Nordair Niche WA 100 Assembly instructions

Doc No. 703500 Page of 32
INDEX Section
Introduction and Document Index
Technical Information ------------------------------------------------------ 1
Dimensions ------------------------------------------------------------------- 2
Packaging, Handling and Transportation ------------------------------ 3
Installation -------------------------------------------------------------------- 4
Health and Safety ----------------------------------------------------------- 5
User and Operating Instructions ----------------------------------------- 6
Maintenance ----------------------------------------------------------------- 7
Dismantling ------------------------------------------------------------------ 8
Part No. 703500
Nortek Global HVAC (UK) Limited, Fens Pool Avenue, Brierley Hill, West Midlands, DY5 1QA
WA & RA EWA & RA EVAPORATIVEVAPORATIVE CCOOLERSOOLERS
AASSEMBLYSSEMBLY IINSTALLATIONNSTALLATION ANDAND SSERVICINGERVICING MMANUALANUAL
WARNINGS
Nortek Global HVAC (UK) Ltd equipment must be installed and maintained in accordance with
any relevant obligations arising from the Health and Safety at Work Act 1974 or relevant codes
of practice. In addition the installation must be carried out in accordance with the current IEE
wiring regulations (BS 7671) and any other relevant British Standards and Codes of Practice by
a qualified installer.
All external wiring MUST comply with the current IEE wiring regulations.

Doc No. 703500 Page 2 of 32
Document Index.
GENERAL INFORMATION...............................................................................................................................4
User Information.............................................................................................................................................4
SECTION 1 – TECHNICAL INFORMATION.....................................................................................................4
1.1 Machine identification data.......................................................................................................................4
1.2 Introduction...............................................................................................................................................4
1.3 Technical information ...............................................................................................................................5
1.4 Warnings ..................................................................................................................................................6
1.5 Control Panels..........................................................................................................................................6
1.6 Improper use ............................................................................................................................................6
SECTION 2 – DIMENSIONS .............................................................................................................................7
2.1 RA100.......................................................................................................................................................7
2.2 RA200.......................................................................................................................................................7
2.3 RC100 ......................................................................................................................................................8
2.4 RC200 ......................................................................................................................................................8
2.5 WA100/150...............................................................................................................................................9
SECTION 3 – PACKAGING, HANDLING AND TRANSPORTATION .............................................................9
3.1 Delivery of the unit....................................................................................................................................9
3.2 Handling and transportation.....................................................................................................................9
3.3 Lifting......................................................................................................................................................10
3.3.1 Lifting with fork lift ...........................................................................................................................12
3.3.2 Lifting with cables............................................................................................................................12
3.4 Unpacking the equipment.......................................................................................................................10
3.5 Storage...................................................................................................................................................10
SECTION 4 – INSTALLATION........................................................................................................................11
4.1 General Warnings WA evaporative cooling units...................................................................................11
4.2 Positioning and Installation of the WA evaporative cooling units...........................................................11
4.2.1 Wall installation...............................................................................................................................11
4.2.2 Window installation.........................................................................................................................11
4.3 General Warnings RA/RC evaporative cooling units .............................................................................12
4.4 Positioning and Installation of the RA/RC evaporative cooling units .....................................................12
4.4.1 RA roof installation..........................................................................................................................12
4.4.2 RC roof installation..........................................................................................................................14
4.4.3 RC wall window installation ............................................................................................................15
4.4.4 RA wall window installation.............................................................................................................15
4.5 Installation ..............................................................................................................................................16
4.6 Connection to the power supply.............................................................................................................16
4.7 Wiring diagrams......................................................................................................................................17
4.7.1 Control panel with Temperature probe...........................................................................................17
4.7.2 Schematic wiring RA150.................................................................................................................18
4.7.3 Schematic wiring RA200.................................................................................................................18
4.7.4 Schematic wiring RC100 ................................................................................................................19
4.7.5 Schematic wiring RC200 ................................................................................................................20
4.7.6 Multiple coolers...............................................................................................................................21
4.7.7 Multiple coolers via Router .............................................................................................................22
4.7.8 Multiple coolers via two Routers.....................................................................................................23
4.8 Connection to the water supply..............................................................................................................24
SECTION 5 – HEALTH AND SAFETY ...........................................................................................................24
5.1 Protection devices..................................................................................................................................24
5.2 Clothing ..................................................................................................................................................24
5.3 Residual risks.........................................................................................................................................24
5.4 Emergency situations.............................................................................................................................24

Doc No. 703500 Page 3 of 32
SECTION 6 – USER INSTRUCTIONS............................................................................................................25
6.1 General...................................................................................................................................................25
6.2 First start-up ...........................................................................................................................................25
6.3 Remote Command Unit..........................................................................................................................26
6.3.1 Command and signal descriptions..................................................................................................26
6.3.1.1 Command descriptions.........................................................................................................26
6.3.1.2 Signal descriptions................................................................................................................27
6.4 Switching on...........................................................................................................................................27
6.5 Switching off...........................................................................................................................................27
6.6 Starting mode.........................................................................................................................................27
6.6.1 Manual start up...............................................................................................................................27
6.6.2 Automatic start up...........................................................................................................................27
6.7 Settings...................................................................................................................................................27
6.7.1 Setting current time.........................................................................................................................27
6.7.2 Setting ON / OFF periods ...............................................................................................................28
6.7.3 Reading a restored program...........................................................................................................28
6.7.4 Modifying a programme..................................................................................................................28
6.7.5 Deleting a stored programme.........................................................................................................28
6.7.6 Changing the Temperature and Humidity values...........................................................................28
6.7.7 Locking/unlocking remote control unit ............................................................................................29
6.8 Operating Mode......................................................................................................................................29
6.8.1 Cooling............................................................................................................................................29
6.8.2 Ventilation.......................................................................................................................................29
6.9 Operating Faults.....................................................................................................................................30
6.10 Bus system...........................................................................................................................................30
SECTION 7 – MAINTENANCE .......................................................................................................................30
7.1 End-of-Season Maintenance..................................................................................................................30
7.2 Pre-Season Maintenance.......................................................................................................................30
7.3 Maintenance Safety Regulations............................................................................................................31
7.3.1 Clothing...........................................................................................................................................31
7.3.2 Unit warnings ..................................................................................................................................32
7.3.3 Residual risks..................................................................................................................................32
7.3.4 Unit warnings ..................................................................................................................................32
7.4 Technical assistance requests...............................................................................................................32
SECTION 8 – DISMANTLING.........................................................................................................................32
8.1 Disposal..................................................................................................................................................32

Doc No. 703500 Page 4 of 32
General Information
The contents of this document are for
information purposes only and are subject to
modifications without notice;
This manual must be kept in the project file
until final machine dismantling and if the
machine is sold, it must be passed to the
new owner.
If a fault occurs causing machine stoppage,
AmbiRad Limited is not liable in any way for any
damages caused by the stoppage and in no way
is the warranty period extended.
User Information
This manual is to be considered an integral
part of the machine and must be filed in an
accessible place for the workers that use
and maintain the machine.
The workers using and maintaining the machine
must be fully aware of its contents before the
machine is placed in service.
If the manual is misplaced or damaged,
immediately request a copy by contacting
Technical Assistance Service at AmbiRad
Limited, indicating the identification data of the
plant shown on the machine identification plate
and on the cover of this manual.
The machine is conforming to the following
European Community Directives:
2006/42/EEC Machinery Directive
2006/95/EEC Low Voltage Directive
2004/108/EEC EMC Directive
UNDER NO CIRCUMSTANCES MAKE MODIFICATIONS TO THE MACHINE AND
ITS INTENDED USE.
AmbiRad Limited declines all responsibility for any damages which may be,
directly or indirectly, caused to exposed persons or property, due to improper
use or use of the machine for different purposes other than the design purposes,
incorrect installation, inappropriate power supply, different or changes to the
installation environment from the one declared during order confirmation, grave
deficiency of maintenance, unauthorized alterations and modifications, use of
non-original spare parts, removal of the protection guards, ignoring the
instructions for use, negligence, etc.
1. Technical Information.
1.1 Machine identification data
Machine identification data is shown on the
warranty sheet supplied to the customer and is
enclosed in the documentation and on the
machine identification plate.
1.2 Introduction
During the summer to improve the internal
environment within a production unit, warehouse
or other area, it is necessary to ventilate the
area with frequent changes of fresh, filtered and
possibly cool air. For large areas such as
industrial buildings, an air conditioning plant is
not practicable due to the large volume of air to
be cooled and the thermal loads of processes to
be neutralized, requiring very high energy load,
plus the cooling effect is reduced by the exhaust
air extraction plant and frequent opening of
doors during normal activity.
Evaporative cooling plants that cool the air using
a natural principle represent an optimal solution:
air passes through special wet water filters,

Doc No. 703500 Page 5 of 32
1.3 Technical Data
Unit WA 100
Maximum
Air Capacity Average
Minimum
m3/h
10000
7500
5000
Cooling Capacity (1) kW 15
Power Voltage V 230V – 50Hz
Current amps 3.7
Power Consumption kW 0.9
Water Consumption (average)* l/h 34
Water Inlet Ø in 3/8
Water Outlet Ø mm 60
Air Duct Size mm 600 x 600
Maximum Duct Length m 5+1 bend
Humidification Panel:
Thickness
Surface Area
Saturation Efficiency
mm
m²
%
100
2
88%
Dimensions : L x W X H mm 1300 x 670 x 1300
Weight (empty - full) kg 60 - 75
Noise Data
Outdoor (2)
Indoor
dB
A
Min/Max speed
49 / 65
49 / 66
WA 150
13000
9700
6500
19
230V – 50Hz
4.8
1.2
39
3/8
60
600 x 600
5+1 bend
100
2
88%
1300 x 670 x 1300
63 - 78
Min/Max speed
50 / 66
50 / 67
(1) test conditions: E. Temp. = 33°C-R. Hum 60%
(2) open field test, 4m distance
losing part of its heat during the evaporation
process of the water and hence lowering the air
temperature. The absence of refrigeration plant
reduces energy consumption to a minimum and
enables large volumes of air to be treated.
Unit RC 100 RA 150 RA 200 RC 200
Maximum
Air Capacity Average
Minimum
m3/h
10000
-
5000
13000
9700
6500
20000
15000
10000
20000
-
10000
Cooling Capacity (1) kW 15 19 30 36
Power Voltage V 400V - 50Hz (3pha) 230V - 50Hz 230V - 50Hz 400V - 50Hz (3pha)
Current amps 3.5 4.8 7.0 7.0
Power Consumption kW 1.6 1.2 1.8 3.2
Water Consumption (avg)* l/h 34 43 64 64
Water Inlet Ø in 3/8 3/8 3/8 3/8
Water Outlet Ø mm 60 60 60 60
Air Duct Size mm 600 x 600 600 x 600 600 x 1150 850 x 470
Maximum Duct Length m See graph page 5 5+1 bend 5+1 bend See graph page 6
Humidification Panel:
Thickness
Surface Area
Saturation Efficiency
mm
m²
%
100
2.7
88%
100
2.7
88%
100
3.4
88%
100
3.4
88%
Dimensions :
L x W X H mm 1150 x 1150x 1050 1150 x 1150x 1050 1650 x 1150x 1050 1650 x 1150x 1050
Weight (empty - full) kg 87 - 108 67 - 88 120 - 146 160 - 186
Noise Data
Outdoor (2)
Indoor
dBA
Min/Max speed
55 / 61
56 / 62
Min/Max speed
50 / 66
50 / 67
Min/Max speed
53 / 68
53 / 70
Min/Max speed
58 / 65
60 / 66
Static Pressure pa 80 n/a n/a 80
L
H
W
This manual suits for next models
5
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual