Before using your air conditioner, please read
this manual carefully and keep it for future reference.
Read This Manual
Keep this manual where the operator can easily
find them.Inside you will find many helpful hints
on how to use and maintain your air conditioner
properly. Just a little preventative care on your
part can save you a great deal of time and money
over the life of your air conditioner. You'll find many
answers to common problems in the chart of
troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need
to call for service.
INVERTER SPLIT TYPE-
ROOM AIR CONDITIONER
ONNLINE N09ILE
N12ILE

1 2
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are
several possibilities:
A) The municipality has established collection systems, where electronic waste can
be disposed of at least free of charge to the user.
B) When buying a new product, the retailer will take back the old product at least
free of charge.
C) The manufacturer will take back the old appliance for disposal at least free of
charge to the user.
D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
Wild disposal of waste in forests and landscapes endangers your health when hazardous
substances leak into the ground-water and find their way into the food chain.
When using this air conditioner in the European countries, please read the following
information:
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
CONTENTS
SAFETY PRECAUTIONS
NAMES OF PARTS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
TROUBLESHOOTING TIPS
Warning .....................................................................................................................................3
Caution ......................................................................................................................................4
.
Indoor unit ........... .....................................................................................................................5
outdoor unit ...............................................................................................................................5
Indication lamp...........................................................................................................................5
Special functions .......................................................................................................................6
Operating temperature................................................................................................................7
Manual operation ......................................................................................................................7
Airflow direction control ............................................................................................................8
How the air conditioner works ..................................................................................................9
Before maintenance...... ...........................................................................................................10
Cleaning the unit.......................................................................................................................10
Cleaning the air filter and air freshening filter ..........................................................................10
Replacement of the air filter and air freshening filter ...............................................................11
Preparation for extended non-operation....................................................................................11
Pre-season inspection...............................................................................................................11
Normal function of the air conditioner.......................................................................................12
Troubleshooting guide .............................................................................................................14

34
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Be sure to follow the instructions.
Strictly prohibited.
CAUTION This symbol indicates the possibility of injury or damage to property.
Do not extend the cable and never use
multiple plugs. A poor electrical connection,
poor insulation or voltage which is higher
than permitted can cause fire.
Do not expose your body directly to the cool
air for prolonged period.
Never poke fingers, sticks or other objects
in the air inlet and outlet vents.
Never attempt to repair, relocate, modify the
air conditioner yourself. Always contact your
service partner if it requires.
Never pull the plug out by pulling on the
cable. Hold the plug firmly and pull it out of
the plug socket, otherwise there is a risk of
damaging the cable.
Do not operate your air conditioner in a wet
room such as a bathroom or laundry room.
Never actuate any switches with a wet
hand. It may cause an electric shock.
Never use the device for any other
purpose than the intended use. Never
place food, precision instruments, plants,
animals, paint, etc. on the unit.
Do not expose plants or animals directly
to the air flow.
Never clean the air conditioner with water.
Never use combustible cleaning agents
as these could cause a fire or deformation.
Never place any burning objects close to
the device if they could be directly affected
by the emitted air.
Never step onto the outdoor device and
never place anything on it.
Never use an unsteady or rusty base.
Never install the air conditioner in places
where combustible gas can be emitted.
Emmitted gas may collect and cause an
explosion.
Never allow the air conditioner to run for
too long with the doors or windows open,
or if the humidity is very high.
Remove all dirt from the power plug and
plug it firmly. Soiled plugs can cause fire
or an electric shock.
In the event of any abnormalities such
as smell of burning, immediately swithch
off the device and pull the plug. Contact
your service partner.
Always switch off the device and pull the
plug before you start to clean it.
Use specified power cord.
Contact the authorized installer for
installation of this unit.
Contact an authorized service technician
for repair or maintenance of this unit.
This appliance is not intended for use by
persons(including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the air
conditioner.
If the air conditioner is to be used in
conjunction with other heaters, the air
should be refreshed periodically, otherwise
there is a risk of lack of oxygen.
Always pull out the power plug if the unit
is not going to be used for any lengthy
period of time. Collections of dust can
cause fire.
Always switch off the air conditioner and
pull out the power plug during a storm.
Electrical parts may get damaged.
Check that the drainage line is correctly
connected. If not, water will escape.
Check that the condensation water can
run off unhindered. It may cause water
damage if the condensation water cannot
run off properly.
The air conditoner must be earthed in
accordance with the local codes.
For electrical safety purposes we
recommend that you install an earth-
leakage circuit-breaker.
If the power cord is damaged, it must be
replaced by the manufacturer, its service
agent or similary qualified persons in order
to avoid a hazard.
WARNING
CAUTION

56
OPERATING INSTRUCTIONS
8. Connecting
9. Connecting cable
10. Stop valve
pipe
Outdoor unit
Outdoor unit
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Signal receiver
Indoor unit
Indoor unit
Special functions
4
3
5
2
6
1
9
10
8
7
OPERATION indication lamp
This lamp illuminates when the air
conditioner is in operation.
ION indication lamp(optional function)
This lamp illuminates when Clean
Air feature is activated.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
Temperature indicator
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code.
NAMES OF PARTS
Indication lamp
Indication lamp
NOTE:
All the pictures in this manual are for
explanation purposes only. The actual shape
of the indoor unit you purchased may be slight
different on front panel and display window.The
actual shape shall prevail.
Names of parts
This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific
configuration of the model). With the anions generated by Ionizer, the air circulation of the air
conditioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collector
generates a high voltage ionization zone, through which the air is converted to plasma. Inside
the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter.
CLEAN AIR function(on some models)
Vertical swing function(Optional)
After the AC starts up, users can control the vertical louver swing by the remote controller.
SELF CLEAN function(Optional)
Function used after the Shut Down of cooling operation to clean the Evaporator
and keep it as fresh for the next operation.
The unit will operate as following sequence : FAN ONLY mode at Low fan speed--Heating
operation with LOW fan speed(applicable to cooling & heating modles only) ---FAN ONLY
operation--Stop Operation---Turn off.
Note:
This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode.
Before select the function, it is recommended to run the air conditioner under Cooling
operation for about half an hour. Once the Self Clean function is activated, all TIMER
setting will be cancelled.
During Self Clean operation, when press the SELF CLEAN button on the remote
controller again will stop the operation and turn off the unit automatically.
Louver Angle Memory Function(optional):
Within the scope of safety angle, it will memorize the open angle of horizontal louver.
If it exceeds, it will memorize the boundry of safety angle. In the following circumstances,
it will return to standard angle: 1) pressing the manual switch, 2)unplug and then plug
in the machine. So we strongly suggest that the open angle of the horizontal louver should
not be set too small, in case the condensed water forms and drops from the horizontal louver.
Refrigerant Leakage Detection
With this new technology, the dipsplay area will appear EC and the indication lamps
continue flashing when the outdoor unit detects refrigerant leakage.
,
,
Anti-mildew function(Optional)
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue
operating for about 7-10 minutes (depending on models) at LOW fan speed. If turns off on
HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed. This will
help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.

78
OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction properly otherwise it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal/vertical louver using the remote
controller. For some models, the vertical louver can
only be adjusted manually.
To set the horizontal/vertical air flow direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow direction.
The vertical/horizontal louver changes 6 degree in angle
for each press, or swing up and down automatically.
Please refer to the REMOTE CONTROLLER OPERATION
MANUAL for details.
For some models, the vertical louver can only be adjusted
manually. Move the deflector rod manually to adjust the air
flow in the direction you prefer.
IMPORTANT:Do not put your fingers into the panel of
blower and suction side.The high-speed fan inside may
cause danger.
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds,then restart
the air conditioner.
Do not operate unit with horizontal louver in closed
position.
CAUTION
,,
,,
OPERATING INSTRUCTIONS
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Deflector rod
Range
Range
Manual control button
Suspension bars
Manual control button
AU TO/COOL
AUTO/COOL
(1)
(2)
Manual operation
Operating temperature
Manual switch
Manual switch
Mode
Temperature
Room temperature
Outdoor temperature
1. Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection features
might come into operation and cause the unit to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over
80%) , condensed water may drip out of the unit. Please sets the vertical air flow louver to
its maximum angle (vertically to the floor), and set HIGH fan mode.
Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature
O O
is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to
guarantee it running smoothly.
NOTE:
Cooling operation Heating operation Drying operation
-15 50 5 122
For the models with low
temperature cooling system
0 50
32 122 -15 30
5 86
0 50
32 122
Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
For some models, please use suspension
bars to prop up the panel.
lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original
position.
One press of the manual control switch will
This switch is used for testing purposes
only. You had better not choose it.
To restore the remote controller operation,
use the remote controller directly.
CAUTION:
1
3
2
●
●
NOTE: The unit must be turned off before
operating the manual control button. If the
unit is operational, continue pressing the
manual control button until the unit is off.
O O
17 C~32 C
O O
(62 F~90 F)
O O
0 C~30 C
O O
(32 F~86 F)
O O
10 C~32 C
O O
(50 F~90 F)
Units are equipped with a switch to run emergency operation mode. It can be accessed by
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.
This manual suits for next models
1
Table of contents
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual