Pepperl+Fuchs BTC01 User manual

Industrial Box Thin Client
BTC01
PROCESS AUTOMATION
MANUAL

With regard to the supply of products, the current issue of the following document is ap-
plicable: The General Terms of Delivery for Products and Services of the Electrical Indus-
try, published by the Central Association of the Electrical Industry (Zentralverband
Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the
supplementary clause: "Expanded reservation of proprietorship"
Industrial Box Thin Client

Industrial Box Thin Client
3
1 Safety ........................................................................................... 4
1.1 Introduction .......................................................................................... 4
1.1.1 Content of this Document .................................................................. 4
1.1.2 Target Group, Personnel .................................................................... 4
1.1.3 Symbols Used.................................................................................... 5
1.2 Warnings and Cautions ....................................................................... 5
2 Product Description ................................................................... 6
2.1 Application............................................................................................ 6
2.2 RM Shell ................................................................................................ 6
2.3 ACP ThinManager Ready .................................................................... 7
2.4 Technical Data ...................................................................................... 7
2.5 Accessories .......................................................................................... 9
3 Installation................................................................................. 11
3.1 Mounting ............................................................................................. 11
3.2 Electrical Connection ........................................................................ 13
3.3 I/O Connection ................................................................................... 15
3.3.1 Use of PS/2 Ports in Hazardous Locations....................................... 21
4 Commissioning......................................................................... 22
4.1 Video Card Option.............................................................................. 22
4.2 Power Mode Options ......................................................................... 22
4.3 Multiple Display Setup....................................................................... 22

2018-10
4
Industrial Box Thin Client
Safety
1Safety
1.1 Introduction
1.1.1 Content of this Document
This document contains information that you need in order to use your product throughout the
applicable stages of the product life cycle. These can include the following:
■Product identification
■Delivery, transport, and storage
■Mounting and installation
■Commissioning and operation
■Maintenance and repair
■Troubleshooting
■Dismounting
■Disposal
The documentation consists of the following parts:
■Present document
■Instruction manual
■Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
■EU-type examination certificate
■EU declaration of conformity
■Attestation of conformity
■Certificates
■Control drawings
■Additional documents
1.1.2 Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and
dismounting lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation,
commissioning, operation, maintenance, and dismounting of the product. The personnel must
have read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
Note!
This document does not substitute the instruction manual.
Note!
For full information on the product, refer to the instruction manual and further documentation on
the Internet at www.pepperl-fuchs.com.

Industrial Box Thin Client
Safety
2018-10
5
1.1.3 Symbols Used
This document contains symbols for the identification of warning messages and of informative
messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory
that you observe these warning messages for your personal safety and in order to avoid
property damage.
Depending on the risk level, the warning messages are displayed in descending order as
follows:
Informative Symbols
Action
This symbol indicates a paragraph with instructions. You are prompted to perform an action or
a sequence of actions.
1.2 Warnings and Cautions
Depending on the device marking, this device is suitable for use in Class I/Div 2,
Groups A, B, C and D, or non-hazardous locations only. Consult local electrical codes for
hazardous location installation guidelines.
Special Conditions of Use for Hazardous Locations
■Mount device in a suitable enclosure providing a minimum degree of protection of
NEMA 4x or IP54, which only allows access by using a tool.
■Supply the device with a power supply that meets the requirements for safety extra-low
protective voltage (SELV) or protective extra-low voltage (PELV).
■Do not connect or disconnect the external connections of the I/O in the presence of an
explosive atmosphere.
■The total current draw on all USB connections combined must not exceed 1 A.
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in
their complete failure.
Note!
This symbol brings important information to your attention.

2018-10
6
Industrial Box Thin Client
Product Description
2 Product Description
2.1 Application
BTC01 is a rugged, industrial-grade box thin client. With a fanless design, this box thin client is
specially designed to withstand extended temperatures, as well as shock and vibration
resistant per IEC 60068.
It is a small-footprint, stand-alone computer with an Intel Bay Trail series quad-core Celeron
processor and optional PCI-E graphics card, to allow connection of up to four desktop
monitors. The housing consists of an aluminum extruded body for the top and sides, and a
powder-coated aluminum base.
Overall, the BTC01 is ideal for monitoring and control applications in factory and process
automation. Its high quality workmanship ensures reliable operation under harsh environmental
conditions.
2.2 RM Shell
RM Shell 4.x or 5.x is the operating system software that runs on the BTC01 industrial box thin
client.
VisuNet RM Shell (RM Shell) embedded operating system enables users to easily access
applications that run on a host system (e.g., workstation PC or server) via Ethernet.
RM Shell 4.0 supports common remote protocol, such as RDP 8.0 or VNC.
RM Shell 5 is based on Windows®10 IoT Enterprise LTSB—an embedded version of
Windows®with long-term support that is compatible with the latest versions of common remote
protocols such as RDP 10, Citrix Receiver, and VNC.
With these protocols, the BTC01 and other VisuNet Remote Monitors can be easily integrated
into all major process control systems, whether they are virtualized or conventional,
workstation-based setups.
Also installed is a hardware driver for ELO touch screen controller. When connecting a third
party ELO touch screen, connection must be done via USB. The ELO touch driver supports
most ELO touch devices. Please contact Pepperl+Fuchs to ensure compatibility.
For more information on using RM Shell 4.x or 5.x, refer to the VisuNet RM Shell manual.
Warning!
The Industrial Box Thin Client BTC01 is a self contained unit with no customer accessible
parts.
Warning!
Warranty
The BIOS may not be accessed. Any tampering with BIOS is at your own liability, and is not
covered under warranty for repairs.
Warning!
Radio Interference
This device is compliant to class A industrial limits and is intended for use in idustrial settings.
In a domestic environment this product may casue radio interference in which the user may be
required to take adequate additional measures.
Note!
Visit www.pepperl-fuchs.com regularly to check on the latest version of RM Shell.

Industrial Box Thin Client
Product Description
2018-10
7
2.3 ACP ThinManager Ready
As an alternative to the VisuNet RM Shell 4.x or 5.x, the BTC01 can also be order as
ThinManager "Ready", by having a customized PCI expansion ROM installed in the BIOS.
When this feature is ordered, the ThinManager server installs the running OS onto the BTC01
over the LAN connection.
ThinManager is a software created by ACP. The software allows centralized management of
thin client architecture, allowing ThinManager Ready thin clients to be configured in a central
location instead of individually at each client.
The ThinManager shows the following information:
■thin clients are operating
■terminal servers the clients are assigned to
■thin clients log-in information
■applications run by the thin clients
ThinManager partners with certain thin client manufacturers like Pepperl+Fuchs to flash the
BIOS of their hardware to ensure it automatically boots into the ThinManager environment.
These are referred to as ThinManager-Ready devices. In this configuration, you can
seamlessly connect to the ThinManager infrastructure without any IT set-up.
The BTC01 can only support dual video out when used as a ThinManager Ready device. Quad
video is not supported.
ACP ThinManager supports a variety of third party touch screens. Please contact ACP to verify
compatibility.
2.4 Technical Data
Figure 2.1 Dimensions BTC01
236
77.5
229

2018-10
8
Industrial Box Thin Client
Product Description
Hardware
Processor Celeron J1900
Graphics controller: Intel®Gen7 Graphics DX 11*,
OGL3.2
GPU (expansion): NVIDIA GeForce GT 730 (2 GB
memory)
RAM 4 GB DDR3L
Mass storage 32 GB mSATA
Supply
Power supply 100 ... 240 V AC, 50 ... 60 Hz, 40 W max.
12 V DC, 4.0 A\r 18 ... 30 V DC, 2.6 ... 1.6 A
Power ON AT/ATX Supp orted
AT: Directly PWR on as operating voltage ready
ATX: Press Button to PWR on after operating voltage
ready
Interface
Interface type USB: Front: 2 x USB 2.0, rear: 2 x USB 2.0, 2 x USB 3.0
LAN: 2 x RJ45 (Gigabit Ethernet)
Serial: 3 x RS232
Video (standard): 1 x HDMI (up to WUXGA, 1920 x
1200), 1 x VGA (up to WUXGA, 1920 x 1200)
Video (option): 1 x HDMI (up to 3840 x 2160 @ 30Hz); 1
x DVI-D (up to WQXGA, 2560 x 1600)
Audio: 1 x mic in, 1 x line out
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1
Low voltage
Directive 2014/35/EU EN 60950-1
Software
Operating system Windows®10 IoT Enterprise x64
(VisuNet RM Shell 5.x)
Windows® Embedded Standard
(VisuNet RM Shell 4.x)
Ambient conditions
Operating temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -20 ... 70 °C (-4 ... 158 °F)
Relative humidity 0 ... 95% non-condensing
Shock resistance operating: 20 g , 11 ms all axis, IEC 60068-2-27
Vibration resistance operating: 2 g rms , 5 ... 500 Hz , IEC 60068-2-6
Mechanical specifications
Degree of protection IP41 (with I/O covers or cables plugged in)
Mass 3.5 kg
Dimensions 229 mm x 236 mm x 77.5 mm

Industrial Box Thin Client
Product Description
2018-10
9
2.5 Accessories
Mounting Kits
Video Adaptors
Connection Cables AC Power
Connection Cables 12 V DC Power
12 V DC Power Supply
International approvals
UL approval Hazardous locations: UL Listing E190294; Class I, Div
2, Groups A, B, C, D (18 ... 30 V DC version only)
Ordinary locations: UL Listing E185778 (all DC
versions)
Accessories Designation
Boxed Thin Client wall mount kit BTC-Wallmount-Kit-1
Accessories Designation
Video Adaptor; DVI-D male to VGA female ADP-V-DVIM-VGAF
Video Adaptor; HDMI male to VGA female ADP-V-HDMIM-VGAF
Video Adaptor; HDMI male to DVI-D female ADP-V-HDMIM-DVIF
Video Adaptor; DVI-D male to HDMI female ADP-V-DVIM-HDMIF
Accessories Designation
AC power cord; IEC320-C13 to US/Japan S-BN-12/1500-US/JP2
AC power cord; IEC320-C13 to European S-BN-12/1500-EU2
AC power cord; IEC320-C13 to United Kingdom S-BN-12/1500-UK2
AC power cord; IEC320-C13 to Australian S-BN-12/1500-AU2
Note!
All units ship with US/Japan AC power cord. For other regions, power cords must be ordered
seperately
Accessories Designation
AC power cord; IEC320-C8 to US/Japan S-BN-24/1500-US/JP1
AC power cord; IEC320-C8 to European S-BN-24/1500-EU1
AC power cord; IEC320-C8 to United Kingdom S-BN-24/1500-UK1
AC power cord; IEC320-C8 to Australian S-BN-24/1500-AU1
Note!
All units ship with US/Japan AC power cord. For other regions, power cords must be ordered
seperately
PG12-BTC1
Input 80 ... 264 VAC
Output 12 VDC
Power 60 Watts

2018-10
10
Industrial Box Thin Client
Product Description
Efficiency 88 %
Operating Temperature -30 ... 60 °C
Storage Temperature -40 ... 85 °C
Humidity 20% ... 95% RH Non-condensing
Dimensions 125 x 50 x 31.5 mm
PG12-BTC1

Industrial Box Thin Client
Installation
2018-10
11
3Installation
3.1 Mounting
Attaching Brackets to the Steel Base
There are two brackets that you attach to the steel base so that you can mount the unit on the
wall. The unit must be mounted so that the heat fins are vertical to allow for proper convection
cooling.
Attaching Brackets
1. Remove the feet from the steel base.
Figure 3.1
Warning!
Install the device in accordance with the instructions by competent personnel. Observe
national laws and regulations.
Warning!
Hot surface
The surface of the unit can be hot when system is in use.
1
1

2018-10
12
Industrial Box Thin Client
Installation
Figure 3.2
2. Use the screws from the feet to attach the brackets to the steel base as shown
below.
3. Use appropriate mounting screws with a diameter of 5 mm (not included) and the following
mounting diagram to mount the unit to a wall.
1
2
1
2

Industrial Box Thin Client
Installation
2018-10
13
Figure 3.3 - for mounting screws Ø 5 mm
3.2 Electrical Connection
There are three different connection options depending on the ordered device type.
Figure 3.4 - Electrical connection depending on device type
AC
For AC power, you insert a plug into the back of the unit. AC power utilizes connector type C14.
See Figure below.
265
170
1
1
1
Warning!
Do not connect or disconnect the electrical connection of the device in the presence of a
potentially explosive atmosphere.

2018-10
14
Industrial Box Thin Client
Installation
Any cable used has to fullfil the following specifications:
■The cable needs to be rated for at least 60°C.
■The cable has to be double insulated.
■The cable has to have an individual wire size of at least 18 AWG (0.75 mm²).
■The cable has to have a ground conductor with the same size as the other 2 conductors.
■The cable must be rated for 10 A for the AC version.
■The cable has to be connected to a type TN power system, protected by a maximum 20 A
breaker or fuse.
■The socket outlet should be close to the equipment and easily accessible.
Figure 3.5 C14 receptacle
1 & 3 = AC power
2 = ground
DC 12 V
For 12 VDC power, you insert a power jack into the back of the unit. The connector on the back
of the unit is a 5.5 mm barrel jack. The polarity of the plug is center positive. For this option, an
AC power adapter with 5.5 mm barrel jack is supplied.
Figure 3.6 12 VDC barrel jack
Warning!
The connector on the back of the unit is an IEC320-C14 receptacle and requires a mating of an
IEC320-C13.
The intended installation location is an overvoltage category II. The Industrial Box Thin Client
BTC01 comes with an AC power cable that is intended for US type outlet. Other power cables
for other global regions are available as accessories. See chapter 2.5.
1
2
3
Warning!
The 12 V DC power has to be provided from a rated supply of -20°C to 60°C, and has to
provide a SELV output according to IEC60950-1. This supply has to be powered from an OVC II
source.
12 VDC

Industrial Box Thin Client
Installation
2018-10
15
DC 18 ... 30 V
For 18 VDC ... 30 VDC power (including 24 VDC), a terminal block DFK-MC 1,5/ 3-GF-3,81 BK
(Phoenix Contact) is attached to the back of the unit. A matching connector MC 1,5/ 3-STF-
3,81 BK (Phoenix Contact) to attach the customers wiring is included. The range of wire size for
this setup is 14 AWG ... 18 AWG.The recommended tightening torque is 0.24 Nm (2 in-lbs).
The pinout for the power connection is as follows.
■Position 1: +VDC
■Position 2: -VDC
■Position 3: Ground
Figure 3.7 18 VDC ... 30 VDC terminal I/O plate
3.3 I/O Connection
Figure 3.8 BTC01 Industrial Box Thin Client I/O Connection Ports, Front
Warning!
The 18 VDC ... 30 VDC power has to provide a SELV output according to IEC60950-1. This
supply has to be powered from an OVC II source.
18-30 VDC
Front
1Power Switch
2USB 2.0 Ports
1 2

2018-10
16
Industrial Box Thin Client
Installation
Figure 3.9 BTC01 Industrial Box Thin Client I/O Connection Ports, Back
Back
1PS/2 Mouse Port
2COM Port 1 (COM1)
3COM Port 3 (COM3)
4LAN RJ-45 Port
5HDMI Port (HDMI2)
6LAN RJ-45 Port
7DVI-D Port
8Line out (green)
9Microphone (pink)
10 USB 3.0 Ports (USB3_0_1)
11 USB 2.0 Ports (USB_0_1)
12 VGA Port (VGA1)
13 COM Port 2 (COM2)
14 PS/2 Keyboard Port
15 HDMI Port (HDMI1)
1 42 3 5 6 7
15 14 13 12 11 10 9 8

Industrial Box Thin Client
Installation
2018-10
17
PS/2 Port
Figure 3.10
RS-232 Port
Figure 3.11
Pin PS/2
1Keyboard data
2Not used
3Ground
4+5 Volt
5Clock
6Not used
Pin RS-232
1DCD
2RXD
3TXD
4DTR
5GND
6DSR
7RTS
8CTS
9COM1: +5V/+12V/+5VSB
COM2, 3: +5V/+12V
12
34
56
1
9
5
6
Note!
Use the cable retention bracket (3) to mount the connectors to the COM ports securely. See
chapter 3.3.1.

2018-10
18
Industrial Box Thin Client
Installation
RJ45 Port
Figure 3.12 There are two LEDs next to the LAN port. The green LED is the Act/Link LED. The
yellow LED is the Speed LED. Please refer to the table "LED display" below for the
LAN port LED indications.
LED display
HDMI Port
Figure 3.13
Pin RJ45
1Tranceive d ata+
2Tranceive d ata-
3Receive data+
4Bidirectional data+
5Bidirectional data-
6Receive data-
7Bidirectional data+
8Bidirectional data
Status LED green LED Yellow
Off No Link 10 Mb/s connection
Blinking Data Activity 100 Mb/s connection
On Link 1 Gb/s connection
Pin RJ45
1TMDS data 2 +
2TMDS data 2 shield
3TMDS data 2 -
4TMDS data 1 +
5TMDS data 1 shield
6TMDS data 1 -
7TMDS data 0 +
8TMDS data 0 shield
18
1 2
1
2
1
218
19

Industrial Box Thin Client
Installation
2018-10
19
DVI-D Port
Figure 3.14
9TMDS data 0 -
10 TMDS clock +
11 TMDS clock shield
12 TMDS clock -
13 CEC
14 Reserved
15 SCL
16 SDA
17 DDC/CEC ground
18 +5 V power
19 Hot plug detect
Pin DVI-D
1TMDS data 2 -
2TMDS data 2 +
3TMDS data 2/4 shield
4TMDS data 4 -
5TMDS data 4 +
6DDC clock (SCL)
7DDC data (SDA)
8Not used
9TMDS data 1 -
10 TMDS data 1 +
11 TMDS data 1/3 shield
12 TMDS data 3 -
13 TMDS data 3 +
14 +5 VDC
15 Ground
16 Hot plug detect
17 TMDS data 0 -
18 TMDS data 0 +
19 TMDS data 0/5 shield
20 TMDS data 5 -
21 TMDS data 5 +
22 TMDS clock shield
23 TMDS clock +
24 TMDS clock -
Pin RJ45
1
9
17

2018-10
20
Industrial Box Thin Client
Installation
USB Port
Figure 3.15
VGA Port
Figure 3.16
3.3.1 Use of PS/2 Ports in Hazardous Locations
Mounting the Cable Retention Bracket
Pin USB
1+5 Volt
2Data -
3Data +
4Ground
Pin VGA
1Red video
2Green video
3Blue video
4Reserved
5Ground
6Red ground
7Green ground
8Blue ground
9Not connected
10 Ground
11 ID0 (ground)
12 ID1 (no connect)
13 Horizontal sync
14 Vertical sync
15 Not connected
1234
15
15
6
10
11
Warning!
All connectors with screw terminals must be appropriately fastened.
Table of contents