Panasonic EP-MA50 User manual

Operating Instructions
Household Massage Lounger
English 1
Français F1
Mode d’emploi
Fauteuil vibromasseur
Model No./Nº de modèle
EP-MA50
Before operating this unit, please read these instructions completely.
Avant d’utiliser cet appareil, nous vous recommandons de lire l’ensemble
de ces instructions et de les ranger dans un endroit accessible pour une
consultation ultérieure.

1
English
IMPORTANT SAFETY INSTRUCTIONS
Basic precautions should always be followed when using an electrical unit, including the following.
Please ensure that you read all instructions before using the Household Massage Lounger.
DANGER– To reduce the risk of electric shock:
1. Always unplug this unit from the electrical outlet immediately after using and before cleaning.
WARNING– To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Always insert the power plug all the way into the outlet to reduce the risk of short-circuit and fire.
2. The unit should never be left unattended when plugged in. Always unplug the unit when not in use.
3. The unit is not to be used by people who cannot move or communicate on their own.
4. Only use the unit for the purpose described in these instructions.
5. Do not stand on the unit.
6. Do not use any accessories other than those recommended by the manufacturer.
7. Always return the seat to the upright position and make sure the legrest is completely retracted.Be careful that
nothing is obstructing the legrest while retracting. Keep children away from the legrest.
8. Never operate the unit if it has a damaged power cord or plug. Return the unit to the nearest authorized service
center if it is not working properly, if it has been dropped or damaged, or if it has been immersed in water.
9. Keep power cords away from heated surfaces. Do not carry the unit by the power cord.
10. Never block the air openings during operation and make sure that all air openings are kept free of lint and hair,
etc. Do not drop or insert anything into any of the openings of the unit.
11. Do not use the unit on top of heating appliances, such as electric carpets, etc.Do not operate the unit under
blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons.
12. Do not use the unit in bathrooms or other damp or humid places as this may cause electric shock or cause the
unit to malfunction. Do not spill water, etc. onto the controller.
13. Do not use the unit outdoors.
14. Do not use or operate where aerosol spray products are being used or where oxygen is being administered.
15. When unplugging the unit, turn off all controls before removing the plug from power outlet.Do not use the unit
with a transformer as this may lead to malfunction or electric shock.
16. Connect this unit to a properly grounded outlet only.See Grounding Instructions.
SAVETHESE INSTRUCTIONS

2
English
SAFETY PRECAUTIONS
CAUTION:To avoid the risk of injury:
1. Persons with any of the conditions listed below or who are undergoing medical treatment or suffer from medical
conditions should consult with their physicians before using the unit:
a) Pregnant women, people who are ill, in poor physical shape.
b) People suffering from back, neck, shoulder, or hip pain.
c) People who have a pacemaker, defibrillator, or other personal medical devices prone to electronic
interference.
d) People suffering from heart disease.
e) People who are prohibited from receiving massage by a physician due to thrombosis or aneurism, acute
varicose veins, or other circulatory disorders.
f) People with irregular curvatures of the spine.
2. This unit should not be used by children.Remove the key when not in use and store out of reach of children.
3. Sit down slowly after checking the position of the massage heads. Never put any part of your body between the
massage heads as the squeezing action of the massage heads may cause injury.Never put your fingers or feet
in the gap between the backrest and seat, the backrest and the armrest, the seat and cover under the armrest,
or the gap between the legrest and the footrest. Do not place your fingers or any part of your body in the
mechanism below the legrest, or between the legrest and footrest.
4. Do not use the unit against bare skin.While thin clothing may increase effectiveness, exposing the skin directly
to the massager may irritate the skin.
Do not use the unit while wearing anything hard on your head like a hair accessory, etc.Do not use the unit for
massaging the head, abdomen, front neck, elbows or knees.
Do not use excessively strong massage action on the back of the neck.
5. When using the body scanning function, always ensure that the shoulder position is correct. If the shoulder
position is not correct, use the POSITION button to adjust it properly.Or stop the massage function and re-try
the body scanning function.You can adjust the shoulder position in this way in the auto program and manual
operation.Failure to align the shoulder position correctly can lead to injury.
6. Do not stretch the back muscles for more than approximately 15 minutes at a time.To avoid overstretching the
muscles which may result in discomfort, do not use the unit for more than 5 minutes when first using it.You can
gradually increase the duration and strength of the massage as you become used to it.
Do not massage any one point for more than 5 minutes at a time.
Excessive massaging can overstimulate the muscles and nerves and result in an adverse effect.
To prevent excessive massaging, do not use the massager for more than a total of 15 minutes each session.
After approximately 15 minutes, the massage heads will be retracted and stop moving.
The back cushion can be removed if you want to experience a stronger back massage. Exercise extreme care
when you use this mode in order to avoid back pain or injury.Use only for short periods of time (no more than
15 minutes).Reinstall the back cushion if you want to restore to normal massage intensity.
7. While using the massager, if you start feeling sick or if the massage seems painful, stop using it immediately.
While using the massager, if the pressure seems too strong, the movement of the massage heads can be
stopped at any time by pressing the Quick Stop button.
8. Do not go to sleep while using the unit. Do not use the unit after drinking alcohol.
9. When the seat back is in a reclined position, do not sit on it or sit with your legs resting on the headrest.
Do not sit on the legrest as the unit may fall over.
10. Do not allow children or pets to play on or around the unit, especially during operation.
11. Do not unplug the unit or turn it off during operation. Unplug the unit immediately if there is a power outage.
12. Be sure to start on the gentle massage program if using the massager for the first time.The shiatsu massage is
stronger and should be enjoyed after one has gotten accustomed to the chair.
13. Do not allow children to play on this mechanized furniture or operate the mechanism. Legrest folds down on
closing so that a child could possibly be injured.Always leave in an upright and closed position. Keep hands
and feet clear of mechanism. Only the occupant should operate it.
14. Remove hard objects, such as false fingernails, wristwatches or rings, when massaging hands or arms.
Empty pockets of hard objects when massaging the area of the seat or thighs.

3
English
15. Always raise the back cushion to check that the fabric of the unit itself has not been ripped before using the unit.
Please also check other areas to ensure that the fabric has not been ripped. No matter how small the rip, if you
find one then immediately stop using the unit, unplug the power cord and have the unit repaired at an
authorized service center.
16. People with any of the conditions listed below should not use the Stretch program:
1) People suffering from acute lumbago, spinal disc herniation, or misalignment of the vertebrae
2) People with hip joint problems such as hip osteoarthritis
3) People with osteoporosis
4) People who felt numbness or listlessness in the legs
It may worsen the symptoms.
17. Sit on the unit after confirming there is no foreign matter between the parts of the unit. (Confirm that there are
no foreign objects stuck in the back cushion, leg/sole massage section, hand/arm massage section, or under
the seat.)
Failure to observe this precaution may result in accident or injury.
18. Always return the legrest to its original position before moving the unit.
Failure to observe this precaution may result in injury due to the legrest returning to its original position when
the unit is being moved.
19. Do not leave the removed attachment screws lying unattended.
Accidental ingestion may occur.
20. Do not stand, jump on, or place objects on the seat until the air is completely extracted for the Stretch program.
OPERATING PRECAUTIONS
CAUTION:To avoid damaging the chair, follow these precautions:
1 The chair is designed for a maximum user weight of 264 lbs (120 kg).Exceeding the maximum weight may
cause permanent damage to the massage mechanism and/or other components of the unit. Any such damage
is deemed to be user abuse and is not covered under the Limited Warranty.
2. Do not sit on or drop the controller. Do not pull the controller cord or the power cord. Be careful not to catch the
cord of the controller between the armrest and the chair back.
3. Do not treat the chair roughly, such as turning the chair on its side, turning the chair over or standing on it.
4. Do not treat the covering roughly.
Keep sharp or pointed objects away from the covering of the chair. Be careful not to drop lit ashes, lit cigarettes
or matches on the chair.
Exposure to direct sunlight can cause fading or a change in color of the covering.
5. If the massager functions abnormally, immediately turn off the power and have the massager checked by an
authorized service center.
6. Do not repeatedly operate any switch at short intervals. Such action may cause the switch to malfunction.
7. Some noise may be heard coming from the massager while in use.This is due to the structure of the massager
and is normal.
8. Make sure there are no obstacles behind the chair before reclining it.The chair can be reclined to a maximum
angle of 170˚. If the back hits a wall or pillar, the chair may malfunction.Be sure to have ample space behind
the chair. Recline the chair slowly in order to avoid contact with an obstacle.
9. When excessive pressure is applied to the massage heads, they may stop moving for safety.When moving the
heads up from the lowered position, one’s body weight may stop the heads’ movement. In such a case, slightly
raise your body and allow the massage heads to move up.
10. After each massage, slide the power switch, which is located on the right side of the chair, to the “off” position
and turn its lock switch to the “lock” position.
11. Do not sit on the chair with wet body or hair.
12. The unit must not be used in “wet rooms” (sauna, swimming pool) or outdoors.
13. Do not attempt to open or disassemble any part of the unit. Only use an authorized Panasonic servicer to fix
your unit.
•
•

4
English
SPECIFICATIONS
Power Supply: AC 120 V 60 Hz
Rated Current: 1.6 A
Upper Body Massage
Massage area (Up-Down): Approx. 28.7 in. (73 cm) [The massage heads move a total of approx.24.4 in. (62 cm)]
Massage area (Left-Right): Distance between massage heads during operation (massage width adjustable)
Neck, Shoulder, Back, Lower back: Approx. 2 in. – 8.3 in. (5 cm – 21 cm)
Massage area (Forward-Back): Projected amount of massage head (Intensity adjustable)
Approx. 4 in. (10 cm)
Massage speed: Tap: Approx. 250 cycles/minute – 450 cycles/minute (single side)
Full roll: Approx.33 seconds – 84 seconds (both ways)
Other than the above: approx. 5 cycles/minute – 50 cycles/minute
Vertical travel: Vertical travel (Long): Approx. 28.7 in. (73 cm) up-down auto return
Massage width: Full roll, Vertical Movement: Approx. 2 in. – 6.7 in. (5 cm – 17 cm)
Other than the above: Same as massage area (left-right)
Air massage
Air Pressure (Calf): 5: Approx. 36 kPa
4: Approx. 35 kPa
3: Approx. 34 kPa
2: Approx. 26 kPa
1: Approx. 17 kPa
* It may vary with the area slightly.
Reclining angle: Backrest: Approx 120° – 170°
Legrest: Approx 0° – 85°
Automatic shut-off: Automatically turns off after approx. 15 minutes
Dimensions
When not reclined (H × W × D):
When reclined (H × W × D): Approx. 46.1 in. × 32.2 in. × 49.6 in. (117 cm × 82 cm × 126 cm)
Approx. 24.2 in. × 32.2 in. × 76.8 in. (62 cm × 82 cm × 195 cm)
Weight of Unit: Approx. 168 lbs (76 kg)
Dimension of box (H × W × D): Approx. 28.3 in. × 30.7 in. × 65.4 in. (72 cm × 78 cm × 166 cm)
Weight in box: Approx. 201 lbs (91 kg)
Maximum user weight: Approx. 264 lbs (120 kg)
Minimum distance from wall: 16 in. (40 cm)
GROUNDING INSTRUCTIONS
This product must be grounded.If it should malfunction or break down, grounding provides a path of least resistance for electric
current to reduce the risk of electric shock.This product is equipped with a cord having an equipment-grounding conductor and
a grounding plug.The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with
all local codes and ordinances.
DANGER
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified
electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided
with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120-volt circuit and has a grounding plug that looks like the plug illustrated in Figure A.
Make sure that the product is connected to an outlet having the same configuration as the plug.
No adapter should be used with this product.
Figure A
GROUNDED
OUTLET
GROUNDED
OUTLET BOX
GROUNDING PIN

5
English
Part names and functions
Main unit
9
1
3
4
6
2
7
10
5
8
Front
9Legrest
10
Legrest Slide Lever
Extendable length to approx.
4.7 in. (12 cm).
•
1Retracted position of massage
heads
2Pillow
3Back Cushion
4Backrest
Includes integrated massage
heads.
Air bag for Stretch program is
built in.
5Hand/Arm massage section
Includes integrated air massage
function.
6Armrest
•
•
•
7Seat
Air bag for Stretch program is
built in.
8Leg/Sole massage section
Includes air massage function.
Sole Reflexology Plates
“Creepers” are provided on the
back side.
Fine adjustment of position
possible.
Removable.
•
•
•
•
•

6
English
11 12
13
18
14
16
15
19
17
Back
16
Power Cord
17
Power plug
18
Safety Precaution Label
19
Leg cover
11
Back Cover
12
Controller tray
13
Controller
See page 7 to 8.
14
Child Safety Decal
15
Power Supply Box
Lock Switch
Power Switch
Lock Switch Key
Lock Switch KeyTag
For preventing children from swallowing it by
accident.
•
Lock switch is set to “open” and power switch is set to “on” prior to leaving
the factory.
•
•

7
English
Controller
Cover closed
8
7
9
10
11
12
13
14
15
2
3
4
1
5
6
Cover open
1Off/On button
2Program Selection buttons
See page 17.
3Massage intensity adjustment
dial
Intensity of the massage
(pressure of the massage heads
pressing onto the body) can be
adjusted.
Intensity of the Stretch program
can be adjusted.
4Region Off/On button
See page 19.
5User Memory Registration
button
See page 21.
6Manual Operation Selection
button
See page 27.
7Display
This illustration is when all lamps
are illuminated.
See page 8.
8Quick Stop button
Press this button to stop the
massage immediately.
9Stretch Program Selection
button
See page 23.
10
Reclining Angle Adjustment
button
See page 32.
11
Ottoman Angle Adjustment
button
See page 32.
12
Air Massage button
See pages 20, 27 and 28.
13
AddTap button
See page 27.
14
Leg Stretch Off/On button
See pages 20, 27 and 28.
15
Position button
See page 27.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

8
English
Display
15
4
3
2
4Massage Area Display
Current general massage area
will flash.
5Body Detection Notification
Display
This will light up when the body
scanning is completed.
•
•
1Time Remaining Display
(During massage)
(After finishing massage)
2Massage Intensity Display
Current massage intensities
(pressure of the massage heads
pressing onto the body) for each
region are displayed in 8 steps.
•
3Operation Display
Current massage operation is
displayed while massaging.
Currently selected operation is
displayed when Manual
Operation is selected.
FULL ROLL
ULTRA KNEAD
SHIATSU
KNEAD
SWEDISH
TAP
•
•

9
English
Setting up the massage lounger
1Where to use the unit
Ensure there is adequate space to recline.
Do not expose the massage lounger to direct sunlight or high
temperatures, such as in front of heating sources, because this can
cause discoloration or hardening of the synthetic leather.
Place the unit on a mat to prevent floor damage.
When placing a mat under the unit, the size of the mat should be
sufficient [at least 47.2 in. × 27.6 in. (120 cm × 70 cm)] to cover the
areas where the unit touches and where the legrest could touch the
floor, as shown in the diagram on the right.
Install the unit near a power outlet.
See Warning No. 11 and 12 on page 1.
•
•
•
•
•
Keep at least 4" (10 cm) away from the wall.
Approx. 77" (195 cm)
Width approx. 32" (82 cm) Approx. 13"
(32 cm)
Approx. 15"
(37 cm)
Mat Area where legrest
could touch the floor Area where unit
touches the floor
2 Removing everything from the box and installing the unit
Fabric Section Groove
Hold the cloth
section on the
backside
MatLegrest Back cover
Place your
fingers in the
groove
Since the unit is very heavy [approximately 168 lbs
(76 kg)], be careful to avoid back injuries. (The unit
must be carried by two persons.)
When using the wheels to move the unit, place a mat
on the floor to protect the floor surface.
To put the unit down on the floor
Put the unit down slowly and carefully watch your step.
Put down the legrest by holding it with your hands until
it has been set on the floor completely.If you release
your hands before the legrest is fully extended, the
legrest will forcefully return to the initial position.
•
•
•
•

10
English
Confirm that the main unit and the accessories are in the box.
Main unit
Controller
Accessories
Armrests (Right/Left)
Right/Left
indication
Air plug
Small holes on the inside fabric are an
intentional part of the functional design.
•
Back Cushion Pillow
Sole Reflexology Plates
This is installed on the
sole massage section prior
to leaving the factory.
•
ControllerTray Attachment Screw Cap
2 pcs. Attachment Screws
(M6 × 16) 4 pcs. Allen Key
(Cross-section)
1/6 in.
(4 mm)
Lock Switch Key
This is initially inserted in the lock switch of the
power supply box prior to leaving the factory.
•
Documents including the Operating Instructions
Operating Instructions
Child Safety Instructions (Yellow brochure)
How to Carry in and Assemble (Yellow brochure)
Notes for Body Scanning (Pink brochure)
Quick Start Manual
•
•
•
•
•

11
English
Assembly
1 Attaching the armrests (On both the right and left sides)
1Insert the armrest into the
unit.
Be careful to avoid pinching your fingers.
1Align the position.
2Fit in the grooves and protrusions in
the front and back of the unit and
armrest simultaneously.
•
Groove
Armrest
Main unit
Protrusion
Right/Left indication
Groove
Protrusion
Front Back
2Fasten the armrest with the attachment screws. (4 positions)
How to tighten the screws
Attachment
screw
Hole
Allen key
Tighten loosely with your finger.
(Make the screws level with the holes.)
• Tighten firmly with the allen key.
Screw may be damaged if you tighten the screw
inserted into the hole crookedly.
•
•
Back Front
3Mount the attachment screw caps.
1
2
Attachment Screw Cap
2 pcs.

12
English
2 Connecting the air plugs (On both the right and left sides)
Insert the air plugs into the unit.
Push on the air
plugs until you hear
it click into place.
Air plug
Front
3 Raising the backrest to the upright position
1Insert the power plug into the
power outlet.
1
2Confirm the lock switch key is
set to the“open” position.
3Confirm the power switch is set
to the“on” position.
4Press button on the
controller twice.
Press once, and then press again approx.
1 second later.
The backrest will rise to the upright position
automatically.
•
23
•

13
English
4 Mount the controller tray on the right side
Mount it on the left side if the right side will be next to the wall or similar.
If you want to mount the controller on the left side
1Press the button on the controller to turn on
the power.
2Press button on the controller and hold until the
legrest has risen far as it will go.
Continue pressing until a “beep-beep-beep” sound is heard.
3Remove the controller cord from the cord-holder groove.
4Move the controller cord under the legrest to the left
side.
5Fasten the controller cord at 2 points in the cord-holder
groove.
Press down from the edge if it does not fit in easily.
•
•
2
Legrest
33
4
5
Cord-Holder Groove
Controller Cord
Push in
Controller Cord
•

14
English
5 Attaching the controller
1Fasten the cord to the groove at the bottom
of tray. 2Place the controller onto the
controller tray.
6 Attaching the back cushion
1Attach the back cushion to the velcro fasteners on the unit.
Velcro fasteners
Back Cushion
7 Attaching the pillow
1Attach the pillow to the velcro fasteners.
See page 33 for a guide to the position of the pillow.
Velcro
fasteners
Pillow
•

15
English
Before sitting down
Check the following before using the unit
1 Check the surrounding area
Make sure there are no objects, people, or pets in the vicinity of the unit.
2 Check the power cord and the power plug
See Warning No. 8 on page 1.
3 Switching on the power supply
1Insert the power plug into an
electrical outlet.
2Turn the lock switch key to the“open”
position.
3Slide the power switch to the “on”
position.
1
23
4 Check the unit
1Make sure there are no tears or rips in the
fabric.
See Caution No. 15 on page 3. Fabric
Backrest
Back cushion

16
English
2Make sure there is no foreign matter
between the unit.
See Caution No. 17 on page 3.
3Make sure the massage heads are in the
retracted position.
When the massage heads are not in the
retracted position
Press the button twice to return the massage heads to the
retracted position.
See Caution No. 3 on page 2.
Hand/Arm massage section
Seat
Leg/Sole massage section
4Make sure the legrest is in the fully lowered
position.
To lower the legrest
Make sure the legrest has fully returned to the original position by pulling
the legrest slide lever, and then press the button twice.
See Caution No. 9 on page 2.
Legrest slide
lever
Retracted position
Check

17
English
When you want a complete massage
Auto program
1
2
1Press the button to turn on the
power.
Flash
The power will turn off automatically if the massage does not start
within 3 minutes after turning on the power.
2Press one of the flashing buttons
() to select the
program.
•
Characteristics of Auto program (upper body)
SWEDISH DEEP SHIATSU
Uses mainly Swedish
massage to gently
invigorate and
promote circulation.
Recommended for
those experiencing
fatigue and weariness.
Uses mainly kneading
to manipulate and
loosen muscles.
Recommended for
those with mild
stiffness and tension.
Uses mainly shiatsu
massage to loosen up
deep-seated knots of
tension.
Recommended for those
with severe stiffness and
tension.
See page 20 for an overview of the respective programs.•
Persons whose height is less than 55 in. (140 cm) or more than 72.8 in. (185 cm) are recommended to use the unit in the
manner described below when the massage heads do not touch their shoulders.
Height is around 55 in. (140 cm) or less Height is around 72.8 in. (185 cm) or more
Use by placing a cushion on the seat and sitting
as far back as possible. Use by reclining the backrest and sliding your
body downward.

18
English
1Body scanning will commence when the program is selected.
The body scanning will properly detect height ranges between approximately 55 and 72.8 in. (140 and 185 cm).
1
2
3
4
Sit as far back in the seat as possible
with your head on the pillow.
Adjust the pillow height
so that the bottom edge
of the pillow is at ear level.
See page 33.
1NECK (Neck)
2SHOULDER (Shoulder) 3MIDDLE (Back)
4LOWER (Lower back)
Correct Massage Position
The unit will automatically recline to the correct
massage position.
Raised
approx. 50°
Reclined
approx. 12°
If the massage lounger is reclined further than the
massage position angle, it will not automatically return
to the correct massage position.
•
2Approximately 30 seconds after the body scanning starts, the massage heads slowly lower to the
shoulder position, and a soft tapping action begins to determine your shoulder position.
Massage Head
Tapping
action
Keep your head on the pillow until the soft tapping
begins.Lifting your head from the pillow will result
in incorrect determination of the shoulder position.
•
3Confirm that the shoulder position has been correctly determined according to the position of the
soft tapping.
When the shoulder position is incorrect, adjust the shoulder position while the soft tapping is in progress (for
approximately 15 seconds), and use the POSITION button to move the massage heads up or down.
<Controller cover opened>
A single press of
the button will
raise or lower the
massage heads
approximately
1/2 in. (1.2 cm).
Too low
Too high
Correct position of
the massage head
(The point where the
tapping action should
be felt.)
4Body scanning is completed when the tapping finishes.
The legrest adjusts automatically so that the soles of the feet
touch the footrest wells according to your estimated height based
on the shoulder position.
If the shoulder position is off drastically, turn the power off once,
and repeat from Step 1 with shoulder firmly pressed against the
backrest.
•
•
•
•

19
English
1
2
3
4
1 Adjusting the intensity of massage for neck,
shoulder, back, or lower back
Intensity of the massage for current
position can be adjusted by turning the dial
on the controller.
For Auto program
Intensity Sensor will function. Movement of the
massage head is adjusted automatically so
the pressure of the massage head pressing
the body stays same even if the curve or
position of the body shifts.
Current position that is getting massaged can
be checked on the display.
Intensity is displayed in 8 steps.
Intensity will not change further even if you
keep turning the dial when the intensity is set
to maximum (8 bars are displayed) or
minimum (1 bar is displayed).
•
•
•
•
Caution
Intensity might increase drastically when the intensity is increased in multiple
steps.Always increase the intensity one step at a time, checking how it feels.
You may not feel the intensity has changed for the following reasons when it is
increased by 1 step:
When the intensity was increased right when the operation has changed.
The feeling is different depending on the person or the position.
•
•
For safety reasons, it is designed not to increase the intensity drastically even if
the dial is turned rapidly.
If you do not feel enough intensity even it is set to maximum, or you feel too
much intensity even it is set to minimum:
<When it does not feel strong enough even the intensity for Auto program
is set to maximum>
Massage heads will press on you stronger with back cushion taken off.
Start at the first level and increase gradually as the intensity will be much greater
without the cushion.
<When it feels too strong even if the intensity for Auto program is set to
minimum>
Pressure of the massage heads will soften by placing a cloth or blanket between
the back cushion and your body.
•
•
To customize
2 Massaging neck and shoulders only/
Massaging back and lower back only
Neck/Shoulder massage will be turned off by pressing button.
Back/Lower Back massage will be turned off by pressing button.
It will resume by pressing it again.
You cannot turn off both Neck/Shoulder and Back/Lower Back at the same time.
Lamp Off
Display for the position will be turned off when
you turn off that position.
(Display on the left shows only neck and
shoulder massage)
•
Table of contents
Other Panasonic Massage Chair manuals