
1-1
EARTH GROUND
1500Ω. 10W
0.15µF
AC VOLTMETER
Hot-Check Circuit
TO
APPLIANCES
EXPOSED
METAL PARTS
GENERAL GUIDELINES
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
ExplodedViewsandReplacementPartsList.Itisessential
that these critical parts should be replaced with
manufacturer's specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. AnIsolationTransformershouldalwaysbeusedduringthe
servicing of Combination VCR whose chassis is not iso-
lated from the AC power line. Use a transformer of ad-
equate power rating as this protects the technician from
accidentsresultinginpersonalinjuryfromelectricalshocks.
It will also protect Combination VCR from being damaged
by accidental shorting that may occur during servicing.
3. Whenservicing,observetheoriginalleaddress,especially
the lead dress in the high voltage circuits. If a short circuit
is found, replace all parts which have been overheated or
damaged by the short circuit.
4. Afterservicing,seetoitthatalltheprotectivedevicessuch
as insulation barriers, insulation papers, shield, and isola-
tion R-C combinations are properly installed.
5. Before turning the receiver on, measure the resistance
betweenB+lineandchassisground.Connect(-)sideofan
ohmmeter to the B+ lines, and (+) side to chassis ground.
Each line should have more resistance than specified, as
follows :
B+ Line Minimum Resistance
130V 1K ohm (Hot chassis ground)
27V 180 ohms (Cold chassis ground)
17V 110 ohms (Cold chassis ground)
6. When the TV set is not used for a long period of time,
unplug the power cord from the AC outlet.
7. Potentials, as high as 25.0KV (Model: A, B, C, D, E) or
30.0KV (Model: F, I) or 29.0KV (Model: G, H) are present
when this TV set is in operation. Operation of the TV set
without the rear cover involves the danger of a shock
hazardfromtheTVsetpowersupply.Servicingshouldnot
beattemptedbyanyonewhoisnotthoroughlyfamiliarwith
the precautions necessary when working on high voltage
equipment.Alwaysdischargetheanodeofthepicturetube
to the CRT ground of receiver before handling the tube.
8. After servicing make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
LEAKAGE CURRENT COLD CHECK
1. UnplugtheACcordandconnectajumperbetweenthetwo
prongs on the plug.
2. For physically operated power switches, turn power on.
Otherwise skip step 2.
3. Measuretheresistancevalue,withanohmmeter,between
the jumpered AC plug and each exposed metallic cabinet
partonthereceiver,suchasscrewheads,connectors,etc.
When the exposed metallic part has a return path to the
chassis, the reading should be between 1 M ohm and 12
M ohms. When the exposed metal does not have a return
path to the chassis, the reading must be infinity.
LEAKAGE CURRENT HOT CHECK
1. Plug the AC cord directly into the AC outlet.
Do not use a isolation transformer for this check.
2. Connect a 1.5K ohms, 10 watts resistor, in parallel with a
0.15 micro farad capacitor, between each exposed metal-
lic part on the set and a good earth ground , as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensi-
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. ReversetheACplugintheACoutletandrepeateachofthe
above measurements.
6. Thepotentialatanypointshouldnotexceed0.75voltRMS.
A leakage current tester (Simpson Model 229 equivalent)
maybeusedtomakethehotchecks,leakagecurrentmust
not exceed 1/2 milliampere. In case a measurement is
outsideofthelimitsspecified,thereisapossibilityofshock
hazard,andthereceivershouldberepairedandrechecked
before it is returned to the customer.
Figure 1
X-RADIATION
WARNING :
1. The potential source of X-Radiation in TV sets is the High
Voltage section and the picture tube.
2. When using a picture tube test fixture for service, ensure
thatthefixture iscapableof handling25.0KV(Model: A,B,
C, D, E) or 30.0KV (Model: F, I) or 29.0KV (Model: G, H)
without causing X-Radiation.
NOTE :
It is important to use an accurate periodically calibrated
high voltage meter.
1. Reduce the brightness to minimum.
2. Set the SERVICE switch to SERVICE .
3. Measure the High Voltage. The meter reading should indi-
cate 23.5 +/- 1.5KV (Model: A, B, C, D, E) or 28.5 +/- 1.5KV
(Model: F, I) or 27.5 +/- 1.5KV (Model: G, H).
Ifthemeterindicationis outoftolerance,immediateservice
and correction is required to prevent the possibility of
premature component failure.
4. TopreventanX-Radiationpossibly,itisessentialtousethe
specified picture tube.
SAFETY PRECAUTIONS