Pentair IntelliFlo VS+ SVRS User manual

IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Installation
and
User’s Guide
IntelliFlo®VS+ SVRS
Variable Speed Programmable Pump
with Safety Vacuum Release System (SVRS) Protection
(Compatible with IntelliComm
®
communication center,
EasyTouch
®
, IntelliTouch
®
and SunTouch
®
control systems)
AUTO HEATER
SPA 100
°
F/95
°
F
AIR 70
°
F
MON 09:30 AM

© 2008 Pentair Water Pool and Spa, Inc. All rights reserved
This document is subject to change without notice
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Trademarks and disclaimers: IntelliFlo®, IntelliComm®, EasyTouch®, IntelliTouch®, SunTouch®and Pentair Water
Pool and Spa®are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated
companies in the United States and/or other countries. Teflon®is a registered trademark of E.I. Du Pont De Nemours
and Company Corporation. Unless noted, names and brands of others that may be used in this document are not
used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water
Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or
others.
P/N 351017 Rev A - 11/19/08
Technical Support
Sanford, North Carolina (8 A.M. to 5 P.M. ET)
Moorpark, California (8 A.M. to 5 P.M. PT)
Phone: (800) 831-7133
Fax (800) 284-4151
Web sites: visit www.pentairpool.com and staritepool.com
Protected by U.S. Patents Pending

i
IntelliFlo VS+ SVRS Installation and User’s Guide
Contents
Warnings and Important Safety Precautions ...................................................... iIi
Section 1: IntelliFlo VS+ SVRS Overview........................................................... 1
IntelliFlo VS+ SVRS Variable Speed Pump .............................................................. 1
Remote Control ................................................................................................... 1
Features .............................................................................................................. 2
IntelliFlo Motor Assembly ......................................................................................... 3
IntelliFlo VS Motor Features ................................................................................. 4
Section 2: Operator Control Panel ..................................................................... 5
IntelliFlo VS+ SVRS Operator Control Panel ........................................................... 5
Stopping the pump ................................................................................................... 7
Section 3: Operating IntelliFlo VS+ SVRS ......................................................... 7
Operating the IntelliFlo VS+ pump at preset speeds ............................................... 7
Pump Operating Modes .......................................................................................... 8
Programming the Pump .......................................................................................... 8
IntelliFlo VS+ SVRS Menus ..................................................................................... 9
Settings: Pump Address .......................................................................................... 10
Settings: Set Time ................................................................................................... 10
Settings: Set AM/PM or 24 Clock ............................................................................. 11
Settings: Set Temperature Unit ................................................................................ 11
Settings: Screen Contrast Level .............................................................................. 11
Settings: Language .................................................................................................. 12
Settings: Set Minimum Speed (RPM) ...................................................................... 12
Settings: Set Maximum Speed (RPM) ..................................................................... 12
Settings: SVRS Auto Restart ................................................................................... 13
Settings: Password ................................................................................................. 14
Password Protection ............................................................................................... 14
Settings: Ramp Speed ............................................................................................ 15
External Control ................................................................................................... 17
Features: Quick Clean ............................................................................................ 17
Programming for Constant Run .......................................................................... 17
Features: Time Out ................................................................................................. 18
Priming .................................................................................................................... 19
AntiFreeze ............................................................................................................... 21
Priming the pump for the first time, or after service ................................................ 22
Priming the Pump.................................................................................................... 23
External Control with IntelliComm Communication Center ..................................... 24
Connecting IntelliFlo VS to an EasyTouch System .................................................. 25
Connecting IntelliFlo VS to an IntelliTouch System .................................................. 28
Connecting IntelliFlo VS to a SunTouch System ...................................................... 30

ii
IntelliFlo VS+ SVRS Installation and User’s Guide
Contents
Section 4: User Maintenance ............................................................................. 31
Pump Strainer Basket ............................................................................................. 31
Pump Strainer Basket Service ................................................................................ 31
Motor Service .......................................................................................................... 32
Winterizing .............................................................................................................. 33
Priming the pump after service ............................................................................... 33
Section 5: Installation and Removal .................................................................... 35
IntelliFlo VS+ Kit Contents ....................................................................................... 35
Installing the IntelliFlo VS ......................................................................................... 35
Location ............................................................................................................... 35
Piping ................................................................................................................... 35
Check Valve ............................................................................................................. 35
Wiring the IntelliFlo VS Pump .................................................................................. 36
To connect the IntelliFlo VS to an AC power source ............................................ 36
Initial SVRS Setup and Operational Check .......................................................... 36
Pump Disassembly ................................................................................................. 37
Pump Reassembly/Seal Replacement ............................................................... 38
Shaft Seal Replacement...................................................................................... 38
Drive Assembly Removal and Installation ............................................................ 39
Replacement Parts ................................................................................................. 40
Illustrated Parts List ............................................................................................. 40
IntelliFlo VS Flow and Power vs Flow Pump Curve ................................................. 41
IntelliFlo VS Electrical Specifications ....................................................................... 41
Section 6: Troubleshooting ................................................................................. 43
IntelliFlo VS Pump Dimensions ............................................................................... 41
Alerts and Warnings ................................................................................................ 43
Suction Blockage ..................................................................................................... 43
SVRS Blockage ....................................................................................................... 43
General IntelliFlo VS Troubleshooting Problems ...................................................... 44
General Warnings.................................................................................................... 46
Electrical Cost Overview ......................................................................................... 46
Using the IntelliFlo VS pump .................................................................................... 47
Automatic pool sweeps (booster pump style) ......................................................... 47
Filter during off-peak times ...................................................................................... 47
Setting filtering time ................................................................................................. 47
How to make your pool more energy efficient.......................................................... 47
Preventive maintenance .......................................................................................... 48
Energy Efficient IntelliFlo VS pump .......................................................................... 48

iii
IntelliFlo VS+ SVRS Installation and User’s Guide
Important Notice:
Attention Installer: This manual contains important information about the installation, operation and safe use
of this product. This information should be given to the owner and/or operator of this equipment.
Please refer to www.pentair.com for all warnings and instructions related to the IntelliFlo®VS+SVRS pump.
Before installing this product, read and follow all warning notices and instructions
which are included. Failure to follow safety warnings and instructions can result in
severe injury, death, or property damage. Call (800) 831-7133 for additional free copies
of these instructions. It is absolutely critical that the suction plumbing be installed in
accordance with the latest national and local codes for swimming pools.
These instructions contain information for a variety of pump models and therefore some
instructions may not apply to a specific model. All models are intended for use in
swimming pool applications. The pump will function correctly only if it is properly sized
to the specific application and properly installed.
This pump produces high levels of suction, which can pose extreme danger if a
person comes in close proximity to an open pool or spa drain or a loose or broken
drain cover or grate. The IntelliFlo VS+SVRS pump, when installed according to the
manufacturer's instructions, is designed to help prevent injuries caused by body
entrapment in pools. This pump does not, however, protect against limb
entrapments, disembowelments (when a person sits on a broken or uncovered pool
drain) or hair entanglements.
This pump is not a substitute for properly installed and secured pool drain covers.
An ANSI/ASME A112.19.8 approved anti-entrapment drain cover must be used for
each drain. Pools and spas should utilize two drains per pump. If a drain cover
becomes loose, broken or is missing, close the pool or spa immediately and shut off
the pump until an approved anti-entrapment drain cover is properly installed with the
manufacturer's supplied screws.
The SVRS (Safety Vacuum Release System) feature of this pump is inactive during
priming. The SVRS feature is an integral part of a complete safety system. During
priming mode, the pump does not monitor blocked suction or discharge system
conditions. Swimmers should not be allowed in the pool during the "inactive" SVRS
mode. When "SVRS" text is not displayed on the control panel screen, the SVRS
system is disabled.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Body
ForeArm
Upper
Arm
Leg Joint
Leg Joint
Leg Joint
Leg Joint

iv
IntelliFlo VS+ SVRS Installation and User’s Guide
Entrapment Avoidance Notice:
The covers used on suction outlets should be approved and listed as conforming to the currently
published edition of ANSI/ASME A112.19.8 Standard. These covers should be inspected
regularly and replaced if cracked, broken or older than the design lifetime indicated on them by
the manufacturer. The maximum possible flow rate of this pump should be less than or equal
to the maximum approved flow rate indicated on the suction outlet cover by the manufacturer.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN
COVERS ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB
ENTRAPMENT, HAIR ENTANGLEMENT, EVISCERATION AND DEATH.
The Virginia Graeme Baker Pool and Spa Safety Act raises certain new requirements on owners and operators of
swimming pools and spas.
Pools or spas constructed on or after December 20, 2008, shall utilize:
(A) No submerged suction outlets, a gravity drainage system with ASME/ANSI cover(s), one or more unblockable
outlets; or
(B) A multiple main drain system without isolation capability with suction outlet covers that meet ASME/ANSI
A112.19.8 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
(i) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety
Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub,
and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for Manufactured
Safety Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs or
(ii) A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-off system.
Pools and spas construction prior to December 20, 2008, with a single submerged suction outlet shall use a suction
outlet cover that meets ASME/ANSI A112.19.8 and either:
(A) A multiple main drain system without isolation capability, or
(B) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
(C) A properly designed and tested suction-limiting vent system, or
(D) An automatic pump shut-off system, or
(E) Disabled submerged outlets, or
(F) Suction outlets shall be reconfigured into return inlets.
For more information about the Act, contact the Consumer Product Safety Commission at 301 504 7908
or visit www.cpsc.gov.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
NOTE: VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT

v
IntelliFlo VS+ SVRS Installation and User’s Guide
Risk of electrical shock or electrocution:
This pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes
and ordinances. Improper installation will create an electrical hazard which could result in
death or serious injury to pool users, installers, or others due to electrical shock, and may
also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker and remove the
RS-485 communication cable from the pump before servicing the pump. Failure to
do so could result in death or serious injury to serviceman, pool users or others
due to electric shock.
Water temperature in excess of 100° Fahrenheit may be hazardous to your health.
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when
the internal temperature of the body reaches a level several degrees above normal body
temperature of 98.6° F. (37° C.).
The effects of hyperthermia include: 1) Unawareness of impending danger. 2) Failure to
perceive heat. 3) Failure to recognize the need to leave the spa. 4) Physical inability to exit
the spa. 5) Fetal damage in pregnant women. 6) Unconsciousness resulting in danger of
drowning.
SVRS devices shall only be installed in conjunction with ASME A112.19.8 suction fitting,
or a 12 in. x 12 in. (305 mm x 305 mm) drain grate or larger, or an approved channel
drain system at each suction outlet or drain outlet.
All SVRS devices shall be factory set or field adjusted to site-specific hydraulic conditions.
Once installed, the system shall be tested by simulating an entrapment event.
A ball, butterfly, or sliding gate valve shall be installed within 2 ft. (0.6m) upstream from the
SVRS (between the SVRS and the protected suction outlet), or a test mat shall be used to
cover the suction outlet to simulate an entrapment event. There shall be three simulated
entrapment tests conducted to verify proper adjustment and operation of the device.
SVRS (Safety Vacuum Release System) feature is DISABLED during priming. When
"SVRS" text is not displayed on the control panel screen, the SVRS feature is disabled.
The IntelliFlo® VS+SVRS pump ("pump") has been designed to specifically operate with
Pentair Water Pool and Spa control systems. Operating the pump with other manufacturers'
controllers may cause software failure of the pump, drive or other system components. Such
failure can result in severe personal injury (i.e., failure of the SVRS system, electrical shock)
or death. If installed properly, an IntelliComm® controller may be used to integrate other
manufacturer’s controllers.
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS

vi
IntelliFlo VS+ SVRS Installation and User’s Guide
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
The presence of a hydrostatic valve in the suction piping has been shown to prolong
the high vacuum present at the drain, even through the drain was protected by an
SVRS device.
• Check valves and hydrostatic valves shall not be used with this pump;
• Check valves should not be installed on the suction or discharge side of the system
protected by an SVRS device.
Never open the inside or the drive motor enclosure. There is a capacitor bank that holds a
230 VAC charge even when there is no power to the unit.
The IntelliFlo SVRS pump is capable of 174 GPM or 104 feet of head; use caution when installing
and programming to limit pumps performance potential with old or questionable equipment.
Pumps improperly sized or installed or used in applications other than for which the pump was
intended can result in severe personal injury or death. These risks may include but not be limited
to electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by
a structural failure of the pump or other system component.
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia
in hot tubs and spas.
To reduce the risk of injury, do not permit children to use this product unless they are
closely supervised at all times.
For units intended for use in other than single-family dwellings, a clearly labeled emergency
switch shall be provided as part of the installation. The switch shall be readily accessible
to the occupants and shall be installed at least 5 feet (1.52 m) away, adjacent to, and
within sight of, the unit.
When setting up pool water turnovers or flow rates the operator must consider local codes
governing turnover as well as disinfectant feed ratios.

vii
IntelliFlo VS+ SVRS Installation and User’s Guide
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Install the pump a minimum of five (5) feet from the inside wall of the pool and spa. Canadian
installations require a minimum of three (3) meters from pool water.
A No. 8 AWG or larger conductor must be wired to the motor bonding lug.
This pump is for use with permanently installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A permanently installed pool is constructed
in or on the ground or in a building such that it cannot be readily disassembled for storage. A
storable pool is constructed so that it may be readily disassembled for storage and reassembled
to its original integrity and has a maximum dimension of 18 feet (5.49m) and a maximum wall
height of 42 inches (1.07m).
For hot tubs and spa pumps, do not install within an outer enclosure or beneath the skirt of a hot
tub or spa unless so marked.
IntelliFlo VS+ SVRS is capable of generating systems pressures up to 50 psi. Installers must
ensure that all system components are rated to withstand at least 50 psi. Over pressurizing the
system can result in catastrophic component failure or property damage.
Two Speed Pump Controls Notice (Title 20 Compliance)
Please read the following important Safety Instructions (See page 6 for pump speed setup). When
using two-speed pumps manufactured on or after January 1, 2008, the pump's default circulation
speed MUST be set to the LOWEST SPEED, with a high speed override capability being for a
temporary period not to exceed one normal cycle, or two hours, whichever is less.

viii
IntelliFlo VS+ SVRS Installation and User’s Guide
Blank Page

1
IntelliFlo VS+ SVRS Installation and User’s Guide
Section 1
IntelliFlo VS+ SVRS Overview
IntelliFlo®VS+ SVRS Variable Speed Pump
The IntelliFlo VS+ SVRS variable speed pump with the safety vacuum release system (SVRS) protection is
well suited for all of your pool, spa, waterfall and other applications. The IntelliFlo VS+ SVRS can use up
to eight (8) speeds which can be adjusted to run at specific speeds and time intervals. IntelliFlo out
performs all conventional pumps in its class. Advanced energy conservation features ensure that your
filtration system is operating at peak efficiency.
The IntelliFlo pump operates at a maximum system flow rate of up to 174 gallons per minute (GPM).
System setup for the SVRS requires that the suction vacuum level be adjusted to 25" of mercury (Hg) or
less at the pump strainer housing connection.
The IntelliFlo VS+ SVRS pump can operate from 1100 RPM to 3450 RPM with preset speeds of 1100,
1500, 2350 and 3110 RPM. The pump can be adjusted from the control panel to run at any speed
between 1100 RPM to 3450 RPM for different applications. The IntelliFlo pump control panel alarm LED
and error messages warn the user against under and over voltage, high temperature, over current, suction
blockage and freeze protection with user defined minimum and maximum speed presets. See page 39 for
additional information.
This pump is intended to be used as part of a complete pool safety system. It complies with theASME/
ANSIA112.19.17-2002 SVRS standard which defines how fast the pump must stop on a suction blockage
event. This pump may not protect individuals from hair entrapment, limb entrapment or evisceration. The
operator must ensure that all suction and return fittings are clean and unobstructed whenever the pump is
started. Because SVRS protection is not enabled during priming mode, never allow anyone in the
pool during priming mode.
If SVRS auto restart is enabled and an SVRS event occurs, the pump is allowed to restart automatically
after the preset time period. The operator must insure that any SVRS blockage event is quickly
evaluated to confirm that all suction and return fittings are clean and unobstructed. When the pump
restarts after a high vacuum event it will slowly ramp up to speed. If the pump senses a blockage it will shut
down. The pump will attempt to soft prime 10 times before attempting a full prime.
Remote Control
The IntelliFlo VS+ SVRS can communicate with an
IntelliTouch®, EasyTouch®, or SunTouch®control system or the
IntelliComm®communication center via a two-wire RS-485
cable provided with the pump. EasyTouch and IntelliComm
can remotely control the IntelliFlo VS+ SVRS four preset
speeds. The IntelliTouch system can be configured to control a
total of eight speeds. The pump’s address and other pump
functions are accessed from the pump’s control panel.
IntelliFlo VS+ SVRS Variable Speed Pump

2
IntelliFlo VS+ SVRS Installation and User’s Guide
12 Programmable Speeds
Eight Set speeds
Schedule
Duration
Manual
Four IntelliComm speed modes
Priming Feature (SVRS does not function in this mode)
Load Sensing
Enable or Disable
Lock out protection
Four Digit password
Enable or Disable
LCD Display
Power and Speed
Text Alerts
Antifreeze Protection
Adjustable speed
Adjustable Temperatures
Enable and Disable in stand alone
Additional Features
Clock and Timer
Maximum and Minimum Speed Limits
Quick Clean Mode
Address up to 16 pumps
Service Features
Timeout Mode
ASMEA112.19.17 SVRS compliant and certified by ETL
SVRS feature accommodates flooded and elevated suction for pump with suction levels at pump
strainer at 25” mercury (Hg)
SVRS feature requires no special plumbing or electrical connections
Features
Adjusts to various pool sizes
Prevents thermal overload
Detects and prevents damage from under and over voltage conditions
Protects against freezing
Communicates with a Pentair EasyTouch, IntelliTouch or SunTouch control system or IntelliComm
communication center via a two-wire RS-485 cable connection
Easy to use operator control panel
Operator control panel buttons for speed control
Built-in strainer pot and volute
Ultra energy-efficient TEFC Square Flange Motor
Compatibility with most cleaning systems, filters, and jet action spas
Motor assembly features permanent magnet synchronous motor
Heavy-duty, durable construction designed for long life
UL, ETL and NSF approval

3
IntelliFlo VS+ SVRS Installation and User’s Guide
IntelliFlo Motor Assembly
The IntelliFlo three-phase six-pole motor operates from 3450 RPM to 1100 RPM. The drive assembly is
continually cooled by an external fan. Dual seals on the motor drive shaft and at the fan shaft assembly seal
the entire motor and bearings from any dirt and moisture entering the motor assembly. For added
protection, a slinger located in front of the main motor shaft seal assists in slinging water away from the shaft
opening in the flange.
Drive assembly and
electronics enclosure
IntelliFlo Motor Assembly
Motor fan cover
Control panel cover
Communication port for connection
to EasyTouch, IntelliTouch or
SunTouch control system or
IntelliComm communication center
via two-wire RS-485 cable
Motor assembly

4
IntelliFlo VS+ SVRS Installation and User’s Guide
IntelliFlo Drive Assembly and Control Panel
The IntelliFlo drive assembly consists of an operator control panel and the system electronics that drive the
motor. The drive microprocessor controls the motor by changing the frequency of the current it receives
together with changing the voltage to control the rotational speed.
IntelliFlo VS Motor Features
• Permanent Magnet Synchronous Motor (PMSM)
• High efficiency
• Superior speed control
• Operates at lower temperatures due to high efficiency
• Same technology as deployed in hybrid electric vehicles
• Designed to withstand outdoor environment
• Totally enclosed fan cooled
• Three-phase motor
• 56 Square Flange
• Six-Pole
• Low noise
Motor stand
Operator Control Panel,
buttons and LED
(see page 5)
IntelliFlo Drive Assembly
AC power connection
compartment
(see page 32)
Vacuum gauge
installation locations
(see page 35)

5
IntelliFlo VS+ SVRS Installation and User’s Guide
Section 2
Operator Control Panel
This section describes the IntelliFlo VS+ SVRS operator controls and LEDs.
IntelliFlo VS+ SVRS Operator Control Panel
Controls and LEDs
Speed 1 button/LED: Press button to select Speed 1 (1100 RPM). LED on indicates Speed 1 is active.
Speed 2 button/LED: Press button to select Speed 2 (1500 RPM). LED on indicates Speed 2 is active.
Speed 3 button/LED: Press button to select Speed 3 (2350 RPM). LED on indicates Speed 3 is active.
Speed 4 button/LED: Press button to select Speed 4 (3110 RPM). LED on indicates Speed 4 is active.
Select button: Displays available menu items or enters edit mode for changing a value on line two of the display.
Escape button: Moves to next level up in the menu structure, and/or stops editing the current setting.
Menu button: Accesses the menu items if the pump is stopped.
Enter button: Saves current menu item setting. Press this button to acknowledge alarms and warning alerts.
FILTER 12:15
15.W
15.W
POWER
RUNNING
1
5
2
6
8
4
3
7
®
1
2
3
4
5
6
7
8
Speed
1
Speed
2
Speed
3
Speed
4
Quick
Clean
Time
Out
1100 RPM
T 0.00
Running Speed 1
SVRS ENABLED when
displayed (see page 13) SVRS
Key Lockout Icon
150 WATTS
Current Speed
Count down Time
Current feature running
Current Time
Current Power usage

6
IntelliFlo VS+ SVRS Installation and User’s Guide
Controls and LEDs (Continued)
Arrow buttons:
•Up arrow: Move one level up in the menu tree or increase a digit when editing a setting.
•Down arrow: Move one level down in the menu tree or decrease a digit when editing a setting.
•Left arrow: Move cursor left one digit when editing a setting.
•Right arrow: Move cursor right one digit when editing a setting.
Quick Clean: Duration and speed (RPM) can be preset to save energy. The LED is on when active.
Time Out: When active (LED on), at the end of a “Time Out” preset time, the pump will run a schedule.
Start/Stop button: Start or Stop the pump. When the LED is on, the pump is currently running or in a
mode to start automatically.
Reset button: Reset alarm or alert.
LEDs
On: This green, power LED is on when IntelliFlo VS is powered on.
Warning: LED is on if a warning condition is present.
Alarm: The green LED is on if an alarm condition occurs. See “Alerts and Warning” on page 39.
Control Panel LCD:
• Line 1 - Key icon indicates password protect mode is active. If password protect is not enabled, no key icon
is displayed. SVRS indicates pump is in SVRS protect mode. If SVRS is not displayed, SVRS is
not active. System time is displayed on the right side of top line.
• Line 2 - Displays the current pump speed (RPM).
• Line 3 - Count down time and Watts
• Line 4 - Current pump status.
FILTER 12:15
15.W
15.W
POWER
RUNNING
10
11
15
14
9
13
12
Line 1
Line 2
Line 3
Line 4
®
9
10
11
12
13
15
Speed
1
Speed
2
Speed
3
Speed
4
Quick
Clean
Time
Out
15.W
14
1100 RPM
T 0.00
Running Speed 1
SVRS
150 WATTS

7
IntelliFlo VS+ SVRS Installation and User’s Guide
Section 3
Operating IntelliFlo VS+ SVRS
This section describes how to operate the IntelliFlo VS+ SVRS pump using the control panel buttons and menu
features.
Starting the pump
To start the pump
1. Be sure the pump is powered on and the green power LED is on.
2. Select one of the speed buttons, then press the Start button (LED on) to start the pump.
Stopping the pump
To stop the pump
• Press the Stop button to stop the pump.
Note: The pump can automatically restart if the communication cable is connected.
Servicing Equipment (Disconnect Power to Pump)
• When servicing equipment (filters, heaters, chlorinators etc.), disconnect the communication cable,
and switch OFF circuit breaker to remove power from the pump
Operating the IntelliFlo VS+ pump at preset speeds
The IntelliFlo VS+ pump is programmed with four default speeds of 1100, 1500, 2350 and 3110 RPM. A
Speed button is assigned to each of the preset speeds as shown.
To operate the pump at one of the four preset speeds
1. Be sure the pump is powered on and the green power LED is on.
2. Press the Speed button (1- 4) corresponding to the desired preset speed, and release quickly. The
LED above the Speed button will come on as shown.
3. Press the Start button. The pump will quickly ramp to the selected preset speed.
Adjusting the pump speed
1. While the pump is running, press the Up Arrow to increase speed setting.
2. Press the Down Arrow to decrease speed Setting.
3. Press and hold down a Speed Button for three (3) seconds to save speed to the button or press the
Enter button to save the speed.
Speed
1
Speed
2
Speed
3
Speed
4
LED lit

8
IntelliFlo VS+ SVRS Installation and User’s Guide
Pump Operating Modes
The IntelliFlo VS+ pump can be programmed three ways:
1. Manual Operation: Speed buttons 1-4 can be programmed for Manual operation. This means the
speed button is pressed and then the start button and the pump runs a programmed speed. Speeds
5-8 can not be programmed for Manual operation because there are no buttons associated with
them.
To operate the pump in Manual Mode, press one of the four speed buttons, and press the Start/Stop
button to run the assigned speed for that button. When the pump is running a Manual Speed Setting
(speed 1, 2, 3 or 4 button pressed manually) and a scheduled speed is set to run, the scheduled
speed will take priority regardless of speed number of RPM. When the Scheduled Speed's time is
over, it will not revert back to the manually pressed speed. If the pump is running a schedule and a
speed button is pressed manually, the pump will run the manually selected speed until the next
scheduled speed program.
2. Egg Timer (Duration): Speeds 1-4 can be programmed to run for a duration of time once pressed.
This means that the Speed button is pressed and then the start button and the pump runs a
programmed speed and the speed will turn off at the end of a preprogrammed amount of time.
Speeds 5-8 have no direct pump speed buttons and therefore cannot be programmed with an Egg-
Timer.
3. Schedule: The speed button can be programmed to turn on and off at a certain time. The LED
above the Start/Stop button must be lit for the pump to run schedules. When a speed is set to run in
Schedule mode it can still be operated manually. When a speed is programmed to run 23 hours and
59 minutes per day it will not turn off. For example, for the pump to run 24 hours per day, program
the pump to start at 8:00 AM and stop at 7:59 AM.
Programming the Pump
When the pump is running a manual speed and password time out is activated the pump can be turned off but it
cannot be turned back on. Pressing the Start/Stop button places it in the Running Schedule mode. Therefore, it
will only run Speeds that are Scheduled to come on at their scheduled Start Time.

9
IntelliFlo VS+ SVRS Installation and User’s Guide
IntelliFlo VS+ SVRS Menus
Press MENU button to access menus
MAIN SCREEN
(page 10)
SETTINGS (1-16) Default: ADDRESS 1
(hr:mm) Default: 12:00 AM
Set AM/PM AM/PM
24 hr.
Fahrenheit - Default: F˚
C˚ Celsius
(1-5) Default 3
(1100 RPM - 1700 RPM) - Default: 1100 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Pump Address
Set Time
Temperature Unit
Screen Contrast
Language
Set Min Speed
Set Max Speed
PASSWORD
Password Time Out (1 min. - 6 hours) Default:10 minutes
Disabled/Enabled - Default: Disabled
Enter Password (xxxx) Default: 1234
(page 12)
SPEED 1-8 Speed 1 (1-4)
Manual
Schedule
Egg Timer
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
(page 17)
EXT CONTROL Program 1
Speed - Default: 1100 RPM
Speed - Default: 1500 RPM
Program 2
(page 17)
FEATURES
Quick Clean Set Speed (1100 -3450 RPM) Default: 3450 RPM
Time (1 min. to 10 hrs.) Default: 10 minutes
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Time Out
(page 19)
PRIMING DISABLED/ENABLED
(1 min. to 30 min. hrs.) Default: 11 minutes
MAX PRIMING TIME
(page 21)
ANTI FREEZE
Disabled / Enabled - Default: Enabled
Program 3
Speed - Default: 2350 RPM
Speed - Default: 3110 RPM
Program 4
English - Default: English
SVRS Auto Restart
SVRS Restart Time (30 sec. - 5 mins.) Default 2 minutes
Disabled/Enabled - Default: Enabled
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
RAMP SPEED (5 RPM - 400 RPM) Defualt: 200 RPM
Disabled Default: Disabled
Default: Enabled
(1 - 100%) Default: 1
PRIMED SENSITIVITY
(1 second - 10 minutes) Default: 20 seconds
PRIMING DELAY
DISABLED/ENABLED
SET SPEED
40˚ F - 50˚ F (4.4˚ C - 10˚ C) Default: 40˚ F (4.4˚ C)
PUMP TEMPERATURE
Set Speed (1100 RPM - 3450 RPM) Default 1100 RPM

10
IntelliFlo VS+ SVRS Installation and User’s Guide
IntelliFlo VS+ Menus
The IntelliFlo VS+ menu descriptions are as follows:
Settings: Pump Address
The IntelliFlo pump address needs to be changed when there is more than one IntelliFlo pump on an automation
system. Addressing the pump allows the automation system to know which pump to send a command to. The
“PumpAddress” setting is used when the IntelliFlo VS+ is connected via the RS-485 COM port to an
IntelliTouch®, EasyTouch®, SunTouch®or IntelliComm®system. The default pump address is #1. When
connected to EasyTouch®, SunTouch®or IntelliComm®the pump only communicates with address #1. The
pump address can be set from 1-16. However, IntelliTouch can communicate to four (1-4) IntelliFlo VS pumps.
Note: IntelliFlo pumps cannot be connected in series with other pumps.
To access the Settings menu:
1. Be sure the green power LED is on and the pump is stopped.
2. Press the Menu button. “Settings” is displayed.
3. Press the Select button. “Pump Address” is displayed. The Factory default setting is address “1.”
4. To change the pump address, press the Select button. The first digit “1” selected.
5. Press Up or Down arrow button to change the address number from 1-16.
6. Press the Enter button to save the setting. To cancel any changes, press the Escape button to exit
edit mode without saving.
7. Press the Escape button to exit.
Settings: Set Time
Use “Set Time” to set the IntelliFlo VS+ system time.The IntelliFlo VS+ system clock controls all scheduled
start and stop times, functions, and programmed cycles. The system clock can store the correct time for up to
96 hours after power is shut off. The IntelliFlo will retain the time memory for 96 hours before a reset is needed.
To access the Set Time menu:
1. Check that the green power LED is on.
2. Press the Menu button. “Settings” is displayed.
3. Press the Select button. “Pump Address” is displayed.
4. Use the Up or Down arrow button to scroll to “Set Time”
5. Press the Select button. The cursor will appear in the Minutes column.
6. Press Up or Down arrow button to set the time.
7. Press the Enter button to save the setting. To cancel any changes, press the Escape button to exit
edit mode without saving.
8. Press the Escape button to exit.