indicates
the
connection
status
of
the
Nl
CVS-1450
device.
Download Software
to
the
Nl
CVS-1450
Device
F.
In
the
MAX
configuration tree,
expand
the
device
folder
by
clicking
the
plus
sign
next
to
the
device
name
.
G.
Click
the
Software
branch
.
H.
Click
the
Add/Remove
Software
button
.
I.
Select
the
software
to
install
on
the
Nl
CVS-1450
device
.
l a
bVIEW
Real-Time S
oftware
Wizard
Features
Select
the
features
to
install and installed components
to
uninstall.
'W
NATIONAL
,-
INSTRUMENTS'
·
~
if£1.
~~!§
.
6;il~
.
s.
Ir.~~~
~t.
~:
~r
.
~il
i
~i.
.
~
::
~:
:~
::
:
::
~
J
~
·:.
~
-X
DataSocket for LabVIEW
Real
-
Time
4.3
~
LabVIEW Real-
Time
8.0
:.
~
Modbus
1/
0 Server I.
0,
0
··
~
NI
Vision
RT
8.
0.0
; X NI-1394 External
Dri
ve Support 1.3.
3.
3.0
:
..
~
NI-IMAQ
1/
0 1.1.2
~
NI-IMAQ
Ser
ver I.6,I
NI-IMAQ for
IEEE
1394
RT
2.0.2
~ NI-RIO
RT
2.0.0
~
NI-Serial
RT
2.5.6
NI-VISA 3.
4.
I
!.. ~ NI-
VISA
Server 3.4. 1
.! Network Variable Engine 1,0,0
.
~
Variable Client Support 1.0.0
Update
05
...
J.
Click
Next.
<<Back
National Instruments Real-
Time
Software,
To
install or
uninstall software) click on the icon and select
the
appropriate
option from the drop down menu.
Ne
x
t>
> I I Cancel I I Help
The
Nl
CVS-1450
device
will automatically restart.
This
process
takes
several
seconds.
0 Acquire
an
Image
You
can
acquire
an
image
using
MAX
or
the
LabVIEW
Real-Time
Module
.
Acquire
an
Image
using
MAX
A.
Launch
MAX
.
B.
In
the
MAX
configuration tree,
expand
the
device
folder.
C.
Expand
Devices
and
Interfaces.
D.
Expand
NI-IMAQ
IEEE
1394
Devices
.
E. Select a
camera
.
F.
Click
the
Snap
button
to
acquire
a
single
image,
or
click
the
Grab
button
to
acquire
continuous
images
.
p;soil
Se.iiiiH\61lbe
r j
Cbdi0305300013009EO
Acquire
an
Image
using
the
labVIEW
Real-Time
Module
A.
Launch
Lab
VIEW,
and
select
to
create
a
new
Real-Time
Project.
B.
Select
Custom
project for
the
Project
type
, enter aProject
name,
select
the
Project folder
where
you
want
to
store
the
project,
and
click
Next.
C.
Select
Add
blank
vi
to
target,
and
click
Next.
D.
Select
the
Networked
option
for
Browse
targets,
and
click Browse.
• Cl
e?l
te n
ew
l
?~bV
IE
W
R
ea
l-Time pr
ojec
t
Select
pro;ec
t type,
name
, and
folder
Project type
lcustompro}ect
~
Applicatioo
ncludes
deterministic
COI'l'\XInenl:s
C
hec
kilgthisboxwillrestrictoptioosonthenextpageto
ensure the
pro)e
ct
can
nn
a determ
ii
stic
loop
Project
name
I
PartVM:I<!~tioo
Project
folder
C:\Program
Files\National
l
nstu
..
ments\W.X
~
r
~
Cr
·e?l
te n
ew
l
ab
V
IE
W R
ea
l-Time project -
Browsetaroets
@
Networked
Add
a networked tarqet, such as
PXJ,
Compact
FieldP
OOt,
FieldPo
nt
,
Compact
RIO,
Compact
Vi
sion
System
Q
Local
Add<!~loc<!~lt
<!~rget,
suc:h.!~sPCI-70-H
orRTXSt.bsystem
[
sr~e
... ]
Selected target
\
PilltVa~dation
c
EJ
~
II
~~
~
~~
E. Select
the
Existing target
or
device
option
from
Targets
and
Devices,
expand
the
Compact
Vision
System
branch,
select
your
device,
and
click
OK.
F.
G.
Click
Next.
Verify
that
the
Nl
CVS-1450
device
appears
correctly
in
the
LabVIEW
Real-Time
Project,
and
click
Finish.
H.
In
the
Project
Explorer
window,
right-click
the
name
of
your
Nl
CVS-1450
device
,
and
select
Add
File
.
I.
Navigate
to
Program
Files\
Na
t
io
na l
In
s t r ume
nt
s\
L
abV
IE
W 8 .
0\
e
xa
mp l
es\
I
MAQ
\ I
MAQ
13
9 4
examples
.llb
,
and
click
Add
File
.
J.
Click
Grab
.
vi
,
and
click Select.
r
-m
Add Tar
ge
ts
and
Devices
-----
Targets and Dev
ic
es
0 EHisting
target
or
device
Dis
cover an existing tar
ge
t(s) or device(s),
0 EHisting
device
on
remote
subnet
Speci
fy a device
on
a remote su
bne
t by a
dd
r
ess.
0 New
target
or
device
Create a
new
target
Of
device
by type
S
f::l
_
Compac
t V
.i
si
on
Syst
em
~
Par
tVahda
ti
on
(!}
Rea
l-
Time
Desktop
l±l
Rea
l-
Time
PX
I
• Cr
ea
te new l a bV
IE
WR
e;.,
I-Time
pr
ojec
t
lr
''";'"'"'"'
B
~
Project:PartValidation.lvproj
8
I!
My
Computer
~
::;~~;:;:ions
8
rQ
PartValidat
io
n
(192.
1
68.1
0.12)
LH::itl
ed.vi
Dependencies
••• BuildSpeclications
~
Op
e
nVIswhenf
n
ish
e d
8 ·
~
Project: PartValidation.lvproj
(
~
J
My Computer
WDependencies
, -·
"'
Build
Sp
ecifications
B·
~
PartValidation
(10.0.58
.137)
.
~
Untitled.vi
. .
~
Dependencies
L.
"'
Build
Sp
ecifications
K.
Click
the
Run
button
to
begin
acquiring
images
.
Now
that
you
are
acquiring
images
in
Lab
VIEW,
you
can
use
the
Nl
Vision
Development
Module
and
the
installed
Nl
CVS-1450
device
drivers
to
process
images
and
to
control
inputs
and
outputs
.
Artisan Technology
Group·
Quality Instrumentation
...
Guaranteed 1 (888) 88-SOURCE 1 www.artisantg.com

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Other manuals for NI Vision CVS-1450 Series
5
Table of contents
Other National Instruments All In One Printer manuals