NOTICE
- To prevent defect or failure, please check the cable connections and power-supply condition before
power-on.
- The Module is controlled by high voltage. Not only during operation but also immediately after power-off, do
not disconnect or reconnect the Module's connector because it may result in failure. If you need to
disconnect or reconnect, you have to wait at least one minute after power-off.
- The Module is equipped with various protection circuits that automatically stop the Module operation, if an
interface signal or the power voltage becomes abnormal during operation. If the Module stops suddenly
during operation, please check the conditions of input signal or power source before restarting.
- For the protection of the circuit, if an abnormal situation is occurred, the high output voltage will be shut
down by (watching) the internal input voltage (Vs/ Va/ Vcc). In this case, the Module power resetting is
necessary to recover. There are also fuses in the Vs and Va power supply system to prevent smoking and
firing by the excessive current. The protecting function of the address driver of keeping a supervisory
device for the internal current is provided in the Va power supply system. Therefore, the number of
sub-frames decreases to a proper value when the Ia current exceeds a constant value occasionally.
- If an abnormal situation such as disconnecting of the input connector occurs, this Module will be on stand-by,
which the supply of high output voltage is stopped even if an external power is being supplied. If a normal
signal is inputted after this, normal operation state, operations can be restarted again by re-inputting a
normal signal. However, it is necessary to rest the Module power when tVH and/or tHV are less than the
minimum value provided in the specification
- To ensure reliable operation of the Module and to protect it from overheating, do not wrap or cover it with a
cloth or like a sheet during power-on period. Also, do not place the Module in a confined space or any other
places of poor ventilation.
- If you continue to watch the naked screen (without filter glass) for a long time, your eyes could be fatigued.
We recommend you rest your eyes occasionally. However, according to the information currently available,
watching PDP module for a long time does not cause a direct harm to your eyes.
- The screen is controlled with the display-data signals and synchronized signals. If noise interferes with those
signals, the screen could become unstable and, in some case, would cause a failure. Do not place any
equipment that generates excessive EMI/RFI noise near the interface cable of the Module, and keep the
cables as short as possible.
- Be careful not to break the glass panel when you handle the Module. Also, when handling the Module, you
must wear gloves or other hand protection to prevent injuries that can occur in case when the glass panel is
broken.
- The glass panel section and drive circuit section of the Module are closely connected and they function as a
pair. If the Module is arbitrarily recombined, restructured, or disassembled, SDI will not be responsible for
the function, quality, or operational integrity of the modified Module. Do not recombine, restructure, or
disassemble it. (Only, the Module for A/S is allowed to be recombined, restructured, or disassembled.)
- To avoid a possible electric shock, you must make sure that the power supply voltage of Module is turned
off before cleaning. To clean the module’s glass panel, apply water or a natural detergent to a piece of
soft cloth or gauze, and wring the cloth tightly before wiping the screen. Make sure that no water comes in
contact with the connecting terminals on the side of the glass panel. Do not use chemical solvents, such
as paint thinner or benzene, to clean the glass panel.