Netway NetWay4EWP User manual

More than just power.TM
DOC#: NetWay4EWP Rev. 090616
I.T.E. 43KC
™
Embedded
4-Port Ethernet over Fiber
PoE+ Hardened Switches
Installation Guide
Models include:
NetWay4EWP
- Includes Fiber Optic SFP 1G Link,
4-port PoE+ switch and power supply.
- NEMA4/4X, IP66 rated Outdoor enclosure.
NetWay4EWPX
- Includes Fiber Optic SFP 1G Link,
4-port PoE+ switch and power supply.
- NEMA4/4X, IP66 rated Outdoor enclosure.
- Accommodates up to four (4)
12VDC/4AH batteries.
NetWay4EX
- Includes Fiber Optic SFP 1G Link,
4-port PoE+ switch and power supply.
- NEMA1 rated Indoor enclosure.
NetWay4EWPN
- Includes Fiber Optic SFP 1G Link and
4-port PoE+ switch
(uses external power supply).
- NEMA4/4X, IP66 rated Outdoor enclosure.
NetWay4EPL
- Includes Fiber Optic SFP 1G Link,
4-port PoE+ switch and power supply.
- Backplane version.
(Not currently evaluated by UL)
NetWay4EB
- Fiber Optic SFP 1G Link and
4-port PoE+ switch
- Board only.
(Not currently evaluated by UL)

- 2 - NetWay4E Series
Overview:
Altronix NetWay Spectrum Indoor/Outdoor PoE+ Hardened Switches provide a 1Gb SFP port and four (4) PoE+
(30W) ports or up to two (2) Hi-PoE (60W) ports, passing data and power to PoE/PoE+ compliant devices.
Cameras/edge devices may be located up to 100m from the unit. Features also include an integral battery charger
for applications requiring backup and embedded LINQ Technology to monitor, control and report power and
diagnostics from anywhere.
Features:
Input:
• 115VAC, 60 Hz, 2.5A or 230VAC, 50/60 Hz, 1.3A.
NetWay4EB/NetWay4EWPN:
48-55V UL Listed ITE power supply (up to 120W)
Power Output:
• Four (4) ports PoE+ (30W) or up to
two (2) Hi-PoE (60W) ports.
• IEEE 802.3at (30W) and IEEE 802.3af (15W)
compliant.
• 120W total power.
• Integral surge protection.
Fiber Port:
• One (1) Gigabit SFP ports.
• Use with SFP module 1000Base-X (1Gb),
compliant to Class 1 laser product (not included).
Ethernet Ports:
• Four (4) 10/100/1000 Mbps ports.
• Connectivity: RJ45, auto-crossover.
• Wire type: 4-pair CAT5 or better structured cable.
• Distance: up to 100m.
• Speed: 10/100/1000 Mbps, half/full duplex,
auto negotiation.
Battery Backup:
• Built-in charger for sealed lead acid or
gel type batteries.
• Automatic switch over to stand-by battery
when AC fails.
LEDs:
• Individual PoE On LEDs for each port.
• Individual IP Link status, 10/100Base-T/active
LEDs for each port.
• ALOS LED indicates fiber connection for SFP port.
• Heartbeat LED indicates proper operation of the unit.
Environmental:
• Refer to Technical Specifications Chart on page 4
for Environmental Conditions.
Applications:
• Provides PoE / PoE+ / Hi-PoE for cameras/devices.
LINQ Technology:
• Remote network management allows for camera/
device reset and monitoring.
• Provides local and/or remote access to critical
information via LAN/WAN.
• Email and Windows Dashboard Alert notifications
report real-time diagnostics.
• Event log tracks history.
Accessories:
NetWaySP1A
• Ethernet over Fiber Media Converter/Repeater -
for applications requiring an additional SFP (Fiber)
port (Fig. 3, pg. 6).
Mechanical:
NetWay4EWP
• NEMA4/4X, IP66 Rated enclosure for outdoor use.
• Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.1mm x 287.3mm x 142mm).
NetWay4EWPN
• NEMA4/4X, IP66 Rated enclosure for outdoor use.
• Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59”
(338.1mm x 287.3mm x 142mm).
NetWay4EWPX
• NEMA4/4X, IP66 Rated enclosure for outdoor use.
• Accommodates four (4) 12VDC/4AH batteries
(48V of backup).
• Dimensions (H x W x D approx.):
17.53” x 15.3” x 6.67”
(445.3mm x 388.6mm x 169.4mm).
NetWay4EX
• Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 83mm).
NetWay4EPL
• Dimensions (H x W x D approx.):
10.75” x 8.875” x 2.375”
(273.1mm x 225.4mm x 60.3mm).
NetWay4EB
• Dimensions (L x W x D approx.):
6.25” x 4.5” x 0.625”
(158.8mm x 114.3mm x 15.9mm).
Agency Listings:
• UL/cUL Listed for Information Technology Equipment (UL 60950-1),
Information Technology Equipment to Be Installed Outdoors (UL 60950-22).
• CE approved.

NetWay4E Series - 3 -
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local
codes and authorities having jurisdiction. All units should be installed by a trained service personnel.
NetWay4EWP/4EWPN/4EWPX Enclosure Mounting and Installation:
1. Remove backplane from enclosure prior to drilling. Do not discard hardware.
Note: Make sure that hardware will not interfere with components of the circuit board.
2. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to
be used are 0.5”. Follow manufacturer’s specifications for the appropriate size opening.
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.
3. Clean out the inside of enclosure before remounting circuit board.
4. Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pgs. 11-12):
Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of
the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors;
bolts and locking nuts, etc.) that are compatible with mounting surface and are of sufficient
length/construction to ensure a secure mount (Fig. 5, pg. 8).
Pole Mount: Refer to Figs. 6 - 10, pg. 8.
NetWay4EWPX only: In order to properly mount NetWay4EWPX on a pole using
Altronix PMK1, additional holes need to be drilled in the enclosure’s flanges, so the distance
between those holes is 10”.
5. Mount backplane in enclosure with hardware.
6. To facilitate wire entry utilize weather-tight NEMA rated connectors (supplied), bushings, and cable.
NetWay4EX Enclosure Mounting and Installation:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding.
Place the enclosure’s upper keyholes over the two (2) upper screws; level and secure. Mark the position of
the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the
enclosure’s upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to
tighten all screws (Enclosure Dimensions, pg. 9). Secure enclosure to earth ground.
NetWay4EB/4EPL Mounting and Installation:
1. Mount board/backplane in the desired location/enclosure with hardware supplied.
2. NetWay4EB: Connect 56VDC/120W max power source to terminal marked [+] and [–].
Installation:
1. NetWay4EWP, NetWay4EWPX, NetWay4EX, and NetWay4EPL:
Before powering unit, set input voltage selection switch to proper Input Voltage position (Fig. 3a, pg. 6).
Units are factory set for 115VAC.
2. Secure cabinet to earth ground. Connect AC power from overcurrent protective device circuit breaker
(20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on power supply board
(Fig. 3, pg. 6). Use 14AWG or larger for all power connections (Battery, DC output, AC input).
Connect ground lug to earth or green branch wire (12AWG min.).
Note: For NetWay4EWPN use external 48-55V UL Listed ITE power supply, carefully observing
correct polarity (Fig. 4, pg. 7).
Keep power-limited wiring separate from non power-limited wiring by utilizing separate knockouts/
inlets. Minimum 0.25” spacing must be provided.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing
equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified
service personnel.
3. Port Configurations (Fig. 1, pg. 3; Fig. 3b, pg. 6):
Jumper
Jumper
Position
Structured Cable Ports
1234
PORT 2 30W 30W and
Data
30W and
Data – –
PORT 4 30W – – 30W and
Data
30W and
Data
PORT 2 60W Data Only 60W and
Data – –
PORT 4 60W – – Data Only 60W and
Data
30W 60W
PORT 2
Fig. 1

- 4 - NetWay4E Series
4. Connect structured cables from port marked [Port 1] to [Port 4] on NetWay unit to PoE compliant
cameras/edge devices (Fig. 3, pg. 6).
Note: All interconnected devices must be UL Listed.
5. Insert SFP module into port marked [SFP], then connect cable to the SFP module on NetWay4EB to the
corresponding input of an SFP switch (Fig. 3, pg. 6).
6. Battery Backup (if desired): Connect four (4) 12VDC batteries wired in series to terminals marked
[+ BAT –] (Fig. 3, pg. 6), carefully observing polarity.
When use of stand-by batteries is desired, they must be lead acid or gel type.
Note: When batteries are not used, a loss of AC will result in the loss of output voltage.
7. Please ensure that the cover is secured with:
Key lock and screws for NetWay4EX, security bolt for NetWay4EWP, NetWay4EWPN and
NetWay4EWPX.
Recommended Altronix SFP Modules:
Altronix P1MM and P1SM10 are hot-pluggable SFP fiber transceiver modules and are readily usable with all
Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
P1MM - For use with Multi-Mode Fiber for distances up to 550m.
P1SM10 - For use with Single-Mode Fiber for distances up to 10km.
Technical Specifications:
Parameter Description
Number of Ports Four (4) IEEE 802.3af (15W) and IEEE 802.3at (30W) compliant or
two (2) Hi-PoE (60W). One (1) Gigabit SFP Port.
Input Power
Requirements
115VAC, 60Hz, 2.5A or 230VAC, 50/60Hz, 1.3A.
NetWay4EB/NetWay4EWPN: 48-55V UL Listed ITE power supply
Environmental
Conditions
Operating Ambient Temperature:
NetWay4EWP/NetWay4EWPX: 60W: -40ºC to 75ºC (-40ºF to 167ºF);
75W: -40ºC to 70ºC (-40ºF to 158ºF);
100W: -40ºC to 55ºC (-40ºF to 131ºF);
120W: -40ºC to 45ºC (-40ºF to 113ºF).
NetWay4EX: 120W: -40ºC to 50ºC (-40ºF to 122ºF).
NetWay4EB/NetWay4EWPN: 120W: -40ºC to 75ºC (-40ºF to 167ºF).
Relative Humidity: 85%, +/- 5%
Storage Temperature: -40ºC to 85ºC (-40ºF to 185ºF).
Operating Altitude: -304.8 to 2,000m.
Weights (approx.)
Model Product Weight Shipping Weight
NetWay4EWP
NetWay4EWPN
NetWay4EWPX
NetWay4EX
NetWay4EPL
NetWay4EB
10.32 lbs. (4.68kg)
7.7 lbs. (3.49kg)
15 lbs. (6.8 kg)
6.65 lbs. (3.02 kg)
2.6 lbs. (1.18 kg)
0.25 lbs. (0.11 kg)
11.7 lbs. (5.3kg)
10.0 lbs. (4.54kg)
17.5 lbs. (7.9kg)
7.55 lbs. (3.42kg)
4.0 lbs. (1.81kg)
0.75 lbs. (0.34kg)
Configuring Units for Network Connection
Please be sure to visit altronix.com for latest firmware and
installation instructions
Factory Default Settings
• IP Address: 192.168.168.168
• User Name: admin
• Password: admin
1. Set the static IP address for the laptop to be used for programming to the same network IP address as the
Netway4E. The default address of the Netway4E is 192.168.168.168, E.I. 192.168.168.200.
2. Connect one end of the network cable to the network jack on the Netway4E and the other to the network
connection of the laptop.

NetWay4E Series - 5 -
3. Open a browser on the computer and enter “192.168.168.168” into the address bar.
A dialog box Authentication Required will appear requesting both user name and password.
Enter the default values here. Click on the button labeled Log In.
4. The status page of the NetWay4E will appear. Click on the tab labeled Network Settings.
This will open the Network Setting screen. In this screen the MAC Address of the NetWay4E module will
be found along with the Network Settings and Email Settings.
Network Settings:
In the IP Address Method field select the method that the IP Address for the NetWay4E will be obtained
(STATIC or DHCP), then follow the appropriate steps.
Static:
A. IP Address: Enter the IP address assigned to the NetWay4E by the network administrator.
B. Subnet Mask: Enter the Subnet of the network.
C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
Gateway configuration is required to properly receive emails from the device.
D. HTTP Port: Enter the HTTP port number assigned to the NetWay4E module by the network
administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not
encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily
for use with LAN connections.
E. HTTPS Port: Enter the HTTPS port number assigned to the NetWay4E module by the network
administrator to allow remote access and monitoring. The default inbound port setting is 443.
Being encrypted and more secure, HTTPS is highly recommended for remote access.
F. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
DHCP:
A. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
Next, click on the button labeled Reboot Server. After rebooting the NetWay4E will be set in the DHCP
mode. The IP address will be assigned by the router when the NetWay4E is connected to the network.
It is recommended to have the assigned IP Address reserved to ensure continued access
(see the network administrator).
B. Subnet Mask: When operating in DHCP, the router will assign the subnet mask values.
C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
D. HTTP Port: Enter the HTTP port number assigned to the NetWay4E module by the network administrator
to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and
unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with
LAN connections.
E. HTTPS Port: Enter the HTTPS port number assigned to the NetWay4E module by the network
administrator to allow remote access and monitoring. The default inbound port setting is 443.
Being encrypted and more secure, HTTPS is highly recommended for remote access.
F. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
Heartbeat Timer:
The heartbeat timer will send a trap message indicating that the NetWay4E is still connected and communicating.
Setting the Heartbeat Timer:
1. Click the button labeled Heartbeat Timer Setting.
2. Select the desired time between heartbeat messaging in the Days, Hours, Minutes and Seconds in
corresponding fields.
3. Click the button labeled Submit to save setting.
Factory Reset Option:
1. Power the unit down. Allow approximately 30 seconds
for the unit to power down completely.
2. Depress Factory Reset button on NetWay4EB while
reapplying power to the unit (Fig. 2, pg. 5; Fig. 3c, pg. 6).
Continue holding the button until the LEDs on board go
through the start up cycle, then release the button.
3. The unit returns to the original factory settings.
Fig. 2
NetWay4EB
Factory Reset
Factory Reset

- 6 - NetWay4E Series
Typical Applications:
Fig.3
115/230VAC
Input
115/230VAC
Input
NetWay4EB
Factory Reset
PORT 1
30W
PORT 2
30W / 60W
PORT 3
30W
PORT 4
30W / 60W
230VAC 115VAC
5A 250VA
SFP
+ INPUT ---
--- DC ++ BAT –
To Stand-by
Batteries
230VAC 115VAC
LGN
230VAC 115VAC
5A 250VA
--- DC ++ BAT –
To Stand-by
Batteries
To Input of
NetWay4EWP
board
230VAC 115VAC
Factory Reset
IP PoE/PoE+
Device
IP PoE/PoE+
Device
IP PoE/PoE+
Device
Fiber to
Switch
IP PoE/PoE+
Device
30W
PORT 4
PORT 2
60W
30W 60W
Input Voltage
Selection Switch Cable Guide
Input Voltage
Selection Switch
LG N
Separate
Inlets
30W 60W
Operation
Fig. 3a
Fig. 3c
Fig. 3a
NetWay4EX - Power Supply Board Orientation NetWay4EWP and NetWay4EWPX
Power Supply Board Orientation
Fig. 3b

NetWay4E Series - 7 -
Typical Applications:
Fig. 4
NetWay4EWPN – Typical Application with Composite Cable
Power Distance Chart
Power Requirements Power Cabling Maximum Distance (ft./m)
15W 12/2 11,162’ / 3403m
30W 12/2 5,581’ / 1702m
45W 12/2 3,767 / 1,148m
60W 12/2 2,739’ / 835m
75W 12/2 2,249’ / 686m
90W 12/2 1,872’ / 571m
105W 12/2 1,607’ / 490m
120W 12/2 1,408’ / 429m
15W 16/2 4,415’ / 1,346m
30W 16/2 2,207’ / 673m
45W 16/2 1,490’ / 454m
60W 16/2 1,083’ / 330m
75W 16/2 889’ / 271m
90W 16/2 740’ / 226m
105W 16/2 635’ / 194m
120W 16/2 557’ / 170m
Estimated distances based on starting voltage of 56VDC and accounts for a 10 volt drop.
All distances are per IEEE 802.3at standard for device power requirements of minimum
44VDC and leave an approximate 2 volts for safety and flexibility.
IP PoE/PoE+
Device
IP PoE/PoE+
Device
Carefully
observe
polarity
IP PoE/PoE+
Device
IP Hi-PoE
Device
IP Hi-PoE
Device
IP PoE/PoE+
Device
Port 2 and port 4 are
configurable for 60W (120W max)
(Refer to Fig. 4a, pg. 7)
NetWay4EB
Factory Reset
PORT 1
30W
PORT 2
30W / 60W
PORT 3
30W
PORT 4
30W / 60W
SFP
+ INPUT ---
30W 60W
30W 60W
30W 60W
Operation
PORT 4
PORT 2
Carefully observe polarity
Composite
Cable
Fiber Switch
48-55V UL Listed
ITE Power Supply

- 8 - NetWay4E Series
Wall Mount Installation
1- Place unit at desired location and secure with mounting
screws (not included) (Fig. 5, pg. 8).
Fig. 5
Pole Mounting Using Optional Pole Mount Kit PMK1 (not included):
This installation should be made by qualified service personnel. This product contains no serviceable parts.
PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3
and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included).
1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 6, pg. 8).
2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open
end of the strap through the locking mechanism on the strap, then tighten the screw with
flat head screwdriver or 5/16” hex socket driver (Fig. 7, pg. 8 and Fig. 9, pg. 8).
3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the
bracket, tightening bolts with a 7/16” hex socket (Fig. 8, pg. 8).
4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket
(Fig. 6, pg. 8).
5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket,
tightening bolts with a 7/16” hex socket (Fig. 8, pg. 8).
6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking
mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver
(Fig. 6, pg. 8).
7. Clip excess straps.
Fig. 6 Fig. 7 Fig. 8
Fig. 9
Fig. 10
2” to 8”(50.8mm to 203.2mm)
diameter round pole
Fig. 10a
5” (127mm) square pole

- 9 - NetWay4E Series
NetWay4EX
Mechanical Drawing and Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
1.40”
(36mm)
1.40”
(36mm)
4.85”
(123mm)
4.85”
(123mm)
1.40”
(36mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
13.0”
(330mm)
5.10”
(130mm)
6.5625”
(167mm)
1.20”
(31mm)
1.20”
(31mm) 1.20”
(31mm)
3.25”
(83mm)
3.25”
(83mm)
3.25”
(83mm)
3.25”
(83mm)
1.0”
(25mm)
1.0”
(
25mm
)
10.5”
(
267mm
)
1.0”
(
25mm
)
1.0”
(25mm)
0.75”
(19mm)
0.75”
(19mm)
0.9375”
(24mm)
0.9375”
(24mm)
11.0”
(279mm)
12.5”
(318mm)

- 10 - NetWay4E Series
NetWay4EPL
Mechanical Drawing and Dimensions (H x W x D approx.):
10.75” x 8.875” x 2.375” (273.1mm x 225.4mm x 60.3mm)
8.875” (225.4mm)
8.25” (209.5mm)
0.25”
(6.4mm)
10.75”
(273.1mm)
10.25”
(260.3mm)

- 11 - NetWay4E Series
NetWay4EWP and NetWay4EWPN
Mechanical Drawing and Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm)
1.61”
(40.9mm)
3.96”
(100.6mm)
5.59”
(142mm)
10-32 X 0.375” (9.6mm)
BRASS INSERT (X4)
STAINLESS STEEL PIANO HINGE
11.31”
(287.3mm)
13.31”
(338.1mm)
PADLOCK LATCH ATTACHED WITH RIVETS
(Ø 0.375” (9.5mm) PADLOCK EYE).
10.75” (273.1mm)
10.00”
(254mm)
8.25” (209.6mm)
10.25”
(260.4mm)
12.00”
(304.8mm)
13.50”
(342.9mm)
10-32 X 0.25” (6.4mm)
BRASS INSERT (X2)
Ø 0.32 (8.1mm) MOUNTING HOLE
TYP. 4 PLACES
12.75”
(323.9mm)
8.00” (203.2mm)

- 12 - NetWay4E Series
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
IINetWay4E Series C13R MEMBER
FRONT VIEW COVER REMOVEDRIGHT SIDE VIEWFRONT VIEW
END VIEW
SECTION A-A
AA
316 STAINLESS STEEL
PADLOCK LATCH AT TACHED
WITH RIVETS. Ø.375 PADLOCK EYE
17.36”
441 mm
12.00”
304.8mm
6.41”
162.8mm
10-32 X .250
BRASS INSERT
4 PLCS.
14.54” (369.3mm)
16.74”
425.2mm
0.125” (3.2mm)
14.25”
362mm
14.00” (355.6mm)
12.23” (310.6mm)
17.53”
445.3mm
16.00”
406.4mm
1.67”
42.4mm
5.00”
127mm
16.73”
425mm
15.3”
388.6mm
6.67”
169.4mm
4.94”
125.5mm
5.77”
146.6mm
0.75”
19.1mm
MOUNTING PLATE
Ø.32” (8.1mm)
WALL MOUNTING HOLE X 4
NetWay4EWPX
Mechanical Drawing and Dimensions (H x W x D approx.):
17.53” x 15.3” x 6.67” (445.3mm x 388.6mm x 169.4mm)
Other manuals for NetWay4EWP
1
This manual suits for next models
5
Table of contents
Other Netway Switch manuals