4/8
N 50, Induction hob with integrated ventilation
system, 80 cm
T48CB1AX2
Features
replenishment re-order option (replenishment cleanAir filter set
HEZ9VRCR0).
For ducted extraction configuration: 2 x 2 sets of directly
integrated, high-performance low-noise acoustic filters for
significantly lower noise and improved psycho-acoustics.
●- Optimised odour reduction performance for cooking applications
with complex odour molecules (e.g. fish).
●- Large scale filter surface with high odour reduction capabilities.
●- Lifetime of 360 hours of cooking (non-regenerative).
●- Low-noise filters with optimised psycho-acoustics.
●- Easy-to-access and easy-to-remove from above.
●- Replenishment cleanAir filter set Z821VR0.
●For ducted extraction configuration: 2 x 2 sets of directly
integrated, high-performance low-noise acoustic filters for
significantly lower noise and improved psycho-acoustics.
Planning & installation notes
●Suitable for ducted or recirculated extraction configuration (incl.
differentiated software modes). Respective mandatory installation
accessories required:
- Z811DU0 for ducted extraction.
- Starter kit Z821UD0 for unducted recirculation with cleanAir
odour filters.
- Z821PD0 for fully ducted and partly-ducted recirculation with
cleanAir odour filters.
●- Z811DU0 for ducted extraction.
●- Z821PD0 for fully ducted and partly-ducted recirculation
with cleanAir odour filters. Starter kit Z821UD0 for unducted
recirculation with cleanAir odour filters.
●Planning suggestions:
- Installation is possible in island as well as wall oriented
configurations.
- The product complies with the Needle Flame Test (according to
IEC 60695-5-11), the V2 flammability class (according to UL94)
and the B1 building material class (DIN 4102-1). The starter
kit HEZ9VRUD0 for unducted recirculation complies with these
standards as well.
- The max. immersion depth is 223mm below glass for top
mounted appliances and 227mm for flush installed appliances.
- The appliance must be freely accessible from below (i.e. for
accessing the lower liquid safety collector). - No false floor
is necessary below the cooktop with integrated downdraft
ventilation system. The drawers and/or shelves in the floor unit
must be removable. The backpanel of the floor unit can be kept -
only a cut-out for the air outlet is needed (position and size can be
taken from the installation instructions).
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted
recirculation requires a vertical aperture of min. 25mm behind the
backpanel of the furniture. Suggested for ideal performance are
50mm.
- The minimum worktop thickness is 16mm for top mounted and
flush installed appliances with the standard installation system.
Installation in even thinner worktops is also possible with the
spare part: content 626792.
- The overall appliance weight is 26kg - the bearing capacity and
stability, in the case of very thin worktops in particular, must be
supported using suitable substructures. The overall appliance
weight and the worktop manufacturer's structural integrity
specifications are to be taken into account.
- The "Plug 'n Play" starter kit HEZ9VRUD0 for unducted
recirculation enables easy and quick installations and can be
planned in all worktop depths ≥60cm. For ducted installations
- in ducted extraction (HEZ9VEDU0) as well as fully or partly
ducted recirculation (HEZ9VRPD0) - a worktop depth of ≥70cm is
required.
- For partly ducted and unducted recirculation extraction
installations, a return-flow aperture of ≥400cm² is to be respected
in the plinth area. The aperture can be realized via outlet grids,
lamella grids or subtly shortened plinths depending on the
assortment of the kitchen furniture manufacturer.
- The air outlet on the backside of the appliance can directly be
accessed with a male flat duct element (DN 150).
- The pressuredrop resistant blower allows longer and more
complex ductings up to 8m with three 90° bows while keeping
sufficient performance.
- When installing a ventilation hood with ducted extraction
and a chimney-vented fireplace, the power supply line of the
appliance needs a suitable safety switch. This is not required for
configurations in recirculated extraction.
- In ducted extraction configuration a one-way flap (or backflow
trap) with a maximum opening pressure of 65Pa should be
installed.
●- Installation is possible in island as well as wall oriented
configurations.
●- The product complies with the Needle Flame Test (according to
IEC 60695-5-11), the V2 flammability class (according to UL94)
and the B1 building material class (DIN 4102-1). The starter
kit Z821UD0 for unducted recirculation complies with these
standards as well.
●- The max. immersion depth is 223mm below glass for top
mounted appliances and 227mm for flush installed appliances.
●- The appliance must be freely accessible from below (i.e. for
accessing the lower liquid safety collector).
●- No false floor is necessary below the cooktop with integrated
downdraft ventilation system. The drawers and/or shelves in the
floor unit must be removable. The backpanel of the floor unit can
be kept - only a cut-out for the air outlet is needed (position and
size can be taken from the installation instructions).
●- The "Plug 'n Play" starter kit Z821UD0 for unducted recirculation
requires a vertical aperture of min. 25mm behind the backpanel of
the furniture. Suggested for ideal performance are 50mm.
●- The minimum worktop thickness is 16mm for top mounted and
flush installed appliances with the standard installation system.
Installation in even thinner worktops is also possible with the
spare part: content 626792.
●- The overall appliance weight is 26kg - the bearing capacity and
stability, in the case of very thin worktops in particular, must be