Phantom PHOTOBIO TX User manual

USER MANUAL
TM
PHOTOBIO•TX
TM
INSTRUCTIONS EN FRANÇAIS. . . . . . . . . . . . . . . 14-25
INSTRUCCIONES EN ESPAÑOL. . . . . . . . . . . . . . . 26-38

www.phantombio.com
2
USER MANUAL
OVERVIEW
PHOTOBIO•TX Top light
• 1768 μmol/s Photon Flux @277V
• 2.6 μmol/J Ecacy@277V
• Ideal for sole source indoor and
supplemental greenhouse applicaons
• Thin linear top light design minimizes
sun interference in greenhouses while
providing beer canopy access when
applied indoors
• Highly eecve heat pipe cooling system
provides superior heat dissipaon
• Precisely control photon output when
paired with Autopilot PX series controller
(PX2 and above)
• Driver can be mounted remote
• IP65 wet locaon rated protecon against
water and dust
• 100-277V Driver range
• 5 Year Warranty
SPECTRA
380
0.0
0.2
0.4
0.6
0.8
1.0
480580680780
Wavelength(nm)
Normalized Photon Output
S4 SPECTRUM
5" / 130.0 mm
7½" / 187.5 mm
7" / 175.5 mm
42¼" / 1070.0 mm
PRODUCT DIMENSION
Item Code Model Spectrum Application Photon Flux
(µmol/s) Power (W) Efficacy
(µmol/J) Dimming IP Weight Voltage Lifetime
to L90
PTB5680LS4X PHOTOBIO·TX S4 Vegetative &
Flowering 1768 680 2.6 0-10V IP65 28.90 lbs/13.10 kg100-277V ≥50,000 hr
ELECTRICAL SPECIFICATION

3
TM
USER MANUAL
Allows linking of xtures together to control light output and photoperiod when used with
controller. Jumper is used between aisles or levels if needed.
Item Code Description
PTBCCJ16W PHOTO LOC 0-10V Control Cable 16' Jumper (White)
PARTS LIST A. PHOTOBIO·TX xture
B. PHOTOBIO 680W Driver (x1)
C. PHOTO LOC 0-10V Control
Cable 8' Trunk + 5' Branch (x1)
D. Driver fastener (x2)
E. Fixture hanger A (x2)
F. Fixture hanger B* (x2)
G. Driver hanger (x2)
H. User manual (not shown)
Sold separately
CABLE HARNESSES
Power cable harness sold separately based upon your specic requirements
A
B
CD
F
E
G
Type of Male Item Code Description
CHE1063000W 10' F 16AWG WT w/leads, Harness
CHE1063010W 10' F 16AWG WT 110-120V Plug, 5-15P, Harness
CHE1063015W 10' F 16AWG WT 208-240V Plug, 6-15P, Harness
CHE1083020W 10' F 18AWG WT locking 277V, L7-15P, Harness
CHE1083021W 10' F 18AWG WT locking 277V, L7-20P, Harness
Item Code Description
APDPX2 Autopilot PX2 Advanced Lighting Controller
AUTOPILOT PX2 ADVANCED LIGHTING CONTROLLER
Centralized control of up to 80 PHOTOBIO xtures. Provides dual zone photoperiod ming,
photosynthec photon ux scheduling, temperature based auto-dimming, high temp
shutdown, sunrise/sunset simulaon, with built in baery backup.
• Avoid direct eye exposure to the light source while it is on.
• Account for small parts and recycle or dispose of packing
material properly.
*Allows truss to run through
xture body when driver is
remotely mounted

www.phantombio.com
4
USER MANUAL
WARNINGS
• For the installaon: if you are unsure about the installaon or maintenance of this
xture, consult a qualied licensed electrician and check your local electrical code.
• Do not make or alter any open holes in an enclosure of wiring or electrical components
during kit installaon.
• Turn o the power and unplug xture when you perform any maintenance or cleaning
acvity.
• Verify that supply voltage is correct by comparing it with the informaon on spec label.
• Avoid hing, bending or causing mechanical stress to the xture.
• DO NOT cover or block any part of the xture during operaon.
• To ensure opmal performance, the back of the lighng panels may require periodic
cleaning. Clean with compressed air or damp lint free cloth.
• 12" Clearance must be maintained from any combusble surface.
• Always provide a well-venlated environment where ambient temperatures do not
exceed 40°C (104°F) regardless of whether the xtures are in operaon or o. Excessive
temperatures can inhibit performance and may cause damage or shorten the life of the
xtures and void the warranty.
• Do not run or store xtures in the facility unless proper environmental cooling systems
are in operaon. Facilies that are “shut down” can record excessively high temperatures
resulng in premature equipment failure.
• When calculang cooling needs for your facility, take into consideraon BTU load
generated by LED xtures and latent load generated by plant transpiraon, human
respiraon, etc...
• This IP 65 LED xture is intended for indoor use only. Avoid high pressure jets of water.
• Do not expose the xture to the sulfur dioxide compound. If sulfur applicaon is part of
your pracce, please make sure to remove the xtures prior to this process.
WARNING – POSSIBLE RISK OF INJURY TO EYES AND SKIN
Hazardous optical UV, HEV, and IR radiation may be emitted from the
light source. Always wear personal protective equipment ensuring
complete shielding of skin and eyes. Avoid prolonged exposure and
looking directly at light source.

5
TM
USER MANUAL
INSTALLATION
Ceiling
Wall
Wall
≥ 6inch
≥ 2inch
≥ 2inch
• Cables shall not be concealed or extended through a wall, oor, ceiling, or other parts of
the building structure.
• Cables shall not be located above a suspended ceiling or dropped ceiling; permanently
axed to the building structure.
• Cables shall be routed so that they are not subject to strain and are protected from
physical damage; and visible over their enre length.
• Cables shall be used within their rated ampacity as determined for the maximum
temperature of the installed environment specied in the instrucons.
• This device complies with part 15 of the FCC Rules. Operaon is subject to the following
two condions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operaon.
• CAN ICES-3(B)/NMB-3(B)
Fig. 1

www.phantombio.com
6
USER MANUAL
PHOTOBIO•TX driver is designed to be mounted either aached to the xture or mounted
remotely. To aach the driver on the xture, follow the steps below:
Take out lighng xture (Part A) and driver (Part B) out of box with care. Screw ght the driver
fasteners (part D). This step is important to secure the driver in place, see Fig. 2.
Plug in the DC cables of lighng xture to driver's DC connector, see Fig. 3. Spin the orange cap
ll ght. This step can be omied for the rst me, as the DC connectors and DC cables are
connected by default out of box.
Fig. 2
Fig. 3

7
TM
USER MANUAL
a. Suspended mounng
1) With xture hanger A (Part E) , as Fig. 4.
Fig. 4

www.phantombio.com
8
USER MANUAL
2) With xture hanger B (Part F), as Fig. 5.
b. Strut mounng
1) With xture hanger A (part E), as Fig. 6. Fixture hanger B (Part F) is not compliant for this
44mm
28mm
Fig. 5
Fig. 6

9
TM
USER MANUAL
Connect the power cable harness with the driver AC connector, as shown in Fig. 7.
Dimming connection
AC input power connector Power cable harness
Fig. 7
The product is equipped with dimming connecon supporng 0-10V dimming signal. Use the
provided PHOTO LOC 0-10V Control Cable (Part C) to interface with Autopilot PX2 advanced
digital & analog lighng controller (APDPX2) to centralize control of up to 80 PHOTOBIO xtures.
For connecons between aisle to aisle, please use PHOTOBIO LOC 0-10V Control Cable 16'
Jumper (PTBCCJ16W).

www.phantombio.com
10
USER MANUAL
Advanced Digital & Analog
Lighting Controller(APDPX2)
Fixtures are not shown to scale.
PHOTO•LOC Cable
PTBCC8850W
Female end
Male end
LEGEND:LED Fixtures
ZONE A
Controls up to
40 LED fixtures.
ZONE B
Controls up to
40 LED fixtures.
PHOTO LOC 0-10V Control Cable
8' Trunk + 5' Branch
PTBCC8850W
PHOTOBIO•TX
LED Fixtures
1
2
Attach WHITE end on the
longer trunk of the cable to
the ORANGE end on the
shorter trunk of the
previous cable.
Attach ORANGE end on
the branch of the cable to
the white connector on
fixture.

11
TM
USER MANUAL
Note: Zone A and Zone B
can be set up in one room,
or in two separate rooms.
IMPORTANT: Do not attach data link cables to AC power cable. Always keep low voltage data cables and high
voltage AC power harness as far as possible from each other for stable signal transmission. Avoid coiling data as
well as AC harnesses in circles. Excess cable should be managed by creating long loops as opposed to tight coils.
IMPORTANT: Do not attach data link cables to AC power cable. Always keep low voltage data cables and high voltage AC
power harness as far as possible from each other for stable signal transmission. Avoid coiling data cables as well as AC
harnesses in tight coils. Excess cable should be managed by creating long loops as opposed to tight coils.

www.phantombio.com
12
USER MANUAL
Loosen the 2 orange driver fasteners (Part D), slide the driver to end in the direcon to AC
side, as Fig. 8, and take out driver from xture.
Note: PHOTOBIO suggests to screw back the 2 orange driver fasteners (Part D) onto xture
to avoid missing, for future use. as Fig. 9.
Hook the driver box with the provided driver mounng hanger (Part G), and mount the
driver onto the rack, as Fig. 10 and Fig. 11.
44mm
28mm
Fig. 8
Fig. 9
Fig. 10

13
TM
USER MANUAL
Mechanical hazard: Avoid shaking or dropping the driver!
Fig. 11
Mount with xture hanger A (Part E) as Fig. 12, or mount with xture hanger B (Part F) as Fig.
13. Fixture hanger B (Part F) allows truss to run through xture body in this mounng way.
As Fig. 12, plug in the DC cables of lighng xture to driver's DC connectors. Spin the orange
cap ll ght. Make sure each cable plugs into its adjacent connector.
AC input power connectionDC connection
44mm
28mm
Fig. 12
Fig. 13

www.phantombio.com
14
MANUEL D’UTILISATION
SPECTRA
380
0.0
0.
2
0.4
0.6
0.8
1.0
480580680780
Longueur d’onde (nm)
Sortie de photons normalisée
S4 SPECTRUM
Code item Modèle Spectre Application Photon Flux
(µmol/s)
Puissance
(W)
D’efficacité
(µmol/J) Variation IP Poids Voltage Durée de vie
L90
PTB5680LS4X PHOTOBIO·TX S4 Végétaux et
fleurs 1768 680 2.6 0-10V IP65 28.90 lbs/13.10 kg 100-277V ≥50,000 hr
CARACTÉRISTIQUES ÉLECTRIQUES
APERÇU
• 1768 µmol/s Photon Flux @277V
• 2.6 μmol/J D’ecacité @277V
• Idéal comme source unique de lumière pour
les applicaons intérieures et source de
lumière supplémentaire pour les serres
• La concepon ne et linéaire de l'éclairage
minimise l'interférence avec l’ensoleillement
dans les serres tout en fournissant un
meilleur accès à la couverture végétale
lorsqu'il est appliqué à l'intérieur.
• Un système de refroidissement par caloducs
très ecace assure une meilleure dissipaon
de la chaleur
• Contrôle précis de la sore des photons
quand couplé avec le contrôleur de la série
Autopilot PX (PX2 et supérieur)
• Le driver peut être monté à distance
• Protecon IP65 contre l'eau et la poussière
dans les endroits humides
• Gamme du driver 100-277V
• 5 ans de Garane
5" / 130.0 mm
7½" / 187.5 mm
7" / 175.5 mm
42¼" / 1070.0 mm
DIMENSIONS DU PRODUIT

15
TM
MANUEL D’UTILISATION
FAISCEAUX DE CÂBLES
Le faisceau de câbles d'alimentaon est vendu séparément en foncon de vos besoins spéciques.
LISTES DES PIÈCES A. Luminaire PHOTOBIO·TX
B. Driver PHOTOBIO 680W (x1)
C. Contrôle PHOTO LOC 0-10V
Câble 8' (2,40 m) Principal + 5' (1,50 m)
Dérivaon (x1)
D. Aache du driver (x2)
E. Suspension du luminaire A (x2)
F. Suspension du luminaire B* (x2)
G. Aache du driver (x2)
H. Manuel d’ulisateur (non présenté)
A
B
CD
F
E
G
• Éviter de regarder directement la source de lumière lorsqu'elle est
allumée.
• Vérier les petes pièces et recycler ou éliminer correctement le
matériel d'emballage.
*Permet de faire passer la poutrelle
à travers la structure de l'appareil
lorsque le driver est monté à
distance
Permet de relier des luminaires entre eux pour contrôler le rendement lumineux et la photopériode
avec un contrôleur. Le Jumper est ulisé entre les rangées ou les niveaux si nécessaire.
Code item Description
PTBCCJ16W PHOTO LOC 0-10V Câble de contrôle 16' (4,85 m) Jumper (Blanc)
Type de mâle Code item Description
CHE1063000W Faisceau 10' F 16AWG WT w/leads
CHE1063010W Faisceau 10' F 16AWG WT 110-120V Plug, 5-15P
CHE1063015W Faisceau 10' F 16AWG WT 208-240V Plug, 6-15P
CHE1083020W Faisceau 10' F 18AWG WT locking 277V, L7-15P
CHE1083021W Faisceau 10' F 18AWG WT locking 277V, L7-20P
Code item Description
APDPX2 Autopilot PX2 contrôleur avancé d’éclairage
AUTOPILOT PX2 CONTRÔLEUR AVANCÉ D’ÉCLAIRAGE
Contrôle centralisé jusqu'à 80 luminaires PHOTOBIO. Fournit une synchronisaon de la photopériode
à deux zones, une programmaon du ux de photons photosynthéques, un réglage automaque de
la température, un arrêt haute température, une simulaon du lever et du coucher du soleil, avec une
baerie de secours intégrée.

www.phantombio.com
16
MANUEL D’UTILISATION
PRÉCAUTIONS
• Pour l’installaon. Si vous n'êtes pas sûr de l'installaon ou de l'entreen de ce luminaire,
veuillez consulter un électricien qualié et agréé ainsi que les normes électriques de votre
région.
• Ne pas faire ou modier des trous ouverts dans une gaine de câblage ou de composants
électriques pendant l'installaon du kit.
• Couper le courant et débrancher le luminaire avant de réaliser tout entreen ou neoyage.
• Vérier que la tension d'alimentaon est correcte en vériant les informaons gurant sur
l'équee du luminaire.
• Éviter de frapper, de plier ou d’exercer des contraintes mécaniques sur l'appareil.
• NE couvrir ou bloquer AUCUNE pare de l’appareil pendant l’opéraon.
• Pour assurer un fonconnement opmal, l'arrière des panneaux d'éclairage doit être
régulièrement neoyé. Neoyer à l'air comprimé ou avec un chion humide sans
peluches.
• Une distance de 12" (30 cm) doit être maintenue par rapport à toute surface combusble.
• Prévoir toujours un environnement bien aéré où la température ambiante ne dépasse
pas 40°C (104°F), que les luminaires soient en fonconnement ou non. Des températures
excessives peuvent compromere le fonconnement des luminaires et peuvent les
endommager ou réduire leur durée de vie, ce qui annulerait la garane.
• Ne pas faire fonconner ou stocker des luminaires dans l’installaon, à moins qu'un
système de refroidissement environnemental approprié soit en service. Des installaons
« fermées » peuvent enregistrer des températures excessivement élevées, entraînant une
défaillance prématurée de l'équipement.
• Pour calculer les besoins de refroidissement de votre installaon, prenez en considéraon
la puissance BTU générée par les luminaires à LED et la puissance latente générée par la
transpiraon des plantes, la respiraon humaine, etc.
• Ce luminaire LED IP 65 est desné à un usage intérieur uniquement. Éviter les jets d'eau à
haute pression.
• Ne pas exposer le luminaire au composé de dioxyde de soufre. Si vous appliquez du soufre,
assurez-vous d'enlever les appareils avant de procéder à cee opéraon.
ATTENTION – RISQUE DE BLESSURE POUR LES YEUX ET LA PEAU
La source de lumière peut émettre des rayonnements optiques dangereux
(UV, HEV et IR). Toujours porter un équipement de protection individuelle
assurant une protection complète de la peau et des yeux. Éviter les
expositions prolongées ainsi que de regarder directement la source de
lumière.

17
TM
MANUEL D’UTILISATION
• Les câbles ne doivent pas être enfouis ou prolongés à travers un mur, un plancher, un
plafond ou d'autres pares de la structure du bâment.
• Les câbles ne doivent pas être situés au-dessus d'un plafond suspendu ou d'un faux
plafond ; ils doivent être xés de façon permanente à la structure du bâment.
• Les câbles doivent être acheminés de manière à ne pas être soumis à des tensions et à
être protégés contre les dommages physiques ; et être visibles sur toute leur longueur.
• Les câbles doivent être ulisés dans les limites de leur intensité nominale déterminée pour
la température maximale de l'environnement installé, spéciée dans les instrucons.
• Cet appareil est conforme à la secon 15 de la réglementaon FCC. Le fonconnement est
soumis aux deux condions suivantes: (1) Ce disposif ne doit pas causer d'interférences
nuisibles, et (2) ce disposif doit accepter toute interférence reçue, y compris les
interférences qui peuvent causer un fonconnement non désiré.
• CAN ICES-3(B)/NMB-3(B)
INSTALLATION
Plafond
Mur
Mur
≥ 6 pouces (15 cm)
≥ 2 pouces (5 cm)
≥ 2 pouces (5 cm)
Fig. 1

www.phantombio.com
18
MANUEL D’UTILISATION
Le driver PHOTOBIO•TX est conçu pour être monté soit sur l'appareil, soit à distance. Pour
xer le driver sur l'appareil, suivez les indicaons ci-dessous:
Rerer avec précauon le luminaire (pièce A) et le driver (pièce B) de la boîte. Visser les aaches
du driver (pièce D). Cee étape est importante pour xer le driver à sa place, voir gure 2.
Branchez les câbles DC du luminaire sur le connecteur du driver, voir la gure 3. Vissez le
bouchon orange jusqu'à ce qu'il soit bien serré. Cee étape peut être omise la première fois, car
les connecteurs DC et les câbles DC sont connectés par défaut hors de la boîte.
Fig. 2
Fig. 3

19
TM
MANUEL D’UTILISATION
a. Montage suspendu
1) Avec le support de xaon A (pièce E), voir g. 4.
Fig. 4

www.phantombio.com
20
MANUEL D’UTILISATION
2) Avec le support de xaon B (pièce F), voir g. 5.
b. Montage du renfort
1) Avec le support de xaon A (pièce E), voir g. 6. Le support de xaon B (pièce F) n'est pas
conforme à cee méthode de montage.
44mm
28mm
Fig. 6
Fig. 5
This manual suits for next models
2
Table of contents
Languages:
Popular Home Lighting manuals by other brands

Rexel
Rexel ActiVita Daylight Pod+ instruction manual

Lodes
Lodes Diesel Living Magic Mushroom manual

Dale Tiffany
Dale Tiffany PT12301 Assembly instructions

Philips
Philips Ledino 16800/93/16 Specifications

LA VAGUE
LA VAGUE GOOGLY instruction manual

OTT-LITE TECHNOLOGY
OTT-LITE TECHNOLOGY Amelia 25392ABK manual

Hunter
Hunter Bullet Spotlight Kit Owner's guide and installation manual

XTRASUN
XTRASUN XTDEOKT1 user manual

Ingo Maurer
Ingo Maurer Kuddelmuddel instructions

Triarch
Triarch Indoor Lighting 25413 Assembly instructions

Satechi
Satechi Flexible LED ST-DL50H user manual

marset
marset LED PIPE lectura Assembly instructions