CAUTION
Install the indoor unit housing securely.
If the indoor unit housing is not installed securely, it
could fall and cause personal injury.
Note: Install the indoor unit housing with the front panel closed.
FRONT PANEL REMOVAL AND INSTALLATION
REMOVING THE INDOOR UNIT HOUSING
(1) Remove the two screw caps, and then remove the two lower tapping screws.
(2) Open the front panel, and then remove the front cover.
(3) Remove the four upper tapping screws.
(Note: One tapping screw is located behind the front cover.)
(4) Unhook the indoor unit housing from the center projection and remove.
INSTALLING THE INDOOR UNIT HOUSING
(1) Insert the six tabs on the indoor unit housing into the indoor unit.
(2) Hook the indoor unit housing onto the center projection.
(3) Install the six tapping screws (both upper and lower), and then install the
screw caps.
(4) Install the front cover with the screw.
TEST RUNNING
●Perform test operation and check items 1 and 2 below.
●For the test operation method, refer to the operating manual.
●The outdoor unit, may not operate, depending on the room temperature. In this case, press
the test run button on the remote control unit while the air conditioner is running, (Point the
transmitter section of the remote control unit toward the air conditioner and press the test
run button with the tip of a ball-point pen, etc.)
●To end test operation, press the remote control unit START/STOP button.
(When the air conditioner is run by pressing the test run button, the OPERATION indicator
lamp and TIMER indicator lamp will simultaneously flash slowly.)
1. INDOOR UNIT
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do the air flow-direction louver operate normally?
(4) Is the drain normal?
2. OUTDOOR UNIT
(1) Is there any abnormal noise and vibration during operation?
(2) Will noise, wind, or drain water from the unit disturb the
neighbors?
(3) Is there any gas leakage?
Transmitter section
Fig. 17
Be sure that the top hole of the front
panel is hooked securely to the hook
of the base.
Explain the following to the customer in
accordance with the operating manual:
(1)
Starting and stopping method, operation
switching, temperature adjustment,
timer, air flow switching, and other
remote control unit operations.
(2)
Dustbox filter, air filter and top grill
removal and cleaning, and how to use
the air louvers.
(3)
Give the operating and installation
manuals to the customer.
CUSTOMER GUIDANCE
CAUTION
Install the front panel and intake
grille securely. If installation is
imperfect, the front panel or intake
grille may fall off and cause injury.
Fig. 20
POWER
Test run button
WARNING
(1) The rated voltage of this product is 230 V AC 50 Hz.
(2) Before turning on the power, check if the voltage is within
the 220 V -10 % to 240 V +10 % range.
(3) Always use a special branch circuit and install a special
receptacle to supply power to the room air conditioner.
(4) Use a circuit breaker and receptacle matched to the
capacity of the air conditioner.
(5) Do not extend the power cord.
(6) Perform wiring work in accordance with standards so that
the air conditioner can be operated safely and positively.
(7) Install a leakage circuit breaker in accordance with the
related laws and regulations and electric company
standards.
CAUTION
(1) The power source capacity must be the sum of the air conditioner
current and the current of other electrical appliances. When the
current contracted capacity is insufficient, change the contracted
capacity.
(2) When the voltage is low and the air conditioner is difficult to start,
contact the power company the voltage raised.
NOTE: These equipment shall be connected to a suitable mains network with a
main impedance less than the following: 1. 257
Ω
The product is intended for use only in premises having a service current
capacity 100A per phase,supplied from a distribution network having a
nominal voltage of 230 V, and instruct the user to determine in consulation
with the supply authority, if necessary, that the service current capacity at
the interface point is sufficient for the equipment.
REMOVING THE DUST BOXES
(1) Open the two latches on the ends of each dust box.
(2) Remove the dust boxes with the air filters attached.
INSTALLING THE DUST BOXES
(1) Install the dust boxes with the air filters attached.
(2) Close the two latches on the ends of each dust box.
(The latches will "click" when they are closed.)
Indoor unit
housing
Lower tapping
screws
Screw caps
Upper tapping screws
Screw
Front cover
Center
projection
Indoor unit
housing
Indoor unit
housing
Intake grille
Tabs
Latches Latches
Air filter
Dust box