Olympus SZ2-ILST User manual

A X 6 6 1 3
INSTRUCTIONS
SZ2-ILST
LED ILLUMINATOR STAND
This instruction manual is for the Olympus SZ2-ILST LED Illuminator Stand. To ensure the safety,
obtain optimum performance and to familiarize yourself fully with the use of this equipment,
we recommend that you study this manual thoroughly before operating the system.
Retain this instruction manual in an easily accessible place near the work desk for future reference.

For Korea only
B급 기기 (가정용 방송통신기자재)
이 기기는 가정용(B급) 전자파적합기기로서 주로 가정에서 사용하는 것을
목적으로 하며, 모든 지역에서 사용할 수 있습니다.

IMPORTANT — Be sure to read this chapter for safe use of the equipment. —
1 NOMENCLATURE
2 ASSEMBLY
3 OPERATION
1Lighting the Illuminator and Adjusting the Light Intensity ....................................................... 5
2Adjusting the Reflected (Oblique) Illumination Angle .................................................................... 5
3Adjusting the Focus Adjustment Knob Tension ..................................................................................... 5
4 SPECIFICATIONS
PROPER SELECTION OF THE POWER SUPPLY CORD ............................................................................ 7-8
CONTENTS
3
4
5
6
1-2
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
FCC WARNING: Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
SZ2-ILST
In accordance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment,
this symbol indicates that the product must not be disposed of as unsorted municipal waste, but
should be collected separately.
Refer to your local Olympus distributor in the EU for return and/or collection systems available in your
country.

1
IMPORTANT
This manual pertains only to the operation of the LED illuminator stand. Please also read the
instruction manuals for the SZ2 series or applicable microscope to understand the comprehensive
operating instructions of the microscope system.
SAFETY PRECAUTIONS
1. After the equipment has been used in an observation of a specimen that is accompanied with a potential of infection,
clean the parts coming in contact with the specimen to prevent infection.
· Moving this product is accompanied with the risk of dropping the specimen. Be sure to remove the specimen before
moving this product.
· In case the specimen is damaged by erroneous operation, promptly take the infection prevention measures.
· The product becomes unstable if its height is increased by an accessory mounted on it. In this case, take anti-toppling
measures to prevent the specimen from being dropped when the product topples down.
2. When moving the microscope, hold the bottom of the base with one hand and the pillar with
the other hand, and carry the microscope without tilting it.
· Before carrying, remove the stage glass so that it will not drop during carrying.
Also remove other modules from the microscope as they may increase the weight and
increases danger.
3. LED (Light Emitting Diode) device is included in this product.
· Do not stare at the LED illumination (particularly the reflected illumination) light directly, as this may damage your eye.
· When a mirror or similar element is engaged in the illumination light path, take special care against the reflected light
that may enter your eye.
· Use of controls or adjustments performance of procedures other than those specified herein may result in hazardous
radiation exposure.
4. Always use the power cord provided by Olympus. If no power cord is provided, please select the proper power cord by
referring to the section “PROPER SELECTION OF THE POWER SUPPLY CORD” at the end of this instruction manual. If the
proper power cord is not used, product safety performance cannot be warranted.
5. Always ensure that the grounding terminals are properly connected. If the equipment is not grounded, Olympus can no
longer warrant the electrical safety performance of the equipment.
6. If water or a liquid is spilt on the top of the LED illuminator stand, treat it quickly and properly as described in
“
2 Maintenance and Storage” below.
Symbol Explanation
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
Before use, carefully read the instruction manual. Improper use could result in personal injury to
the user and/or damage to the equipment.
Safety Symbols
The following symbols are found on the equipment. Study the meaning of the symbols and always use the equipment in
the safest possible manner.
Indicates the transmitted light illumination.
Indicates the reflected light illumination.

SZ2-ILST
2
1Getting Ready
1. The LED illuminator stand is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe
impact.
2. Do not use the LED illuminator stand where it is subjected to direct sunlight, high temperature and humidity, dust or
vibrations. (For the operating conditions, refer to chapter 4, “SPECIFICATIONS” on page 6.)
3. The LED illuminator stand can be used with the following microscope bodies.
· SZ2 series microscopes (SZ51, SZ51-60, SZ61, SZ61-60 or SZ61TR) and SZX7
· Previous SZ series microscopes
4. Install the LED illuminator stand on a desktop surface that is as level as less than 3° from the horizontal plane, and the
mounted load should be less than 7 kilograms.
5. This equipment is not provided with the ESD (electro static discharge) compatibility.
6. The illumination performance cannot be manifested fully if an optional low-power auxiliary objective (SZ2 series) or
objective (SZX7) is used. (For details, see page 5.)
7. Light intensity does not change linearly with respect to the rotation of the light intensity knob.
8. The color hues may be variable depending on the variance of each LED.
9. The following modules cannot be mounted on this equipment.
· Stage plate
· Stage or stage adapter
· Oblique illuminator LSGA
· Coaxial reflected light illuminator SZ2-ILLC
2Maintenance and Storage
1. To clean the lenses and other glass components, simply blow dirty away using a commercially available blower and wipe
gently using a piece of cleaning paper (or clean gauze).
If a lens is stained with fingerprints or oil smudges, wipe it gauze slightly moistened with commercially available absolute
alcohol.
Since the absolute alcohol is highly flammable, it must be handled carefully.
Be sure to keep it away from open flames or potential sources of electrical sparks –– for example, electrical
equipment that is being switched on or off.
Also remember to always use it only in a well-ventilated room.
2. Do not attempt to use organic solvents to clean the parts other than the glass components. To clean them, use a lint-free,
soft cloth slightly moistened with a diluted neutral detergent.
3. The stage surface is provided with a simplified waterproof construction. If water is spilt on it, promptly set the main switch
to “ ” (OFF), unplug the power cord and wipe with a dry cloth.
If water penetrates inside the equipment, contact Olympus to have the electrical safety checked.
4. Do not disassemble any part of the equipment as this could result in malfunction or reduced performance.
3Caution
If the LED illuminator stand is used in a manner not specified by this manual, the safety of the user may be imperiled. In
addition, the equipment may also be damaged. Always use the equipment as outlined in this instruction manual.
The following symbols are used to set off text in this instruction manual.
: Indicates that failure to follow the instructions in the warning could result in bodily harm to the
user and/or damage to equipment (including objects in the vicinity of the equipment).
# : Indicates that failure to follow the instructions could result in damage to equipment.
} : Indicates commentary (for ease of operation and maintenance).
4Intended use
This instrument has been designed to be used to observe magnified images of specimens in routine and research
applications.
Do not use this instrument for any purpose other than its intended use.
This product complies with the requirements of directive 98/79/EC concerning in vitro diagnostic
medical devices. CE marking means the conformity to the directive.

3
NOMENCLATURE
Microscope body mount
Microscope body clamping knob
Reflected light intensity
control knob (Page 5)
Stage glass
# As this glass plate is dropped into the
position for use, take care not to drop it
(particularly during transport).
Reflected light (oblique)
LED illuminator (Page 5)
Tiltable
Focus adjustment knob (Page 5)
Power cord connector (Page 4)
Transmitted light intensity
control knob (Page 5)
Main switch (Page 4)
“ ” : ON
“ ” : OFF
Transmitted light LED illuminator (Page 5)
Equipped with a translucent plate.
Accessory mounting holes

SZ2-ILST
4
ASSEMBLY
1Mounting the Microscope Body (Fig. 1)
1. Loosen the microscope body clamping knob @.
2. Gently insert an applicable microscope body ² and tighten the
clamping knob.
2Setting Up the Power Supply (Figs. 2 & 3)
Cables and cords are vulnerable when bent or twisted. Never
subject them to excessive force.
Make sure that the main switch @ is set to “ ” (OFF) before
connecting the power cord.
Always use the power cord provided by Olympus. If no power cord
is provided, please select the proper power cord by referring to the
section “PROPER SELECTION OF THE POWER SUPPLY CORD” at
the end of this instruction manual.
1. Connect the connector ³ of the power cord to the power cord ² firmly.
Be sure to supply power from a grounded, 3-conductor power outlet
using the proper power cord. If the power outlet is not grounded
properly, Olympus can no longer warrant the electrical safety perfor-
mance of the equipment.
2. Connect the plug | of the power cord to the wall outlet ƒ.
Fig. 1
Fig. 2
Fig. 3
3
1
2
3
12
|ƒ

5
OPERATION
(Fig. 4)
1. Press the “ ” (ON) segment of the main switch @ to turn on the LED
illuminator.
The LED illuminator can be used in both transmitted and reflected light
illumination.
2. Turn the transmitted light intensity control knob ² and reflected light
intensity control knob ³ clockwise to increase the brightness.
Objectives and illumination performances
Auxiliary objective
Transmitted light
2
Adjusting the Reflected (Oblique) Illumination Angle
Hold the oblique light illuminator and adjust its angle so that the
illumination light hits the specimen.
3Adjusting the Focus Adjustment Knob Tension
Use the same procedure as the procedure for the standard stand, which
is described in the instruction manual for the microscope body.
Fig. 4
Lighting the Illuminator and Adjusting
the Light Intensity
1
3
1
2
Reflected light
110 AL 0.5X
110 AL 0.62X
110 AL 0.75X
110 AL 1.5X
110 AL 2X
Zoom 1.5X or more
*
Zoom1.2X or more
*
Zoom 1X or more
*
Zoom 1.2X or more
*
Any magnification available.
} When the TV light path of the SZ61TR is used with the image pickup CCD size of 2/3 in. or more, the light in the
peripheral area may be insufficient.
*Irregularities in illumination or insufficiency in the peripheral light may occur at lower magnifications than mentioned.
** This is because the illumination is obscured by the objective.
SZ2 series
Auxiliary objective
Transmitted light
Reflected light
DFPL 0.5X-4
DFPL 0.75X-4
DFPLAPO 1X-4
SZX-ACH 1.25X
DFPL 1.5X-4
Zoom 1.6X or more
*
Zoom 1.25X or more
*
Zoom 1.25X or more
*
Any magnification available.
SZX7
DFPL 2X-4
SZX-ACH 1X
Zoom 3.2X or more
*
Not available**
Zoom 1X or more
*

SZ2-ILST
6
SPECIFICATIONS
Item Specifications
Applicable microscopes SZ2 series microscopes (SZ51, SZ51-60, SZ61, SZ61-60 or SZ61TR) and SZX7
SZ series microscopes (Previous models)
Focus adjustment Focusing stroke 120 mm (85 mm up, 35 mm down)
Focus adjustment knob tension is adjustable.
Transmitted light illumination White LED (48 elements) illumination
Average LED life: 6000 hours*
Reflected light illumination White LED (30 elements) illumination
Average LED life: 6000 hours*
Dimensions & weight 226(W) x 237(H) x 318(D) mm. approx. 2.6 kg
Input rating 100-120 V/220-240 V , 0.15/0.1 A, 50/60 Hz
Operating environment · Indoor use
· Altitude: Max. 2000 m
· Ambient temperature: 5°C to 40°C (41°F to 104°F)
· Maximum relative humidity: 80% for temperatures up to 31°C (88°F), decreasing
linearly through 70% at 34°C (93°F), 60% at 37°C
(99°F), to 50% relative humidity at 40°C (104°F)
· Supply voltage fluctuations: ±10%
· Pollution degree: 2 (in accordance with IEC60664)
· Installation (overvoltage) category: II (in accordance with IEC60664)
*When the luminance is 50%.

7
PROPER SELECTION OF THE POWER SUPPLY CORD
If no power supply cord is provided, please select the proper power supply cord for the equipment by referring to “ Specifications ” and
“ Certified Cord ” below:
CAUTION: In case you use a non-approved power supply cord for Olympus products, Olympus can no longer warrant the
electrical safety of the equipment.
Specifications
Voltage Rating
Current Rating
Temperature Rating
Length
Fittings Configuration
125V AC (for 100-120V AC area) or, 250V AC (for 220-240V AC area)
6A minimum
60°C minimum
3.05 m maximum
Grounding type attachment plug cap. Opposite terminates in molded-on IEC con-
figuration appliance coupling.
Table 1 Certified Cord
A power supply cord should be certified by one of the agencies listed in Table 1 , or comprised of cordage marked with an
agency marking per Table 1 or marked per Table 2. The fittings are to be marked with at least one of agencies listed in
Table 1. In case you are unable to buy locally in your country the power supply cord which is approved by one of the
agencies mentioned in Table 1, please use replacements approved by any other equivalent and authorized agencies in
your country.
Country Agency Certification
Mark Country Agency Certification
Mark
Argentina
Australia
Austria
Belgium
Canada
Denmark
Finland
France
Germany
Ireland
IRAM
SAA
ÖVE
CEBEC
CSA
DEMKO
FEI
UTE
VDE
NSAI
Italy
Japan
Netherlands
Norway
Spain
Sweden
Switzerland
United
Kingdom
U.S.A.
IMQ
KEMA
NEMKO
AEE
SEMKO
SEV
ASTA
BSI
UL
JET, JQA, TÜV,
UL-APEX / MITI

SZ2-ILST
8
Table 2 HAR Flexible Cord
APPROVAL ORGANIZATIONS AND CORDAGE HARMONIZATION MARKING METHODS
Approval Organization
Printed or Embossed Harmoniza-
tion Marking (May be located on
jacket or insulation of internal wir-
ing)
Alternative Marking Utilizing
Black-Red-Yellow Thread (Length
of color section in mm)
Black Red Yellow
Comite Electrotechnique Belge
(CEBEC)
Verband Deutscher Elektrotechniker
(VDE) e.V. Prüfstelle
Union Technique de l´Electricite´
(UTE)
Instituto Italiano del Marchio di
Qualita´ (IMQ)
British Approvals Service for Electric
Cables (BASEC)
N.V. KEMA
SEMKO AB Svenska Elektriska
Materielkontrollanstalter
Österreichischer Verband für
Elektrotechnik (ÖVE)
Danmarks Elektriske Materialkontroll
(DEMKO)
National Standards Authority of Ireland
(NSAI)
Norges Elektriske Materiellkontroll
(NEMKO)
Asociacion Electrotecnica Y
Electronica Espanola (AEE)
Hellenic Organization for
Standardization (ELOT)
Instituto Portages da Qualidade
(IPQ)
Schweizerischer Elektro
Technischer Verein (SEV)
Elektriska Inspektoratet
CEBEC <HAR>
<VDE> <HAR>
USE <HAR>
IEMMEQU <HAR>
BASEC <HAR>
KEMA-KEUR <HAR>
SEMKO <HAR>
<ÖVE> <HAR>
<DEMKO> <HAR>
<NSAI> <HAR>
NEMKO <HAR>
<UNED> <HAR>
ELOT <HAR>
np <HAR>
SEV <HAR>
SETI <HAR>
10 30 10
30 10 10
30 10 30
10 30 50
10 10 30
10 30 30
10 10 50
30 10 50
30 10 30
30 30 50
10 10 70
30 10 70
30 30 70
10 10 90
10 30 90
10 30 90
Underwriters Laboratories Inc. (UL) SV, SVT, SJ or SJT, 3 X 18AWG
Canadian Standards Association (CSA) SV, SVT, SJ or SJT, 3 X 18AWG

AX6613 08
8F Olympus Tower, 446 Bongeunsa-ro, Gangnam-gu, Seoul, Korea 135-509
48 Woerd Avenue Waltham, MA 02453, U.S.A.
Distributed by
Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan
Manufactured by
REPEC
Table of contents
Other Olympus Rack & Stand manuals