Orisec WIFI-2 Installation guide

WIFI-2 Module & ControlPlus App
Installation and Programming Guide
Designed and Manufactured
in the United Kingdom
www.orisec.co.uk

2
Contents
1. Introduction ...........................................................................................................................3
2. Installation..............................................................................................................................3
3. Programming the WIFI-2 Module....................................................................................5
4. Wi-Fi status for the WIFI-2 Module.................................................................................6
5. ControlPlus setup for iOS & Android ..............................................................................7
6. Specifications.........................................................................................................................8
7. Standards................................................................................................................................9
EMC .................................................................................................................................................. 9
Warranty.......................................................................................................................................... 9

3
1. Introduction
The WIFI-2 Module is fully compatible with the W-CP-40K, W-CP-40T and W-CP-40E control
panels.
The control panels must be version 1.05 onwards.
The WIFI-2 Module provides local and remote connections for the Orisec UDL, Apps and Web
Browser Sessions via the internet.
2. Installation
1. Connect the WIFI-2 module to the reverse of the W-CP-40 control panel as shown below.
IMPORTANT:
The W-CP-40 must NOT be powered when connecting or removing the WIFI-2 Module.

4
2. Connect the Wi-Fi antenna.
Peel off the self-adhesive backing and stick the PCB antenna to the bottom left-hand side of
the enclosure as shown below.
Carefully connect the antenna cable to the WIFI-2 Module antenna socket.

5
3. Programming the WIFI-2 Module
Scanning available networks
1. Enter engineers code
2. Tests & Diagnostics - press E or R arrow to enter the menu.
3. Navigate to ‘WIFI status & checks’ (option 7) and press E or R arrow to enter the
menu.
4. Press C to scan for available networks, select the desired network and press E.
This will insert the SSID (Service Set Identifier) into the WIFI setup menu.
Example screen:
5. Navigate back to ‘Programming menu’- press E or R arrow to enter the menu.
6. Navigate to ‘Coms Modules’ (option 14) and press E or R arrow to enter the menu.
7. Scroll down to ‘WIFI settings’ press E or R arrow to enter the menu.
8. Enter the following information:
SSID = Enter the router’s SSID (if scanned previously this will already be populated)
Password = The password for the router
The additional settings (below) are only required if DHCP is not being used.
Address = Local IP address for the network (i.e. 192.168.1.75)
Port = Port number for the Orisec WIFI-2 Module (i.e. 10006)
Mask = Subnet mask for the internal network (i.e. 255.255.255.0)
Gateway = Gateway address for the internal network (i.e. 192.168.1.1)

6
Example screen:
4. Wi-Fi status for the WIFI-2 Module
1. Navigate to ‘Tests & diagnostics’- press E or R arrow to enter the menu.
2. Navigate to ‘View module status’ (option 6) and press E or R arrow to enter the
menu.
3. Scroll across to ‘WIFI’ status. The screen will show one of the following:
Status: Not fitted
Status: Initialising
Status: Ready
Status: In Fault
Not fitted
The WIFI-2 Module is not fitted or not being seen by the W-CP-40, check the physical
connection.
Initialising
The WIFI-2 Module is in the initialising stage, once configuration has been saved this will change
to ‘Ready’.
Ready
The WIFI-2 Module is Ready for use with the Orisec UDL, Orisec Apps and Orisec web Browser.
In Fault
The WIFI-2 Module is in fault, check to ensure all settings are correct and the aerial is not
damaged.

7
5. ControlPlus setup for iOS & Android
1. Open the ControlPlus Application on the Smart Device.
2. Select the COG on the bottom right.
3. On initial setup, a new site will need to be added, simply select ‘+ Add new site’
4. Fill in the following information:
a. *App Password –An app password can be utilised to require a log in code
prior to using the app.
b. Site –Unique identifier for the site i.e. My House
c. User Code –Enter a valid user code for the control panel.
d. Use Cloud –Enable this option to create a connection via the Orisec
Cloud.
e. *Authorisation –An authorisation code can be assigned as an extra level
of security.
f. Serial # - The serial number of the control panel (Required for Cloud
Connections)
g. Notifications –Enable this option to receive notifications from the app.
h. Enable Omit –Enable this option to have the ability to omit zones.
5. Once complete, press the COG on the bottom right to return to the connect screen.
*Optional feature
The serial number is acquired from the control panel in the following location:
Engineers code > ‘About’
*For additional information on Control Plus please refer to INS079 ‘Control Plus User App’.

8
6. Specifications
Electrical
Operating Voltage:
10 –15Vdc
Current Consumption:
Receive Mode: 110mA, Transmit Mode: 290mA
Environmental
Operating Temperature:
-10°C to +55°C
Storage Temperature:
-20°C to +60°C
Max. Humidity:
95% non-condensing
EMC:
Residential, Commercial, Light Industrial & Industrial
Physical
Dimensions:
HxWxD: 76mm x 100mm x 17.5mm
Packed Weight:
140g

9
7. Standards
EMC
Conforms to European Union (EU) Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU
and EN 50130-4:2011+A1:2014
EMC Environment: Residential / Commercial / Light Industrial / Industrial
CE: You can view the product EC Declaration of Conformity here:
www.orisec.co.uk/compliance
WEEE Directive: 2012/19/EU Compliant: This symbol indicates that according to local
laws and regulations, this product should not be disposed of as municipal/household
waste. Instead, it should be disposed of at the appropriate collection points designated
for the recycling of electrical and electronic equipment, or returned to Orisec upon
purchase of new replacement products. This will help to conserve natural resources
and ensure that it is recycled in a manner that protects human health and the
environment.
RoHS Directive: 2011/65/EU Compliant:
Orisec declares that this product complies with and conforms to RoHS legislation that it
does not contain more than the agreed levels of: Lead (Pb), Cadmium (Cd), Mercury
(Hg), Hexavalent chromium (Cr6+), Polybrominated biphenyls (PBB), Polybrominated
diphenyl ethers (PBDE)
Manufacturer: Orisec Ltd, 1 St Crispin Way, Haslingden, Lancashire. BB4 4PW. United Kingdom.
Warranty
The WIFI-2 Module is guaranteed against defects in material or faulty workmanship for a period
of 2 years from the date of purchase.
Disclaimer: Orisec will not accept any liability based on a claim that the WIFI-2 Module failed
to perform correctly as it is a component part of an installation and not a complete intruder
alarm system.

10
Notes

11
Notes
Table of contents