Read this manual carefully before you mount or use the remote control.
Package contents
1x 15RF Remote control manual.
1x Remote control.
1x Wall frame (mounted on the back of the remote control).
1x CR 2032 battery
2x 3.5x32 mm screws
2x 6 mm plugs
Introduction / Why RF
This remote control (B) was especially developed for the MVS-RH, MPV-WR and
HRC-BRH units. Radio Frequency (RF) control means that the ventilation device can be
switched remotely and wirelessly by one or several remote controls, up to a maximum
of 20. During renovation in particular, providing wiring is often difcult and expensive,
which makes this wireless switching method ideal. The RF control signal is received
by a receiver printed circuit board (PCB) mounted in the device. The remote control
has 6 buttons for selecting the required position or mode: absent, low, medium, high,
automatic and timer.
The remote control is intended for exclusive use with Orcon ventilation units from the
15 series. If bought separately, the remote control must be connected for the rst time
to the Orcon ventilation unit by the installer.
Mounting 15RF Remote control
The remote control can be opened via the push button (see gures 2 and 3), which
is located on the underside. The wall frame can then either be mounted with the
2 supplied screws and plugs or be stuck in place. Please note: ‘UP’ is marked on the
wall frame, when mounting make sure that this is at the top. Keep enough space free
around the underside so that the push button can be easily reached from below. It is
recommended that the remote control is installed in the living room, kitchen or lavatory
at a height of 1.5 m. Never install the remote control near large metal objects, and keep
the remote control out of the reach of children.
Device start up
When the device is connected to the voltage supply: during start up, the LED on the
receiver PCB in the unit (gure 1) ashes alternately red, green, red. Then the LED on
the receiver PCB turns green for 3 minutes, during which time the device is in learning
mode and can be linked to a remote control or CO2sensor.
Pairing remote control(s) to 1 device
Remove the plug of the device from the power point for 30 seconds. Then reinsert the
plug in the power point. The LED on the receiver PCB (gure 1) ashes alternately red
and green, after which the LED remains green. The device will be in learning mode for
3 minutes. During this time, you can pair remote control(s) by pressing the buttons
<1> and <auto> simultaneously until the LED on the remote control ashes alternately
red, green, red. When the remote control has been successfully paired, the LED on the
receiver PCB and remote control will ash green 10 times, and the device will briey
accelerate. The remote control is now ready for use.
Alternative pairing procedure:
Remove the cover from the device. Briey press the push button of the receiver PCB
once (gure 1). The LED on the receiver PCB (gure 3) ashes alternately red and green,
after which the LED remains green. The device remains in learning mode for 3 minutes.
Pairing the remote control is carried out in the same way as described in the pairing
procedure above. Pairing an additional remote control is carried out in the same way as
pairing remote control number 1.
Pairing remote control(s) to several devices
To pair 1 remote control to several devices, the pairing procedure above is repeated
except that buttons <2> and <auto> are simultaneously pressed for 3 seconds to pair
the remote control. To replace a remote control, all the components must be unpaired
on the receiver PCB. Afterwards, all the components must be once again paired.
Timer mode
In the timer mode, the device operates in the high position for the required time, after
which the device returns to the last selected position. Pressing once causes the device
to operate in the high position for 15 minutes, pressing twice 30 minutes, and pressing
three times 60 minutes. The timer can be cancelled by selecting another button.
Auto mode
In auto mode the device operates in accordance with signals from the integrated
moisture sensor and/or the optional 15RF CO2sensor.
Absence position
In the absence position the device runs in an extra energy-efcient low position and
does not respond to signals from sensors.
Service and maintenance
Battery replacement
If the LED indication on the remote control ashes orange once, or does not react when
you operate one of the control buttons, the cause is probably a low battery. You do
not need to contact your installer to replace this battery. It is a task you can easily do
yourself. The battery can be ordered from www.orcon.nl. To replace the battery, click in
the push button on the wall frame (gure 3) of the remote control in order to remove
the upper part of the wall frame of the remote control. Remove the old battery from
the remote control. Insert the new battery with the positive side facing you (see gure
4). Replace the protective cover and click the upper side shut on the wall frame with
a hinge movement. In normal use, a new battery has a service life of about 6 years.
Please note: Do not throw batteries away with household waste,
instead take them to a collection point for chemical waste.
Unpairing remote control(s) and sensor(s) on the device
Remove the cover from the device. Press the push button on the receiver PCB in the
device (gure 1) for 15 seconds until the LED is simultaneously red and green (orange).
Release the push button. After release, the LED on the receiver PCB ashes alternately
red, green, red. Any connections with the remote control(s) / CO2sensor(s) are now
deleted and the factory settings are loaded. The LED on the receiver PCB remains green
for 3 minutes, during which time the device is in learning mode and can be linked to
a remote control or CO2sensor.
Reset remote control
A remote control can be reset by pressing the ‹absent› and ‹timer› buttons simultane-
ously for 3 seconds. The remote control indicates that the reset is complete by ashing
orange twice.
Service
The remote control is extensively tested in the factory. Have you nevertheless encoun-
tered a problem? Then please ask your installer to contact Orcon’s service department.
Guarantee
The factory guarantees this device in accordance with the conditions listed in the
general terms and conditions.

Technical data
Power supply 3 V battery
Dimensions 83 x 80 x 28 mm
Weight 125 g
RF frequency 868.3 MHz
Min/Max Ambient temperature 0-40 °C
RH level 0-90 %non-condensing
Protection class IP30
List of 15RF remote control indications
Indication Notication on remote control
Device OK, message followed
Device OK, timer activated 15 min.
Device OK, timer activated 30 min.
Device OK, timer activated 60 min.
RF communication problem
Understood, but problem in device
Learning mode is being initiated
Successful connection with device
Low battery
Remote control reset carried out
15RF Remote control user interface explanation
Button Control Function
1x short Absence mode
1 1x short Position 1 (low position)
2 1x short Position 2 (medium position)
3 1x short Position 3 (high position)
1x short Position 3 (timer mode) temporary 15 minutes
2x short Position 3 (timer mode) temporary 30 minutes
3x short Position 3 (timer mode) temporary 60 minutes
auto 1x short Automatic mode
When a button is pressed on the remote control, the LED turns green, after which it
ashes to conrm. The following indications are possible:
Fig. 1 - Receiver PCB in the device
Fig. 3 - Back of remote control
Fig. 4 - Battery in remote control
Fig. 2 - Exploded view remote control
Upper part
Push button to open control
Battery position
Wall frame
= Green = Red = Orange
Declaration of conformity
Orcon BV declares that this remote control conforms with the
Machinery Directive (2006/42/EC), the Low Voltage Directive
(2006/95/EC), the EMC Directive (2004/108/EC), the RoHS
Directive (2002/95/EC) and the R&TTE Directive (1999/5/EC).
Veenendaal, NL
M. Voorhoeve, General Manager
!
Push button
Red/green LED
Push button to open control
Landjuweel 25, 3905 PE Veenendaal, NL
PO Box 416, 3900 AK Veenendaal, NL
tel. +31 (0)318 544700
fax +31 (0)318 544706
info@orcon.nl
www.orcon.nl